Terex Aerial
Terex Aerial
Terex Aerial
MODEL TA34
OPERATOR’S
MANUAL
Terex Aerials appreciates your choice of our aerial lift for your application. Our number one priority is user safety,
which is best achieved by our joint efforts.
We feel that you can make a major contribution to safety if you as the equipment user and operator:
2. Read, understand and follow the instructions in this and other manuals supplied with this machine.
4. Have only trained operators - directed by informed and knowledgeable supervision - running the
machine.
If there is anything in this manual that is not clear or which you believe should be added, please send your comments to
the Technical Publications Department, Terex Aerials, Courtstown Industrial Park, Little Island, Co. Cork Ireland.
Telephone: +353-21-353011, Fax: +353-21-353368 or email: nscott@terex.ie
To help you recognize important safety information, we have identified warnings and instructions that directly impact
on safety with following signals:
THESE SYMBOLS MEAN YOUR SAFETY IS INVOLVED! SEE NEXT PAGE FOR SPECIFIC
INFORMATION. READ, UNDERSTAND AND FOLLOW ALL DANGER, WARNING AND CAUTION
DECALS ON YOUR MACHINE.
i Model TA34
Issued 06/99 Rev.0
i-2
INTRODUCTION
“Caution” indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury. It is also used to alert against unsafe practices, and for property-damage-only situations.
The best method to protect yourself and others from injury or death is to use common sense. If you are unsure of any
operation, don’t start until you are satisfied that it is safe to proceed and have discussed the situation with your
supervisor.
Thank you!
Model TA34
Issued 06/99 Rev.0
CONTENTS
SPECIFICATIONS
The TA34 has a working height ability of 12.36 m. The following diagram shows the working envelope
for the TA34. All dimensions are in metres.
SPECIFICATIONS
1.2.3 OIL
SAFETY PRECAUTIONS
· ELECTROCUTION HAZARD! THIS MACHINE IS NOT INSULATED!! Maintain safe clearance from electrical
lines and apparatus. You must allow for machine sway (side to side movement) when elevated, and electrical line
movement. This machine does not provide protection from contact with or proximity to an electrically charged
conductor.
· You must AVOID CONTACT between any part of the machine, or its load, and any electrical line or apparatus carrying
up to 300 volts.
· You must maintain a CLEARANCE OF AT LEAST 10 FEET (3.05 M) between any part of the machine, or its load, and
any electrical line or apparatus carrying over 300 volts up to 50,000 volts. One foot (30.5 cm) additional clearance is
required for every additional 30,000 volts.
· DEATH OR SERIOUS INJURY will result from contact with, or inadequate clearance from, any charged conductor.
· Read and understand all safety and control information found on the machine and in this manual before operating the
unit.
· Only trained, competent personnel should operate the aerial work platform.
· Be aware of all Government and Local rules which may apply to this machine and its safe operation.
2 Model TA34
Issued 06/99 Rev.0
2-2
SAFETY PRECAUTIONS
· Approved safety belts must be worn at all times when operating the unit from the platform. In addition approved
headgear and other protective equipment must be worn as required. (The appropriate equivalent government body
should be consulted).
· NEVER fasten safety belt to an adjacent structure while on the work platform.
· Make sure that entry gate to platform is secured before operating unit from the platform.
· DO NOT block the foot pedal or any function control in the operating position.
· DO NOT exceed the platform capacity of the unit in any configuration. Review the section titled “MACHINE
SPECIFICATIONS”, earlier in this manual, regarding this model’s capacities and dimensions.
· SECURE all tools and other loose items to prevent injury to persons working on or below the work platform.
· DO NOT use scaffolding, ladders or similar items to extend your reach while on the work platform.
· DO NOT attempt to climb down the boom assembly, if the unit fails while the operator’s platform is raised or extended.
· Since the machine may be operated from its ground controls, precautions should be taken to prevent unauthorised
personnel from operating the work platform with the ground controls while the platform is in use.
· The “UNPOWERED EMERGENCY MOVEMENT” procedure (described later in this manual) required releasing the
brakes and disconnecting the rear wheels, which results in there being no means to stop the unit’s travel. Terex
recommends using this procedure only in cases of emergency, and only for a short distance. Be on guard against unit
runaway on sloping surfaces. Movement speed shall not exceed 3 MPH (5 KPH).
Model TA34 2
Issued 06/99 Rev.0
2-3
SAFETY PRECAUTIONS
· DO NOT attempt to open any hydraulic line or component without first relieving system pressures and shutting off fluid
flow from the tank.
