PRODUCT RANGE
DIESEL GENSETS
20 - 3000 kVA
50 Hz
EN
Ausonia’s factories and research laboratories are situated in Marsala. Since 1989,
Ausonia has systematically invested in the development of one of the most
modern industrial plants in the industry, in compliance with the strictest European
standards.
To date, Ausonia markets in more than thirty different countries with a network of
agents and dealers that the branches in California and Russia also help to handle.
A vast organization throughout the country and an efficient after-sales service are
distinguishing features of Ausonia.
1932
2
In an area covering 32000 sqm, more than 14000 sqm of which are built-up, the
Ausonia plants are recognized for their high degree of specialization and are outfitted
with equipment like semi-anechoic chambers for the electromagnetic compatibility
and climatic tests and for operating tests in arctic climates.
3
Key for Reading Codes
MT 0640 S W D
The codes have been chosen to represent generating
sets basic technical features allowing an immediate Engine
identification of the same according to the diagram. brand
Coolant A = Air
W = Water
Power
It is the maximum available power during
a cycle with variable power, it is possible to Power limit
use for an unlimited hours per year, between Prime Power (100%)
provided maintenance periods. The available
PRP medium power during 24 hours period Average load during 24 h
Prime Power must not exceed the percentage fixed from
endothermic engine supplier. It is possible to
read this percentage from suppliers data sheets
and it is between 70 and 80% of PRP.
Time
Power
Power limit
It is the maximum power that the genset is able Limited - Time Running Power (100%)
to do for 500 hours per year, with a maximum
LTP of 300 hours continous operation between
Limited-Time Running provided maintenance periods. It is accepted
Power that the operation using this power affects the
engine life.
Time
Products
VOLVO PENTA
from 85 to 630 kVA
MTU
from 640 to 3000 kVA
MITSUBISHI
from 1300 to 2000 kVA
JOHN DEERE
from 30 to 250 kVA
FIAT POWERTRAIN
TECHNOLOGIES
from 20 to 720 kVA
CUMMINS
from 20 to 2020 kVA
kVA
0
500
1000
1500
2000
2500
3000
4
PRODUCT RANGE
DIESEL GENSETS
20 - 2020 kVA
50 Hz
(1) Fuel consumption values refer to fuel with specific weight 0,83 Kg/dm3 and with
“inferior calorific power” of 10.000/10.200 cal/Kg.
5
PRODUCT RANGE
DIESEL GENSETS
20 - 720 kVA
50 Hz
(1) Fuel consumption values refer to fuel with specific weight 0,83 Kg/dm3 and with
“inferior calorific power” of 10.000/10.200 cal/Kg.
6
PRODUCT RANGE
DIESEL GENSETS
30 - 250 kVA
50 Hz
(1) Fuel consumption values refer to fuel with specific weight 0,83 Kg/dm3 and with
“inferior calorific power” of 10.000/10.200 cal/Kg.
7
PRODUCT RANGE
DIESEL GENSETS
1300 - 2000 kVA
50 Hz
(1) Fuel consumption values refer to fuel with specific weight 0,83 Kg/dm3 and with
“inferior calorific power” of 10.000/10.200 cal/Kg.
8
PRODUCT RANGE
DIESEL GENSETS
640 - 3000 kVA
50 Hz
(1) Fuel consumption values refer to fuel with specific weight 0,83 Kg/dm3 and with
“inferior calorific power” of 10.000/10.200 cal/Kg.
(2) Dimensions related only to the genset, electro-radiator excluded.
(3) Gross power.
9
PRODUCT RANGE
DIESEL GENSETS
85 - 630 kVA
50 Hz
(1) Fuel consumption values refer to fuel with specific weight 0,83 Kg/dm3 and with
“inferior calorific power” of 10.000/10.200 cal/Kg.
