Service Manual: SJ-58L-C2W SJ-63L-C2W SJ-68L-C2W
Service Manual: SJ-58L-C2W SJ-63L-C2W SJ-68L-C2W
Service Manual: SJ-58L-C2W SJ-63L-C2W SJ-68L-C2W
SJ-63L-C2
SJ-68L-C2
SERVICE MANUAL
S6011SE60APWE
REFRIGERATOR-FREEZER
MODELS SJ-58L-C2W
SJ-63L-C2W
SJ-68L-C2W
In the interests of user-safety (Required by safety regulations in some
countries) the set should be restored to its original condition and only
parts identical to those specified should be used.
Refrigerant; HFC-134a
Refer to "HFC-134a COOLING UNIT" Service Manual for handling this refrigerant.
TABLE OF CONTENTS
page
ENERGY LABEL .............................................................................................................................................. 2
INSTALLATION ................................................................................................................................................ 2
CAUTIONS AND INFORMATIONS .................................................................................................................. 3
SPECIFICATIONS ........................................................................................................................................... 4
DESIGNATION OF VARIOUS PARTS ............................................................................................................. 5
LIST OF ELECTRICAL PARTS ........................................................................................................................ 6
THE FICHE ...................................................................................................................................................... 7
WIRING DIAGRAM .......................................................................................................................................... 8
FUNCTIONS .................................................................................................................................................. 10
ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS ............................................................. 13
MODIFICATION PROCEDURE OF THE DOOR OPEN SIDE ....................................................................... 21
COOLING UNIT ............................................................................................................................................. 24
REPLACEMENT PARTS LIST ....................................................................................................................... 26
SHARP CORPORATION
1
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
ENERGY LABEL
E
Fix the data part of
"ENERGY LABEL (DATA)" A
B
on the data part of C
D
"ENERGY LABEL (BASE)" E
F
G
"ENERGY LABEL (DATA)"
Data part
(This label is in Operation manual)
INSTALLATION
9cm
6cm 6cm
This refrigerator shall be used under the ordinary place condition between +5˚C and +43˚C of ambient
temperature, and also not be left under -10˚C for long days.
To be used this refrigerator within the range of the rated voltage ±6%.
2
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
3
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
SPECIFICATIONS
Items SJ-58L-C2 SJ-63L-C2 SJ-68L-C2
Type 2-Door 2-Door 2-Door
Outer dimensions Height 1620mm(63.8") 1720mm(67.7") 1820mm(71.6")
(Including spacer) Width 760mm(29.9") 760mm(29.9") 760mm(29.9")
Depth 740mm(29.1") 740mm(29.1") 740mm(29.1")
Rated storage volume 492 liter (17.4 cu.ft) 535 liter (18.9 cu.ft) 577 liter (20.4cu.ft)
F: 151 liter (5.3 cu.ft) F: 151 liter (5.3 cu.ft) F: 151 liter (5.3 cu.ft)
R: 341 liter(12.1 cu.ft) R: 384 liter(13.6 cu.ft) R: 426 liter(15.1 cu.ft)
Rated gross volume 525 liter (18.6 cu.ft) 565 liter (20.0 cu.ft) 610 liter (21.6 cu.ft)
F: 171 liter (6.1cu.ft) F: 171 liter (6.1cu.ft) F: 171 liter (6.1cu.ft)
R: 354 liter(12.5cu.ft) R: 394 liter(13.9cu.ft) R: 439 liter(15.5cu.ft)
Defrosting System Heater system
Start Automatic
Finish Automatic
Temperature control Automatic (Adjustable)
No-frost freezer Yes
Interior lamp 2
Caster 4
Evaporating pan 1
Refrigerator R glass shelf ass'y 2 3
Compartment V glass shelf ass'y 1
Vegetable case 1
Fruit case 1
R door pocket 1 2
Egg tray 2
Bottle pocket 2
Utility case pocket 1
Chilled case 1
Tube stand 2
Freezer Freezer shelf ass'y 1
Compartment Ice cube maker Twin ice cube maker
Ice storage box 1
F door pocket 2
Deodorizing system No
RATING
Items SJ-58L-C2 SJ-63L-C2 SJ-68L-C2
Rated voltage (V~) 220-240
Rated frequency (Hz) 50
Climate class T
Rated input (W) 170-190
Rated input of heating elements (W) 138-164
Refrigerant (Charging quantity) HFC-134a(120g) HFC-134a(125g) HFC-134a(130g)
Net Weight (kg) 81 83 88
PLUG TYPE
Destination mark E I
Plug cord 3wires
Plug type CS BF
Hole
with FUSED
COLOR
Items C2W
Outside color White
Inside color White
OPTIONAL ITEM
SJ-L838LD (REFRIGERATOR HINGE KITS). For changing the door to left side opening.
