Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Footing Design Calculations

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

FOOTING DESIGN CALCULATIONS

Design Code : ACI 318M - 2011


Footing No : FC3
Column No : C3 ( 300mm X 300mm)
Analysis No : 9

Concrete Grade : C21


Steel Grade : Fy230
Clear Cover : 70 mm
Dfd : 4m
Dw : 10 m

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of contact = 50 %
Design cross section by Consider : Average pressure
overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1200mm X 1200mm X 300mm

Effective Self Weight = 10.8 kN

Offset Along L (Loff) = 450 mm


Offset Along B (Boff) = 450 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 12
Combination
Critical Load Combination = [8] : 0.9 (LOAD 3: DL) +(LOAD 2: EZ)
Pcomb = 258.12 kN
P = Pcomb + Effective Self Weight x 0.9
P = 267.84 kN
Mx = 0 kNm
My = 0 kNm
P/A = 186 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 186 kN/sqm
Allowable Soil Pressure = 1x200 kN/sqm
= 200 kN/sqm
Check For Minimum Soil Pressure:
Critical Analysis Load = 19
Combination
Critical Load Combination = [15] : 0.6 (LOAD 3: DL) -
0.71 (LOAD 2: EZ)
Pcomb = 67.37 kN
P = Pcomb + Effective Self Weight x 0.6
P = 73.85 kN
Mx = 0 kNm
My = 0 kNm
P/A = 51.28 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 51.28 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 222 mm
Beff = 1200 mm
SPu = 232.27 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 28.22 kNm
Ast Rqd = 720 sqmm
Ast (min) = 720 sqmm
Ast Prv (Distributed Across = 11 - #10 @ 120
Total Width)
= 779.68 sqmm
Bottom Reinforcement Along B:
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 206 mm
Leff = 1200 mm
SPu = 232.27 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 28.22 kNm
Ast Rqd = 720 sqmm
Ast (min) = 720 sqmm

Ast Prv (Distributed Across = 11 - #10 @ 120


Total Length)
= 779.68 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 222 mm
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 222 mm
Beff = 1200 mm
SPu = 232.27 kN/sqm
Vu = SPu X (Loff - d) X B
= 63.55 kN
φVc = 165.85 kN
Vu < φVc
One Way Shear Along B:
Critical Section @ d from Column Face

= 206 mm
Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL)
+0.5 (LOAD 4: LL) +
(LOAD 2: EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 206 mm
Leff = 1200 mm
SPu = 232.27 kN/sqm

Vu = SPu X (Boff - d) X L
= 68.01 kN
φVc = 152.72 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 107 mm

Critical Analysis Load = 8


Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL) +0.5 (LOAD 4: LL) +(LOAD 2:
EZ)
Pu = 334.47 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 232.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 214 mm
Leff = 514 mm
Beff = 514 mm
Punching Perimeter = 2056 mm
Punching Area = 439984 sqmm
SPu
= 232.27 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 273.11 kN
φVn = 756.1 kN
φVc = 499.02 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 8
Combination
Critical Load Combination = [23] : 1.2 (LOAD 3: DL)
+0.5 (LOAD 4: LL) +
(LOAD 2: EZ)
Pu = 334.47 kN
A2 = 0.09 sqm
A1 = 2.25 sqm

Base Area = 1.44 sqm


A1 > Base Area
Thus, A1 = 1.44
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 4
Thus, Modification Factor = 2

Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modification Factor X Column Area
= 2088.45 kN
Φ1Pnb > Pu, Hence Safe.