Cold Water: Rubin Meistream, Meistream Plus

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

RUBIN MeiStream,

MeiStream Plus
Cold water

Applications
RUBIN MeiStream and MeiStream Plus water meters operate according to the turbine blade flow measuring principle and are
designed for high-volume water measurement. The complete modular and housing system covers all areas of water supply
management. Meters can be retrofitted with pulse and data interfaces for mobile or stationary remote measurement.

Features Your benefits


• Wide measuring range • Your benefits
• Measuring units can be replaced • Measuring both small and large volumes with one
• Universal installation (MeiStream) flowmeter
• High overload capacity • MeiStream Plus is ideal for monitoring piping systems
• Can be retrofitted with non-reactive modules for and detecting pipe leaks
remote readings • One version with the advantages of both Woltman WP
• With MID approval and WS
• No straight inlet necessary
VD 1-300 e 10.2009
Range
• Turbine meters with dry-type registers, IP 68
• SVGW certification
• The meter can be installed in horizontal, vertical or inclined positions. The meter
head must, however, face upwards or to the side. The MeiStream Plus is for horizon-
tal installation only.
• Requires no inlet path
• Powder-coated grey cast iron housing with flange connections acc. to EN 1092-1
• Maximum temperature 50 °C
• Nominal pressure PN 16
• Replaceable measuring unit
• For updating with non-reactive HRI modules or optoelectronic pulsers

RUBIN MeiStream

Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80
inch 1 1/2 2 2 2 1/2 2 1/2 3 3
Art. No. 94524 94525 94585 94526 94586 94527 94587

Overload Q4 m3/h 60 90 90 120 120 200 200


Nominal flowrate Q3 m3/h 40 50 50 70 70 120 120
Transitional flowrate horizonal Q2 m3/h 0.32 0.4 0.4 0.63 0.63 0.51 0.51
Transitional flowrate vertical Q2 m3/h 0.4 0.51 0.51 0.81 0.81 0.8 0.8
Minimum flowrate horizontal Q1 m3/h 0.2 0.15 0.15 0.2 0.2 0.2 0.2
Minimum flowrate vertical Q1 m3/h 0.25 0.28 0.28 0.4 0.4 0.5 0.5
Starting flow at approx. m3/h 0.05 0.05 0.05 0.07 0.07 0.1 0.1
Max. pressure loss at Q3 bar 0.08 0.18 0.18 0.37 0.37 0.16 0.16
Smallest readable volume litre 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Recording capacity mio. m3 1 1 1 1 1 1 1
Data for MID-homologation
Nominal flowrate Q3 m3/h 25 40 40 63 63 100 100
Measuring range horizontal R 125 160 160 160 160 315 315
Measuring range vertical R 100 125 125 125 125 200 200
Measuring range as shown on delivery R 63 100 100 100 100 100 100
Weight kg 7.5 7.8 9.6 10.1 12.0 14.2 16.3
Overall length
L 220 200 270 200 300 225 300
H 120 120 120 120 120 150 150
g

h 69 73 73 85 85 95 95
g 200 200 200 200 200 270 270
H
h

1) Flanges with 4 holes

2
Nominal diameter DN mm 100 100 125 150 150
inch 4 4 5 6 6
Art. No. 94528 94588 94529 94530 94589
Overload Q4 m3/h 300 300 350 600 600
Nominal flowrate Q3 m3/h 230 230 250 450 450
Transitional flowrate horizonal Q2 m3/h 0.81 0.81 1.02 1.6 1.6
Transitional flowrate vertical Q2 m3/h 1.28 1.28 1.6 3.2 3.2
Minimum flowrate horizontal Q1 m3/h 0.3 0.3 0.5 0.8 0.8
Minimum flowrate vertical Q1 m3/h 0.5 0.5 1 1.6 1.6
Starting flow at approx. m3/h 0.11 0.11 0.15 0.3 0.3
Max. pressure loss at Q3 bar 0.34 0.34 0.2 0.32 0.32
Smallest readable volume litre 0.5 0.5 0.5 5 5
Recording capacity mio. m3 1 1 1 10 10
Data for MID-homologation
Nominal flowrate Q3 m3/h 160 160 160 400 400
Measuring range horizontal R 315 315 250 400 400
Measuring range vertical R 200 200 160 200 200
Measuring range as shown on delivery R 100 100 100 100 100
Weight kg 18.2 20.2 20.7 35.9 44.2
Overall length
L 250 360 250 300 500
H 150 150 160 177 177
h 105 105 118 135 135
g