4
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
1. Freezer light(Lamp)
1 2. Freezer fan
18 3. Freezer shelf(F shelf ass'y)
2 4. Ice cube maker
19 5. Ice cube box(Ice storage box)
3 6. Freezer temp. control knob
4 20 7. Chilled case
8. Refrigerator temp. control knob
5 21
9. Refrigerator fan
6
7 22 10. Refrigerator light(Lamp)
11. Refrigerator shelf(R glass shelf ass'y)
8 (SJ-58L/ SJ-63L; 2 shelves, SJ-68L; 3 shelves)
9 23
12. Shelf(V glass shelf ass'y)
10 24 13. Fruit case
11 14. Vegetable crisper(Vegetable case)
25 15. Evaporating pan & cover
12 26 16. Caster
13 17. Adjustable feet(Adjustable leg ass'y)
14 18. Fan & light switch(for freezer)
27 19. Fan & light switch(for refrigerator)
15 20. Freezer pocket(F door pocket)
16 21. Water cup
22 22. Magnetic door seal(Door packing)
17 23. Utility pocket(Utility case pocket)
24. Egg holder(Egg tray)
25. Free pocket(R door pocket)
Figure D-1. External Description
(SJ-58L/63L; 1 pocket, SJ-68L; 2 pockets)
26. Bottle pocket
27. Bottle guard(Tube stand)
Hot pipe
Vegetable case
Ventilating grille Compressor
Starting relay, Overload relay(Protector)
Evaporating pan
Adjustable leg ass’y Sub. condenser
Caster
5
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
SJ-58L,63L
Compressor GLY80AA 220-240V/50Hz Cooling capacity : 197kcal/h(50Hz)
Main coil : 10.3Ω Common
Aux. coil : 14.2Ω
(at 25˚C)
SJ-68L
Compressor GLY90AA 220-240V/50Hz Cooling capacity : 220kcal/h(50Hz)
Main coil : 8.8Ω Common
Aux. coil : 14.2Ω
(at 25˚C)
6
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
(96/57/EC)
15 Maximum allowable electricity 942 989 1033
consumption (Emax) kWh/year kWh/year kWh/year
7
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
WIRING DIAGRAM
Be sure to replace the electrical parts with specified ones for maintaining the safety and performance of the set.
G : GRAY
Br : BROWN
O : ORANGE
Y : YELLOW
R : RED CONNECTED IN TERMINAL BOX
P : PINK
B : BLUE CONNECTOR
Bk : BLACK
S-B : SKY-BLUE
G-Y : GREEN-YELLOW
W : WHITE
F-THERMOSTAT (G)
(BR)
3 4
(R)
TM
R F DEFROST
FM FM TIMER
F R THERMO. 2 1
R-FAN THERMO. FUSE
L L HEATER
(W) (BK)
(O)
(S-B) R-FAN DEFROST
2 4 THERMO. 3 HEATER
PROTECTOR
(Y)
SOURCE CORD
8
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
CABINET ASS’Y
F LAMP BOX ASS’Y
LAMP SOCKET BR-1
F-LAMP(10W) 1 1
L W-2
2 2
E. V. COVER ASS’Y
LEAD EV-COVER ASS’Y GY-1
1 1
F-FAN MOTOR FM OR-1
2 2
3 3 R-1
F-THERMOSTAT BR-2
4 4
Y-1
5 5
DEF. THERMO. ASS’Y BL-1
6 6
7 7 BK-1
FUSE ASS’Y 8 8 W-1
OR-3
9 9
(W-1)
1 1
DEF. HEATER ASS’Y Y-2
2 2
DOOR SWITCH
(OR-1)
3 (PUSH CLOSE) 3
BL-2
1 (NEUTRAL) 1
SB-1
4 (PUSH OPEN) 4
(W-2)
2 (PUSH OPEN) 2
(R-FAN SB-2
1 1
THERMO. HEATER) BR-3
2 2
OR-3
3 3
R FAN THERMO.
