Scania DC16 XPI Service & Operator Manual - EN
Scania DC16 XPI Service & Operator Manual - EN
Scania DC16 XPI Service & Operator Manual - EN
WARNING!
This warning symbol and text can be found next to those maintenance items where it is particularly impor-
tant to bear in mind the risk of injury.
Operator's manual
DC16
XPI
Industrial engine
en-GB 2 428 293
Issue 4.0
IMPORTANT!
The owner is responsible for making sure that maintenance is carried out on time and in accordance with
the instructions.
The owner must entrust the maintenance, renewal and repair of emission-related components and systems
to a qualified workshop or person.
Start-up Report – Warranty
The warranty starts when the start-up report has been filled in and sent to Scania. The normal warranty pe-
riod is 1 year, but other conditions can apply.
Fill in the particulars in the start-up report below as well. This can make things easier if you need to contact
a workshop, for example.
Signature
Engine type
Variant
Engine type and variant are indicated on the engine data plate.
Introduction
This Operator's manual describes the operation
and maintenance of Scania industrial engines.
The engines are direct-injection, liquid-cooled,
four-stroke, turbocharged diesel engines. Certain
engines are also equipped with an SCR system
for emission control.
The engines are available with different output
and engine speed settings. Engine power for the
engine ordered is indicated on a plate located on
the engine control unit.
Note:
Only standard components are described in the
operator's manual. Information about special
equipment is contained in instructions from the
various manufacturers.
At the same time, we have been able to maintain Block the starting device when working on the
a high level of performance and operating econ- engine. If the engine starts unexpectedly, there is
omy for Scania Industrial and Marine Engines. a serious risk of injury.
To maintain these throughout the entire service
life of the engine, it is important for the user to
follow the instructions on running, maintenance
and fuel and lubricating oil as outlined in the Op-
erator's manual. Important!
Other green initiatives taken include ensuring Advisories preceded by Important! warn of
that, following maintenance and repair, waste faults and incorrect operation that could lead to
that is harmful to the environment (for example equipment being damaged. Example:
oil, fuel, coolant, filters and batteries) is disposed
of accordance with the applicable environmental IMPORTANT!
requirements.
For Scania to guarantee that the engine corre-
sponds to its certified configuration, and take re-
Safety sponsibility for any damage and injuries that
occur, maintenance must be carried out as above.
The following pages contain a summary of the
safety precautions to be complied with when op-
erating and maintaining Scania engines. The
equivalent text can also be found under the rele-
vant maintenance item.
To prevent damage to the engine and to ensure
that it runs optimally, follow the instructions in
the warnings and advisories.
If the instructions are not followed, the warranty
can cease to apply.
WARNING! WARNING!
Only start the engine in a well ventilated area. The engine must not be run in environments
The exhaust gases contain carbon monoxide and where there is a risk of explosion, as all of the
nitrogen oxides, which are toxic. electrical or mechanical components can gener-
ate sparks.
If it is run in an enclosed space, there should be
an effective device to extract exhaust gases and Approaching a running engine always poses a
crankcase gases. safety risk. Parts of the body, clothes or dropped
tools can get caught in rotating parts such as the
fan and cause injury. For personal safety all ro-
tating parts and hot surfaces must be fitted with
guards.
Starter lock
IMPORTANT!
If the control panel is not fitted with a starter Safety precautions for handling ma-
terials
lock, the engine compartment should be locked
to prevent unauthorised personnel from starting Fuel and lubricating oil
the engine. Alternatively, a lockable master
switch or battery master switch can be used.
WARNING!
Batteries Reductant
WARNING! WARNING!
The batteries contain and form oxyhydrogen gas, Reductant (AdBlue/DEF) is used in the reductant
particularly during charging. Oxyhydrogen gas tank on engines equipped with an SCR system.
is flammable and highly explosive. Avoid contact with the skin.
There must be no smoking, naked flames or If reductant comes in contact with the skin: Wash
sparks near the batteries or the battery compart- with soap and plenty of water. If reductant
ment. Incorrect connection of a battery cable or splashes in the eyes: Rinse immediately with
jump lead can cause a spark, which can cause the plenty of water. Contact a doctor if it is ingested
battery to explode. or causes skin irritations.
WARNING! WARNING!
There is always a risk of sustaining burns when The batteries contain highly corrosive sulphuric
an engine is hot. Particularly hot parts are ex- acid. Take care to protect your eyes, skin and
haust manifolds, turbochargers, oil sumps, hot clothes when charging or handling batteries.
coolant and oil in pipes and hoses. Wear protective gloves and goggles.