g 270 270 280 356 356


H
h

Available on request:
- Nominal pressure PN 40
- Non-ferrous metal version
- Version for use in explosion-proof areas
- Flanged version e.g. ANSI, JIS

3
RUBIN MeiStream Plus

Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80
inch 1 1/2 2 2 2 1/2 2 1/2 3 3
Art. No. 94534 94535 94590 94536 94591 94537 94592

Overload Q4 m3/h 50 55 55 60 60 120 120


Nominal flowrate Q3 m3/h 30 35 35 40 40 63 63
Transitional flowrate horizonal Q2 m3/h 0.13 0.13 013 0.16 0.16 0.25 0.25
Minimum flowrate horizontal Q1 m3/h 0.08 0.07 0.07 0.1 0.1 0.13 0.13
Starting flow at approx. m3/h 0.03 0.03 0.03 0.04 0.04 0.04 0.04
Max. pressure loss at Q3 bar 0.09 0.08 0.08 0.17 0.17 0.07 0.07

Smallest readable volume litre 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Recording capacity mio. m3 1 1 1 1 1 1 1
Data for MID-homologation
Nominal flowrate Q3 m3/h 25 25 25 40 40 63 63
Measuring range horizontal R 315 315 315 400 400 400 400
Measuring range as shown on delivery R 315 315 315 315 315 315 315
Weight kg 7.5 7.8 9.6 10.1 12.0 14.2 16.3
Overall length
L 220 200 270 200 300 225 300
g

H 120 120 120 120 120 150 150


h 69 73 73 85 85 95 95
H

g 200 200 200 200 200 270 270


h

1) Flanges with 4 holes

Nominal diameter DN mm 100 100 150 150


inch 4 4 6 6
Art. No. 94538 94593 94539 94594
Overload Q4 m3/h 160 160 400 400
Nominal flowrate Q3 m3/h 100 100 250 250
Transitional flowrate horizonal Q2 m3/h 0.4 0.4 0.63 0.63
Minimum flowrate horizontal Q1 m3/h 0.2 0.2 0.35 0.35
Starting flow at approx. m3/h 0.07 0.07 0.12 0.12
Max. pressure loss at Q3 bar 0.16 0.16 0.14 0.14
Smallest readable volume litre 0.5 0.5 5 5
Recording capacity mio. m3 1 1 10 10
Data for MID-homologation
Nominal flowrate Q3 m3/h 100 100 250 250
Measuring range horizontal R 400 400 630 630
Measuring range as shown on delivery R 315 315 315 315
Weight kg 18.2 20.2 35.9 44.2
Overall length
L 250 360 300 500
H 150 150 177 177
h 105 105 135 135
g

g 270 270 356 356


H
h

Available on request:
- Version for use in explosion-proof areas

4
Roller counters
DN 40...125 DN 150

x 0,1 x1
9 0 1 9 0 1

m3
8
7
6 5 4
2
3 x10m3 8
7
6 5 4
2
3

x 0,01 x 0,1
9 0 1 9 0 1
x 0,001 8 2 x 0,01 8 2
9 0 1 7 3 7 3
O

9 0 1

O
6 5 4 6 5 4
OPT

OPT
8 2 8 2
7 3 7 3
6 5 4 6 5 4

Pulsers

The Meistream / Meistream Plus large capacity water meters are designed to be used with non-reactive HR modules and optoelectronic
pulsers. Add-ons can also be retrofitted without affecting the metrological data.