10
Standard e Option
Iveco Motors
Volvo Penta
John Deere
Mitsubishi
Cummins
Equipment for Generating Set on skidbase
MTU
Diesel engine 4 steps watercooled direct injection n n n n n n
Engine
c c c c c c
Space heater c c c c c c
Tool kit c c c c c c
Electrical diagrams n n n n n n
English n n n n n n
n = Standard c = Optional
(1) Separate electroradiator for gensets with MTU engine 4000 series
(2) Standard only for automatic gensets
11
Control Panels
PSC-M
Gauges on display
GS Voltmeter (three line voltages U V W)
GS Voltmeter (phase voltages)
Ammeter on three phases (U V W)
GS frequencymeter
Hourscounter
Power factor meter
Wattmeter
GS kVAr
GS apparent power
GS kWh
Battery voltmeter
Led warnings
Led active alarm/s
Led engine running
Led voltage / frequency GS within nominal value
Led’s electric feeding ON and electronic card OK
Protections
GS low/high voltage (27/59)
GS low/high frequency (81>f)
Battery voltage out of limits (80/45)
High engine temperature
Low oil pressure
Overspeed
GS overload (kW) (51)
Alternator overcurrent (51) PSC-M
Starting failure
Stop failure Control panel for manual operation, mounted
Emergency stop on the genset, supplied with elettronical
Phase sequence error (47)
Other features and visualization on display microprocessor logic, programmable by the
Number of starting attempts customer by means of a user-friendly interface
Messages in language
Load transient delay timer
with customer pswd access.
Hystorical report of last 10 events (max 150) It allows also to visualize the electrical and
Date and hour mechanical parameters on a LCD display.
Other devices
Back enlightened display The operation informations are available in 7
Free contact for electronic card failure languages; the choice could be selected by
Optional available
Tachometer means of the service pswd access.
Unbalanced voltage (60) It allows the supervision from remote station
High oil temperature
Alarm/stop for low water radiator by means of GSM modem with automatic SMS
Alarm without stop for fuel reserve transmission to 5 telephone numbers in case
Alarm/stop for fuel lack
Alarm/stop for broken belt
of breakdown.
Display power off Also available one communication CAN BUS
Timer for preventive maintenance port.
Oil pressure gauge
Oil temperature gauge
Water temperature gauge
Exhaust gas termometer
Fuel level indicator
Gauge for windings temperature with alarm visualization
Gauge for bearing temperature with alarm visualization
Remote management by PC
Remote management by modem GSM
ModBus mode
SMS sending in case of failure
Stop operation modes by key push-button
Free contact for cumulative failure
Refuelling card
Earth leakage protection 64/S
Programmable timer for test
Automatic switch for auxiliary circuits
Free contacts (max 16)
12
PSC-1
Gauges on display
Mains Voltmeter (three line voltages R S T)
Mains Voltmeter (phase voltages)
GS voltmeter (U V W line voltage)
GS voltmeter (phase voltages)
Ammeter on three phases (U V W)
GS frequencymeter
Hourscounter
Power factor meter
Wattmeter
GS kVAr
GS apparent power
GS kWh
Battery voltmeter
Mains frequencymeter
Led warnings
Change-over state indication
Led active alarm/s
Led engine running
Led voltage / frequency GS within nominal value
Led voltage / frequency mains within nominal value
Led’s electric feeding ON and electronic card OK
Led automatic operation mode
Protections
GS low/high voltage (27/59)
GS low/high frequency (81>f)
Battery voltage out of limits (80/45)
PSC-1 High engine temperature
Low oil pressure
Control panel for automatic mains failure (AMF) Overspeed
and manual operation, mounted on the genset, GS overload (kW) (51)
supplied with elettronical microprocessor Alternator overcurrent (51)
Starting failure
logic, programmable by the customer by means Stop failure
of a user-friendly interface with customer pswd Emergency stop
Phase sequence error (47)
access. Fuel lack allarm
It manages as the supervision of the genset, Other features and visualization on display
Number of starting attempts
as the supervision of the mains parameters, Engine preheating timer
included the Mains/GS Change-Over Switch Timer lack/mains return
Timer engine cooling cycle
management. Changeover exchange timer
It allows also to visualize the electrical and Voltage and frequency mains inferior/superior limit
mechanical parameters on a LCD display. Messages in language
Load transient delay timer
The operation informations are available in 7 Hystorical report of last 10 events (max 150)
languages; the choice could be selected by Interventions counter for changeover device
Mains threephase control
means of the service pswd access. It allows as Date and hour
the supervision as the Mains/GS Change-Over Other devices
Static battery charger
Switch from remote station by means of GSM Engine preheating
modem with automatic SMS transmission to 5 Back enlightened display
Free contact for electronic card failure
telephone numbers in case of breakdown. Also Optional available
