WESAN WP

BULK WATER METER | WOLTMAN

APPLICATION
The bulk water meter WESAN WP can be used for measuring the flow (cold
water up to 30 °C) in supply lines with high flow at low pressure loss.

FEATURES
4 Calibratable and exchangeable measuring insert
4 For horizontal and vertical installation
4 Sealed measuring insert for better accuracy
4 Hydraulic bearing relief
4 Wear-resistant plastic bearing
4 Encapsulated counter of glass/copper IP 68
4 Complete head unit with counter and sensors can be rotated by 350° for
easier reading
4 Integrated measurement outputs as standard
4 Sensors for remote readout (digital) and flow measurement (analogue) can
be retrofitted on site without affecting calibration
WESAN WP
BULK WATER METER | WOLTMAN

GENERAL
WESAN WP 222
Medium temperature range °C 0 ... 30
Temperature safety °C 0 ... 50
Ambient operating temperature °C 0 ... 55
Ambient storage temperature °C 0 ... 55
Nominal pressure PN bar 16*
Protection class IP 68

* Special versions on request

TECHNICAL DATA
Nominal diameter DN mm 50 65 80 100 125 150
Permanent flow rate Q3 m³/h 40 63 100 160 160 -
Minimum flow rate Q1 m³/h 0.63 0.63 1 1.6 1.6 -
Transitional flow rate Q2 m³/h 1.02 1.01 1.6 2.56 2.56 -
Overload flow rate Q4 m³/h 50 78.75 125 200 200 -
Nominal flow rate (DIN ISO
4064) Qn m³/h 15 25 40 60 100 150
Minimum flow rate horizontal Qmin m³/h 0.35 0.45 0.5 0.6 0.6 1.8
Minimum flow rate vertical Qmin m³/h 0.4 0.5 0.5 0.6 0.6 1.8
Transition flow rate horizontal Qt m³/h 1 1.2 0.8 1.8 2 4
Transition flow rate vertical Qt m³/h 1.8 2 0.8 1.8 2 4
Maximum flow rate (short-term) Qmax m³/h 90 120 200 300 350 350
Starting flow rate l/h 90 130 160 190 190 1500
Flow rate at 0.1 bar pressure
loss m³/h 35 63 115 115 105 310
Pressure loss at Q3 bar 0.25 0.16 0.25 0.4 0.4 -

Nominal diameter DN mm 200 250 300 400 500


Permanent flow rate Q3 m³/h - - - - -
Minimum flow rate Q1 m³/h - - - - -
Transitional flow rate Q2 m³/h - - - - -
Overload flow rate Q4 m³/h - - - - -
Nominal flow rate (DIN ISO
4064) Qn m³/h 250 400 600 1000 1500
Minimum flow rate horizontal Qmin m³/h 4 12 18 30 45
Minimum flow rate vertical Qmin m³/h 4 - - - -
Transition flow rate horizontal Qt m³/h 6 20 50 50 80
Transition flow rate vertical Qt m³/h 6 - - - -
Maximum flow rate (short-term) Qmax m³/h 650 1200 1500 2800 4200
Starting flow rate l/h 2500 5000 10000 15000 20000
Flow rate at 0.1 bar pressure
loss m³/h 550 800 1250 3000 6000
Pressure loss at Q3 bar - - - - -

09.10.2014 · 2
WESAN WP
BULK WATER METER | WOLTMAN

PULSE OUTPUTS
Nominal diameter DN mm 50 65 80 100 125 150
Reed switch 570* - pulse value
1 l/pulse 100 100 100 100 100 1000
Reed switch 570* - pulse value
2 l/pulse 1000 1000 1000 1000 1000 10000
Special pulse value l/pulse 25 / 50 25 / 50 25 / 50 25 / 50 25 / 50 250 / 500
IR pulse transmitter 573* l/pulse 1 1 1 1 1 10

Nominal diameter DN mm 200 250 300 400 500


Reed switch 570* - pulse value
1 l/pulse 1000 1000 1000 10000 10000
Reed switch 570* - pulse value
2 l/pulse 10000 10000 10000 100000 100000
Special pulse value l/pulse 250 / 500 250 / 500 250 / 500 2500 / 5000 2500 / 5000
IR pulse transmitter 573* l/pulse 10 10 10 100 100

* For more information about reed switch 570 and IR pulse transmitter 573 please have a look at the specific datasheet.

