Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MSD Programmable Fuel Booster: Installation

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

MSD Programmable Fuel Booster

PN 2351
Parts Included:
1 - Programmable Fuel Booster, PN 2351 1 - Software CD 1 - Parts Bag
1 - Harness 1 - USB Cable

The Programmable Fuel Pump Booster will increase the voltage to the fuel pump in proportion to manifold
boost pressure. The maximum voltage output is 22. The minimum output will be the battery voltage.
Note: It is recommended to have the Service Manual for your vehicle to identify the original wiring and fuel
pump relay.
RATING: Continuous Power: 275 Watt, Peak Power: 375 Watt (one minute)

INSTALLATION
The MSD Fuel Pump Booster must be wired inline with the factory fuel pump relay. The factory has safety
features built in, such as an inertia switch and high pressure shut-off which must be retained.
The MSD Fuel Pump Booster can be mounted in any position and is completely potted with a polyurethane
compound for vibration resistance. Keep the unit away from direct engine heat sources and make sure all
of the wiring reaches their connections. Also, allow access to the USB port.
Use the unit as a template and mark the mounting holes. Remove the unit and drill the holes using a 3/16"
bit. Mount the unit with the
supplied screws. With the WIRING
unit mounted, route the wiring
to their connections. Also ORANGE (18-GAUGE, long) OEM Fuel Pump Power (12V)
connect the boost pressure Pump (+) Positive lead to Fuel Pump
RED (12-GAUGE, long)
line to the booster and intake
manifold (Figure 1). RED (12-GAUGE, short) Battery (+) 12V
BLACK (12-GAUGE, short) Battery (-) Ground

CUT
INDICATES CONNECTION

FACTORY 12 VOLTS
FROM INERTIA SWITCH X
FUEL PUMP +

ORANGE
RED
USB PORT
ALERT LED

RED

BLACK
1/8” DIAMETER VACUUM
HOSE TO INTAKE MANIFOLD

Figure 1 Recommended Wiring, General Application.


M S D  •  WWW.MSDPERFORMANCE.COM • (915) 855-7123 • FAX (915) 857-3344
2 INSTALLATION INSTRUCTIONS

LED
The LED will blink fault codes to alert the following
BLINKING TWO DIGIT FAULT CODES
conditions. See charts.
12 Over Current (25 A)
13 Open Load (.5 A)
LED ALERTS
14 Over Temperature (135° C)
ON Normal Operation / No Fault
21 Under Voltage (10V)
OFF USB Power with No Fault 22 Over Voltage (17V)
23 Map Sensor Out of Range
24 Untested
31 Over Voltage - On output

MSDVIEW SOFTWARE INSTALLATION


In order to install and run the MSDView software,
the following minimum requirements are
recommended:
• Microsoft Windows XP/Vista
• Keyboard and Mouse or some other compatible
pointing device.
• Video adapter and monitor (800 X 600) or higher
resolution.
• Available USB port.
• .NET 2.0 or higher.
• Internet access.
Important: Exit all programs before installing the
MSDView software.
Note: Internet Access is required to install the MSD
View software.
1. Insert the MSD CD into your PC. The software will
automatically begin the installation feature. If the
'Autorun' feature is disabled on your PC, go to:
Start and select Run, Select your CD Drive, and
click on the Setup exe file. The MSDView wizard
will walk you through the setup. Figure 2 .NET Framework Install.

Note: If the .net framework is not installed on your


PC, the MSDView software will prompt the
download and setup. Click Accept to begin the
udpate and follow the steps (Figure 2).
2. You will need to answer several questions such
as a default location, the available disk space
and permissions (Figure 3). The MSDView will
also place a shortcut on your desktop. Once the
installation is complete, select Close to finish the
installation.

Figure 3 Select Install Folder.


