General-Purpose Relay G2Rs: Ordering Information
General-Purpose Relay G2Rs: Ordering Information
General-Purpose Relay G2Rs: Ordering Information
RC+EW
Ordering Information
Classification
C ass ca o Degree
eg ee of
o Coil ratings
Co a gs Contact form
t ti
protection SPST-NO SPDT DPST-NO DPDT
Plug-in
ug General-purpose Unsealed
U sea ed AC/DC
C/ C --- G2R-1-S --- G2R-2-S
t
terminal
i l LED indicator --- G2R-1-SN --- G2R-2-SN
LED indicator with --- G2R-1-SNI --- G2R-2-SNI
test button
Diode DC
C --- G2R-1-SD --- G2R-2-SD
LED indicator and --- G2R-1-SND --- G2R-2-SND
diode
LED indicator and --- G2R-2-SNDI --- G2R-2-SNDI
diode with test
button
Plug-in
ug General-purpose AC/DC
C/ C G2R-1A3-S G2R-13-S --- ---
t
terminal
i l LED indicator G2R-1A3-SN G2R-13-SN --- ---
(Twin
crossbar LED indicator and DC G2R-1A3-SND G2R-13-SND --- ---
contact) diode
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A 12 VDC
Rated coil voltage
2
G2RS G2RS
Specifications
Coil Ratings
Rated voltage 12 VAC 24 VAC 100/ 120 VAC 200/ 220 VAC 230 VAC 240 VAC
(110) VAC (220) VAC
Rated current* 50 Hz 93 mA 46.5 mA 11 mA 9.3 mA 5.5 5.1 mA 4.7 (3.7) 4.7 mA
(4.0) mA mA
60 Hz 75 mA 37.5 mA 9/ 7.5 mA 4.5 4.1 mA 3.8 (3.1) 3.8 mA
(10.6) mA (5.3) mA mA
Coil resistance* 65 Ω 260 Ω 4,600 Ω 6,500 Ω 20,200 25,000 Ω 26,850 30,000 Ω
(25,000) Ω (30,000) Ω
Coil inductance Armature OFF 0.19 0.81 13.34 21 51.3 57.5 62 65.5
(H) (ref. value) Armature ON 0.39 1.55 26.84 42 102 117 124 131
Must operate voltage 80% max. of rated voltage
Must release voltage 30% max. of rated voltage
Max. voltage 110% of rated voltage
Power consumption Approx. 0.9 VA at 60 Hz (approx. 0.7 VA at 60 Hz)
Note: 1. Rated voltage of bifurcated crossbar contact type: 100/(110) VAC, 200/(220) VAC, 230 VAC (Approx. 0.7 VA at 60 Hz)
2. Depending on the type of Relay, Some Relays do not have coil specifications. Contact your OMRON representative for more de-
tails.
Rated voltage 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC 100 VDC
Rated current* (50/60 Hz) 106 mA 88.2 mA 43.6 mA 21.8 mA 11.5 mA 5.3 mA
Coil resistance* 47 Ω 68 Ω 275 Ω 1,100 Ω 4,170 Ω 18,860 Ω
Coil inductance Armature OFF 0.20 0.28 1.15 4.27 13.86 67.2
(H) (ref. value) Armature ON 0.39 0.55 2.29 8.55 27.71 93.2
Must operate voltage 70% max. of rated voltage
Must release voltage 15% min. of rated voltage
Max. voltage 110% of rated voltage
Power consumption Approx. 0.53 W
3
G2RS G2RS
Contact Ratings
Plug-in Terminal Relays
Number of poles 1 pole 2 poles
Load Resistive load Inductive load Resistive load Inductive load
(cosφ = 1) (cosφ = 0.4; L/R = 7 ms) (cosφ = 1) (cosφ = 0.4; L/R = 7 ms)
Rated load 10 (1) A at 250 VAC; 7.5 A at 250 VAC; 5 A at 250 VAC; 2 A at 250 VAC; 3 A at
10 (1) A at 30 VDC 5 A at 30 VDC 5 A at 30 VDC 30 VDC
Rated carry current 10 (1) A 5A
Max. operating voltage 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. operating current 10 (1) A 5A
Max. switching 2,500 (250) VA, 1,875 VA, 1,250 VA, 500 VA,
capacity 300 (30) W 150 W 150 W 90 W
Min. permissible load 100 mA at 5 VDC (1 mA at 5 VDC) 10 mA at 5 VDC
Note: 1. P level: λ60 = 0.1 x 10-6/operation
2. ( ): Twin crossbar contact type.
