Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Tank-A Tank-B Tank-C: Bus Bay

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

900

LINE
LINEMATCH
LINEMATCH
LINEMATCH
MATCH
270
LANDSCAPING

PLANTER
LEGEND:

AUTO STAND
6.0m WIDE ROAD
2400 UP
LANDSCAPING

45m 45m 45m INTERNAL


BUS BAY

ROAD
48
OUTER ROAD
33

:200
:2 0 0
:200
Rising Main to ESR

6.0m WIDE ROAD


TANK-A TANK-B

1
TANK-C

E1
1
Overflow Pipe

PE
PE
UP

UP
P

5.50m WIDE ROAD


5.50m WIDE ROAD
Distribution Main

SLOPE 1:200
SLOPE 1:200
SLOPE 1:200

SLO
SLO
SLO
Feeder Main

62m
62m
Scour Pipe

62m
6.0m WIDE ROAD
VENT PIPE (TYP.) VENT PIPE (TYP.) VENT PIPE (TYP.) LANDSCAPING
VALVE
Light Pole

LANDSCAPING GROUND LEVEL RESERVOIR -6 GROUND LEVEL RESERVOIR -5 GROUND LEVEL RESERVOIR -4
1000
A (To be Constructed in Future ) (To be Constructed in Future ) (To be Constructed in Future ) A
· POTABLE WATER GROUND LEVEL STORAGE
0(D) 0(D) 0(D) RESERVOIR (GLSR-P)
SUMP 1200X1200X50 SUMP 1200X1200X50 SUMP 1200X1200X50
BUS BAY

Overflow Overflow Overflow


· POTABLE WATER PUMPING STATION (PWPS) GSLR-P
Scour Scour Scour
UP · LAYOUT OF PUMPING STATIONS & ESR'S
UP UP TOILET

SECURITY NOTES:-
Spare Inlet Spare Outlet Spare Inlet Spare Outlet Spare Inlet Spare Outlet ROOM

1. ALL DIMENSIONS ARE IN MM AND LEVELS ARE IN


5.50m WIDE ROAD
AUTO STAND

M, UNLESS OTHERWISE SPECIFIED.


2. THIS DRAWING SHALL BE MODIFIED BASED ON
Feeder Main
FEEDER PIPE UP UP THE DETAILED DESIGN FROM DBO CONTRACTOR.
Scour Scour 3. LAYOUT DIMENSIONS ARE TENTATIVE. BIDDER
ENTRY GATE
Scour UP
WALL TW1

WALL TW1
HAS TO ASSESS THE PUMP HOUSE DIMENSION

LOADING AND UNLOADEDING BAY


7200
Manhole 1500
COMMON SUCTION HEADER
BASED ON SELECTION OF PUMPS & ELECTRO-
(1.0x1.0m)
F1 F1
(TYP)
F1 F1 F1 MECHANICAL EQUIPMENTS.
SUMP 12045m SUMP 12045m

PUMP HOUSE
0X1200X50

7600
0X1200X50 4. BUTTERFLY VALVE SHALL BE CONFORMING TO IS:

AUTO STAND
0(D) 0(D) C1 C1 C1 C1 C1

(TYP)
1500

FM

FM
FM
45m
PLANTER

Overflow Overflow Overflow


SUMP 1200X1 13095/AWWA C504 AND NON RETURN VALVE
200X500(D)

6900

DRAIN
13000

SHALL BE CONFORMING TO AWWA C508.

WALL TW1
F1 F1 F1 F1 F1
RAMP
RISING MAIN TO ESR-P
5. ALL REDUCERS IN THE SUCTION SIDE ARE
SLO

SLO

SLO
C1 C1 C1 C1 C1
7694 6801 6801 6801 6801 7101
2000 500
ECCENTRIC TYPE WITH FLAT SIDE UP (FSU) AND
TANK-F

SLOPE 1:200

6900
TANK-E

6.0m WIDE ROAD


2500 TANK-D
500
2000 CONCENTRIC TYPE FOR DISCHARGE SIDE.
SLOPE 1:200

SLOPE 1:200
750
PE

PE

PE
750

5.50m WIDE ROAD


5.50m WIDE ROAD
F1 F1 F1 F1 F1
6. THE MATCHING FLANGES OF THE SUCTION &
C1 C1 C1 C1 C1
DELIVERY PIPELINES SHALL BE MATCH WITH THE
1:20

1:20

1:20

PLANTER
PUMPS FLANGES. (AS PER PUMP SUPPLIERS

6900
DRAWINGS)

62m
0

0
F1

62m
F1 F1 F1 F1

0
62m

7. ALL PIPING SHALL BE M.S BLACK ERW HEAVY

SLO
VENT PIPE (TYP.) VENT PIPE (TYP.)