4 4 OR-2
TERMINAL BOX
SKY-BLUE
RUNNING CAPACITOR EARTH
PROTECTOR
1 COMPRESSOR
L
C
E
M
N
A
SOURCE CORD STARTING
RELAY
TERMINAL COVER
9
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
FUNCTIONS
1. ADJUSTABLE TEMPERATURE CONTROL
(1) Temperature control of freezer
Thermostat (senses freezer temperature) operates on ON/OFF switchover to control the compressor and
cool air circulating fan (F-fan motor) , and allows the freezer temperature to keep at a suitable temperature.
However adjust the freezer temp. control knob as follows depending upon the storing condition of foods.
MED
4 5 KNOB PURPOSE
3 6
2 SETTING
1 7
MIN MAX MAX(Coldest) For making ice rapidly or fast freezing.
Coldest
When restocking with fresh food.
MED For normal freezing.
For storing frozen food for a short period (up to one month).
FREEZER TEMP. CONTROL
Figure F-1. MIN When frozen food or ice cream is not stored.
When the temperature of the refrigerator is higher, R-fan thermo. senses the temperature and the
refrigerator is cooled efficiently by running of R-fan motor.
R-fan thermo. heater energizes when the door is opened intend to promote to running of R-fan motor.
NOTE: The refrigerator temperature is affected also by the freezer temperature. If the freezer temp.
control knob is set at the position "MAX", the temperature tends to be lower than the following
values, and if set at near the position "MIN", temperature tends to be higher.
If the refrigerator is operated for a long time with the freezer temperature control sets the "MAX"
position, foods stored in the refrigerator compartment may also freeze.
When refrigerator temperature control sets to the "CHILLED ZONE", some foods stored may
freeze.
In this case adjust control set back to the "MED" position.
When refrigerator temperature control sets to the "CHILLED ZONE", some foods stored in chilled
case may also become frozen.
2. DEFROSTING
(1) No defrosting operation is necessary (2) Where is melted frost brought
No defrosting operation is necessary. 1. Melted frost is brought into the evaporating
As this machine is so designed that a built-in pan at the bottom of the set and is evaporated
evaporator cools air and a fan circulates cooled here by the heat of sub condenser.
air, neither the freezer nor the refrigerator is 2. Be sure that the evaporating pan is inserted
frosted, though the evaporator is frosted. correctly and is level.
The frosted evaporator is defrosted automatically
due to the function of defrosting timer and heater,
requiring no defrosting operation.
(3) The following circuit diagrams in the table show automatic defrosting function of the refrigerator with
timer and defrost thermostat.
Compressor
Timer motor
Thermo. fuse
SOURCE
Defrost
thermostat (ON)
Figure F-3.
2. Defrosting Defrost thermostat ON Compressor stops The timer contact is changed to start
(Time 20 to 30 min.) Timer motor stops defrosting, the timer motor stops, and
Thermostat Timer contact power is supplied to the defrost heater.
It takes about 20 to 30 min. to defrost.
Compressor
Timer motor
Defrost heater TM COMP little time. When much frosted, the def-
rosting takes much time.
Defrost
thermostat (ON)
Figure F-4 .
3. Drain Defrost thermostat OFF Compressor stops When the defrost thermostat becomes
(Time approx. 5 min.) Timer motor running OFF, the timer motor starts running.
Thermostat Timer contact During the operation time (delay time
of defrost time) defrosted water is
Compressor
Timer motor
Defrost
thermostat (OFF)
Figure F-5.
4. Restart Defrost thermostat OFF Compressor running Timer contact is changed to cooling
(Time approx. 5 min.) Timer motor stops operation and the compressor starts
Thermostat Timer contact running and the timer motor stops.
Defrost thermostat contact becomes ON
Compressor
Timer motor
Defrost
thermostat (OFF)
Figure F-6.
11
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
(4) As a reference to determine the causes of trouble, malfunction and phenomena are described below.
Refer to the following when repairing.
1. Disconnection of defrost heater
As off-cycle defrosting is performed, the defrosting time is extremely prolonged. Each time defrosting is
started, the freezer temperature rises and a portion of ice and stored foods are melted.
2. Melted thermo. fuse or opened-circuit due to the defect of defrost thermostat.
When the above mentioned trouble occurs in cooling operation, the timer motor does not run, defrosting
will not take place, and consequently freezing is caused. In the above mentioned condition, when the timer
shaft is turned by hand to defrost, the timer motor runs during the operation time. However, the motor stops
from the time when the contact is changed, and freezing causes.