DISPLAY RANGE
Nominal diameter DN mm 50 65 80 100 125 150
0.5 l ... 999,999 m³ • • • • •
5.0 l ... 9,999,999 m³ •
50 l ... 99,999,999 m³

Nominal diameter DN mm 200 250 300 400 500


0.5 l ... 999,999 m³
5.0 l ... 9,999,999 m³ • • •
50 l ... 99,999,999 m³ • •

APPROVAL
Nominal diameter DN mm 50 65 80 100 125 150
D 92 / D 92 / D 02 / D 02 / D 02 / D 02 /
EC 6.132.33 6.132.33 6.132.42 6.132.42 6.132.42 6.132.43
National - - - - - -
Metrological class B•H B•H B B B B
MID (DE-13-MI001-PTB005) • • • • • -
Dynamic range (Q3/Q1) R* 63•H 100•H 100 100 100 -

Nominal diameter DN mm 200 250 300 400 500


D 02 /
EC 6.132.43 - - - -
National - 6.132 / 06.24 6.132 / 06.24 6.132 / 92.07 6.132 / 92.07
Metrological class B B B B B
MID (DE-13-MI001-PTB005) - - - - -
Dynamic range (Q3/Q1) R* - - - - -

* Standard dynamic other dynamics on request

09.10.2014 · 3
WESAN WP
BULK WATER METER | WOLTMAN

DIMENSIONS

Nominal diameter DN mm 50 65 80 100 125 150


2001 /
Overall length L mm 200 / 3001 200 225 / 3501 250 / 3501 250 300
Flange diameter D mm 165 185 200 220 250 285
Hole circle diameter PN 10 / PN
16 K mm - / 125 - / 145 160 / 160 - / 180 - / 210 - / 240
Number of screwholes PN 10 /
PN 16 pcs -/4 -/4 4/8 -/8 -/8 -/8
Screwhole diameter PN 10 / PN
16 D1 mm - / 18 - / 18 18 / 18 - / 18 - / 18 - / 22
Height H mm 75 83 89 105 115 135
Height H1 mm 123 123 154 154 154 245
Height to remove measuring
insert mm 225 225 275 275 275 475
Meter width mm 155 155 200 220 250 285
Diameter ØB mm 110 110 110 110 110 110
Weight kg 10.2 11.2 13 16 21.5 39

Nominal diameter DN mm 200 250 300 400 500


Overall length L mm 350 450 500 500 500
Flange diameter D mm 340 405 460 580 715
Hole circle diameter PN 10 / PN
16 K mm 295 / 295 350 / 355 400 / 410 515 / 525 620 / 650
Number of screwholes PN 10 /
PN 16 pcs 8 / 12 12 / 12 12 / 12 16 / 16 20 / 20
Screwhole diameter PN 10 / PN
16 D1 mm 22 / 22 23 / 27 23 / 27 27 / 30 27 / 33
Height H mm 163 193 230 290 360
Height H1 mm 245 242 290 311 361
Height to remove measuring
insert mm 475 472 520 580 660
Meter width mm 340 405 460 580 715
Diameter ØB mm 110 110 110 110 110
Weight kg 47 75 165 190 300
1
: Special body lengths on request

SPECIAL VERSIONS
- Versions with different nominal pressure on request
- Flange for ANSI and BS on request
- CuZn parts in V2A on request
- Temperature up to 90 °C on request
- Special pulse values on request
- Special overall length on request