If sulphuric acid comes in contact with the skin:
Wash with soap and plenty of water. If it gets in
your eyes: Rinse immediately with plenty of wa-
Lifting the engine ter and seek medical attention.
Always use the engine lifting eyes. Always
check that lifting accessories are in good condi-
tion and are designed to lift the weight. Environment
Optional equipment on the engine can change
the centre of gravity. This means that it may be Always hand in used batteries to an authorised
necessary to use additional lifting devices to bal- waste disposal contractor.
ance the engine correctly and lift it safely.
WARNING!
Electrical system
Never work underneath a suspended engine! The engine must be switched off and the power
disconnected using the master switch or battery
master switch before working on the electrical
system. External power supplies to extra equip-
ment on the engine must also be disconnected.
IMPORTANT!
IMPORTANT! WARNING!
When carrying out welding work on and near the Never open the coolant filler cap when the en-
engine, disconnect the battery and alternator gine is hot. Hot coolant and steam may spray out
leads. Pull out the multi-pin connector for the en- and cause burns.
gine control unit as well.
If the cap has to be opened do it slowly and care-
Connect the welding clamp close to the compo- fully to release the pressure before removing the
nent to be welded. The welding clamp must not cap. Wear gloves as the coolant is still very hot.
be connected to the engine, or so that the current
can cross a bearing.
When welding is finished: Environment
1. Connect the alternator and control unit ca-
bles first. Always hand in used coolant to an authorised
waste disposal contractor.
2. Then connect the batteries.
Fuel system
Lubrication system
WARNING!
WARNING!
Always wear protective goggles when testing in-
Hot oil can cause burns and skin irritation. Wear jectors. Fuel escaping at high pressure can pene-
protective gloves and goggles when changing trate tissues and cause serious injury.
hot oil.
Scania recommends that Scania spare parts are
Make sure that there is no pressure in the lubri- used for the fuel and electrical systems. Scania
cation system before starting work on it. spare parts are designed to minimise the risk of
The oil filler cap must always be in place when fire and explosion.
starting and running the engine to prevent oil be-
ing ejected.
Environment
IMPORTANT!
IMPORTANT!
Warranty period
Only applicable to engines used in the U.S.A. This warranty shall apply for one of the follow-
ing periods, whichever occurs first:
• 3,000 hours of operation as determined by a
Table of Contents device to measure hours of use, or
General warranty provisions 12 • Five years
Warranty period 12 Each engine is equipped with a device to meas-
Parts covered by the Warranty 13 ure hours of use. If that device fails to account for
General warranty limitations 14 hours of use due to defects in materials or work-
manship, the engine shall be warranted for a pe-
Specific warranty exclusions 15 riod of five years. The warranty period shall
Customer support 15 begin on the date the engine is delivered to the
first ultimate purchaser who, in good faith, pur-
chases the engine for purposes other than immi-
nent resale.
Emission control system war-
ranty statement
The Warranty on emission-related
General warranty provisions parts shall be interpreted as follows:
The emission control systems of your new Scan- 1. Any warranted part which is not scheduled
ia Engines (“Scania”) industrial diesel engine for replacement as required maintenance in
were designed, built and tested using genuine Scania's written instructions for maintenance
parts, and were certified as being in conformity and use of the engine by owner shall be war-
with federal emission control regulations. Scania ranted for the warranty period defined above.
warrants to the original owner, and to each sub- If any such part fails during the period of
sequent owner, of a new Scania industrial diesel warranty coverage, it shall be repaired or re-
engine (“You”) that the engine: placed by the engine manufacturer according
to Subsection (4) below. Any such part re-
1. Was designed, built and equipped so as to paired or replaced under the Warranty shall
conform at the time of sale with all applica- be warranted for the remaining warranty pe-
ble regulations under Section 213 of the riod.