HRI modules
• 2 programmable pulse outputs and M-Bus data interface to IEC870-5/
EN1434-3
• Non-reactive inductive tap with external manipulation detection
• Lifetime of battery approx. 12 years, external power supply via M-Bus
approx. 15 years
• Cable length 3 m
• Ambient temperature -10 - 60 °C, IP 68
• Forward/reverse flow recognition
• Pulse value, length and type selectable with MiniCom software

M-Bus output, data transmission:


- Meter reading
- Fabrication number
- Meter number with secondary address
- Monthly meter reading on any day selected
- Meter reading with current and previous year’s billing date selected
- Minimum and maximum flowrate with time and date
- Reverse flow volume with time and date
- Pipe breakage and leak detection with selectable limit value
- Detection of any attempt at external manipulation

Pulse outputs:
- Programmable as:
Opto-OD (NAMUR to EN 60947-5-6), pulse width 6 ms or
Reed-RD compatible, pulse width 32, 128 or 500 ms, max. 48 VDC, max. 0.2 A, max. 4 Watt

5
The following pulse modes can be set:

Pulse mode B1 B2 B3 B4 B5 B6
Pulse output
I1 (white) Balanced Forward Forwards and Balanced NAMUR pulses NAMUR pulses with
pulses 1) pulses reverse pulses pulses 1) with forward/ blackflow suppres-
reverse sion (OD-AM)
recognition
I2 (yellow) On = Alarm 2) Reverse On = Forwards Off = Alarm 2) Not used Not used
pulses flow
1) Reverse pulses are compensated by suppressing the identical number of forward pulses.
2) Can be assigned for pipe breakage, leakage detection, external interference and cable breakage.

Type designation Version Art. No.


HRI-Mei/B4/D100/T500 DN 40...125: Open collector, 100 litres /pulse, pulse length 500 ms 80508
HRI-Mei/B4/D1000/T500 DN 150: Open collector, 1000 litres/pulse, pulse length 500 ms 80509
HRI-Mei/B5/D10/T6 DN 40...125: NAMUR (EN 60947-5-6), 10 litres/pulse, pulse length 6 ms 80510
HRI-Mei/B5/D100/T6 DN 150: NAMUR (EN 60947-5-6), 100 litres/pulse, pulse length 6 ms 80511
HRI-Mei-CDL/D10/T6 DN 40...125: Forward/reverse pulse with plug for CDL data logger, 80512
10 litres/pulse, pulse length 6 ms
HRI-Mei-CDL/D100/T6 DN 150: Forward/reverse pulse with plug for CDL data logger, 100 litres/pulse, 80513
pulse length 6 ms

MiniCom software is required for changing set parameters.

The HRI-Mei pulser is available with the following parameters on request:

Version DN 40...125 DN 150


Open collector / NAMUR 0.01, 0.05, 0.1 or 1 m3/pulse 0.1, 0.5, 1 or 10 m3/pulse
pulse length 32, 128 or 500 ms pulse length 32, 128 or 500 ms
pulse length NAMUR 6 ms pulse length NAMUR 6 ms

6
Optoelectronic pulsers

• IR reflex light barriers to EN 50227 as a plug-in version


• Non-reactive optical tap
• Cable length 3 m
• Ambient temperature -10 - 70 °C, IP 68

Technical data:
- Power supply 8.2 VDC
- Switch current (actuated) ≤1.2 mA
- Quiescent current (non-contact) ≥2.1 mA
- Forwards and reverse flow detection is built in by means of an additional current threshold at 1.5 mA. With forward flow, the rising
pulse edge thus has an additional current threshold of 1.5 mA. With reverse flow, the current threshold lies on the falling edge of the
pulse.
Forward flow: Reverse flow:

- Pulse length is dependent on the flowrate and at meter standstill a continuous pulse is possible.

Type designation Version Art. No.


