Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

WR22 10 - 400 P 131110 e 00

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

2/2 Solenoid Cartridge Valve, 10 mm

Two Stage Seat Valve Design, Flow is checked B ⇒ A


Series WR22G ... / WR22O ...

S 350 bar, 140 l/min livers an outstanding Price/Perfor−


S High flow rates mance ratio and good ∆p−Q character-
S No flow loss through the pilot stage istics. All exposed steel parts are zinc
All exposed steel parts are zinc plated to ISO 4042 and the valves are
plated to ISO 4042 therefore s uitable for use in the
S Wet−armature solenoid with high− harshest operating environments. The
pressure core tube and slip−on coil core tube / slip−on coil design allows
S Coil can be changed without open- coils to be changed opening the hy-
ing the hydraulic envelope draulic envelope, even when the valve
S For BUCHER cavity types DD / DC is under pressure. Coils can be se-
S Line mounting body (G 1/2") is avail- cured at any angle through 360° and
able are available with most common electri-
S Can be fitted in various stack−mount- cal connectors. For customers who
ing bodies manufacture their own manifold blocks,
we offer form tools for sale or hire. For
1. Description
pipe−mounted applications, the
Series WR22...10 directional valves are BUCHER DC−12 and DD−12 line
solenoid operated, two stage seat− mounting bodies (both with G 1/2"
type screw−in cartridges, nominal size threads) are available.
10 mm. The straightforward design de-
2. Symbols
WR22GE..A−10 B WR22OE..A−10 B
For checked flow A −> B WR22GN..A−10 WR22ON..A−10
see data sheet ....131120..
A A

3. Characteristics

Type 2/2 solenoid cartridge valve


Design two stage, seat type with checked flow B ⇒ A
Mounting method screw−in cartridge
Size nom. 10 mm, BUCHER cavity type DD,
with adapter ring C: BUCHER cavity type DC
Mass kg 0,50
Mounting attitude unrestricted
Flow direction A ⇒ B / B ⇒ A, see symbols
Operating pressure bar to 350 in A and B
Flow rate Qmax l/min 140
Fluids Hydraulic oils HL and HLP to DIN 51 524,
other fluids − contact BUCHER
Fluid temperature range _C −25 ... + 80
Ambient temperature _C −25 ... + 50
Viscosity range cSt 10 ... 500, recommended 15 ... 250
Minimum fluid cleanless 18/14 to ISO 4406 /CETOP RP70H 8 ... 9 to NAS 1638
Standard voltages VAC 115, 230 50 ... 60 Hz
VDC 12, 24
Nom. voltage tolerance % $10
Nom. power consumption VAC 17W (Option: 25 W)
VDC 17W (Option: 27 W)
Duty cycle % ED 100
Enclosure protection IP 65 to DIN 40050
Electrical connection 3−pin square plug to DIN 43 650 / ISO 4400 (standard),
other connectors − contact BUCHER

Replaces: W−6.155 1/4 Classification: 430.30.15.12


Reference: 400−P−131110−E−00/07.02
4. Performance graphs
Oil viscosity 33 cSt
coil steady−state temperature
10% under−voltage
∆p−Q characteristic ∆p−Q characteristic
A⇒B WR22GE..A−10
WR22GN..A−10
20 deenergised 20
18 18
16 B⇒A 16
B⇒A
14 14
energised energised
12
12 A⇒B
10 10
deenergised A⇒B

→ ∆p (bar)
→ ∆p (bar)

8 8
6 A⇒B 6 energised
4 energised 4
2 2

10 20 30 40 50 60 70 80 90 100 120 140 10 20 30 40 50 60 70 80 90 100 120 140


→ Q (l/min) → Q (l/min)

∆p−Q characteristic
WR22ON..A−10 / WR22OE..A−10
20
18
16
14
12 A⇒B/B⇒A
10 deenergised
A⇒B
→ ∆p (bar)

8
6 energised
4 Performance limits
2 None within the
range
10 20 30 40 50 60 70 80 90 100 120 140
→ Q (l/min) p = 350 (bar)
Q = 140 (l/min)

WR22GN..A−10 WR22GE..A−10 WR22ON..A−10 WR22OE..A−10


SWITCHING TIMES
Flow direction Solenoid ON 30 ... 70 ms 30 ... 70 ms 50 ... 200 ms 50 ... 250 ms
A ⇒ B and B ⇒ A Solenoid OFF 100 ... 150 ms 100 ... 250 ms 30 ... 70 ms 30 ... 70 ms
These times are strongly influenced by fluid pressure, flow rate and oil viscosity

400−P−131110−E−00/07.02 2/4
5. Dimensions
ø 30
2,5

Manual override on type WR22O..10 only


Clearance to remove plug
12
10

PG 9

ø 36
58
53
81

Model
128,5

code
131

WR22 ... 27 A/F hex. for fitting the cartridge


18

tightening torque
Ma = 23 ... 27 Nm
With adapter ring C:
25,5

BUCHER cavity type DC


M 24 x 1,5 For use, for example, in line mounting body type DC−12.
47,5

Without adapter ring C:


B
13

BUCHER cavity type DD


For use, for example, in line mounting body type DD−12.

