Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
45 views5 pages

Footing Design Calculations

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 5

FOOTING DESIGN CALCULATIONS

Design Code : ACI 318M - 2011


Footing No : FC3
Column No : C3 ( 300mm X 300mm)
Analysis No : 9

Concrete Grade : C21


Steel Grade : Fy230
Clear Cover : 70 mm
Dfd : 4m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %
Design cross section by Consider : Average pressure
overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1200mm X 1200mm X 300mm

Effective Self Weight = 10.8 kN

Offset Along L (Loff) = 450 mm


Offset Along B (Boff) = 450 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 12
Combination
Critical Load Combination = [8] : 0.9 (LOAD 3: DL) +(LOAD 2: EZ)
Pcomb = 258.12 kN
P = Pcomb + Effective Self Weight x 0.9
P = 267.84 kN
Mx = 0 kNm
My = 0 kNm
P/A = 186 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 186 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm
Check For Minimum Soil Pressure:
Critical Analysis Load = 19
Combination
Critical Load Combination = [15] : 0.6 (LOAD 3: DL) -
0.71 (LOAD 2: EZ)
Pcomb = 67.37 kN
P = Pcomb + Effective Self Weight x 0.6
P = 73.85 kN
Mx = 0 kNm
My = 0 kNm
P/A = 51.28 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 51.28 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 222 mm
Beff = 1200 mm
SPu = 232.27 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 28.22 kNm
Ast Rqd = 720 sqmm
Ast (min) = 720 sqmm
Ast Prv (Distributed Across = 11 - #10 @ 120
Total Width)
= 779.68 sqmm
Bottom Reinforcement Along B:
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 206 mm
Leff = 1200 mm
SPu = 232.27 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 28.22 kNm
Ast Rqd = 720 sqmm
Ast (min) = 720 sqmm

Ast Prv (Distributed Across = 11 - #10 @ 120


Total Length)
= 779.68 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 222 mm
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 222 mm
Beff = 1200 mm
SPu = 232.27 kN/sqm
Vu = SPu X (Loff - d) X B
= 63.55 kN
φVc = 165.85 kN
Vu < φVc
One Way Shear Along B:
Critical Section @ d from Column Face

= 206 mm
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL)
+0.5 (LOAD 4: LL) +
(LOAD 2: EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 206 mm
Leff = 1200 mm
SPu = 232.27 kN/sqm

Vu = SPu X (Boff - d) X L
= 68.01 kN
φVc = 152.72 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 107 mm

Critical Analysis Load = 8


Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 214 mm
Leff = 514 mm
Beff = 514 mm
Punching Perimeter = 2056 mm
Punching Area = 439984 sqmm
SPu
= 232.27 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 273.11 kN
φVn = 756.1 kN
φVc = 499.02 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL)
+0.5 (LOAD 4: LL) +
(LOAD 2: EZ)
Pu = 334.47 kN
A2 = 0.09 sqm
A1 = 2.25 sqm

Base Area = 1.44 sqm


A1 > Base Area
Thus, A1 = 1.44
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2

Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column Area
= 2088.45 kN
Φ1Pnb > Pu, Hence Safe.

You might also like