Clean Air Act, 42 U.S.C. § 7547, for their
full useful life and designed, built and 2. Any warranted part which is scheduled only
equipped so as to conform with all applicable for regular inspection in Scania's written in-
regulations adopted by the California Air Re- structions for maintenance and use of the en-
sources Board pursuant to its authority under gine by owner shall be warranted for the
Chapters 1 and 2, Part 5, Division 26 of the warranty period defined above. A statement
California Health and Safety Code, and; in such written instructions to the effect of
“repair or replace as necessary” shall not re-
2. Is free from defects in material and work- duce the period of warranty coverage. Any
manship which would cause such engine to such part repaired or replaced under warran-
fail to conform to applicable regulations for ty shall be warranted for the remaining war-
its warranty period or otherwise cause the ranty period.
failure of a warranted part to be identical in
all material respects to the part as described
3. Any warranted part which is scheduled for shall not be liable under this article to war-
replacement as required maintenance in Sca- rant failures of warranted parts caused by the
nia's written instructions for maintenance use of a non-exempted add-on or modified
and use of the engine by owner shall be war- part.
ranted for the period of time prior to the first 11. The Executive Officer of the California Air
scheduled replacement point for that part. If Resources Board may request, and in such
the part fails prior to the first scheduled re- case, the engine manufacturer shall provide,
placement, the part shall be repaired or re- any documents which describe that manufac-
placed by the engine manufacturer according turer's warranty procedures or policies.
to Subsection (4) below. Any such part re-
paired or replaced under warranty shall be
warranted for the remainder of the period
prior to the first scheduled replacement point
for the part. Parts covered by the Warranty
4. Repair or replacement of any warranted part The following is a list of parts considered to be
under the warranty provisions of this article part of the Emission Control Systems covered by
shall be performed at no charge to the owner the Emission Warranty for Scania industrial en-
at a warranty station. gines which were built to conform to federal and
California emission control regulations:
5. Notwithstanding the provisions of Subsec-
tion (4) above, warranty services or repairs 1. Fuel injection system.
shall be provided at all manufacturer distri- 2. Air induction system.
bution centers that are franchised to serve the
subject engines. 3. Exhaust manifold system.
6. The owner shall not be charged for diagnos- 4. Smoke puff limiter (included in ECU).
tic labor that leadsto the determination that a 5. Oil filler cap.
warranted part is in fact defective, provided 6. EGR system (when applicable):
that such diagnostic work is performed at a
warranty station. a) Cooler.
b) EGR valve.
7. The engine manufacturer shall be liable for
damages to other engine components proxi- 7. Exhaust brake (when applicable).
mately caused by a failure under warranty of 8. NOx sensors:
any warranted part. a) NOx sensor, engine out.
8. Throughout the engine's warranty period de- b) NOx sensor, tail pipe.
fined above, the engine manufacturer shall 9. DOC (when applicable).
maintain a supply of warranted parts suffi-
cient to meet the expected demand for such 10. SCR system:
parts. a) DEF tank.
9. Any replacement part, as defined in Section b) DEF tank level, temperature and quality
1900(b), Title 13 of the California Code of sensors.
Regulations, may be used in the performance c) DEF hose.
of any maintenance or repairs and must be d) DEF injector.
provided without charge to the owner. It is e) DEF injector pressure and temperature
not necessary for replacement parts to be the sensors.
same brand or by the same manufacturer as f) Evaporator.
the original part sold with the engine. Such g) SCR catalyst inlet temperature sensor.
use shall not reduce the warranty obligations h) SCR catalyst including the ammonia-slip
of the engine manufacturer. catalyst.
i) SCR control unit (EEC3).
10. Add-on or modified parts, as defined in Sec-
tion 1900(b), Title 13 of the California Code
of Regulations, that are not exempted by the
California Air Resources Board may not be
used. The use of any non-exempted add-on
or modified parts shall be grounds for disal-
lowing a warranty claim made in accordance
with this article. The engine manufacturer
11. Miscellaneous items used in the above sys- Receipts covering the performance of regular
tem: maintenance should be retained in the event
a) Electronic control unit (ECU), sensors, questions arise concerning maintenance. The re-
wiring harnesses. ceipts should be transferred to each subsequent
b) Hoses, belts, connectors, assemblies, owner of the engine with the emission warranted
clamps, fittings tubing, sealing gaskets or engine. Scania cannot, however, deny warranty
devices and mounting hardware. solely for the lack of receipts or for your failure
c) Pulleys, belts and idlers. to ensure the performance of all scheduled main-
d) Emission control information label. tenance.
The Warranty covers the cost of diagnosis, repair
IMPORTANT! and replacement parts and services of warranted
components and systems performed by an au-
This list does not include all expendable mainte- thorized Scania distributor or dealer using genu-
nance parts. ine Scania parts. You may elect to have
maintenance, replacement or repair of these
• Expendable emission related parts requiring components and systems performed by any re-
scheduled maintenance are warranted until pair establishment or individual without invali-
their first scheduled replacement point. dating the Warranty.