UP
UP

C1 C1 C1 C1 C1

GRADE PIPING AS PER IS: 1239 /IS: 3589


6.0m WIDE ROAD

RAFT 300 THICKNESS

6900
LANDSCAPING 8. THE ULTRASONIC FLOW METER STALL BE

PE
F1 F1 F1 F1 F1

GROUND LEVEL RESERVOIR -3 PROVIDED IN TRANSMISSION MAIN WITH


GROUND LEVEL RESERVOIR -2 C1

1:20
C1 C1 C1 C1

(To be Constructed in Future ) RM-1 DISMANTLING CONNECTION AND SHALL BE KEPT


(To be Constructed in Future ) GROUND LEVEL RESERVOIR -1

6900
(Capacity16 ML ) L=26.255m IN CHAMBER.
D= 1400mmØ 9. Capacity of GLSR Per Unit is 16ML

0
F1 F1 F1 F1 F1

C1 C1 C1 C1 C1 10. This plot also accommodates recycled water ELSR


supplying for Zone 4
B B

6900

25m
F1 F1 F1 F1 F1

WALL TW1
C1 C1 C1 C1 C1

ESR-P1

WALL TW1
A A

7200
2000

750
WALL TW1

B
MAP TITLE:

UP
UP 25m 1100

DISTRIBUTION PIPE
500
GENERAL ARRANGEMENT DRAWING OF

B
16 ML MODULES FOR GLSR IN ZONE 4
6.0m WIDE ROAD

2200
2300

PROJECT INTEGRATED MASTER PLAN & DESIGN


NAME:
FOR HYDERABAD PHARMA CITY
2400

FOR
LANDSCAPING ZONE - 4
PROJECT CODE: C-IN000117

DELIVERABLE BASIC INFRASTRUCTURE


MILESTONE: CATEGORY A: STAGE 4: Version 2

DOCKING STATION

BUS BAY CLIENT:

TELANGANA STATE INDUSTRIAL


0

INFRASTRUCTURE CORPORATION
TELANGANA GOVERNMENT UNDERTAKING
SEAL

DISTRIBUTION PIPE
CONSULTANT:

SURBANA JURONG
CONSULTANTS PTE. LIMITED
SINGAPORE

SEAL
SUB-CONSULTANT
2600 FOR ZONE - 1,2 & 3
BUS BAY
JURONG Consultants (India) Pvt. Ltd. SMEC India Pvt. Ltd.
DOCKING STATION

(A member of Surbana Jurong) (A member of Surbana Jurong)


41/7, 1st & 2nd Floor, 15th Cross, 1st Floor, Novus Tower, West
MES College Road, Malleswaram, Wing, Plot No. 18,
Bangalore - 560003, India Sector-18, Gurugram - 122015
(Haryana), India

SCALE: DATE: REF NO:


NTS INFRA/EN/
JAN 2021
PW/001
REVISION: SIZE:

R1/V2 A3

COPY RIGHTS:
THIS DRAWING IS THE PROPERTY OF JURONG CONSULTANTS (INDIA) PVT. LTD., AND NO DRAWING,
EITHER IN PART OR FULL, SHALL BE REPRODUCED IN ANY MANNER, WHATSOEVER, WITHOUT
WRITTEN PERMISSION FROM JURONG CONSULTANTS (INDIA) PVT.LTD.
EQ

500
5750

LINE
LINEMATCH
LINEMATCH
LINEMATCH
MATCH
694.25 LVL

EQ

600
300
693.75 LVL
5 MTR. LEGEND:

LANDSCAPING

FGL 691.0 LVL INTERNAL


ROAD
OUTER ROAD
RETAINING WALL
Rising Main to ESR
Overflow Pipe

SECTION A-A
Distribution Main
Feeder Main
Scour Pipe
VALVE

· POTABLE WATER GROUND LEVEL STORAGE


RESERVOIR (GLSR-P)

· POTABLE WATER PUMPING STATION (PWPS) GSLR-P

· LAYOUT OF PUMPING STATIONS & ESR'S

NOTES:-
500

1. ALL DIMENSIONS ARE IN MM AND LEVELS ARE IN


M, UNLESS OTHERWISE SPECIFIED.
2. THIS DRAWING SHALL BE MODIFIED BASED ON
5750

THE DETAILED DESIGN FROM DBO CONTRACTOR.


3. LAYOUT DIMENSIONS ARE TENTATIVE. BIDDER
HAS TO ASSESS THE PUMP HOUSE DIMENSION
BASED ON SELECTION OF PUMPS & ELECTRO-
694.25 LVL

600
MECHANICAL EQUIPMENTS.
300

4. BUTTERFLY VALVE SHALL BE CONFORMING TO IS:


13095/AWWA C504 AND NON RETURN VALVE
SHALL BE CONFORMING TO AWWA C508.
5. ALL REDUCERS IN THE SUCTION SIDE ARE
ECCENTRIC TYPE WITH FLAT SIDE UP (FSU) AND
CONCENTRIC TYPE FOR DISCHARGE SIDE.
6. THE MATCHING FLANGES OF THE SUCTION &
DELIVERY PIPELINES SHALL BE MATCH WITH THE
PUMPS FLANGES. (AS PER PUMP SUPPLIERS
DRAWINGS)
7. ALL PIPING SHALL BE M.S BLACK ERW HEAVY
GRADE PIPING AS PER IS: 1239 /IS: 3589
8. THE ULTRASONIC FLOW METER STALL BE
PROVIDED IN TRANSMISSION MAIN WITH
DISMANTLING CONNECTION AND SHALL BE KEPT
IN CHAMBER.
9. Capacity of GLSR Per Unit is 16ML
10. This plot also accommodates recycled water ELSR
supplying for Zone 4

SECTION A-A
MAP TITLE:
GENERAL ARRANGEMENT DRAWING OF
16 ML MODULES FOR GLSR IN ZONE 4

PROJECT INTEGRATED MASTER PLAN & DESIGN


NAME:
FOR HYDERABAD PHARMA CITY
PROJECT CODE: C-IN000117

DELIVERABLE BASIC INFRASTRUCTURE


MILESTONE: CATEGORY A: STAGE 4: Version 2

EQ
500

CLIENT:

TELANGANA STATE INDUSTRIAL


5750

INFRASTRUCTURE CORPORATION
TELANGANA GOVERNMENT UNDERTAKING
SEAL

694.25 LVL

EQ
CONSULTANT:

600
300

SURBANA JURONG
693.75 LVL CONSULTANTS PTE. LIMITED
SINGAPORE
5 MTR. SEAL
SUB-CONSULTANT

JURONG Consultants (India) Pvt. Ltd. SMEC India Pvt. Ltd.

FGL 691.0 LVL (A member of Surbana Jurong) (A member of Surbana Jurong)


41/7, 1st & 2nd Floor, 15th Cross, 1st Floor, Novus Tower, West
MES College Road, Malleswaram, Wing, Plot No. 18,
Bangalore - 560003, India Sector-18, Gurugram - 122015
(Haryana), India

RETAINING WALL SCALE: DATE: REF NO:


NTS INFRA/EN/
JAN 2021
PW/002
REVISION: SIZE:

SECTION A-A COPY RIGHTS:


R1/V2 A3

THIS DRAWING IS THE PROPERTY OF JURONG CONSULTANTS (INDIA) PVT. LTD., AND NO DRAWING,
EITHER IN PART OR FULL, SHALL BE REPRODUCED IN ANY MANNER, WHATSOEVER, WITHOUT
WRITTEN PERMISSION FROM JURONG CONSULTANTS (INDIA) PVT.LTD.
EQ

500
5750

LINE
LINEMATCH
LINEMATCH
LINEMATCH
MATCH
694.25 LVL

EQ

600
300
693.75 LVL
5 MTR. LEGEND:

LANDSCAPING
FGL 690.0 LVL
INTERNAL
ROAD
OUTER ROAD
RETAINING WALL
Rising Main to ESR
Overflow Pipe

SECTION B-B
Distribution Main
Feeder Main
Scour Pipe
VALVE

· POTABLE WATER GROUND LEVEL STORAGE


RESERVOIR (GLSR-P)

· POTABLE WATER PUMPING STATION (PWPS) GSLR-P

· LAYOUT OF PUMPING STATIONS & ESR'S

NOTES:-
500

1. ALL DIMENSIONS ARE IN MM AND LEVELS ARE IN


M, UNLESS OTHERWISE SPECIFIED.
2. THIS DRAWING SHALL BE MODIFIED BASED ON
5750

THE DETAILED DESIGN FROM DBO CONTRACTOR.


3. LAYOUT DIMENSIONS ARE TENTATIVE. BIDDER
HAS TO ASSESS THE PUMP HOUSE DIMENSION
BASED ON SELECTION OF PUMPS & ELECTRO-
694.25 LVL MECHANICAL EQUIPMENTS.

600
4. BUTTERFLY VALVE SHALL BE CONFORMING TO IS:
300

13095/AWWA C504 AND NON RETURN VALVE


SHALL BE CONFORMING TO AWWA C508.
5. ALL REDUCERS IN THE SUCTION SIDE ARE
ECCENTRIC TYPE WITH FLAT SIDE UP (FSU) AND
CONCENTRIC TYPE FOR DISCHARGE SIDE.
6. THE MATCHING FLANGES OF THE SUCTION &
DELIVERY PIPELINES SHALL BE MATCH WITH THE
PUMPS FLANGES. (AS PER PUMP SUPPLIERS
DRAWINGS)
7. ALL PIPING SHALL BE M.S BLACK ERW HEAVY
GRADE PIPING AS PER IS: 1239 /IS: 3589
8. THE ULTRASONIC FLOW METER STALL BE
PROVIDED IN TRANSMISSION MAIN WITH
DISMANTLING CONNECTION AND SHALL BE KEPT
IN CHAMBER.
9. Capacity of GLSR Per Unit is 16ML
10. This plot also accommodates recycled water ELSR

SECTION B-B
supplying for Zone 4

MAP TITLE:
GENERAL ARRANGEMENT DRAWING OF
16 ML MODULES FOR GLSR IN ZONE 4

PROJECT INTEGRATED MASTER PLAN & DESIGN


NAME:
FOR HYDERABAD PHARMA CITY
PROJECT CODE: C-IN000117

DELIVERABLE BASIC INFRASTRUCTURE


MILESTONE: CATEGORY A: STAGE 4: Version 2

EQ
500

CLIENT:

TELANGANA STATE INDUSTRIAL


INFRASTRUCTURE CORPORATION
5750

TELANGANA GOVERNMENT UNDERTAKING


SEAL

CONSULTANT:
694.25 LVL

EQ
600
SURBANA JURONG
300

CONSULTANTS PTE. LIMITED


693.75 LVL SINGAPORE

SEAL
5 MTR. SUB-CONSULTANT

JURONG Consultants (India) Pvt. Ltd. SMEC India Pvt. Ltd.

(A member of Surbana Jurong) (A member of Surbana Jurong)


FGL 691.0 LVL 41/7, 1st & 2nd Floor, 15th Cross,
MES College Road, Malleswaram,
1st Floor, Novus Tower, West
Wing, Plot No. 18,
Bangalore - 560003, India Sector-18, Gurugram - 122015
(Haryana), India

SCALE: DATE: REF NO:


RETAINING WALL NTS
JAN 2021 INFRA/EN/
PW/003
REVISION: SIZE:

SECTION B-B COPY RIGHTS:


R1/V2 A3

THIS DRAWING IS THE PROPERTY OF JURONG CONSULTANTS (INDIA) PVT. LTD., AND NO DRAWING,
EITHER IN PART OR FULL, SHALL BE REPRODUCED IN ANY MANNER, WHATSOEVER, WITHOUT
WRITTEN PERMISSION FROM JURONG CONSULTANTS (INDIA) PVT.LTD.
200THK PCC