Characteristics
Standard Relays
Item 1 pole 2 poles
Contact resistance 30 mΩ max. 50 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*; contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts 3,000 VAC, 50/60 Hz for 1 min between
of same polarity contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between
contacts of same polarity
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 200 m/s2 when energized (approx. 20G); 100 m/s2 when no energized (approx. 10G)
Life expectancy Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature Operating: –40°C to 70°C (with no icing)
Storage: –40°C to 70°C (with no icing)
Ambient humidity Operating: 35% to 85%
Storage: 35% to 85%
Weight Approx. 17 g (plug-in terminal: approx. 20 g)
Note: Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
4
G2RS G2RS
Approved Standards
UL 508 (File No. E41643)
Model Contact form Coil ratings Contact ratings
G2R-1-S SPDT 5 to 110 VDC 10 A, 30 VDC (resistive)
5 to 240 VAC 10 A,, 250 VAC (general
(g use))
TV 3 (NO contact
TV-3 t t only)
l )
G2R-1A-S SPST-NO
G2R-2-S DPDT 5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
5
G2RS G2RS
Engineering Data
Max. Switching Capacity
Plug-in Relays
G2R-1-S G2R-2-S G2R-13-S, G2R-1A3-S
AC inductive load AC
DC
resistive load
DC DC inductive load
resistive load (L/R = 7 ms)
DC inductive load
(L/R = 7 ms) DC inductive load DC resistive load
(L/R = 7 ms)
Life Expectancy
Plug-in Relays
G2R-1-S G2R-2-S G2R-13-S, G2R-1A3-S
Life expectancy (x103 operations)
5,000
5,000 7,000
5,000
3,000
250-VAC/30-VDC
250-VAC/30-VDC
1,000 resistive load
resistive load
1,000 1,000
500 250-VAC inductive load 700
30-VDC inductive load (L/R = 7ms)
(cosφ = 0.4) 500
500 250-VAC/30-VDC
resistive load 300
DC coil
AC coil
6
G2RS G2RS
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
29 max.
DPDT Relays
Terminal Arrangement/Internal Connections
G2R-2-S, G2R-2-SD, G2R-2-SN, G2R-2-SNI, G2R-2-SNDI (Bottom View)
G2R-2-SND 13 max. G2R-2-S G2R-2-SN G2R-2-SNI (AC)
2.5
29 max. (12.5)*
(28.5)* 10 1 2 3 4 1 2 3 4
2
28 max. 8 7 6 5 8 7 6 5
(27.0)* 20
7
G2RS G2RS
3.2-dia.
4 (11) hole
(14) 2
39.5
3 (12)
85.5 max. 35.5 39.5±0.1
3.5-dia.
hole M3 or
5 3.5-dia.
(A1) hole
1
(A2)
11.5
16.0 max. 61 max.
Note: Pin numbers in parentheses apply to DIN standard.
35.5
85.5 39.5±0.1
max.
8 (A1)
3.5-dia. hole M3 or
1 3.5-dia.
(A2)
hole
5 11.5
61.0
max.
16.0 max.
P2RF-05 2
7 Terminal Arrangement Mounting Holes
Five M3.5 x 8
(for Surface Mounting)
4-dia. holes 4.2-dia. hole
30±0.05
19.5
4 M3 or 3.2-dia.
19.5 max. 30 max.
hole
54 max.
P2RF-08
2 Terminal Arrangement Mounting Holes
7
Eight M3.5 x 8 (for Surface Mounting)
4-dia. holes
4.2-dia. hole
30±0.05
19.5
4 30 max.
19.5 max. M3 or 3.2-dia.
54 max. hole
8
G2RS G2RS
1.5 4
(5)
7 4
7
36 max.
P2R-08P (2-pole)
Terminal Arrangement Mounting Holes
4 14.5 max.
7
0.3
7.5 Eight 1.3-dia. holes
5
5
35.5 max. 5
20
1 5
2.8 20
1.5
(4.3)
7.5
P2R-05A (1-pole)
5
7 14.5 max.
0.3 1.2
Terminal Arrangement
6.7
3.8
16.7 5 35.5 max.
Panel Cutout
Five 3 x 1.8-dia. holes
13.6±0.1
6
30.5±0.2
P2R-08A (2-pole)
7 7 14.5 max.
1.2
0.3
5 Recommended thickness of
the panel is 1.6 to 2.0 mm
5
35.5 max.
20
2.8 2.6
2.8
7.5
9
G2RS G2RS
G2R Relay
G2R Relay
36 P2R-_P
Socket 30 P2R-_A
Socket
Mounting Tracks
PFP-100N, PFP-50N PFP-100N2
16
7.3±0.15
4.5
4.5
27±0.15 35±0.3 27 24 29.2
35±0.3
15 25 25 25 25 * 15 25 25 25 25 15 1 1.5
1 10 10
10 10 L
L
L: Length
1m PFP-100N
50 cm PFP-50N
1m PFP-100N2
1
50 35.5 35.3 34.8
1.8 44.3
11.5 1.3
10M4 x 8 pan
head screw 4.8
16.5
Mounting Plates
P2R-P
90
R2.25 10 elliptic 4.5 13.6
holes
3.4
49 42±0.1 30.5
Square hole
9±0.1 18±0.15 18±0.15 9±0.1
18±0.15 18±0.15
72±0.2 t = 1.6 mm
10
G2RS G2RS
11
G2RS G2RS
Cat. No. J114-E1-1A In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
C&C Components Division H.Q.
Relay Division
28th Fl., Crystal Tower Bldg.,
1-2-27, Shiromi, Chuo-ku,
Osaka 540-6028 Japan Printed in Japan
Phone: (81)6-949-6125 Fax: (81)6-949-6134 1098-4M (0898) a
12