· DO NOT allow anyone to tamper with, service or operate the machine from the ground control station while personnel
are on the platform, except in an emergency.
· DO NOT use the aerial work platform outdoors in electrical storms or in high wind situations. Maximum rated wind
speed is 12.5 m/s.
· DO NOT raise the aerial work platform unless the unit is on a firm surface, and slope is within rated slope of the machine.
· When working underneath elevated booms, ensure they are propped using chock provided for this purpose.
· Use caution to prevent ropes, cords, hoses, etc. from becoming entangled in the unit’s boom sections when being raised,
lowered or repositioned.
· Ensure that the area surrounding the mobile platform is clear of personnel and equipment before: driving the unit;
raising, lowering or extending the boom, or swinging the superstructure; or tilting the platform.
· Maintain a safe distance from overhead and ground obstacles, debris, drop-offs, holes, depressions, electrical wires and
other hazards to travel.
2 Model TA34
Issued 06/99 Rev.0
2-4
SAFETY PRECAUTIONS
· Limit travel speed according to conditions of the ground surface, congestion, slope, location of personnel or any other
factors that could cause hazard of collision of injury to personnel.
· DO NOT operate this machine while under the influence of any drugs or alcohol.
· DO NOT operate this machine if you are bothered by heights, seizures, or dizzy spells.
SAFETY PRECAUTIONS
· Complete the “Operational Checklists” found in this manual (see Table of Contents) at designated intervals.
· Always attach the unit to a winch when loading or unloading from a truck or trailer. Terex does not recommend
unassisted loading or unloading of any aerial work platform.
· With the platform swung away from the stowed position, use caution when selecting travel or steering direction. Travel
and steer direction will be opposite to switch or lever movement. Refer to the directional arrow decals on the
undercarriage of the unit for travel orientation.
· Actuation of the red “EMERGENCY STOP” button will apply brakes immediately, causing unexpected platform
movement as the machine comes to a sudden stop. Brace yourself.
· Whenever releasing the brakes, ensure that the unit cannot roll.
· Immediately report any erratic noises, vibrations or malfunctions of the unit to a supervisor. Machine shall be removed
from service until diagnosis and any necessary repairs have been completed.
· Operating this equipment without all safety and control decals in place can be hazardous.
2 Model TA34
Issued 06/99 Rev.0
2-6
SAFETY PRECAUTIONS
· For transporting the machine, the platform or boom must not be tied to the trailer bed in any way.
· DO NOT use the boom or platform as a crane to lift oversized of hanging loads.
· DO NOT raise, extend, retract, tilt, or lower the platform into stationary objects, as this will cause damage to mechanical
and hydraulic components.
· DO NOT use the platform or boom functions to push or tow the unit or another vehicle.
· Avoid sudden braking or steering, go slowly and leave more manoeuvring room during cold weather operation until the
machine is warm.
· Noise emission levels on this machine are less than 70 dB(A). @ 3m.
· WASHING INSTRUCTIONS : Always direct the high pressure jets of water away from the upper control box, and
electric components in general. When cleaning is required, clean with a damp cloth. We recommend that during machine
transport, and while being washed, the upper control box is protected or that the upper control box cover (Part No.
33014-0071) is used..
Model TA34 2
Issued 06/99 Rev.0
2-7
SAFETY PRECAUTIONS
Two EMERGENCY STOP pushbuttons, one at the ground station and one in the cage, act as power on/off switches.
Both switches must be ON to operate the machine. When either of the buttons is depressed, all functions stop
immediately and the parking brake is automatically applied.
The footswitch must be fully depressed before any machine operation can be carried out from the cage.
When the footswitch control is released, the electric supply to the hydraulic pump and the drive function is terminated
and all machine functions stop.
The tilt alarm gives an audible warning when the machine is out of level by more than the degree for which the sensor
has been rated.
SAFETY PRECAUTIONS
Before the TA34 is used at the start of a day, or after an extended period without use, the following checks should be
carried out to ensure that the machine is in good condition and safe to use:
(d) Check that the battery charger is disconnected from the mains supply.
OPERATING PROCEDURES
DO NOT OPERATE THE MACHINE IF THE GROUND CONTROL CHECKS REVEAL A FAULT.
Ensure that the following checks are carried out with the cage empty:
DO NOT OPERATE THE MACHINE IF THE CAGE CONTROL CHECKS REVEAL A FAULT.