available one communication CAN BUS port. TLG opening/closing failure
TLR opening/closing failure
Tachometer
Unbalanced voltage (60)
High oil temperature
Alarm/stop for low water radiator
Alarm without stop for fuel reserve
Alarm/stop for broken belt
Alarm battery charger fault
Display power off
Timer for preventive maintenance
Oil pressure gauge
Oil temperature gauge
Water temperature gauge
Exhaust gas termometer
Fuel level indicator
Gauge for windings temperature with alarm visualization
Gauge for bearing temperature with alarm visualization
Remote management by PC
Remote management by modem GSM
ModBus function
SMS sending in case of failure
Stop operation modes by key push-button
Free contact for cumulative failure
Ammeter battery charger
Refuelling card
Earth leakage protection 64/S
Programmable timer for test
Automatic switch for auxiliary circuits
Free contacts (max 16)
13
RCT (Remote Control Technology) Parallel Panels
PSC-2
Gauges on display
Voltmeter (three line voltages R S T)
Voltmeter (phase voltages)
GS voltmeter (U V W line voltage)
GS voltmeter (phase voltages)
Ammeter on three phases (U V W)
GS frequencymeter
Speedmeter
Hourscounter
Startingcounter
Power factor meter PSC-2
Wattmeter
GS kVAr
Control panel for automatic mains failure (AMF) and
GS apparent power manual operation, mounted on the genset, supplied
GS kWh
GS L1-L2 phase angle
with elettronical microprocessor logic, programmable
Battery voltmeter by the customer by means of a user-friendly interface
Mains frequencymeter with customer pswd access.
Led warnings
Change-over state indication AMF function allows to supervise automatically the
Led active alarm/s mains, the supervising of the genset and the Mains/
Led engine running
Led voltage / frequency GS within nominal value GS Change-Over Switch management or the back
Led’s electric feeding ON and electronic card OK sinchronization function (fugitive parallel).
Led automatic operation mode
Protections
The island operation function allows the genset to work
GS low/high voltage (27/59) in parallel operation with other gensets with various
GS low/high frequency (81>f)
Battery voltage out of limits (80/45)
function modalities (Fixed Load, Load Sharing, Droop
High engine temperature Mode) by means of analogic line signals. The control
Low oil pressure panel allows also to visualize electric and mechanical
Overspeed
Engine low speed (81<f) parameters on the LCD display interface. Informations
GS overload (kW) (51) of the operations are available in multi-language, with
Alternator overcurrent (51)
Short-circuit current (50) access to the language manager by master pswd.
Starting failure It allows furthermore or the monitoring either the remote
Stop failure
Emergency stop
management by means of GSM modem with automatic
Phase sequence error (47) SMS transmission to 5 telephone numbers in case of
TLG opening/closing failure
Unbalanced voltage (60)
breakdown.
Synchronization failure Also available one communication CAN BUS port.
Energy reverse (32)
Fuel lack allarm
Other features and visualization on display
Number of starting attempts
Engine preheating timer Optional available
Timer engine cooling cycle Unbalanced current (46)
Changeover exchange timer High oil temperature
Voltage and frequency mains inferior/superior limit Alarm/stop for low water radiator
Messages in language Alarm without stop for fuel reserve
Load transient delay timer Alarm/stop for broken belt
Hystorical report of last 10 events (max 150) Alarm battery charger fault
Interventions counter for changeover device Timer for preventive maintenance
Date and hour Oil pressure gauge
Stop operation modes by key push-button Oil temperature gauge
Other devices Water temperature gauge
Static battery charger Exhaust gas termometer
Engine preheating Fuel level indicator
Free contact for cumulative failure Remote management by PC
Back enlightened display Remote management by modem GSM
Free contact for electronic card failure ModBus options
Other functions for mains synchronization SMS sending in case of failure
Automatic sharing of isochronous active load (95) Battery charger ammeter
Automatic sharing of reactive load with permanent speed drop (95) Refuelling card command
Earth leakage protection 64/S
Total earth leakage protection 87G
Programmable timer for test
Automatic switch for auxiliary circuits
Free contacts (max 16)
Automatic sharing of reactive load without permanent speed drop (95)
14
PSC-3
Gauges on display
Voltmeter (three line voltages R S T)
Voltmeter (phase voltages) PSC-3
GS Voltmeter (U V W line voltage)
GS Voltmeter (phase voltages) Control panel for automatic mains failure (AMF) and
Ammeter on three phase (U V W) manual operation, mounted on the genset, supplied
GS frequencymeter with elettronical microprocessor logic, programmable
Speedmeter
Hourscounter by the customer by means of a user-friendly interface
Startingcounter with customer pswd access.