• Emission related parts scheduled for inspec-
tion and replacement only as necessary are The use of other than Scania replacement parts
not considered expendable and if repaired or also does not invalidate the warranty on other
replaced under warranty shall be warranted components unless such parts cause damage to
for the remaining warranty period. warranted parts. However, the cost of such ser-
vices or parts will not be covered by the Warran-
See Specific Warranty Exclusions below. ty.
You are responsible for initiating the warranty
process. The California Air Resources Board
suggests that You present your heavy-duty off-
road engine to an authorized Scania dealer as
General warranty limitations soon as a problem exists. The warranty repairs
To retain the dependability of the exhaust emis- should be completed by the dealer as expedi-
sion control originally built into your Scania in- tiously as possible.
dustrial diesel engine, it is essential that the
engine is installed according to Scania installa-
WARNING!
tion instructions and emission certificates. Your
engine is designed to operate on diesel fuel only.
Use of any other fuel may result in your engine Use of replacement parts which are not of equiv-
no longer operating in compliance with state or alent quality may impair the effectiveness of
federal emissions requirements. The use of alter- emission control systems. Accordingly, it is rec-
native fuels shall not void the warranties on any ommended that only Scania repair or replace-
engine certified to use such fuel. ment parts be used for maintenance, repair or
replacement of emission control systems.
In addition, as the engine owner, You are respon-
sible for the performance of all scheduled main- If other than Scania parts are used for mainte-
tenance listed in your owner's manual, and all nance, repair or replacement, the owner should
necessary repairs, on your new Scania industrial obtain assurance that such parts are warranted by
diesel engine. Scania may deny a warranty claim their manufacturer to be equivalent to genuine
if the engine or part has failed due to abuse, ne- Scania parts.
glect, improper maintenance or unapproved
modifications.
Manufacturer's warranty cov- If you have any questions regarding your war-
erage ranty rights and responsibilities, you should con-
tact Scania U.S.A. Inc +1-210-403-0007.
The 2016 heavy-duty off-road engines are war-
ranted for a period of five years or 3,000 hours,
whichever occurs first. If any emission-related
part on your engine is defective, the part will be
repaired or replaced by Scania CV AB.
• Do not dispose of the spent SCR catalytic • Any dust from the SCR catalytic converter
converter or its constituent parts into any wa- should be removed using a vacuum cleaner
terways, storm drains or sanitary sewers. with microfilter to minimize exposure.
• Make sure that the work surface is cleaned af-
ter completed work; Vacuum first then swab.
WARNING!
• Make sure you clean your hands after work-
ing with SCR catalytic converter to avoid in-
The SCR catalytic converter contains vanadium
gestion.
pentoxide, a chemical known to the State of Cal-
ifornia to cause cancer. • Work done on the SCR catalytic converter
may generate waste considered by the State
of California to be a hazardous waste subject
Additional considerations when working on the to Title 22, California Code of Regulations.
SCR system Before disposing of hazardous waste, review
and follow all pertinent federal and California
• Carry out work on the SCR catalytic convert- requirements.
er in all well ventilated area. Use protective
goggles and gloves if there is any risk of
splashing or spraying of reductant or coolant.
• When engine is running, the exhaust system
parts can reach such high temperatures that
there is a risk of personal injury. Make sure
that the exhaust system temperature has de-
creased to a suitable level before starting to
work.
• The SCR system is heated by water from the
engine cooling system. The cooling system
runs at overpressure and when the engine is
hot the coolant is hot. Do not open any hoses
without first stopping the coolant flow in the
hose.
• A P3 type respirator/filter mask or a type
FFP3 fine dust musk, protective goggles and
gloves should be used for any work where
there is a risk of exposure to dust from the
SCR catalytic converter.
• Use a disposable overall and dispose of it
properly after machining.
• Eating, drinking or smoking while working is
not permitted.
Made b y
Component identification
1 2 3 9 10
11
8
12
7
6 13
340 424
5 4 14
The illustration shows a normal version of a DC16 engine. The engine ordered may have different equipment.
Note:
The oil cooler is located on the top of the engine
between the cylinder banks.
The water separating prefilter for the fuel is lo-
cated between the fuel tank and engine.
1. The DC16 084A/384A may be equipped with an exhaust brake which is connected to the turbocharger.
SCR system
The illustration provides an overview of SCR
system components.
