Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

OTG Multisensor Fire Detector (CO) IQ8Quad With Isolator: Part-No. 802473

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

OTG multisensor fire detector (CO) IQ8Quad with isolator

Part-No. 802473
Approval: VdS
Multisensor fire detector with integrated smoke detector, heat detector and gas
sensor (CO) with enhanced false alarm management, for preventive and early
detection of deep-seated smouldering fires which give a lot of CO as well as
flaming fires through combined evaluation of scattered light, temperature and gas.
An alarm is actuated at carbon monoxide (CO) concentration levels that are
life-threatening for humans. Less susceptible to false alarms caused by dust, as
well earliest and reliable detection of fire development due to the additional
detection of CO. Also a Technical Alarm (TAL) can be programmed with the
flexible programmable CO threshold up to 150 ppm. The detector is provided with
an integrated isolator. A remote indicator can be connected.

Operating voltage 8 ... 42 V DC


Quiescent current @ 19 V DC 65 µA
Quiescent current @ FACP battery approx. 225 µA @ 27,5 V
Alarm current w/o communication curtain 18 mA
Area to be monitored max. 110 m²
Height to be monitored max. 12 m
Air velocity 0 ... 25.4 m/s

© Honeywell International Inc.


Application temperature -20 °C ... 50 °C
Storage temperature -25 °C ... 75 °C
Type of protection IP 40 (with base + option)
Material ABS plastic
Air humidity < 95 %
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-7/-5 A2 /-17, CEA 4021

Subject to change without notice!


Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)

In the course of installation, we recommend testing the integrated CO sensor with our CO test gas (Part No.
805583) or CO capsule (Part No. 805553).
Durability CO sensor: 5 years
Technical alarm range CO: 10 ppm ? 150 ppm
Gas sensors (CO) mainly react to the carbon monoxide arising from a fire (CO). They have, however, also a
cross sensitivity to other gases, as for example hydrogen (H2), acetylene (C2H2) or nitric oxide (NO).
Special marking for gas detector on the light pipe: golden ring.

Without detctor base

Accessories:
767800 Mounting bracket
805590 Standard detector base for IQ8Quad
805591 Detector base with relay contact for IQ8Quad

Novar GmbH a Honeywell Company Phone: +49 2131 40615 600 www.esser-systems.com
Dieselstr. 2 41469 Neuss Faximile: +49 2131 40615 606 info@esser-systems.com