Power factor meter It allows the genset to work in parallel operation with
Wattmeter
GS kVAr other gensets with various function modalities (Fixed
GS apparent power Load, Load Sharing, Droop Mode) by means of analogic
GS kWh line signals.
GS L1-L2 phase angle
Battery voltmeter If provided of “Mains” card option, the control panel
Mains frequencymeter allow the AMF operation i.e. Mains/GS Change-Over
Led warnings Switch management or the back sinchronization function
Change-over state indication
Led active alarm/s (fugitive parallel).
Led engine running The control panel allows also to visualize electric and
Led voltage-frequency GS within nominal value mechanical parameters on the LCD display interface.
Led’s electric feeding ON and electronic card OK
Led automatic operation mode
Informations of the operations are available in multi-
Protections language, with access to the language manager by
GS low/high voltage(27/59) master pswd.
GS low/high frequency (81>f)
Battery voltage out of limits (80/45)
It allows furthermore or the monitoring either the remote
High engine temperature management by means of GSM modem with automatic
Low oil pressure SMS transmission to 5 telephone numbers in case of
Overspeed
Engine low speed (81<f)
breakdown.
GS overload (kW) (51) Also available one communication CAN BUS port.
Alternator overcurrent (51)
Short-circuit current (50)
Starting failure
Stop failure
Emergency stop
Phase sequence error (47)
TLG opening/closing failure
Unbalanced voltage (60) Optional available
Synchronization failure Unbalanced current (46)
Energy reverse (32) High oil temperature
Fuel lack alarm Alarm/stop for low water radiator
Other features and visualization on display Alarm without stop for fuel reserve
Number of starting attempts Alarm/stop for broken belt
Engine preheating timer Alarm battery charger fault
Timer engine cooling cycle Timer for preventive maintenance
Change-over exchange timer Oil pressure gauge
Voltage and frequency mains inferior/superior limit Oil temperature gauge
Messages in language Water temperature gauge
Load transient delay timer Exhaust gas thermometer
Historical report of last 10 events (max 150) Fuel level indicator
Interventions counter for changeover device Power management function
Date and hour Gauge for windings temperature with alarm visualization
Stop operation modes by key push-button Gauge for bearing temperature with alarm visualization
Other devices Remote management by PC
Static battery charger Remote management by modem GSM
Engine preheating ModBus option
Free contact for cumulative failure SMS sending in case of failure
Back enlightened display Battery charger ammeter
Free contact for electronic card failure Refuelling card command
Other functions for mains synchronization Earth leakage protection 64/S
Automatic sharing of isochronous active load (95) Earth leakage total protection 87G
Automatic sharing of reactive load with permanent speed drop (95) Programmable timer for test
Other functions with “Mains” card Automatic switch for auxiliary circuits
Mains voltmeter (three line voltages R S T) Free contact (max 16)
Mains voltmeter (phase voltages) Additional remote operator panel
Mains-GS phase angle Automatic sharing of reactive load without permanent speed drop (95)
Mains L1 - L2 phase angle Optional available with “Mains” card
Led voltage-frequency mains within nominal value Back synchronising function
TLR opening/closing failure
Timer lack/mains return
Mains threephase control
15
Panel in Parallel with the Mains for Peak-Shaving Service
PSC-3 Peak-Shaving
Gauges on display
Voltmeter (three line voltages R S T)
Voltmeter (phase voltages)
Mains voltmeter (three line voltages R S T)
Mains voltmeter (phase voltages)
GS Voltmeter (U V W line voltage)
GS Voltmeter (phase voltages)
Ammeter on three phase (U V W)
GS frequencymeter
Speedmeter
Hourscounter
Startingcounter
Power factor meter PSC-3 Peak-Shaving
Wattmeter
GS kVAr Control panel for automatic mains failure (AMF) and
GS apparent power
GS kWh
manual operation, mounted on the genset, supplied
GS L1 - L2 phase angle with elettronical microprocessor logic, programmable
Mains L1 - L2 phase angle
Mains - GS phase angle by the customer by means of a user-friendly interface
Battery voltmeter with customer pswd access.