2
1
3
4 5
7
12 13 8
10
11
340 425
1. Evaporator or hydrolysis catalytic converter 8. Reductant pump and control unit
2. Pressure line for reductant 9. Coolant hose, return from tank and pump heating
3. Coolant hose for tank and pump heating 10. Exhaust gas temperature sensor
4. NOx sensor with control unit1 11. SCR catalytic converter
5. Coolant valve 12. NOx sensor with control unit
6. Reductant return line
7. Reductant tank
Reductant tank
Reductant tanks come in 5 different sizes. The
volumes indicated for each tank are filling vol-
umes.
A filler filter with magnet is fitted in the reduct-
ant tank to prevent the reductant from becoming
contaminated when topping up. It is used when
refuelling at a filling station. A filler filter with-
out a magnet is also supplied for use when man-
ually topping up reductant.
348 425
348 422
38 litres (10 US gallons) 60 litres (15.8 US gallons)
348 421
353 442
WARNING!
WARNING!
Reductant pump
When the reductant pump is new, the check
valves may need to be slackened.
IMPORTANT!
336 838
Reductant pump
WARNING!
IMPORTANT!
Running
Check instruments and warning lamps at regular
intervals.
600-750 rpm Low idling. Engine idling is controlled by the engine management system.
Low idling up to 2,100 rpm Engine operating speed range. Controlled by the engine management sys-
tem.
2,100-2,600 rpm Unsuitable operating speed, but a slightly higher engine speed than the nor-
mal maximum operating speed may occur when load is low or negative.
2,600-3,000 rpm Prohibited engine speed.
Emission control
The system provides a warning if there are faults
on the SCR system or if the level of reductant in
the reductant tank is too low. In the case of some
faults, for example if doser cooling is not work-
ing, the torque is reduced.
torque
0% Flashing rap- Torque is reduced to Symbol for low reductant level
idly 0% (low idling)
within 2-10 minutes
1. Applies only to engines that are certified according to Tier
4.
319 563
torque
After 4 hours Flashing rap- Torque is reduced to
idly 0% (low idling) Symbol for fault in SCR system
within 2-10 minutes
1. Applies only to engines that are certified according to Tier
4.
IMPORTANT!
Note:
The torque reduction applies only to engines that
are certified according to Tier 4.
Depending on the engine configuration, the fol- The following function is standard as alarm for
lowing alarm functions may also be available: incorrect oil pressure:
IMPORTANT!
WARNING!
IMPORTANT!
Maintenance
IMPORTANT!
The maintenance programme covers a number of
points that are divided into the following sec- On delivery a Scania engine is optimised for its
tions: application. However, regular maintenance is
necessary to:
• Lubrication system
• Cooling system • prevent unplanned stops
• Air cleaner • extend the service life of the engine
• Fuel system • maximise the long-term emission perfor-
mance of the engine
• Miscellaneous
• give the best possible operating economy.
WARNING!
XL
L L
M M M
S S S S S S
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
313 153
IMPORTANT!
WARNING!
Environment
314 835
Maintenance intervals
Lubrication system
Oil grade
Scania LDF stands for the Scania Long Drain
Field test standard. Approved Scania LDF oils
have been carefully selected after extensive test-
ing. The approval is only granted to the highest
quality engine oils available on the market.
Recommended oil
Scania Oil LDF
Scania Oil LDF-2
Scania Oil LDF-3
Scania Oil E7
Oil analysis
To be able to extend the oil change intervals us-
ing an oil analysis, Scania LDF-2 and LDF-3 oils
must be used.
Oil companies can offer analysis of the engine
oil.
The following conditions must remain fulfilled
when the oil is changed.
• Viscosity at 100°C (212°F): max. ±20% of
original value of the fresh oil.
• TBN (in accordance with ASTM D4739): >
3.5
• TBN (in accordance with ASTM D4739): >
TAN (in accordance with ASTM D664)
• Soot (DIN 51452): < 3%
WARNING!
345 618
lubrication system before starting work on it.
The oil filler cap must always be in place when Min. 40 litres (10.5 US gallons).
starting and running the engine to prevent oil be-
ing ejected. Max. 48 litres (12.6 US gallons).
Environment
Note:
Change oil more often if the engine is subjected
to particularly demanding operation, such as a
dusty environment, or if deposits in the centrifu-
346 279
gal oil cleaner are thicker than 28 mm (1.1 in).
Min. 29 litres (7.6 US gallons).