Ensure that the following checks are carried out on a level surface:
(a) Carry out the checks described in section 3.2. Carefully observe boom speed.
(b) Check the drive, and emergency braking.
(c) Check the slow drive speed with the lower boom slightly elevated.
(d) Check the fast drive speed with all the booms fully down.
Model TA34
Issued 06/99 Rev.0
3
3-3
OPERATING PROCEDURES
TO AVOID SERIOUS PERSONAL INJURY OR DEATH, ENSURE THAT THE MACHINE IS IN “CREEP “
DRIVE SPEED WHILE UNLOADING FROM A TRUCK OR TRAILER
Inspect the outside of the unit for damage (including the underside). Inspect all hoses, boom sections and cables for
chafing or road damage. Confirm that all swing bearing bolts are tight (refer to specifications).
Unlock and open hydraulic compartment. Inspect all electrical and hydraulic connections for damage and security.
Check fluid level on the hydraulic tank, and add fluid as required (see lubrication chart).
OPERATING PROCEDURES
ALWAYS ATTACH THE UNIT TO A WINCH WHEN LOADING OR UNLOADING FROM A TRUCK OR
TRAILER. CONNECT WINCH TO THE TIE DOWN LUGS ON THE UNDERCARRIAGE. UNASSISTED
LOADING OR UNLOADING OF ANY MOBILE PLATFORM IS NOT RECOMMENDED.
READ AND UNDERSTAND ALL SAFETY, CONTROL AND OPERATING INFORMATION FOUND ON
THE MACHINE AND IN THIS MANUAL BEFORE OPERATING THE UNIT.
Remove all machines tie downs. Remove wheel chocks, if used. Turn the Power On keyswitch to Cage (platform)
position.
Raise the boom so that the platform will clear any obstacles as the machine is driven down the loading ramp.
Carefully drive the unit off the truck or trailer with the assistance of a winch
Note: The brakes are automatically released for driving, and will automatically apply when the unit stops.
Before placing the unit into service, all operators must read and understand the contents of the Operator’s Manual.
Upon initial unloading of the machine the PDI (Pre-Delivery Inspection Form) must be completed and returned in order
to activate the Terex Limited Warranty.
Model TA34
Issued 06/99 Rev.0
3
3-5
OPERATING PROCEDURES
3.5. DRIVING
It should be noted that the machine is not equipped for highway use and should only be driven on the public highway in
compliance with any statutory regulation.
The drive controls are located in the cage and the machine can be driven with the cage positioned at either end of the
machine. If driving is attempted from the ‘steering’ end of the machine, all directions given to the controls will be
reversed so the operator may find driving easier with the cage positioned at the ‘drive’ end. Arrows on the chassis show
the true control direction. Before driving the machine, check the following;
The drive controls are located in the cage and consist of a joystick controller and a footswitch. These controls can be
seen in figure 3.1 (See page 3-8).
(a) Check that power keyswitch at ground controls is switched to cage position.
(b) At the cage controls, set the LIFT/DRIVE selector switch to DRIVE.
(c) Fully depress the footswitch.
(d) With the footswitch depressed, push the joystick forward to drive the machine forward, or pull the
joystick back to drive the machine in reverse.
Note:- These directions are correct when the cage is at the rear of the machine (opposite end to the steered wheels) but
will be reversed if the cage is to the front of the machine (see direction decal on main deck)..
Note:- Speed is proportional to joystick lever movement with the maximum speed being pre-set and automatically
selected to high or low speed depending on whether the booms are stowed or raised.
3 Model TA34
Issued 06/99 Rev.0
3-6
OPERATING PROCEDURES
Note:- The steering is not self centring. The orientation of the steer wheels remains fixed until the steer switch is
operated.
Note:- Ensure that the maximum travel speed is reduced to 0.75kph when the booms are elevated from the stowed
position.
To stop the machine the joystick should be returned to the centre neutral position.
Note:- The machine will not stop instantaneously but will decelerate to a smooth stop whereupon the parking brake will
apply.
SHOULD THE NEED ARISE THE MACHINE CAN BE BROUGHT TO AN ABRUPT STOP BY EITHER
RELEASING THE FOOTSWITCH OR BY PUSHING THE EMERGENCY STOP BUTTON.
Note:- That in these circumstances all of the controls, including steer control, are inoperative.
Model TA34
Issued 06/99 Rev.0
3
3-7
OPERATING PROCEDURES
Never drive from a level surface on to a slope at full speed. Always reduce speed to 1 Km/h when approaching a
slope.
