You are on page 1of 3

Innovations in instrumentation for control, test and measurement

IR-Opflow PVDF Precision Flowmeters

Corrosion resistant flow sensor


Manufactured in PVDF (polyvinylidene fluoride) the
IR-Opflow Sensor is a precise volumetric flow meter.
Incoming liquid is forced into a twisting motion by
spiral surfaces molded into the inflow section. This
causes a miniature rotor to turn, virtually friction
free. Each time the rotor spins, the blade interrupts a
beam of infrared light generating a series of pulses
that can be measured.
The precision of the IR-Opflow is not influenced
by either the pressure or volume variations.
The patented rotor design prevents air or gas bub-
bles from becoming trapped in the flowtube,
making the IR-Opflow flowsensor not only rugged but
extremely accurate.

Typical features: Technical Specifications:


• Manufactured in PVDF (polyvinylidene fluoride) Accuracy: 10 Series ±1% of meas. value
• Measuring range: 0.1-120 l/min. through six sizes 30 Series ±3% of meas. . value
• Threaded or Hose Barb connections Repeatability ±0.1% of measured value
• Accuracy: ±1% or ±3% of measured value Flow range: See specifications
• Repeatability: ±0.1% of measured value Temperature range: -40 to 85˚C (-40° to 185° F)
• Square wave Vdc frequency output Maximum pressure: 150 psi
• Patented design and lightweight rotor minimizes Process connection: NPT, BSP or flexible hose
wear, provides friction free rotational movement fitting, see table 1 and 2
• Mountable in any position Materials: All wetted parts PVDF

Electrical Specifications:
Specifications:
Power supply: 5 - 12 Vdc, 6 - 24 mA
Type Flow range K-factor<5cSt Output 8 - 24 Vdc, 18 - 30 mA
lpm (gpm) pulses/l Hz Pulse output: Push-Pull
1 0.1-2.0 (0.03-0.53) 36,000 60-1200 Max. load: 2k2 Ohm
2 0.3-9.0 (0.08-2.38) 8,000 40-1200 Frequency: 15-1,200 Hz , see specifications
3 0.5-15.0 (0.13-3.96) 3,200 26.66-800 Signal cable: 3 feet, other lengths on request
4 1.0-30.0 (0.26-7.93) 1,200 20-600
Signal source: Opto-electronic (infrared)
5 2.5-75.0 (0.66-19.8) 450 18.75-562
6 4.0-120.0 (1.06-32.0) 225 15-450

JLC International Phone: 800 599 4732 www.jlcinternational.com


948 Lenape Drive Town Center 215 340 2650
New Britain, PA 18901 Fax: 215 340 3670 jlcusa@jlcinternational.com
Optional cartridge model features
• Turbine meter accuracy with convenience of non-
intrusive unit for cleaning
• Rotor assembly removable for cleaning
or replacement of flow tube
• Patented design with ±1% or ±3% accuracy
• Accuracy guaranteed when replacing cartridge
• Electronics unaffected by replacement

Cartridge specifications:
Accuracy: 10 Series ±1% of meas. value
30 Series ±3% of meas. value
Repeatability: ±0.1% of measured value
Flow range: Type 1, 2 and 3
Temperature range: -40 to 85°C (-40 to 185°F)
Maximum pressure: 150 psi
Process connection: Flexible hose fitting, (o.d. 9mm)
Materials: All wetted parts are PVDF

Electrical specifications:
Power supply: 5 - 12 Vdc, 6 - 24 mA
Pulse output: Push-Pull
Max. load: 2k2 ohms
Frequency: 26.66 - 1,200 Hz, see specifications

Table 1 Table 2
NPT or BSP Dimensions (mm) Flexible hose fittings Dimensions (mm)
Type A D d L Type A D E F G H I Tot L.
1 9.5 1/4" 6.5 39 1 9.0 M12x1.5 8.7 1.5 6.5 6.9 39 96
2 12.7 1/2" 13.0 47 2 12.0 M20x2 16.0 1.8 12.0 9.0 43 112
3 12.7 1/2" 13.0 47 3 12.0 M20x2 16.0 1.8 12.0 12.0 43 116
4 18.5 3/4" 17.0 63 4 16.0 M27x2 21.0 2.3 16.0 16.0 57 136
5 24.5 1 1/4" 29.0 80 5 16.5 BSP 1”pl. 29.4 1.6 24.5 19.5 80 182
6 24.5 1 1/4" 29.0 80 6 16.5 BSP 1”pl. 29.4 1.6 24.5 24.5 80 183

JLC International Phone: 800 599 4732 www.jlcinternational.com


948 Lenape Drive Town Center 215 340 2650
New Britain, PA 18901 Fax: 215 340 3670 jlcusa@jlcinternational.com
IR-Opflow Filters Ordering information
Type 2-3 IR-Opflow XX X X X X
Accuracy
10 = ±1% of measured value
30 = ±3% of measured value
~115 Output signal
0 = square wave pulse
5 = sinusoidal pulse
Type 1

Type
1 = 0.1 - 2.0 lpm (0.03 - 0.53 gpm) *)
2 = 0.3 - 9.0 lpm (0.08 - 2.38 gpm) *)
70 3 = 0.5 - 15.0 lpm (0.13 - 3.96 gpm) *)
~130
4 = 1.0 - 30.0 lpm (0.26 - 7.93 gpm)
5 = 2.5 - 75.0 lpm (0.66 - 19.8 gpm)
Technical specifications: 6 = 4.0 - 120.0 lpm (1.06 - 32.0 gpm)

Connections: Filter 1 (A) M12 x 1.5 F (fits


flowmeter type 1) Supply voltage
and flexible hose fitting; 0 = 5 - 12 Vdc, 6 - 24 mA
(B) Flexible hose fitting 1 = 8 - 24 Vdc, 18 - 30 mA
on both sides
Filter 2/3 Flexible hose fitting on Process connection
both sides
Mesh width: 100 Micron N = NPT
Pressure drop filter: See graph H = Flexible hose fitting
Filter housing material: PVDF B = BSP
Filter material: PFA S = Metric Thread
'O'- ring material: Viton *) Available in cartridge design, "H" only
Examples:
100.10H
p.m. bar ±1%, square wave, type 1, 5 - 12 Vdc, Hose barbs
150
300.41N
±3%, square wave, type 4, 8 - 24 Vdc, NPT
100

50
Pressure Loss Curve

1 2 3 4 5 6 7 8 9 10

JLC International Phone: 800 599 4732 www.jlcinternational.com


948 Lenape Drive Town Center 215 340 2650
New Britain, PA 18901 Fax: 215 340 3670 jlcusa@jlcinternational.com