Mains frequencymeter
Led warnings It allows the genset to work in parallel operation with the
Change-over state indication
Led active alarm/s mains for Peak-Shaving operation.
Led engine running The control panel allows also to visualize electric and
Led voltage-frequency GS within nominal value
Led voltage-frequency mains within nominal value mechanical parameters on the LCD display interface.
Led’s electric feeding ON and electronic card OK
Led automatic operation mode
Informations of the operations are available in multi-
Protections language, with access to the language manager by
GS low/high voltage(27/59)
GS low/high frequency (81>f) master pswd.
Battery voltage out of limits (80/45) It allows furthermore or the monitoring either the remote
High engine temperature
Low oil pressure management by means of GSM modem with automatic
Overspeed
Engine low speed (81<f) SMS transmission to 5 telephone numbers in case of
GS overload (kW) (51) breakdown.
Alternator overcurrent (51)
Short-circuit current (50)
Starting failure
Stop failure
Emergency stop
Phase sequence error (47)
TLG opening/closing failure
TLR opening/closing failure Optional available
Unbalanced voltage (60) Unbalanced current (46)
Synchronization failure High oil temperature
Energy reverse (32) Alarm/stop for low water radiator
Fuel lack alarm Alarm without stop for fuel reserve
Other features and visualization on display Alarm/stop for broken belt
Number of starting attempts Alarm battery charger fault
Engine preheating timer Timer for preventive maintenance
Timer lack/mains return Oil pressure gauge
Timer engine cooling cycle Oil temperature gauge
Change-over exchange timer Water temperature gauge
Voltage and frequency mains inferior/superior limit Exhaust gas thermometer
Messages in language Fuel level indicator
Load transient delay timer Back synchronising function
Historical report of last 10 events (max 150) Power management function
Mains threephase control Gauge for windings temperature with alarm visualization
Date and hour Gauge for bearing temperature with alarm visualization
Stop operation modes by key push-button Remote management by PC
Other devices Remote management by modem GSM
Static battery charger ModBus options
Engine preheating SMS sending in case of failure
Free contact for cumulative failure Battery charger ammeter
Back enlightened display Refuelling card command
Free contact for electronic card failure Earth leakage protection 64/S
Other functions for mains synchronization Earth leakage total protection 87G
Vector jump Programmable timer for test
Rocof df/dt Automatic switch for auxiliary circuits
Automatic sharing of isochronous active load (95) Free contact (max 16)
Automatic sharing of reactive load with permanent speed drop (95) Additional remote operator panel
< V (27) DK5740 ENEL
> V (59) DK5740 ENEL
< Hz (81)
> Hz (81)
Automatic sharing of reactive load without permanent speed drop (95)
16
Mains/GS Change-Over Switch in a separate enclosure (ATS)
Size (Ampere)
Technical Features
40 50 65 95 115 150 225 390 600 736 1050 1360 1700 2200 2500 3200 4000
4 poles n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
IP 40 degree of protection n n n n n n n n n n n n n n n n n
Change-over switch time (sec.) 1 1 1 1 1 1 2,2 2,2 2,8 2,8 3,4 3,4 3,6 3,6
Height mm 700 700 700 700 700 700 700 900 900 900 1200 2000 2000 2000 2231 2231 2231
Width mm 600 600 600 600 600 600 600 1000 1000 1000 1000 1000 1000 1000 2260 2260 2260
Length mm 350 350 350 350 350 350 350 600 600 600 600 800 1000 1000 800 1400 1400
Circuit Breaker
Size (Ampere)
Technical Features
32 50 63 80 100 125 160 200 250 320 400 500 630 800 1000 1250 1600 2000 2500 3200 4000
4 poles n n n n n n n n n n n n n n n n n n n n n
Modular type n n n n c c x x x x x x x x x x x x x x x
Box type c c c c n n n n n n n n n n n n n n n n n
Fixed configuration n n n n n n n n n n n n n n n n n n n n n
Manual control n n n n n n n n n n n n n n n n n n n n n
Opening releaser c c c c c c c c c c c c c c c c c c c c c
Aux contacts c c c c c c c c c c c c c c c c c c c c c
Withdrawable configuration x x x x c c c c c c c c c c c c c c c c c
Motorized command x x x x c c c c c c c c c c c c c c c c c
17
Canopy
The canopy is able to house the genset and all its accessories, including the automatic control and monitoring panel.