Note:- Battery life will be optimised by smooth use of all drive controls. Continuing to depress the steer rocker switch
when the steer wheels have reached their limit of travel should be avoided as this causes unnecessary battery drain.
Note:- To de-activate the brakes, the footswitch must be depressed and the joystick displaced simultaneously.
Warning::- When descending on a slope it is necessary to move the joystick in the reverse position to offer adequate
braking (plugging).
3 Model TA34
Issued 06/99 Rev.0
3-8
OPERATING PROCEDURES
The drive speed of the machine is proportionally controlled by the amount of movement made to the joystick.
Note:- When elevated, the drive speed of the machine is automatically reduced.
THE WHEELS ARE NOT SELF-CENTRING AND MUST BE ALIGNED BY USING THE JOYSTICK
ROCKER SWITCH
Steering is achieved by depressing the rocker switch on top of the joystick controller to the left or right, as required.
Note: When ascending a slope with low batteries it is possible that steering will not operate. To steer stop driving and
steer as required.
3 Model TA34
Issued 06/99 Rev.0
3 - 10
OPERATING PROCEDURES
The TA34 has a single braking system which serves as a parking brake when the machine is static, and as service brakes
when the machine is in drive mode. The brakes are spring applied and hydraulically released.
The machine will not stop instantaneously but will decelerate to a smooth stop whereupon the parking brake will apply.
The brakes are spring applied when the joystick is in the central (neutral) position and remain applied during lifting
operations. Deceleration is achieved by moving the joystick controller to the central (neutral) position.
Emergency braking is achieved by operating the EMERGENCY STOP button, or by releasing the footswitch.
Model TA34
Issued 06/99 Rev.0
3
3 - 11
OPERATING PROCEDURES
Cage Controls:-
Before entering the cage, the ground controls may be used to bring the cage to the most convenient position for access.
The ground controls should, in any case, be checked as follows:
(a) Ensure that the ground control emergency stop button is out.
(b) Turn the key in the ground controls power selector switch to select cage control. Remove the key.
The operator may then enter the cage.
(c) Ensure that the cage control emergency stop button is out.
(d) Switch lift/drive selector to lift position.
(e) Select required boom on 4 position boom selector switch.
(f) Depress footswitch.
Note:- The footswitch must be activated at all times during cage access functions.
3 Model TA34
Issued 06/99 Rev.0
3 - 12
OPERATING PROCEDURES
Ground Controls:
(a) Ensure that both ground and cage control emergency stop buttons are in the out (released)
“power-on” position.
(b) Insert the key into the control power selector switch and turn to ground control and hold in position
while carrying out the following instructions. (Momentary operation)
(c) Operate boom motions as required by referring to the control panel diagrams, and turning selection
switch in the appropriate direction, hold until required position of booms is reached, all motion will
stop once the switch is released.
(d) When operations at the ground controls are complete turn the power selector switch key to the off
position.
Model TA34
Issued 06/99 Rev.0
3
3 - 13
OPERATING PROCEDURES
OPERATING PROCEDURES
When the machine is no longer required, and is to be stored, the following instructions are recommended.
(Note: Terex Aerials recommends indoor storage of the unit)
Prior to re-using the unit after storage, all daily servicing checks (section 5.3.1) should be fully adhered to. After
prolonged storage, weekly (section 5.3.2) and monthly (section 5.3.3) servicing checks should also be carried out.
Model TA34
Issued 06/99 Rev.0
3
3 - 15
OPERATING PROCEDURES
L1 RED IN WORK
To charge the batteries after they have been fully or partially discharged:
(a) Press emergency stop button and remove key from lower controls.
(b) Plug the battery charger lead (on rear of the chassis) into a power supply.
(c) L7 LED should light to show charger is powered up.
(d) L8 indicates battery is partially discharged and L9 indicates battery is completely discharged.
(e) The LED’s L2-6 shows charging current.
(f) The charger will automatically turn off when batteries are charged.
(g) Machine is fitted with an over-ride to prevent the machine being used while it is being charged.
3 Model TA34
Issued 06/99 Rev.0
3 - 16
OPERATING PROCEDURES
To charge the batteries after they have been fully or partially discharged:
(a) Press the emergency stop button and remove key from lower controls.
(b) Plug the charger into an AC power supply having the same ratings as that of the charger
(100V 60Hz).
(c) The LED on the charger will light, indicating charge current is flowing.
(d) The charger is equipped with an electronic timer. At the battery gassing threshold,
(2.3 volts per cell) the timer will activate and run for three hours. During this period, the batteries
are in a gassing or equalizing mode (205-206 volts per cell maximum).
