Cold Water: Rubin Meistream, Meistream Plus
Cold Water: Rubin Meistream, Meistream Plus
Cold Water: Rubin Meistream, Meistream Plus
MeiStream Plus
Cold water
Applications
RUBIN MeiStream and MeiStream Plus water meters operate according to the turbine blade flow measuring principle and are
designed for high-volume water measurement. The complete modular and housing system covers all areas of water supply
management. Meters can be retrofitted with pulse and data interfaces for mobile or stationary remote measurement.
RUBIN MeiStream
Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80
inch 1 1/2 2 2 2 1/2 2 1/2 3 3
Art. No. 94524 94525 94585 94526 94586 94527 94587
h 69 73 73 85 85 95 95
g 200 200 200 200 200 270 270
H
h
2
Nominal diameter DN mm 100 100 125 150 150
inch 4 4 5 6 6
Art. No. 94528 94588 94529 94530 94589
Overload Q4 m3/h 300 300 350 600 600
Nominal flowrate Q3 m3/h 230 230 250 450 450
Transitional flowrate horizonal Q2 m3/h 0.81 0.81 1.02 1.6 1.6
Transitional flowrate vertical Q2 m3/h 1.28 1.28 1.6 3.2 3.2
Minimum flowrate horizontal Q1 m3/h 0.3 0.3 0.5 0.8 0.8
Minimum flowrate vertical Q1 m3/h 0.5 0.5 1 1.6 1.6
Starting flow at approx. m3/h 0.11 0.11 0.15 0.3 0.3
Max. pressure loss at Q3 bar 0.34 0.34 0.2 0.32 0.32
Smallest readable volume litre 0.5 0.5 0.5 5 5
Recording capacity mio. m3 1 1 1 10 10
Data for MID-homologation
Nominal flowrate Q3 m3/h 160 160 160 400 400
Measuring range horizontal R 315 315 250 400 400
Measuring range vertical R 200 200 160 200 200
Measuring range as shown on delivery R 100 100 100 100 100
Weight kg 18.2 20.2 20.7 35.9 44.2
Overall length
L 250 360 250 300 500
H 150 150 160 177 177
h 105 105 118 135 135
g
Available on request:
- Nominal pressure PN 40
- Non-ferrous metal version
- Version for use in explosion-proof areas
- Flanged version e.g. ANSI, JIS
3
RUBIN MeiStream Plus
Nominal diameter DN mm 40 50 50 65 1) 65 1) 80 80
inch 1 1/2 2 2 2 1/2 2 1/2 3 3
Art. No. 94534 94535 94590 94536 94591 94537 94592
Smallest readable volume litre 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Recording capacity mio. m3 1 1 1 1 1 1 1
Data for MID-homologation
Nominal flowrate Q3 m3/h 25 25 25 40 40 63 63
Measuring range horizontal R 315 315 315 400 400 400 400
Measuring range as shown on delivery R 315 315 315 315 315 315 315
Weight kg 7.5 7.8 9.6 10.1 12.0 14.2 16.3
Overall length
L 220 200 270 200 300 225 300
g
Available on request:
- Version for use in explosion-proof areas
4
Roller counters
DN 40...125 DN 150
x 0,1 x1
9 0 1 9 0 1
m3
8
7
6 5 4
2
3 x10m3 8
7
6 5 4
2
3
x 0,01 x 0,1
9 0 1 9 0 1
x 0,001 8 2 x 0,01 8 2
9 0 1 7 3 7 3
O
9 0 1
O
6 5 4 6 5 4
OPT
OPT
8 2 8 2
7 3 7 3
6 5 4 6 5 4
Pulsers
The Meistream / Meistream Plus large capacity water meters are designed to be used with non-reactive HR modules and optoelectronic
pulsers. Add-ons can also be retrofitted without affecting the metrological data.