It allows the genset to function to the utmost of its rated performances whether it is installed indoors or outdoors.
The noise level depends on the type of genset and the canopy version.
Canopies of the modular type can be easily removed when necessary, in order to allow supplementary maintenance
work to be conducted on the genset. The longitudinal walls of the cowling have large, full-width doors to facilitate the
inspection and servicing work.
The door covering the electric control and monitoring panel has a transparent part to allow the operating parameters
to be checked without having to open the actual door itself. The entire canopy, completely realized with press-bend
elements and panels made of electrogalvanised metal sheet, is bolted straight on to the frame members of the base,
which have been specially designed for that purpose.
The soundproofing effect of the canopy is obtained by lining the internal walls with special high-density glass wool
panels treated with thermosetting resins. These panels are protected by hard-wearing fireproof black coloured glass
fiber fabric in fire reaction class 0.
In the Silent version, the soundproofing effect of the air flowing in and out of the canopy is obtained by specially shaped
ducts lined with the soundproof material. These elements assure, in the meantime, the protection against the rain.
The ducts in the Supersilent version are equipped with additional, shaped soundproofing elements, which have been
specially designed to lower the predominant frequencies of the diesel engine and reduce the noise level to the utmost
while keeping the dimensions down.
The soundproofed canopy is equipped with an exhaust gas silencer.
The canopy is coated inside and out exclusively with
polyester powder paints, oven-cured at 220°C in the
Ral 7035 shade.
The use of coated-zinc metal sheet and the special
painting treatment assure very high performances
against the corrosion also in outdoor installation.
Motorized louvers c c
Lifting eyebolts c c
Mechanical protection n n
n = Standard c = Optional
18
Dimensions and Weights
(1) The dimensions not include the residential exhaust muffler because, this one,
will be supplied loose to mount on the canopy roof.
19
Shelter
The shelter is a specially designed metal housing for the genset and relative accessories.
The horizontal bearing structures are made of boxed tubular profiles in very thick carbon steel.
The bed plate of the shelter consists of press-bent profiles stiffened in a particular way on a level with the zone on which
the genset’s base is positioned. The vertical bearing structures are made from very thick press-bent sheet metal.
The bearing structures of the shelter are completed by corner blocks made of ISO standardized steel electrowelded to
the structure itself.
The floor surface of the shelter’s bed plate is made from steel checker-plate.
The walls and ceiling are made of 2 mm thick electrogalvanised metal panels with edging formed by the bending press
so as to achieve a stiff structure as well as allowing the various panels to be joined together and insulating material to
be installed.
The insulating material used for lining all the walls inside the shelter consists of 50 mm high density glass wool with
class 0 fire resistance. Sheets of Aluzinc tension-levelled netting complete the insulating coating and also give the walls
an excellent appearance.
The air that cools the engines radiator and, thus, the entire shelter, can enter through one of the ends of this latter or
through side pockets. This latter method is particularly favoured when the end of the shelter is used for installing the
electric panel and relative door allowing access from the outside.
All the air inlets and outlets are equipped with rain-shielding shutters protected by galvanized netting to prevent animals
from entering.
The soundproofing of the shelter is made by soundtrap partitions or screens made from built with appropriately protected
glass-fiber panels with class 0 fire resistance.
The hot air produced by the radiator is exhausted through the end opposite to the one where the air enters.
If the shelter is soundproofed, a system formed by a certain number of soundtrap partitions made from glass-fiber panels
with class 0 fire resistance will be housed prior to the outlet shutter.
All this is able to lower the noise level to within the established values and
also ensures that the shelter as a whole is within the 0 fire reaction class.