After three hours the charger will drop the batteries in a low float mode, indicated by a blinking
LED. (2.26 volts per cell). Current in the float mode is less than 1 Amp).
The charger may be left on indefinitely, but water level should be checked periodically on wet
batteries.
(e) To discontinue charging, unplug the AC power cord. Plugging the AC power back in will cause
the charger to repeat the cycle.
Model TA34
Issued 06/99 Rev.0
3
3 - 17
OPERATING PROCEDURES
Important:-
The Battery Discharge Indicator (BDI) is a single piece instrument which combines a battery state of charge indicator
with solid state hour meter.
The LED battery displays consists of 5 green, 3 yellow and ‘flashing’ red LED’s. The first red LED will flash when
battery is within 10% of lockout discharge level, both red LED’s will flash alternatively at lockout. The LCD hour
meter display consists of a flashing hour glass symbol to indicate the hour metre is counting plus six LCD digits to
display 99,999.9 hours to he nearest 0.1 hour (six minutes). The hour meter incorporates a custom CMOS/EEPROM
chip with a 10 year memory retention.
Machine connection is via a locking terminal connector to internationally available standard. Lift lockout at 80%
discharge is effected through a normally closed safety relay. In addition the BDI acts as an ignition warning light. The
10 bar LED of the battery monitor is turned on and off by the key select switch.
It is recommended that the machine is taken out of service as soon as the 2 red flashing LED’s operate flashes and that
the batteries are fully charged before any further machine operations are attempted.
VPC Multiplier
SETTING K L M N O P Q R S T U
VOLTAGE PER CELL 1.57 1.63 1.68 1.73* 1.78 1.82 1.84 1.86 1.89 1.91 1.93
*: Factory setting.
When Battery voltage drops below the preselected value, the normally closed contact between 3 and 4 will open. This
will eliminate the operation of the boom functions when the machine is in a stowed position.
3 Model TA34
Issued 06/99 Rev.0
3 - 18
OPERATING PROCEDURES
BRAKING IN ICY CONDITIONS: WHEN THE GROUND SURFACE IS ICY, CARE MUST BE TAKEN TO
AVOID SUDDEN BRAKING. IT IS RECOMMENDED THAT ALL DRIVING OPERATIONS ARE
CARRIED OUT SLOWLY AND A SAFE MARGIN OF ERROR IS ALLOWED FOR MANOEUVRING
AROUND OBSTACLES. USE JOYSTICK GENTLY TO CONTROL THE MACHINE.
In very cold weather conditions, the hydraulic oil must be allowed to warm before full operation of the machine is
attempted. Regular oil maintenance must be carried out to ensure that the hydraulic oil is kept free from water
contamination. Emulsified water can freeze out of the oil as ice crystals, completely blocking the suction strainer and
causing hydraulic pump damage. To prevent damage to the machine, the following steps should be taken,
(a) Ensure that all control valves operate smoothly and return freely to the neutral position without
sticking.
(b) Ensure that the rotation drive teeth are not blocked by ice.
(c) Ensure that the steering linkages are free from ice and that the steering operates smoothly.
(d) Ensure that the cage floor is free from ice to allow a firm foot-hold without danger of slipping.
Model TA34
Issued 06/99 Rev.0
3
3 - 19
OPERATING PROCEDURES
3.13.1. TOWING
Machine can be towed by slinging chains around suitable support points. Do not exceed 5km/hr while towing the
machine, as wheels may not camber correctly and the traction motor could damaged.
The unit must not be operated in wind speeds which are in excess of 12.5m/sec (28 mph- 45 km/hr). During normal
machine operations, consideration should be given to nearby objects, especially when working in the close vicinity of
buildings and electrical cables. Sudden gusts of wind could cause the machine to sway and trap the operator’s
arms/hands between the cage railing and any obstruction. It is recommended that a reasonable safe distance is kept
between close obstructions and the cage assembly during all machine operations.
The TA40 is fitted with four lifting points in the form of eyes at each corner of the chassis. During lifting operations,
take all instructions from the crane operator. Check identification plate.
Caution:- To prevent damage to the drive motor, do not exceed the specified speeds when driving on slopes.
When moving down slope move stick in reverse direction to motion to offer braking (plugging).
The operator must ensure that speeds are kept within the limits of 5 km/hr (3mph) with booms stowed and 0.75 km/hr
(0.5 mph) with booms elevated.
