Ex Mounted Vibrator
Ex Mounted Vibrator
Ex Mounted Vibrator
Chesney Wold,
Bleak Hall,
Milton Keynes,
MK6 1NE, England
Tel: +44 (0)1908 240300
Fax: +44(0)1908 240222
Principal Advantages
Flexiblity in application
Dawson excavator mounted vibrators have been the pile. Down-crowd force applied by the excavator
designed specifically to work in place of an excavator boom, coupled with the self-weight of the pile and the
bucket to drive and extract piles. The pile can be vibrator, provides sufficient force to push the pile into
lifted to vertical using the built-in lifting chain where the ground. Naturally, the process works in reverse
it is then gripped tightly in a powerful hydraulic jaw. for pile extraction. The equipment offers a highly
Once secured, the pile is then vibrated with high productive and cost effective piling rig based around a
frequency vibrations so as to ‘fluidise’ the soil resisting standard, readily available excavator!
www.dcpuk.com
Dawson Construction Plant Ltd
Chesney Wold,
Bleak Hall,
Milton Keynes,
MK6 1NE, England
Tel: +44 (0)1908 240300
Fax: +44(0)1908 240222
Vibro Model
SPECIFICATION UNITS
EMV70 EMV300 EMV300A EMV450 EMV550
in.lbs 60 400 400 606 674
STATIC MOMENT
kgm 0.7 4.6 4.6 6.9 8.3
FREQUENCY vpm 3,000 2,400 2,400 2,460 2,500
lbs 15,730 67,420 67,420 100,000 125,592
CENTRIFUGAL FORCE
kN 70 300 300 450 550
AMPLITUDE - ins 0.134 0.58 0.58 0.5 0.51
PEAK TO PEAK mm 3.4 14.7 14.7 12 13
MINIMUM REQUIRED gpm 8 35 35 52 68
FLOW RATE l/min 30 130 130 195 256
MAXIMUM ALLOWABLE gpm 32 67 67 94 107
FLOW RATE l/min 120 250 250 350 400
MINIMUM HYDRAULIC psi 3,480 4,060 4,060 3,915 3,625
PRESSURE bar 240 280 280 270 280
H B
C
(Min. Pile Width)
www.dcpuk.com Dawson reserve the right to discontinue equipment at any time, or change specifications
or designs without notice or occuring obligations