M S D  •  WWW.MSDPERFORMANCE.COM • (915) 855-7123 • FAX (915) 857-3344
INSTALLATION INSTRUCTIONS 3

TUNING
It is recommended to have a fuel pressure gauge when
testing and tuning with the Programmable Fuel Pump
Booster. The fuel pressure should hold steady under full
boost. Use your boost pressure as a starting reference
point. Use the MSDView software to make the needed
adjustments for optimum performance. The following
pages explain how to load and use the MSD Software
(Figure 4).

In the example in Figure 4, as the MAP reading increases


from 14.5 p.s.i. the pump voltage will increase.

FIRST TIME PRODUCT CONNECTION Figure 4 Sample Plot.


The first time the MSD is connected to your PC, a driver
will need to be installed on your PC.
1. Connect the supplied USB harness to the PC and
the MSD. The Found New Hardware Wizard window
will open and walk you through the driver installation
steps (Figure 5).
2. The Wizard will detect the Comm Port and install the
required files. This may take a few moments.
3. The Hardware installation window will stop the setup
to alert you about the installation. Click Continue
Anyway and then Finish to complete the installation
(Figure 6).

Figure 5 Hardware Wizard.

Figure 6 Windows Alert.

M S D  •  WWW.MSDPERFORMANCE.COM • (915) 855-7123 • FAX (915) 857-3344


USING THE MSDVIEW SOFTWARE
With the MSD connected, open the software by clicking
the icon on your desktop. The screen will prompt for the
MSD product part number (PN 2351) to be selected.
The MSD software is a Graphical User Interface (GUI)
design that incorporates the familiar Windows style
operating environment. There are three tabs that you
can select; Monitor, Settings and Plots. GAUGE
SELECTOR
Monitor: The Monitor Tab allows you to view gauges
for real time readings of the voltage and amps
(Figure 7). Figure 7 Gauge Selector Box.
Plots: This tab will display the Trace editor, the Plot
value input and widow (Figure 8).

TRACE PLOT WINDOW


EDITOR

PLOT VALUE
INPUT

Figure 8.
Service
  In case of malfunction, this MSD component will be repaired free of charge according to the terms of the warranty. When
returning MSD components for warranty service, Proof of Purchase must be supplied for verification. After the warranty period
has expired, repair service is based on a minimum and maximum fee.
  All returns must have a Return Material Authorization (RMA) number issued to them before
being returned. To obtain an RMA number please contact MSD Customer Service at 1 (888) MSD-7859 or visit
our website at www.msdperformance.com/rma to automatically obtain a number and shipping information.
  When returning the unit for repair, leave all wires at the length in which you have them installed. Be sure to include a detailed
account of any problems experienced, and what components and accessories are installed on the vehicle. The repaired unit will
be returned as soon as possible using Ground shipping methods (ground shipping is covered by warranty). For more information,
call MSD at (915) 855-7123. MSD technicians are available from 7:00 a.m. to 5:00 p.m. Monday - Friday (mountain time).

Limited Warranty
  MSD warrants this product to be free from defects in material and workmanship under its intended normal use*,
when properly installed and purchased from an authorized MSD dealer, for a period of one year from the date of
the original purchase. This warranty is void for any products purchased through auction websites. If found to be
defective as mentioned above, it will be repaired or replaced at the option of MSD. Any item that is covered under
this warranty will be returned free of charge using Ground shipping methods.
  This shall constitute the sole remedy of the purchaser and the sole liability of MSD. To the extent permitted by
law, the foregoing is exclusive and in lieu of all other warranties or representation whether expressed or implied,
including any implied warranty of merchantability or fitness. In no event shall MSD or its suppliers be liable for special
or consequential damages.
  *Intended normal use means that this item is being used as was originally intended and for the original application
as sold by MSD. Any modifications to this item or if it is used on an application other than what MSD markets the
product, the warranty will be void. It is the sole responsibility of the customer to determine that this item will work for
the application they are intending. MSD will accept no liability for custom applications.

M S D  •  WWW.MSDPERFORMANCE.COM • (915) 855-7123 • FAX (915) 857-3344


© 2014 MSD LLC
FRM29438 Revised 01/14 Printed in U.S.A.

You might also like