3 Model TA34
Issued 06/99 Rev.0
3 - 20
OPERATING PROCEDURES
IF THE TILT ALARM SOUNDS WHILST ELEVATED, RETRACT AND LOWER BOOMS AND DRIVE TO
A LEVEL LOCATION.
If a wire in the tilt alarm circuit becomes disconnected whilst the machine is in use, the alarm will sound continuously.
If this occurs when the machine is elevated, zoom in immediately and lower the cage to the stowed position. DO NOT
USE THE MACHINE UNTIL THE FAULT HAS BEEN RECTIFIED.
With key switched on and before you operate the machine, open rear cover and press down one side of sensor. This
will sound the horn after a small time delay, if functioning properly.
If there is no horn sound, the sensor must be repaired immediately before machine can be operated.
Model TA34 4
Issued 06/99 Rev.0
4-1
EMERGENCY PROCEDURES
It is not possible for us to foresee every emergency situation that could arise during operation of this machine.
Information on the following pages describes three typical emergency situations and lists appropriate actions that can be
taken.
· Stay Calm.
· Think through the situation before operating the machine.
· Get help if necessary.
4.1.1 SITUATION: Platform elevated, operator not incapacitated, but unit will not
operate using the platform controls.
POSSIBLE CONDITION:
CORRECTIVE ACTION:
TRY TO DETERMINE THE CAUSE OF THE PROBLEM BEFORE YOU TOUCH THE MACHINE.
CORRECTIVE ACTION:
IMPORTANT: Any incident involving personal injury must be immediately reported to the local Terex Aerials
Distributorship as well as to Terex Aerials Inc.
4.1.3 SITUATION: Platform in contact with live power lines and operator
incapacitated.
CORRECTIVE ACTION:
IMPORTANT: Any incident involving personal injury must be immediately reported to the local Terex Aerials
Distributorship as well as to Terex Aerials Inc.
Model TA34 4
Issued 06/99 Rev.0
4-3
EMERGENCY PROCEDURES
This machine has an emergency hand pump which can be used from the ground control station to operate the machine
when the unit has lost power. The hand pump is located under the valve block. The lever is stowed in the plinth.
EMERGENCY OPERATION:
· Insert handle into handpump (located on rear of plinth).
· Through the aperture in the turn table cover, turn the knob (clockwise) on the desired function until the spool is
shifted (knob stops turning)..
· Operate the hand pump until the boom reaches the desired position. Repear for each boom function.
· Return each knob to its original position after use. (Turn counter clockwise fully).
The emergency rotation of the superstructure can be performed by either mechanical override or the emergency pump.
For the mechanical override procedure, use 1/2” square socket, extension and ratchet handle attached to the square
extension shaft of the rotate drive gearbox.
For the emergency pump procedure, activate the emergency pump and select the screw override.
4 Model TA34
Issued 06/99 Rev.0
4-4
EMERGENCY PROCEDURES
The machine is not designed for sustained towing but may be towed over short distances, at low speed, should the need
arise.
In order to tow the machine it is necessary to disengage the transmission. Doing this also disconnects the brakes so it
is essential that the machine is first secured to prevent injury or damage.
To disengage the transmission and brakes it is necessary to screw the Disengage Plug fully in using of a 6mm hexagon
(Allen) key, turning it clockwise (as in Figure 4.1)
To re-engage the transmission, the same plug is screwed anti-clockwise, until it is fully out.
Having disengaged the transmission the machine may be moved using a suitable vehicle or winch, pulling the machine
from the slinging eyes on the chassis.
NOTE: At no time should the speed exceed 5 km/hr, (3 mph).
On downhill slopes it may be necessary to use a further vehicle to prevent run away.
It is very important that the transmissions is fully re-engaged otherwise the gear box will be damaged.
Model TA34 4
Issued 06/99 Rev.0
4-5
EMERGENCY PROCEDURES
Emergency lowering may be necessary in the unlikely event of a power failure or due to failure of the cage controls.
The ground controls should be tried first and only if these are also inoperative should the emergency lowering system
be used.
When using the emergency lowering system, the lower boom should be lowered first as follows:-
· Select lower boom override on manifold block
· Pump emergency hand pump
After lowering the lower boom the other booms may be lowered in the same way, by selecting the desired function.
NOTE: DESELECT THE PREVIOUS FUNCTION BEFORE SELECTING THE NEXT (unscrew selection
knob)
NOTE: That if emergency lowering is necessary due to pump or hose failure but the controls themselves
remain operative then it is possible to lower the booms using the emergency hand pump in conjunction with either the
upper or lower controls as follows:
CAUTION: If a machine fault necessitates the emergency lowering of the unit then the platform must be
examined by a fully trained technician before the machine is returned to service.