1. Unscrew the oil plug and drain the oil when Max. 37 litres (9.7 US gallons).
the engine is hot. In certain engines the oil is
pumped out by means of a bilge pump.
When draining with the valve, the oil should
be hot. Alternatively, use a pump. This so
that draining occurs more quickly.
2. Clean the magnet on the oil plug.
3. Refit the oil plug. 25°
4. Top up with oil.
25°
5. Check the level on the oil dipstick.
30° 30°
Maximum angles of inclination during opera-
tion
25°
30° 30°
lustration.
336 492
Filling label in the cylinder block.
353 114
Filling label in the rocker cover.
Parts
340 130
When cleaning the centrifugal oil cleaner there
will be some dirt deposits in the rotor cover. If
this is the case, this indicates that the rotor is
working. If it is clean and not working, the cause
must be established immediately.
If the dirt deposit exceeds 28 mm at the recom-
mended intervals, the rotor cover should be
cleaned more often.
WARNING!
133 315
protect the bearing.
Note:
Take care not to damage the rotor shaft.
IMPORTANT!
133 316
5. Remove the rotor cover by holding the rotor
in both hands and tapping the rotor nut
against the table. Never strike the rotor di-
rectly as this may damage its bearings.
133 317
127 878
7. Remove the paper insert and scrape away
any remaining dirt deposits inside the rotor
cover. If the deposits are thicker than 28 mm,
the centrifugal oil cleaner must be cleaned
more often.
333 044
2 3 4
337 178
127 881
Note:
Take care not to damage the rotor shaft.
313 612
IMPORTANT!
Note:
A torque wrench together with a ratchet head is
suitable for use during maintenance of the cen-
trifugal oil cleaner.
313 611
Operational testing
Operational testing need only be carried out if it
is suspected that the centrifugal oil cleaner is not
working properly. For example, if there is an ab-
normally small amount of deposit in the centrif-
ugal oil cleaner in relation to the distance driven.
The rotor rotates very fast and should continue to
turn when the engine has stopped.
1. Run the engine until it is warm.
2. Turn off the engine and listen for the sound
from the rotor. Use your hand to feel if the
333 039
118 268
IMPORTANT!
IMPORTANT!
312 505
-50
The coolant should be changed when the cooling
system is cleaned: every 6,000 hours or at least °C B A
every 5 years. Refer to Changing coolant.
Curve A: Ice formation starts (ice slush)
Curve B: Damage by freezing occurs
Area 1: Safe area
Area 2: Malfunctions may occur (ice
slush)
Area 3: Risk of damage by freezing
WARNING!
305 523
If the cap has to be opened do it slowly and care-
fully to release the pressure before removing the
138008
cap. Wear gloves as the coolant is still very hot.
Note:
Use only pure fresh water that is free from parti-
1. Open the expansion tank cap and check the cles, sludge and other impurities.
coolant level.
– The right coolant level on a cold engine is
even with the lower edge of the filler neck. 1. Pour a small amount of coolant into a con-
– The right coolant level on a hot engine is tainer and check that the coolant is pure and
approximately 25 mm (1 in) over the low- clear.
er edge of the filler neck. 2. Change the coolant if it is contaminated or
2. Top up with coolant as necessary. cloudy.
3. Measure the antifreeze and corrosion inhibi-
tor content with a refractometer.
IMPORTANT!
Do not top up large quantities of coolant through The following rules apply to ethylene glycol-
the expansion tank. Top up in accordance with based coolant:
the instructions in the section headed Changing
coolant instead. • The antifreeze and corrosion inhibitor content
must be minimum 35 percent by volume for
corrosion protection to be sufficient.
• An antifreeze and corrosion inhibitor content
IMPORTANT!
greater than 55 percent by volume impairs the
ability to protect against frost.
Never fill a large amount of cold coolant in a hot
engine. There is great risk of cracks forming in • If ice forms in the coolant, there are disrup-
the cylinder block and cylinder heads. tions initially, but there is no immediate risk
of damage. The engine should not be subject-
ed to heavy loads when ice starts to form.
IMPORTANT!
Scania concentrate
Designation Contents Part No. Volume Volume
litre US gallons
Coolant Antifreeze and corrosion inhibitor (concentrate) 1 894 323 5 1.3
Coolant Antifreeze and corrosion inhibitor (concentrate) 1 894 324 20 5.3
Coolant Antifreeze and corrosion inhibitor (concentrate) 1 894 325 210 55
Coolant Antifreeze and corrosion inhibitor (concentrate) 1 894 326 1,000 264
333 980
Draining coolant
1. Remove the expansion tank cap.
2. Drain the coolant at the following two IMPORTANT!
points:
Lowest point of the cylinder block. When it is necessary to fill a large quantity of
The lowest point of the cooling system. coolant, it must be pumped in from underneath.
