f′c = 5000 psi 28IT52 52 36/16 880 204,884 20.76 9869 6558 917
fpu = 270,000 psi 28IT56 56 40/16 928 255,229 22.48 11,354 7614 967
½ in. diameter,
low-relaxation strand 28IT60 60 44/16 976 312,866 24.23 12,912 8747 1017
1. Check local area for availability of other sizes.
2. Loads shown include 50% superimposed dead load and 50% live load. Top tension stress at trans-
fer has been allowed to exceed 6 fc' ; therefore, top reinforcement is required.
Key 3. Loads can be significantly increased by use of structural composite topping.
6510 – Superimposed service load capacity, lb/ft
0.2 – Estimated camber at erection, in.
0.1 – Estimated long-time camber, in.
Strength is based on strain compatibility; bottom tension is limited to 12 fc' ; see pages 3−8 through 3−11 for explanation.