Technical Datasheet

Confil Mortar
General Purpose Polyester Mortar
Description
An extremely versatile two pack general purpose polyester mortar which exhibits a very fast set and rapid strength gain surpassing the
average strength of concrete within 1 hour. Ideal for small general repairs where the rapid set allows the minimum of disruption. Confil
Mortar is designed to comply with the requirements of EN1504 Part 3 Class R3.

Advantages

 Quick curing, high early compressive, flexural and tensile


strength.
0086
 Economic - quantities mixed as needed, therefore very
little wastage. Nufins, Kingston House,
3 Walton Road, Pattinson North, District 15,
 Supplied in polythene buckets, which act as mixing vessels.
Washington, Tyne & Wear. NE38 8QA
 Excellent chemical and water resistance. 13
0086-CPD-594215
 Less than 1% shrinkage.
EN 1504-3
 Simple to use - no critical mixing ratios. Concrete repair product for structural repair
PC Mortar (Polymer mortar)
 Will cure down to 0oC.
Compressive strength Class R3 (>25 MPa)
 No primer required.
Chloride ion content <0.05%
 Available in two grades standard and rapid set. Adhesive bond strength >1.5 MPa

 Complies with EN1504 Part 3 Class R3. Adhesion after freeze/thaw >1.5 MPa

Elastic modulus >15 GPa


Applications Dangerous substances Complies with 5.4

 Repairs to damaged precast units.

 Repairs to spalled concrete roads, runways, etc. Typical Usable Life


 Fixing or bedding of copings and kerbs etc.
Temperature Rapid Grade Standard Grade
 Bedding and raising of manhole frames. Fast-set Slow-set

 Jointing between precast units. 10oC 30 Minutes 50 Minutes


o
15 C 22 Minutes 40 Minutes
 Repairs to stair treads and arrises.
20oC 18 Minutes 30 Minutes

A Company
Head Office: Kingston House, 3 Walton Road, Pattinson North, Washington, Tyne & Wear, UK
T: +44(0) 191 416 8360 F: +44(0) 191 415 5966 W: www.nufins.com E: info@usluk.com Issue: 1/2016
Technical Datasheet
Technical properties of Confil Bedding Mortar.
Properties Standard Performance Requirement Declared Value

Appearance Pale Grey Resinous Mortar


Chloride-ion content EN1015-17 ≤0.05% <0.05%
Aggregate size Max. 1mm
Layer thickness - Minimum 5mm
Maximum 15mm
Working time (@ 23oC) 18-30 minutes
o
Hardening Time (@ 23 C) 20-40 Minutes
Density 2120 kg/m3
Temperature for application 0oC to 35oC*
Compressive Strength EN 12190 80 MPa @ 2 Hours
@ 23oC 85 MPa @ 4 Hours
98 MPa @ 24 Hours
102 MPa @ 3 Days
≥ 25 MPa 105 MPa @ 7 Days
Compressive Strength EN 12190 - MPa @ 2 Hours
@ 7oC 80 MPa @ 4 Hours
95 MPa @ 24 Hours
98 MPa @ 3 Days
100 MPa @ 7 Days
Tensile Strength BS6319-7 ≥ 12.0 MPa
Flexural Strength BS6319-3 ≥ 20 MPa
Modulus of Elasticity, BS6319-3 ≥ 15 GPa
in Flexure
Modulus of Elasticity, EN13412 ≥ 15 GPa 15 GPa
in Compression
Adhesion - concrete EN1542 ≥ 1.5 MPa ≥ 2.0 MPa
Adhesion after freeze/thaw EN13687-1 ≥ 1.5 MPa ≥ 2.0 MPa
(50 cycles with salt)

Adhesion after thunder EN13687-2 ≥ 1.5 MPa ≥ 2.0 MPa


showers (30 cycles)

Adhesion after dry cycling EN13687-4 ≥ 1.5 MPa ≥ 2.0 MPa


(30 cycles)
Skid Resistance EN13036-4 Class 1
Carbonation resistance EN13295 dk ≤ ref. concrete dk < ref. concrete
2 -0.5
Capillary absorption EN13057 ≤ 0.5 kg/m /h ≤ 0.5 kg/m2/h-0.5
Cracking tendency Coutinho ring test No cracking after 180 days
Technical data shown are statistical results and do not correspond to guaranteed minima.
Tolerances are those described in appropriate performance standards.
*- Consult with the technical department when being used at below 5oC.
Once Confil Mortar has fully cured no shrinkage will occur.

A Company
Head Office: Kingston House, 3 Walton Road, Pattinson North, Washington, Tyne & Wear, UK
T: +44(0) 191 416 8360 F: +44(0) 191 415 5966 W: www.nufins.com E: info@usluk.com
Technical Datasheet

Surface Preparation Packaging


All surfaces should be clean, dry free from oil, grease, chemical Confil Mortar is available in 5 kg and 25 kg units, (2.36 litre and
contamination and all loose materials. Oil and grease should be 11.78 litre packs respectively).
removed using Desolve. Concrete surfaces should be free from
laitance, this should be removed by scarifying or etching with
Chemclean. After using Chemclean, and after the reaction has Storage
ceased, wash the surface thoroughly with water and allow to dry.
Confil Resin is flammable (flash point is 31oC), due precautions
On smooth surfaces a stronger bond will result if the substrate is
should be made when handling and storing this material. Shelf
roughened to produce a mechanical key.
life is 6 months when stored correctly in sealed containers,
however at higher temperatures this period will be reduced.
Mixing Store away from food stuffs and out of the reach of children.

Remove the can of Confil Resin and the bags of hardener/aggregate


contained within the plastic mixing bucket. Pour the required Health and Safety
amount of resin into the mixing bucket and add the hardener/
aggregate slowly with continuous mixing until a trowelable Confined areas should be well ventilated. Do not smoke or allow
consistency is achieved. Large quantities should be mixed in a naked flames during use. Confil Mortar, like similar products is
suitable forced action or pan type paddle mixer. capable of irritating unprotected sensitive skin, therefore the use
of gloves and suitable barrier cream is recommended.
Care should be taken not to mix more than can be used within the
setting time of the material.
Limitations

Application Instructions For use below 5oC consult our technical department.

If formwork is used a suitable silicone or wax based release agent


should be used to avoid the sticking of the mortar. The mixed Confil Technical Support
mortar should be trowelled firmly into place to ensure good
adhesion, on dense substrates the mix should be made more resin Through our technical department and laboratories we can offer
rich to ensure good adhesion. A smooth surface can be obtained by a comprehensive service to specifiers and contractors. Our
keeping the face of the float clean by wiping with a cloth dampened technical representatives are available to provide further
with Nuwash. information and arrange demonstrations

It is recommended that the maximum thickness of 15mm per


application should not be exceeded. In addition where multiple
applications are required a rough surface between layers should be
made to provide a mechanical key.

Clean all tools and equipment after use with Nuwash.

A Company
Head Office: Kingston House, 3 Walton Road, Pattinson North, Washington, Tyne & Wear, UK
T: +44(0) 191 416 8360 F: +44(0) 191 415 5966 W: www.nufins.com E: info@usluk.com