This is to ensure that air does not get into the
3. Close the drain taps.
cooling system, which can cause the coolant
pump to overheat.
Environment
1. Use a Scania coolant trolley, or other suitable
Avoid spillage and use a suitable container. Used equipment, to fill with coolant through the
coolant must be disposed of as specified in na- drain valve on the cylinder block. This facil-
tional and international law. itates the venting of the engine.
2. Start the engine when the cooling system has
been filled. Allow the engine to run for a
while. Then check the coolant level and top
up with coolant as necessary.
3. Air pockets may still be left in the cooling
system, which will disappear after the engine
has been operated for a period of time. It
may, therefore, need some topping up to start
with.
WARNING!
IMPORTANT!
Note:
Clean the cooling system more often than speci-
fied in the maintenance interval if necessary.
7. Drain the water from the cooling system. 6. Fill the cooling system with clean, hot water
and run the engine for about 20-30 minutes.
8. Refit the thermostats.
7. Drain the water from the cooling system.
9. Fill the cooling system with new coolant fol-
lowing the specification under Coolants ear- 8. Refit the thermostats.
lier in the document. 9. Fill the system with new coolant following
the specification under Coolants earlier in
the document.
Environment Environment
Avoid spillage and use a suitable container. Used Avoid spillage and use a suitable container. Used
coolant must be disposed of as specified in na- coolant must be disposed of as specified in na-
tional and international law. tional and international law.
Air cleaner
326 671
Note:
Renew the filter element earlier than the mainte-
nance interval if the indicator shows red. A B
WARNING!
336 100
Never start the engine without the air filter as this
could cause injury and severe engine damage. A Vacuum indicator.
B Filter element.
1. Remove the cover from the air cleaner.
2. Renew the filter element.
3. Carry out a check by inserting an inspection
lamp into the element and checking from the
outside that there are no holes or cracks in the
filter paper.
4. Assemble the air cleaner.
5. Reset the vacuum indicator by pressing the
button.
IMPORTANT!
Fuel system
IMPORTANT!
Note:
The fuel system must be bled if the tank has been
run dry. Refer to the Bleeding the fuel system
section.
Removal
Designation Illustration
Hexagon socket, 1/2” drive, 36 mm
118 268
Bleeding tool
337 296
Environment
IMPORTANT!
IMPORTANT!
IMPORTANT!
329 247
Wait a minimum of 2 minutes to allow as much
of the fuel as possible to drain out of the filter
housing.
A
329 248
IMPORTANT!
329 249
6. Unscrew the pressure filter cover (B) and lift
it up slowly with the filter element. B
7. Fuel from the pressure filter housing (B) will
flow into the water separating suction filter
housing (A). Leave the bleeding tool in the
water separating suction filter housing (A)
until it is completely drained of fuel.
A
329 250
IMPORTANT!
329 251
Fitting
Designation Illustration
Hexagon socket, 1/2” drive, 36 mm
118 268
1. Unpack the new filter elements and the sup-
plied O-rings.
IMPORTANT!
IMPORTANT!
337 296
1. Open the bleed nipple at the high pressure
pump and connect a clear plastic hose from
the bleeding tool.
329 252
Miscellaneous
Checking the drive belt
IMPORTANT!
314 906
Check the drive belt for cracks.
112 931
The drive belt is starting to become worn, but can be
refitted.
112 932
IMPORTANT! The belt is worn down to the cord. The drive belt
must be renewed.
If serious leakage occurs, contact your nearest
workshop.
142 238
WARNING!
Note:
Checking and adjusting valve clearances should
also be done one more time after the first 500
hours of operation. Then the normal interval will
follow (every 2,000 hours).
Note:
Valve transition occurs when the cylinder
switches from exhaust stroke to intake stroke.
The exhaust valve is closing while the intake
valve is opening.
310 343
Openings for taking readings on the flywheel hous-
ing.
1 2 3 4
314 908
5 6 7 8
Cylinder location.
IMPORTANT!