DO NOT USE THE PLATFORM UNTIL IT HAS BEEN ESTABLISHED WHY THE EMERGENCY
FUNCTIONS HAD TO BE USED.
Model TA34
Issued 06/99 Rev.0
5
5-1
MAINTENANCE SCHEDULES
5.1.1. INTRODUCTION
The TA34 has been specially designed to reduce maintenance to a minimum. It is essential that the specified servicing
instructions are followed to ensure safety and reliability.
The hydraulic pump, motor, cylinders and pressure valves are self-lubrication internally. The turntable slewing ring is
grease packed and the corrosion-resistant pivot pins and bearings are pre-lubricated and require attention only at six
monthly intervals.
Note:- During the guarantee period, minor oil leaks may occur until the various hydraulic components and pipe
fittings are “bedded-in”. During the first three months of operational use, all hydraulic components, hoses and pipe
fittings must be inspected weekly for oil leaks etc. Corrective action should be taken as required.
The following table lists the recommended equivalent hydraulic oils for a TA40 machine
If a lubricant not listed in the table is to be used, the oil must comply with the following requirements:-
(a) Highly refined mineral oil incorporating anti-oxidant, anti-dust, anti-foam, and anti-wear additives.
(b) The oil must have good demulsibility, so that water is not circulated in the system.
(c) The optimum viscosity range at operating temperature is 16/40 centi Stokes.
(d) The viscosity index should preferably be 100, and not less than 90.
5 Model TA34
Issued 06/99 Rev.0
5-2
MAINTENANCE SCHEDULES
(f) Mineral hydraulic oils produced by different companies will usually mix with each other
satisfactorily. However, the oil producers should be consulted in case of doubt.
(g) For sub-zero temperatures, the use of Shell Tellus T15 or equivalent hydraulic fluid with viscosity
index of 151E and pour point MINUS 50°C is recommended.
(h) For tropical temperatures, the use of BP Energol HLP 100 or equivalent is recommended.
REGULAR CONTACT WITH MINERAL OILS POSES A POTENTIAL HAZARD TO HEALTH. ALL
PERSONS MUST BE AWARE OF THE CORRECT METHODS OF HANDLING THE OIL AND THE NEED
FOR THOROUGH HYGIENE.
Mineral oil act as solvents on the natural oil in the skin. Frequent and prolonged skin contact can cause dermatitis or
severe irritation. Normally, mineral hydraulic oils present no health hazard when used intelligently and it is
recommended that protective clothing and proper washing facilities should be provided or be accessible.
If oil is splashed into the eyes, it must be washed out thoroughly using copious quantities of water. If irritation persists,
medical advice must be sought.
Model TA34
Issued 06/99 Rev.0
5
5-3
MAINTENANCE SCHEDULES
5.2.1. DAILY
MAINTENANCE SCHEDULES
5.2.2 WEEKLY
In addition to the daily checks, the following checks should be carried out by an experienced technician :-
5.2.3 MONTHLY
MAINTENANCE SCHEDULES
5.2.5 YEARLY
(a) Check zoom cylinders. The zoom cylinder is a double-acting type and must be removed from the
machine before any thorough check can be carried out.
(b) Grease slewing ring bearing.
(c) Examine the hydraulic oil. Change if necessary.
(d) Check hydraulic oil tank.
(e) Examine machine structure for defects.
(f) Examine cage mountings and structure.
MAINTENANCE SCHEDULES
5.3. SERVICING
Before checking the oil level, ensure that the machine booms are stowed in the travelling position and the machine is
standing on level ground. The oil level must be visable on the dip stick. Refer to the lubrication chart for the correct
grade of oil if the reservoir requires topping up.
After checking the oil level, ensure the oil filler cap is fully secure to prevent water contamination or contamination by
other impurities .
(a) Pressurise the hydraulic circuit and inspect the system for any signs of oil leakage, particularly at
flexible hoses, connections and hydraulic components.
(b) Examine all pivot pins on booms, cylinders and the levelling system to ensure that they are
positively secured in position.
5.3.2.2. Steering
Check the steering cylinder for oil leakage and the linkage for signs of wear.
Model TA34
Issued 06/99 Rev.0
5
5-9
MAINTENANCE SCHEDULES
MAINTENANCE SCHEDULES
5.3.3.3. Lubrication
Lubricate all small pivots throughout the machine with any good quality medium grade oil.