NOTE:
As the thermo. fuse assembly is intended to prevent dangers, do not use it under shorted condition even
for a short period.
3. DEW PREVENTION
The hot pipe, namely D.P.-condenser, is arranged around the flange part of
cabinet and the C-partition plate, preventing dew from being generated on
the cabinet.
NOTE:
D.P.-condenser pipe may be felt hot if touched by hand while the
compressor is in operation.
If you are asked about this, please explain that the hot pipe serve to Hot pipe
prevent the dew generation.
Figure F-7
4. INSPECTION OF INITIAL STARTING
(1) Inspection of cooling unit
1. Set the temperature control knob to "MAX" and check that the compressor starts to operate.
2. Depress the door switch to run the fan and check that cool air is blown out of the cold air outlet of the
freezer and the refrigerator.
3. When the compressor does not work, check that the timer is not set to "defrost" position.
4 It takes about an hour and a half or two hours to put food in the refrigerator after starting operation.
NOTE:
After return the temperature control knob to "MED" position.
When the refrigerator is operated initially after installed, the compressor may vibrate excessively for 1 to 2
min. However, vibration becomes normal if it is continuously operated.
12
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY REPAIRING.
Damper thermo.
RA sealer A
R air guider A
Defrost timer
RA sealer D
Dial sealer
Fan cover
Figure A-1
Damper
thermostat
3 +1 mm
5 +1 mm
Stick thermo.
25 + 2 mm cap. sealer
NOTE
Less than 12 mm
Figure A-2
13
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
OVERLAP 15mm
RA sealer A OVERLAP 15mm
Dial sealer
RA sealer D
A sealer
RA sealer A RA sealer A thermo. cap. RA sealer B RA sealer C RA sealer A
[Bottom side]
A sealer
thermo. cap.
RA sealer A RA sealer A
Figure A-3
(3) Fixing of Defrost timer, R fan thermo. ass'y cover to R-C box cover.
Defrost timer
Cut
10 + 5mm
G R fan thermo.
ass’y
Nylon band
Fan cover
SEC. G-G
Figure A-4
14
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
R-fan motor
Propeller fan 80
Fan clamp
Lamp 15W
Warning label
R lamp box
Figure A-5
Lamp socket
ALUMINUM TAPE
Lamp 15W
R lamp box
Figure A-6
Lamp socket
Fan motor
Figure A-7
15
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
Figure A-8
F
Fan clamp
Propeller fan 80
2.3 + 0.5mm
Shaft
Detail of F
Fan clamp
Slit of each Fan clamp and Propeller fan
should not be at same position.
Slit
Figure A-9
Warning label
Lamp 15W
Figure A-10
16
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
Fuse ass’y
F-thermostat
E.V cover
sealer D
(2 pieces)
Figure A-11
Sticking start
Sticking start
Figure A-12
17
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
(2)-1 Stick U-sealer handle to Fan motor holder A. Fan motor holder A
C
7 + 2mm
0 + 1mm
U-sealer handle
C
U-sealer handle
SEC. C-C
Figure A-13
Fan motor
Figure A-14
4 + 0.5mm
Shaft
Detail of D
Figure A-15
18
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
(3) Setting of Fan motor ass'y , Defrost thermo. ass'y and Fuse ass'y
E.V cover
sealer C
L-band C
E
Lead E.V-
cover ass’y Defrost
thermo. ass’y
Tapping E
more than more than Aluminum
3.5mm 3.5mm screw
tape Set metal side below
[FRONT SIDE] Aluminum
tape
10 + 5mm
E.V
cover ATTENTION
L-band C
Fuse
ass’y Turn up is lead wire Not come out of claw
Figure A-16
F-thermostat 4
1 2 3
(BROWN, inserted)
4 5 6 Fan motor 9
Defrost thermo. 5 7 8 9
(PINK) Fuse 8
(WHITE)
Defrost thermo. 6
(BLUE) Fuse 7
(BLACK)
Figure A-17
Vinyl tape
60
mm
Figure A-18
19
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
20mm
R10mm R10mm
230mm
Note
• Bending radius of
capillary tube should be
from R5mm to R10mm.
