CORONA P 423/424: Multi-Jet Meter - Wet Runner
CORONA P 423/424: Multi-Jet Meter - Wet Runner
CORONA P 423/424: Multi-Jet Meter - Wet Runner
APPLICATION
Multi-jet impeller meter with pulse output contact for control, metering or remote
display of flow rate
FEATURES
4 Especially low head loss and extended measuring range
4 Records very small amounts of water consumption
4 Withstands high load for short time periods
4 Maximum long-term accuracy
4 Forward and return metering
4 Strainer insert in inlet connection for cleaning without damaging the seal
4 Measuring data better than specified by calibration regulations
4 Easiliy replaceable pulse contact
4 Pulse contact with screw connection (standard version) or cable 2 m
4 Max. contact load 24 V (SELV) 0.2 A
CORONA P 423/424Meter for horizontal pipes 423
MULTI-JET METER | WET RUNNER
GENERAL
Meter for horizontal pipes 423
Medium temperature range °C 0 ... 30
Temperature safety °C 0 ... 50
Ambient operating temperature °C 0 ... 55
Ambient storage temperature °C 0 ... 55
Nominal pressure PN bar 10
Display range 0.05 l ... 99,999 m³
Pulse value l/pulse 0.1 (only at Qn 2.5) / 0.25 / 0.5 / 1 / 2 / 2.5 / 3 / 4 / 5 / 10 / 100 … 1000
Protection class IP 65 (IP 68 with pulse contact and cable)
TECHNICAL DATA
Nominal diameter DN mm 20 25 40 50
Nominal flow rate Qn m³/h 2.5 6 10 15
Maximum flow rate (short-term) Qmax m³/h 5 12 20 30
Transition flow rate Qt l/h 250 500 1000 1500
Minimum flow rate Qmin l/h 30 70 100 100
Starting flow rate l/h 4-6 6-8 20-25 25-30
Flow rate at 1 bar pressure loss m³/h 7 12 24 34
APPROVAL
Nominal diameter DN mm 20 25 40 50
EC D 82 / 6.131.43 D 98 / 6.131.04 D 98 / 6.131.04 D 82 / 6.131.43
Metrological class A/B/C A/B A/B A/B
13.07.2010 · 2
CORONA P 423/424Meter for horizontal pipes 423
MULTI-JET METER | WET RUNNER
DIMENSIONS
Nominal diameter DN mm 20 25 40 50
Overall length (DIN ISO 4064) L mm 190 260 300 270
Overall length with coupling L2 mm 288 378 438 -
Connection thread on meter
(ISO 228/1) Inch G1B G1¼B G2B -
Connection thread of coupling
(DIN 2999) Inch R¾ R1 R1½ -
Flange diameter (DIN 2501) D mm - - - 165
Hole circle diameter (DIN 2501) K mm - - - 125
Number of screwholes pcs - - - 4
Screwhole diameter D1 mm - - - 18
Height H mm 41 44 46 83
Height H1 mm 110 115 133 150
Diameter ØB mm 96 104 136 165
Weight without coupling kg 1.8 2.8 5.4 12.4
Weight with coupling kg 2.2 3.4 6.6 -
13.07.2010 · 3
CORONA P 423/424Meter for rising pipes 424
MULTI-JET METER | WET RUNNER
GENERAL
Meter for rising pipes 424
Medium temperature range °C 0 ... 30
Temperature safety °C 0 ... 50
Ambient operating temperature °C 0 ... 55
Ambient storage temperature °C 0 ... 55
Nominal pressure PN bar 10
Display range 0.05 l ... 99,999 m³
Pulse value l/pulse 0.1 (only at Qn 2.5) / 0.25 / 0.5 / 1 / 2 / 2.5 / 3 / 4 / 5 / 10 / 100 … 1000
Protection class IP 65 (IP 68 with pulse contact and cable)
TECHNICAL DATA
Nominal diameter DN mm 20 25 40
Nominal flow rate Qn m³/h 2.5 6 10
Maximum flow rate (short-term) Qmax m³/h 5 12 20
Transition flow rate Qt l/h 250 500 1000
Minimum flow rate Qmin l/h 30 40 100
Starting flow rate l/h 4-6 6-8 20-25
Flow rate at 1 bar pressure loss m³/h 6 12 22
APPROVAL
Nominal diameter DN mm 20 25 40
EC D 82 / 6.131.43 D 98 / 6.131.04 D 98 / 6.131.04
Metrological class A/B/C A/B A/B
13.07.2010 · 4
CORONA P 423/424Meter for rising pipes 424
MULTI-JET METER | WET RUNNER
DIMENSIONS
Nominal diameter DN mm 20 25 40
Overall length (DIN ISO 4064) L mm 105 150 200
Overall length with coupling L2 mm 203 268 338
Connection thread on meter
(ISO 228/1) Inch G1B G1¼B G2B
Connection thread of coupling
(DIN 2999) Inch R¾ R1 R1½
Height H mm 148 165 195
Height H1 mm 15 22 45
Diameter ØB mm 96 104 136
Width A mm 82 95 120
Weight without coupling kg 1.9 3.2 6.3
Weight with coupling kg 2.3 3.8 7.5