HRI modules
• 2 programmable pulse outputs and M-Bus data interface to IEC870-5/
EN1434-3
• Non-reactive inductive tap with external manipulation detection
• Lifetime of battery approx. 12 years, external power supply via M-Bus
approx. 15 years
• Cable length 3 m
• Ambient temperature -10 - 60 °C, IP 68
• Forward/reverse flow recognition
• Pulse value, length and type selectable with MiniCom software
Pulse outputs:
- Programmable as:
Opto-OD (NAMUR to EN 60947-5-6), pulse width 6 ms or
Reed-RD compatible, pulse width 32, 128 or 500 ms, max. 48 VDC, max. 0.2 A, max. 4 Watt
5
The following pulse modes can be set:
Pulse mode B1 B2 B3 B4 B5 B6
Pulse output
I1 (white) Balanced Forward Forwards and Balanced NAMUR pulses NAMUR pulses with
pulses 1) pulses reverse pulses pulses 1) with forward/ blackflow suppres-
reverse sion (OD-AM)
recognition
I2 (yellow) On = Alarm 2) Reverse On = Forwards Off = Alarm 2) Not used Not used
pulses flow
1) Reverse pulses are compensated by suppressing the identical number of forward pulses.
2) Can be assigned for pipe breakage, leakage detection, external interference and cable breakage.
6
Optoelectronic pulsers
Technical data:
- Power supply 8.2 VDC
- Switch current (actuated) ≤1.2 mA
- Quiescent current (non-contact) ≥2.1 mA
- Forwards and reverse flow detection is built in by means of an additional current threshold at 1.5 mA. With forward flow, the rising
pulse edge thus has an additional current threshold of 1.5 mA. With reverse flow, the current threshold lies on the falling edge of the
pulse.
Forward flow: Reverse flow:
- Pulse length is dependent on the flowrate and at meter standstill a continuous pulse is possible.
7
Frequency transmitters
FM-1D/K
• Frequency transmitter
• Pulse/current transformer and flowrate indicator for water meters
• The FM-1D/K is a microprocessor-controlled frequency transmitter with digital
display. It converts pulses into a flow-proportional current to indicate flowrate with the
following outputs:
- Current output
- Counting pulses
- Illuminated digital display
FM-2D/K
• Frequency transmitter
• Flowrate summation of two water meters
• The FM-2D/K is a microprocessor-controlled frequency transmitter with two pulse
outputs
• It can be used for combining signals from two pulses with a flow direction signal
• M-Bus output
8
FM-1D/K
Alternative
24 V DC
or Flowrate indicator
Power supply
230 V AC 24 V AC
Pulse counter
Grounding
1234567 8
24 V
L N PE 24 VAC/D C + - 12345678
FM-1D/K
+ - select
+ Sensor - U+
RUBIN with OD 01
FM-2D/K
Earth
Elektronischer
RUBIN with OD 01 RUBIN with OD 01 Saldierzähler
9
Installation notes
Nominal sizes: pipes, meters and pipe reducers
The choice of the nominal meter size should not automatically be based on the nominal size of the pipe. The decisive factor is the hig-
hest flowrate that occurs continuously in the pipe - this determines the nominal flowrate Qn of the meter.
< 8° < 8°
AM066243a
Mounting height
RUBIN MeiStream / MeiStream Plus meters have exchangeable velocity measuring units which can be tested and calibrated independ-
ently of the housing. For this purpose, the old units are removed upwards. When designing the installation, it is important to ensure that
there is adequate space above the meter for removal.
Installation position
Meters must not be installed upside-down as then the metrological approval requirements will not be met.
Electrical installation
Electrical cables and installation must be carried out by a specialist in accordance with legal requirements.
10
Measurement error limits
According to Directive OIML R 49
% 5
3
Error tolerances
2
-1
Typical error curve
-2
-3
-4
-5
Q1 Q2 Q3 Q4
11
Pressure loss curves
RUBIN MeiStream
DN 125
DN 100
DN 150
DN 50
DN 65
DN 40
DN 80
Pressure loss
Flow in m3/h
DN 150
DN 80
DN 40
DN 50
DN 65
Flow in m3/h
AQUAMETRO AG
Ringstrasse 75
A0 -10.2009
CH-4106 Therwil
Phone +41 61 725 11 22
Fax +41 61 725 15 95
Contact, Adress and Stamp info@aquametro.com www.aquametro.com