13mm 42mm
20mm
Figure A-19
BROWN
(back side)
Figure A-20
SEC. F-F
F
Figure A-21
20
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
These kits are used to change the refrigerator doors from right to left opening.
if you wish to change the door to left opening for some reason, such as restricted installation
space, ask your authorized service agent for this modification. by SJ-L838LD OPERATION MANUAL
Stopper spring L Stopper spring L Door cap cover Door cap cover
A Bottom hinge L B C D E
(for upper door) (for lower door) (for upper door) (for lower door)
F Door hole cover G Screw and Cover H Silicon grease J Screw cap for handle
(Spare)
Tools required
Phillips and slotted screwdrivers
Drill bit ( 3.8 mm)
Socket wrench or spanner (8 mm) :The socket wrench or spanner is used to detach and attach hinges.
Caution
Always disconnect the power plug from the wall outlet before performing work.
Caution should be taken when handling the doors.
These are heavy and could cause personal injury if mishandled.
Always tighten screws securely. May cause personal injury if door becomes unlatched and falls.
Reattach doors paying careful attention to the door alignment. Failure to fit the door
correctly might cause the cool air to leak out and lower the cooling performance.
Fitting Instruction
1 Preparation/Removing Doors
1. Remove Evaporating pan cover, Upper hinge cover, and Top cover.
(Carefully remove Upper hinge cover using a screwdriver, making sure that the door is not damaged.)
2. Remove Upper hinge and Spacer, and detach Upper door by lifting off the center hinge.
3. Remove Center hinge and detach Lower door by lifting off the bottom hinge. Remove the 2 Hole caps, replace them on
the screw holes of the removed center hinge, then screw in G (screw and cover) in the center hole.
4. Remove Bottom hinge. Remove the 3 screws on the left side, then install them in the screw holes of Bottom hinge.
1
1
2
1 G
3 2
G 3
3
3
4 1
Figure M-1
21
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
2 4
2 5,6
16mm
F
1 2
27mm
172mm
3
D 2 172mm
1 3
4 B 7
2
4 3
E
3 5mm
1 1 8
(J) 5-8
2
F
2 4 9
2
4 C
Figure M-2
22
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
3
4 9
9
3
3
12mm
6 3.5 + 0.5mm
2 2
2 +1.0mm
2 7
A
1 8
Figure M-3
23
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
COOLING UNIT
Evaporator
Back condenser
Suction pipe
Sub. condenser
Compressor
Capillary tube
Dryer
24
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
Dryer
Capillary tube
Charge pipe
Hot pipe
Evaporator
Charge pipe
Compressor
Suction pipe S.P. connector
Sub. condenser Back condenser
Hot pipe
to Dryer
25
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
ELECTRIC PARTS
1-1 RTHM-A097CBEZ F-thermostat 1 1 1 AX
1-2 RSTT-A144CBEZ Starting relay 1 1 1 AW
1-3 QSWTDA035CBE0 Defrost timer 1 1 1 BB
1-4 PDMP-A046CBEZ Damper thermo 1 1 1 AX
1-5 FTHM-A028CBKZ Defrost thermo. assembly 1 1 1 AN
1-6 RMOTRA040CBE0 Fan motor 1 1 1 AZ
1-7 QSOCAA074CBEZ Lamp socket 1 1 1 AP
1-8 RLMP-A012CBE0 Lamp 1 1 1 AH
1-9 QACC-A097CBE0 Source cord 1 1 1 AV
1-9 QACC-A104CBE0 Source cord (for U.K.) 1 1 1 AZ
1-10 QSW-PA090CBZA Door switch 1 1 1 AS
1-11 RHOG-A084CBE0 Protector 1 1 - AN
