Pressure Switch For Industrial Applications Model PSM-520
Pressure Switch For Industrial Applications Model PSM-520
Pressure Switch For Industrial Applications Model PSM-520
Pressure switch
For industrial applications
Model PSM-520
WIKA data sheet PV 35.01
Applications
■ Pumps
■ Compressors
Special features
■ Adjustable on site
■ Protection cap for switch point setting
■ Setting ranges:
-0.4 ... +7 to 6 ... 30 bar
-6 ...100 to 85 ... 425 psi
-0.04 ... +0.7 to 0.6 ... 3 MPa
■ Electrical rating up to AC 230 V, 50/60 Hz, 10 A
Description
1) Switch point and reset point have to be within the setting range
2) The difference between the switch point and the reset point is also known as switch hysteresis
NO Normally open
p NC
p Pressure 2
3) Single pole double throw
Electrical rating 1 3
3 NO Normally open
Inductive load AC 230 V, 50/60 Hz 6A
AC-15 GND Ground connection
Electrical connection
Rubber grommet for cables ∅ 6 ... 14 mm [∅ 0.24 ... 0.55 in]
Operating conditions
Ingress protection per IEC/EN 60529
Permissible temperature ranges IP30
Ambient: -40 ... +70 °C [-40 ... +158 °F] The ingress protection is only valid if all mounting holes on
Medium: -20 ... +100 °C [-4 ... +212 °F] the rear of the instrument are covered, or for panel mounting
Storage: -20 ... +80 °C [-4 ... +176 °F] on flat surfaces.
Materials
Wetted parts
Bellow: Copper alloy CuSn6 per EN 1652
Process connection: Free cutting steel EN1A per
EN 10277-3, tin-plated
Approvals
Logo Description Country
EU declaration of conformity European Union
■ Low voltage directive
■ RoHS directive
Mounting
Mounting option
Direct mounting Panel mounting
104
±1 3 mounting holes ∅ 5.2 mm [0.2 in] on the
[4.1] rear of the instrument
±1
76.5 48
±2 [3] [1.9]
H
Electrical connection
±1
52
[2.04]
Weight: approx. 530 g [18.7 oz]
Process connection: G ¼ B
L2
L1
D
G
D1
1) SW = spanner width
D1
1) SW = spanner width
Ordering information
Model / Setting range / Process connection
© 02/2018 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
03/2020 EN