LINE
LINEMATCH
LINEMATCH
LINEMATCH
MATCH
LEGEND:

150
LANDSCAPING

INTERNAL
ROAD

450
OUTER ROAD

Rising Main to ESR


Overflow Pipe
Distribution Main
Feeder Main
Scour Pipe
VALVE

· POTABLE WATER GROUND LEVEL STORAGE


RESERVOIR (GLSR-P)

· POTABLE WATER PUMPING STATION (PWPS) GSLR-P

· LAYOUT OF PUMPING STATIONS & ESR'S

NOTES:-

TYPICAL DETAIL OF SUMP 1.

2.
ALL DIMENSIONS ARE IN MM AND LEVELS ARE IN
M, UNLESS OTHERWISE SPECIFIED.
THIS DRAWING SHALL BE MODIFIED BASED ON
THE DETAILED DESIGN FROM DBO CONTRACTOR.
3. LAYOUT DIMENSIONS ARE TENTATIVE. BIDDER
HAS TO ASSESS THE PUMP HOUSE DIMENSION
BASED ON SELECTION OF PUMPS & ELECTRO-
MECHANICAL EQUIPMENTS.
4. BUTTERFLY VALVE SHALL BE CONFORMING TO IS:
13095/AWWA C504 AND NON RETURN VALVE
SHALL BE CONFORMING TO AWWA C508.
5. ALL REDUCERS IN THE SUCTION SIDE ARE
ECCENTRIC TYPE WITH FLAT SIDE UP (FSU) AND
CONCENTRIC TYPE FOR DISCHARGE SIDE.
6. THE MATCHING FLANGES OF THE SUCTION &
DELIVERY PIPELINES SHALL BE MATCH WITH THE
PUMPS FLANGES. (AS PER PUMP SUPPLIERS
DRAWINGS)
7. ALL PIPING SHALL BE M.S BLACK ERW HEAVY
GRADE PIPING AS PER IS: 1239 /IS: 3589
8. THE ULTRASONIC FLOW METER STALL BE
PROVIDED IN TRANSMISSION MAIN WITH
DISMANTLING CONNECTION AND SHALL BE KEPT
IN CHAMBER.
9. Capacity of GLSR Per Unit is 16ML
10. This plot also accommodates recycled water ELSR
supplying for Zone 4

MAP TITLE:
GENERAL ARRANGEMENT DRAWING OF
16 ML MODULES FOR GLSR IN ZONE 4

PROJECT INTEGRATED MASTER PLAN & DESIGN


NAME:
FOR HYDERABAD PHARMA CITY
PROJECT CODE: C-IN000117

DELIVERABLE BASIC INFRASTRUCTURE


MILESTONE: CATEGORY A: STAGE 4: Version 2

CLIENT:

TELANGANA STATE INDUSTRIAL


INFRASTRUCTURE CORPORATION
TELANGANA GOVERNMENT UNDERTAKING
SEAL

CONSULTANT:

3000
SURBANA JURONG
CONSULTANTS PTE. LIMITED
SINGAPORE

SEAL
SUB-CONSULTANT

JURONG Consultants (India) Pvt. Ltd. SMEC India Pvt. Ltd.

(A member of Surbana Jurong) (A member of Surbana Jurong)


41/7, 1st & 2nd Floor, 15th Cross, 1st Floor, Novus Tower, West
MES College Road, Malleswaram, Wing, Plot No. 18,
Bangalore - 560003, India Sector-18, Gurugram - 122015
(Haryana), India

DATE: REF NO:

TYPICAL DETAIL OF MS LADDER


SCALE:

TYPICAL DETAIL OF STARCASE


NTS INFRA/EN/
JAN 2021
PW/004
REVISION: SIZE:

R1/V2 A3

COPY RIGHTS:
THIS DRAWING IS THE PROPERTY OF JURONG CONSULTANTS (INDIA) PVT. LTD., AND NO DRAWING,
EITHER IN PART OR FULL, SHALL BE REPRODUCED IN ANY MANNER, WHATSOEVER, WITHOUT
WRITTEN PERMISSION FROM JURONG CONSULTANTS (INDIA) PVT.LTD.