(a) Examine both levelling cylinders, particularly at the pivot points, for any sign of wear or damage.
Ensure that the end fittings are secure.
(b) Check cylinders and hose fittings for leaks.
(a) Hydraulically test the cylinders at fully retracted and extended positions, Check that there is no
movement between rod and bearing housing, or between cap and tube
(b) Check all cylinders for oil leakage.
MAINTENANCE SCHEDULES
(a) Ensure that the oil temperature is sufficiently high to allow the oil to flow freely.
(b) Place a suitable container under the drain tap or attached to a suitable hose to lead from the drain
tap to the waste oil container.
(c) Remove drain plug.
(d) Remove the filler breather cap for internal inspection and cleaning.
(e) Renew or clean the suction hose and replace drain plug.
(f) Replace the filler breather cap.
Note:- The following recommendations are based on the advice of suppliers and the requirements of various national
safety regulations. They should be applied with discretion, depending on such factors as the amount and type of use,
environmental conditions, local safety regulations etc.
Note:- In tropical climates, pins and bearings may require more frequent lubrication.
The recommended lubricant for pivot pin bearings is MALACHITE LONGTERN 2 PLUS extreme pressure grease or
equivalent.
Note:- There are no grease nipples for Boom pin bearing lubrication. The pins must be removed and lubricated by
hand.
Cylinder pins are lubricated by greased nipples. These should be greased weekly or every 100 hrs.
(a) Support the boom and upper structure securely on a fork lift, or similar rigid platform.
(b) Remove the pin locking bolts, pull out the buck pin.
(c) Drive out the boom pin. Take care to ensure that the inside bore is not damaged during this
procedure.
(d) Fit new pin and refit buck pin and locking bolt. Lubricate the bolts before fitting.
Note:- It is very important to maintain the correct mating position between the boom and side plates during this
operation. Any movement between the two parts will make pin fitting more difficult.
MAINTENANCE SCHEDULES
(a) Support the tie-rail securely on a fork lift, or similar rigid platform. Or tie to adjacent boom.
Note:- On removal of the pin, the tie-rail will fall from position if not held. Since the tie-rail is a relatively light
components, it can be held in position manually while the new pin is fitted.
(b) Remove the pin locking bolt, pull out the buck pin.
(c) Drive out the boom pin. Take care to ensure that the inside bore is not damaged during this
procedure.
(d) Apply grease to the pin.
(e) Fit new pin and refit buck pin and locking bolt. Lubricate the bolts before fitting.
Note:- If the zoom has been greased, the location recess may be filled and not visible.
Note:- The zoom boom must be secured fully in to prevent the zoom inner from sliding out without the constraint of
the zoom cylinder.
a) Support the inner zoom boom. Unscrew the pad holding screws and pull pads out of boom.
b) Replace the pads by tapping gently into place.
c) Replace holding screws and tighten into position.
a) Extend the inner zoom boom until the front mount of the Tele-cylinder is accessible.
b) Remove one Circlip from end pivot pin, drive out pin.
c) Pull the inner boom backwards, until the pads are accessible at the rear of the zoom boom.
d) Replace the pads and re-assemble the inner zoom boom in the reverse order.
MAINTENANCE SCHEDULES
Note:- It is recommended that the bearing ring at the base of the piston rod is replaced when seals are replaced.
Examine the rod of score marks and damage. This is most easily achieved by extending the cylinder and examining the
protruding rod.
(d) Replace the seals in the end cap and replace the end cap. Care should be taken during this
procedure to ensure that no damage occurs to the rod surface.
(e) Bleed the cylinder by allowing air to escape around the end cap threads.
(f) Fully tighten the end cap.
(g) Clean the over-centre valves and examine for signs of leakage.
(h) Check for efficiency, by extending the cylinder and selecting descent, via the spool valves at either
cage of ground.
5.4 LUBRICATION
The following table lists the recommended lubricants for the TA40:
Hydraulic Oil TEXACO RANDO Check weekly Fill to 1 inch (2.54cms) below
HDZ 32 or Change yearly top of dip stick
equivalent -
refer to section 1
MAINTENANCE SCHEDULES
Note:- The slewing ring should be rotated through 360o after the lubrication operation and the lubricants should then
be topped up.
Terex Aerials Limited recommend the following grease for the slew gear.
It is possible to use other brands of grease provided that they offer greasing characteristics similar to the type listed
above.