Footing Design Calculations
Footing Design Calculations
Footing Design Calculations
Deff = 222 mm
Beff = 1200 mm
SPu = 232.27 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 28.22 kNm
Ast Rqd = 720 sqmm
Ast (min) = 720 sqmm
Ast Prv (Distributed Across = 11 - #10 @ 120
Total Width)
= 779.68 sqmm
Bottom Reinforcement Along B:
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 206 mm
Leff = 1200 mm
SPu = 232.27 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 28.22 kNm
Ast Rqd = 720 sqmm
Ast (min) = 720 sqmm
Deff = 222 mm
Beff = 1200 mm
SPu = 232.27 kN/sqm
Vu = SPu X (Loff - d) X B
= 63.55 kN
φVc = 165.85 kN
Vu < φVc
One Way Shear Along B:
Critical Section @ d from Column Face
= 206 mm
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL)
+0.5 (LOAD 4: LL) +
(LOAD 2: EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 206 mm
Leff = 1200 mm
SPu = 232.27 kN/sqm
Vu = SPu X (Boff - d) X L
= 68.01 kN
φVc = 152.72 kN
Vu < φVc
Deff = 214 mm
Leff = 514 mm
Beff = 514 mm
Punching Perimeter = 2056 mm
Punching Area = 439984 sqmm
SPu
= 232.27 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 273.11 kN
φVn = 756.1 kN
φVc = 499.02 kN
No Shear Reinforcement
Vu < φVc
Required
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column Area
= 2088.45 kN
Φ1Pnb > Pu, Hence Safe.