Reading in the lower Valve transition on Adjust intake valve on Adjust exhaust valve on
window cylinder cylinder cylinder
TDC down (0°) 6 7 and 8 4 and 5
TDC up (180°) 7 1 and 5 2 and 6
TDC down (360°) 1 2 and 4 3 and 7
TDC up (540°) 4 3 and 6 1 and 8
7 3 7 3
8 4 8 4
5 1 5 1
C D
6 2 6 2
7 3 7 3
8 4 8 4
121 052
118 268
1. Remove the cover on the rear of the reduct-
ant tank.
316 163
2. Place a suitable container underneath.
3. Unscrew the filter cover. Use the socket.
4. Remove the filter cover and O-ring.
326 565
336 879
A Pump.
B Filter.
C Frost protection device.
D O-ring.
E Cover.
350 114
Cleaning the reductant tank
ventilation filter
Make sure that the ventilation filter (2) is clean.
If it is dirty: Clean the ventilation filter with
clean water and refit it. 2
352 009
Responsibility
IMPORTANT!
Preservative oil 10. Drain the preservative oil from the engine.
Fill with new engine oil immediately or
Suitable preservative oils are supplied by most when the engine is to be reused.
oil companies. Example: Dinitrol 40 or equiva-
11. Drain the coolant if the engine is not to be
lent.
stored with coolant in the system. Plug and
tape all coolant connections if the engine is
to be stored without a cooling system.
Preparations for storage 12. Air cleaner: Clean or renew the filter ele-
ment.
Environment 13. Cover air intakes and exhaust pipes.
14. Alternator and starter motor: Spray with wa-
Use a container to avoid spillage when draining ter-repellent anti-corrosive oil, CRC 226,
the oil, coolant and reductant. Dispose of used LPS1 or the equivalent.
fluids through an authorised waste disposal con- 15. Spray the outside of bright engine parts, first
tractor. with penetrating preservative oil such as
Dinitrol 25B and then with Dinitrol 112 or
1. Drain and flush the cooling system. Top up
the equivalent.
with preservative coolant. Clearly mark the engine with the storage prepa-
2. Warm up the engine on normal fuel. Stop the ration date, and state that the engine must not be
engine and drain the oil. started or cranked.
3. Renew the fuel filter. If the engine is to stand idle for more than a year:
4. Fill the engine with preservative oil up to the
minimum level on the oil dipstick. 16. Drain the reductant from the reductant tank.
5. Mix preservative fuel in a can. Detach the
fuel pipe at the feed pump suction line and
connect a hose from the can.
6. Detach the fuel pipe at the overflow valve
and connect a return hose to the can.
7. Start the engine and run it at about 1,000 rpm
for 20-25 minutes.
8. Stop the engine, remove the hoses and con-
nect the normal fuel pipes.
9. Remove the rocker covers and lubricate the
valve mechanisms with plenty of preserva-
tive oil. Refit the rocker covers.
Note:
Do not remove the injectors.
Batteries Storage
Remove the batteries and trickle charge them at After the preparations, the engine should be
the battery charging station. This does not apply stored in a dry and warm place (room tempera-
to batteries specified as maintenance-free by the ture).
manufacturer.
The same applies to short-term storage, even if
the engine has not been prepared for storage as When the engine is to be taken into
above. operation again
1. Remove plugs and tape from coolant connec-
tions, air intakes and exhaust pipes.
WARNING!
2. Fill the cooling system with coolant. For
more information refer to Maintenance.
Wear gloves and protective goggles when charg-
ing and handling batteries. The batteries contain 3. Check the oil level in the engine or top up
a highly corrosive acid. with fresh engine oil.
4. Lubricate the valve mechanisms and their
pushrods and valve tappets as well as the in-
jector mechanisms with plenty of oil.
5. Drain the preservative fuel from the fuel
manifold and fuel filter.
6. Connect and bleed the fuel system. For more
information refer to Maintenance.
7. Wash off any preservative oil on the outside
using white spirit.
Technical data
General data
Lubrication system
Injection system
Cooling system
Intake system
Permissible pressure drop in the intake system with cleaned or new fil- 30
ter (mbar)
Permissible pressure drop in the intake system with blocked (dirty) fil- 65
ter (mbar)
Electrical system
Type 1-pin, 24 V, DC
Starter motor, standard equipment 1-pin, 24 V, 7.0 kW
Alternator, standard equipment 1-pin, 28 V, 100 A
Scania Assistance
Wherever you are, you can always get assistance from the Scania service organisation, Scania Assistance,
all day, every day of the year.