All the shelters we manufacture are protected on the outside with
the following treatment cycle:
• Pickling of all surfaces;
• Application of an undercoat suitable for galvanized surfaces;
• Application of an aliphatic polyurethane enamel coat, in the
Ral 7035 shade;
• The internal floor surface is treated with special floor paint;
• The bottom of the shelter is treated with special tarry paint
able to withstand humidity.
Highly corrosionproof n n n
Gateway n n n
Bull’s eye for reading of parameters controlled by the electric control panel n n n
Auxiliary circuits breaking switches fed by means in outside box with breakable glass n n n
Protections and safety Fire valve with rollaway external command device in box with breakable glass n n n
Fire extinguisher c c c
n = Standard c = Optional
20
Dimensions and Weights
Soundproof
Standard
Genset 70 dB(A) a 7 mt 65 dB(A) a 7 mt
model Shelter Weight kg Shelter Shelter
L x W x H mm Insulated L x W x H mm Weight kg L x W x H mm Weight kg
model Standard model model
CU0300SWD 20' 6055x2435x2571 6540 6760 20' 6055x2435x2571 7240 20' 6055x2435x2571 7440
CU0350SWD 20' 6055x2435x2571 6690 6910 20' 6055x2435x2571 7390 20' 6055x2435x2571 7590
CU0500SWD 20' 6055x2435x2571 7390 7610 20' 6055x2435x2571 8090 20' 6055x2435x2571 8290
CU0640SWD 20' 6055x2435x2571 8910 9130 25' 7000x2435x2571 10460 30' 9125x2435x2850 11710
CU0800SWD 20' 6055x2435x2571 9630 9850 25' 7000x2435x2571 11180 30' 9125x2435x2850 12430
CU0930SWD 25' 7000x2435x2571 10780 10920 27' 8150x2435x2571 12140 30' 9125x2435x2850 12940
CU1020SWD 25' 7000x2435x2850 11230 11370 27' 8150x2435x2850 12590 30' 9125x2435x2850 13390
CU1280SWD 30' 9125x2435x2850 15910 16260 35' 10500x2435x2970 17790 40' 12190x2435x2970 18710
CU1400SWD 30' 9125x2435x2850 16980 17330 35' 10500x2435x2970 18860 40' 12190x2435x2970 19780
CU1850SWD 30' 9125x2435x2850 21350 21700 40' 12190x2435x2970 23750 TBD
CU2020SWD 30' 9125x2435x2850 21900 22250 40' 12190x2435x2970 24300 TBD
FI0300SWD 20' 6055x2435x2571 6230 6450 20' 6055x2435x2571 6930 20' 6055x2435x2571 7130
FI0350SWD 20' 6055x2435x2571 6510 6730 20' 6055x2435x2571 7210 20' 6055x2435x2571 7410
FI0400SWD 20' 6055x2435x2571 6930 7150 20' 6055x2435x2571 7630 20' 6055x2435x2571 7830
FI0720SWD 20' 6055x2435x2571 8720 8940 25' 7000x2435x2571 10270 30' 9125x2435x2850 11520
MI1300SWD (1) 30' 9125x2435x2850 12910 13260 30' 9125x2435x2850 14010 35' 10500x2435x2970 15110
MI1400SWD (1) 30' 9125x2435x2850 13060 13410 30' 9125x2435x2850 14160 35' 10500x2435x2970 15260
MI1750SWD (1) 30' 9125x2435x2850 15100 15450 35' 10500x2435x2970 16980 40' 12190x2435x2970 17900
MI1900SWD (1) 30' 9125x2435x2850 15930 16280 35' 10500x2435x2970 17810 40' 12190x2435x2970 18730
MI2000SWD (1) 30' 9125x2435x2850 17500 17850 35' 10500x2435x2970 19380 40' 12190x2435x2970 20300
MT0640SWD 20' 6055x2435x2850 9710 9930 25' 7000x2435x2850 11260 30' 9125x2435x2850 12010
MT0780SWD 20' 6055x2435x2850 10230 10450 25' 7000x2435x2850 11780 30' 9125x2435x2850 12530
MT0910SWD 25' 7000x2435x2850 12320 12460 27' 8150x2435x2850 13680 30' 9125x2435x2850 13980
MT1000SWD 25' 7000x2435x2850 12580 12720 27' 8150x2435x2850 13940 30' 9125x2435x2850 14240