OD 01 Optoelectronic pulser, smaller pulse value 93750
OD 03 Optoelectronic pulser, larger pulse value 93752

Standard pulse values and frequencies

Nominal diameter DN mm 40 50 65 80 100 125 150


inch 1 1/2 2 2 1/2 3 4 5 6
HRI-Mei modules
Pulse value litres/pulse 100 100 100 100 100 100 1000
Pulse length ms 500 500 500 500 500 500 500
OD pulser
OD 01 litres/pulse 1 1 1 1 1 1 10
Pulse frequency at Q4 Hz 13.9 13.9 21.9 34.7 55.5 55.5 13.9
Pulse frequency at Q1 Hz 0.035 0.035 0.055 0.055 0.055 0.089 0.014
OD 03 litres/pulse 10 10 10 10 10 10 100

7
Frequency transmitters
FM-1D/K
• Frequency transmitter
• Pulse/current transformer and flowrate indicator for water meters
• The FM-1D/K is a microprocessor-controlled frequency transmitter with digital
display. It converts pulses into a flow-proportional current to indicate flowrate with the
following outputs:
- Current output
- Counting pulses
- Illuminated digital display

FM-2D/K
• Frequency transmitter
• Flowrate summation of two water meters
• The FM-2D/K is a microprocessor-controlled frequency transmitter with two pulse
outputs
• It can be used for combining signals from two pulses with a flow direction signal
• M-Bus output

Frequency transmitter FM-1D/K FM-2D/K


Art. No. 93236 92390
Input
Universal input for pulser reed contact or 1 2
NAMUR to EN 50227
Input frequency range for 0/4...20 mA 0...0.1 to 0...1000Hz 0...300 Hz, 0...150 Hz with
flow direction recognition
Maximum cable length. approx. 6 km approx. 6 km
Outputs
Current output 0...20 mA or 4...20 mA, 1 2
max. load 1 kOhm
Relay, NO contact, max. 48 VAC/DC 1 A, 1 2
potential-free
Optocoupler output, max. 30 V, 30 mA - 2
M-Bus Output - 1
Ambient temperature 0...70 °C 0...70 °C
Protection type IP 40 IP 40
Supply voltage 230 VAC or 24 VAC / VDC 230 VAC or 24 VAC / VDC
Montage 35 mm standard rail 35 mm standard rail
Dimensions 100 x 73 x 114 (B x H x D) mm 100 x 73 x 114 (B x H x D) mm

8
FM-1D/K
Alternative
24 V DC
or Flowrate indicator
Power supply
230 V AC 24 V AC

Pulse counter
Grounding
1234567 8

24 V

L N PE 24 VAC/D C + - 12345678

FM-1D/K

+ - select

+ Sensor - U+
RUBIN with OD 01

FM-2D/K

Power supply Forwards Reverse Power supply


flow 230 V/AC Power supply
230 V/AC Power supply flow
Flowrate or 115 V/AC 24 VAC/DC Forwards Pulse counter
or 115 V/AC 24 VAC/DC
indicator flow
Grounding
Grounding
Direction
Pulse

Earth

Elektronischer
RUBIN with OD 01 RUBIN with OD 01 Saldierzähler

RUBIN meitwin with OD 01


Submeter with reed contact

9
Installation notes
Nominal sizes: pipes, meters and pipe reducers
The choice of the nominal meter size should not automatically be based on the nominal size of the pipe. The decisive factor is the hig-
hest flowrate that occurs continuously in the pipe - this determines the nominal flowrate Qn of the meter.

< 8° < 8°

AM066243a

Mounting height
RUBIN MeiStream / MeiStream Plus meters have exchangeable velocity measuring units which can be tested and calibrated independ-
ently of the housing. For this purpose, the old units are removed upwards. When designing the installation, it is important to ensure that
there is adequate space above the meter for removal.

Installation position
Meters must not be installed upside-down as then the metrological approval requirements will not be met.

Electrical installation
Electrical cables and installation must be carried out by a specialist in accordance with legal requirements.

10
Measurement error limits
According to Directive OIML R 49
% 5

3
Error tolerances
2

-1
Typical error curve
-2

-3

-4

-5
Q1 Q2 Q3 Q4

11
Pressure loss curves
RUBIN MeiStream

DN 125
DN 100

DN 150
DN 50
DN 65
DN 40

DN 80
Pressure loss

Flow in m3/h

RUBIN MeiStream Plus


DN 100

DN 150
DN 80
DN 40
DN 50
DN 65

Modification rights reserved / Copyright © Aquametro AG