A
ø 15,8
ø 22,2

6. Schematic section
4 WR22GE..A−10 Seal kit no. DS−276, comprising:
WR22GN..A−10 Itm. Qty. Description Size
1 1 Seal ∅ 22,1 / 16,5 x 2,5
2 1 O−ring no 117 ∅ 20,29 x 2,62 N90
3 1 O−ring no 020 ∅ 21,95 x 1,78 N90
4 2 O−ring ∅ 16,00 x 2,00 Viton
5 1 O−ring ∅ 27,00 x 1,5 N75

B
4

3 5
2
B

1
A WR22OE..A−10
WR22ON..A−10

B
4

A
3
2 5
B

1
A

400−P−131110−E−00/07.02 3/4
7. Installation and servicing
All installation and servicing must be the new seals must be thoroughly oiled the specified tightening torque when fit-
carried out with care, and by qualified or greased before they are fitted. Use ting the cartridge.
personnel only. When changing seals,

8. Model code key

Ex. W R 22G E D A − 10 _ − 1 24 VDC __


W = directional valve
R = check valve function, two−stage seat valve design
checked flow B ⇒ A
22G = 2/2 function, deenergised closed
22O = 2/2 function, deenergised open
N = electrically operated, coil VAC = 25 W / VDC = 27 W
E = electrically operated, coil VAC = 17 W / VDC = 17 W
D = for BUCHER cavity type DD
C = for BUCHER cavity type DC (with adapter ring C)
A ... Q = standard model per relevant data sheet
Z ... R = special features by arrangement
10 = nominal size 10 mm
(blank) = Nitrile seals (standard)
V = Viton seals
Special seals by arrangement
1 ... 9 = design number (omit when or dering new units)
Voltage and current plainly specified
(blank) = with connector plug to DIN 43 650 / ISO 4400 (standar d)
M100 = shipped without DIN connector plug
C = with socket to suit Kostal plug
J = with socket to suit Junior−Timer plug optional connector styles (plug not supplied)
F = with 500 mm flying leads

9. Related data sheets


Old no. New no.
i−32 400−P−040011−E The BUCHER Form Tool Hire Programme
i−45.1 400−P−060111−E BUCHER Cavity Type DC
i−45.2 400−P−060121−E BUCHER Cavity Type DD
W−2.141 400−P−120110−E Optional Electrical Connector Styles
G−24.20 400−P−740101−E Line− and Manifold Mounting Body DC−12 (G 1/2")
G−24.21 400−P−740111−E Line− and Manifold Mounting Body DD−12 (G 1/2")

BUCHER HYDRAULICS www.bucherhydraulics.com


Germany France Netherlands UK USA
Phone +49 7742 85 20 Phone +33 389 64 22 44 Phone +31 79 34 26 24 4 Phone +44 24 76 35 35 61 Phone +1 262 605 82 80
Fax +49 7742 71 16 Fax +33 389 65 28 78 Fax +31 79 34 26 28 8 Fax +44 24 76 35 35 72 Fax +1 262 605 82 78
info.de@bucherhydraulics.com info.fr@bucherhydraulics.com info.nl@bucherhydraulics.com info.uk@bucherhydraulics.com info.wi@bucherhydraulics.com

Switzerland Italy Austria China Product Center (Elevator)


Phone +41 33 67 26 11 1 Phone +39 0522 92 84 11 Phone +43 6216 44 97 Phone +86 10 64 44 32 88 Phone +41 41 757 03 33
Fax +41 33 67 26 10 3 Fax +39 0522 51 32 11 Fax +43 6216 44 97 4 Fax +86 10 64 44 32 35 Fax +41 41 757 16 49
info.ch@bucherhydraulics.com info.it@bucherhydraulics.com info.bj@bucherhydraulics.com info.nh@bucherhydraulics.com

We reserve the right of modification without notice.

400−P−131110−E−00/07.02 4/4