MT1130SWD 25' 7000x2435x2850 13160 13300 27' 8150x2435x2850 14520 30' 9125x2435x2850 14820
MT1400SWD (1) 30' 9125x2435x2850 15620 15970 30' 9125x2435x2850 16720 35' 10500x2435x2970 17820
MT1600SWD (1) 30' 9125x2435x2850 17600 17950 30' 9125x2435x2850 18700 35' 10500x2435x2970 19800
MT1850SWD (1) 30' 9125x2435x2850 19100 19450 35' 10500x2435x2970 20980 40' 12190x2435x2970 21900
MT2100SWD (1) 30' 9125x2435x2850 19500 19850 35' 10500x2435x2970 21380 40' 12190x2435x2970 22300
MT2300SWD (1) 30' 9125x2435x2850 20300 20650 35' 10500x2435x2970 22180 40' 12190x2435x2970 23100
MT2550SWD (1) 30' 9125x2435x2850 22500 22850 35' 10500x2435x2970 24380 40' 12190x2435x2970 25300
MT2850SWD (1) 30' 9125x2435x2850 23200 23550 35' 10500x2435x2970 25080 40' 12190x2435x2970 26000
MT3000SWD (1) 30' 9125x2435x2850 23200 23550 35' 10500x2435x2970 25080 40' 12190x2435x2970 26000
VO0300SWD 20' 6055x2435x2571 6020 6240 20' 6055x2435x2571 6720 20' 6055x2435x2571 6920
VO0325SWD 20' 6055x2435x2571 6020 6240 20' 6055x2435x2571 6720 20' 6055x2435x2571 6920
VO0350SWD 20' 6055x2435x2571 6690 6910 20' 6055x2435x2571 7390 20' 6055x2435x2571 7590
VO0375SWD 20' 6055x2435x2571 6830 7050 20' 6055x2435x2571 7530 20' 6055x2435x2571 7730
VO0400SWD 20' 6055x2435x2571 6930 7150 20' 6055x2435x2571 7630 20' 6055x2435x2571 7830
VO0450SWD 20' 6055x2435x2571 7140 7360 20' 6055x2435x2571 7840 20' 6055x2435x2571 8040
VO0500SWD 20' 6055x2435x2571 7740 7960 20' 6055x2435x2571 8440 20' 6055x2435x2571 8640
VO0570SWD 20' 6055x2435x2571 8220 8440 20' 6055x2435x2571 8920 20' 6055x2435x2571 9120
VO0630SWD 20' 6055x2435x2571 8960 9180 25' 7000x2435x2571 10510 30' 9125x2435x2850 11760
(1) Dimensions related shelter suitable to contain the genset, the electro-radiator is located on external side.
21
Service
By strongly believing in this philosophy, Ausonia has created and developed an organization
dedicated to an after-sales assistance service that, along with many years of experience on
the genset market with the flexibility and quick-thinking of a dedicated enterprise, provides
services and offers solutions to its customers through excellent processes, technologies and
resources.
22
Besides installation work and preventive/corrective maintenance, our range of
services includes reconditioning existing installations, hiring out complete power
plants, help in selling second-hand equipment and advanced services through to the
sale of energy.
Installation
Maintenance
Energy Selling
Energy Rent
23
Headoffice and factory:
AUSONIA S.r.l.
Via Favara, 452/I - Z.I.
91025 Marsala - Italy
T +39.0923.7223.11
F +39.0923.721274
ausonia@ausonia.net
The illustrations, diagrams and descriptions herein are the property of Ausonia s.r.l. Duplication, even when only partial, is forbidden without written authorization from
the company. The technical data and models presented in this catalogue are not binding. The manufacturer reserves the right to modify them without prior notice.
AUSO DGS 50 (GB) Rev. 2 Ed. 03/09
All Ausonia generating sets are manufactured in compliance with the following
standards EC Directives:
“EC” MARK
• 2006/42/EC Machines
• 2006/95/EC Low Voltage
• 2004/108/EC Electromagnetic Compatibility