1-11 RHOG-A105CBE0 Protector - - 1 AV
1-17 FFS-TA055CBKZ Fuse assembly 1 1 1 AL
1-20 FW-VZA144CBEZ Lead ev-cover assembly 1 1 1 AK
1-21 FHETBA146CBEZ Def. Heater assembly 1 1 1 AZ
1-22 FCNW-A517CBK0 Relay cord s assembly 1 1 1 AM
1-23 QCNW-A671CBE0 Relay wire RC 1 1 1 AD
1-25 QTAN-A032CBE0 Terminal block 1 1 1 AE
1-27 RMOTRA061CBEZ Fan motor 1 1 1 AW
1-28 RLMP-A029CBEZ Lamp15W 1 1 1 AH
1-29 QSOCAA072CBEZ Lamp socket 1 1 1 AN
1-30 FTHM-A029CBKZ R fan thermo assembly 1 1 1 AQ
1-31 RC-EZA190CBEZ Running capacitor 1 1 1 AW
MECHANICAL PARTS
2-2 JKNB-A036CBFB F-temp. control knob 1 1 1 AD
2-4 LPLTMA568CBEZ Fl plate AL. 1 1 1 AF
2-7 FLEGPA077CBKZ Leg holder L assembly 1 1 1 AQ
2-7-1 FAJS-A009CBK0 Adjustable leg assembly 2 2 2 AD
2-7-2 LHLD-A533CBPZ Leg holder L 1 1 1 AL
2-8 FLEGPA078CBKZ Leg holder R assembly 1 1 1 AQ
2-8-2 LHLD-A534CBPZ Leg holder R 1 1 1 AP
2-10 PSPAVA083CBEA Upper hinge spacer 1 1 1 AD
2-11 PSPAVA084CBEA Bottom hinge spacer 1 1 1 AC
2-12 PSPAVA075CBEA Center hinge spacer 1 1 1 AD
2-13 DHNG-A363CBMZ Upper hinge assembly 1 1 1 AE
2-14 DHNG-A365CBMZ Bottom hinge R assembly 1 1 1 AE
2-15 DHNG-A364CBMZ Center hinge R assembly 1 1 1 AF
2-16 GCOV-A191CBFZ E.v cover 1 1 1 AS
2-17 LCRA-A010CBE0 Fan clamp 2 2 2 AD
2-19 LHLD-A389CBF0 Motor cushion 2 2 2 AF
2-20 NFANPA020CBFA Propeller fan 100 1 1 1 AE
2-21 PSEL-B845CBEZ E.v cover sealer A 1 1 1 AC
2-22 PSEL-B846CBEZ E.v cover sealer B 1 1 1 AC
2-23 PSEL-A415CBE0 E.v cover sealer C 1 1 1 AC
2-24 PCOVPA164CBFA Terminal cover 1 1 1 AE
2-25 PCOV-A253CBFA F lamp cover 1 1 1 AC
2-26 PCOV-A254CBFA R lamp cover 1 1 1 AF
2-27 GCOVPA119CBRA R-c box cover 1 1 1 AS
2-28 HGRL-A184CBRA Fan louver 1 1 1 AU
2-29 GCOV-A162CBFJ Upper hinge cover 1 1 1 AD
2-30 PCOV-A255CBFA Fan cover 2 2 2 AD
2-31 JKNB-A033CBFB R-temp. control knob 1 1 1 AD
2-36 PCAP-A006CBFW Screw cover 2 2 2 AB
2-37 PCAP-A056CBFF Screw cover B 2 2 2 AC
2-38 PGID-A156CBFZ R air guider A 1 1 1 AG
2-41 PSEL-B848CBEZ A-sealer thermo. cap 1 1 1 AC
2-49 LSTPPA108CBFA Chilled stopper 2 2 2 AC
2-50 NFANPA019CBFA Propeller fan 80 1 1 1 AM
2-51 PBOX-A121CBFA F lamp box 1 1 1 AF
2-52 PBOX-A122CBFA R lamp box 1 1 1 AM
2-53 LHLD-A536CBFA R fan motor holder A 1 1 1 AF
2-54 LHLD-A537CBFA R fan motor holder B 1 1 1 AE
2-55 HGRL-A181CBFA Multi louver L - - 1 AN
2-55 HGRL-A186CBFA Multi louver M - 1 - AM
2-55 HGRL-A188CBFA Multi louver S 1 - - AG
2-56 PFPFPB233CBFZ R-louver insu. L - - 1 AG
2-56 PFPFPB239CBFZ R-louver insu. M - 1 - AF
2-56 PFPFPB248CBFZ R-louver insu. s 1 - - AE
2-57 PSEL-B843CBEZ A-sealer r-louver - - 2 AC
2-57 PSEL-B857CBEZ A-sealer r-louver - 2 - AC
2-57 PSEL-B861CBEZ A-sealer r-louver 2 - - AC
26
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
27
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
To have your order filled promptly and correctly, please furnish the following information.
28
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
1 2 3 4 5 6
DOOR PARTS
A A
3-9
3-6
3-5 3-5-2
3-8
B 3-9 B
4-18
3-9 4-18
3-9
4-18
C 4-18 C
3-25 5-34
3-7
5-3
3-5-3
3-15 3-9
4-18 3-5-1
3-9
4-18 3-5-2
D D
5-36
3-9 3-15-3
4-18 3-9
4-18
3-9
4-18
5-37
3-9
4-18
E 5-5 E
3-19
5-4
3-18
F F
5-35
5-1
3-17
G G
3-15-1
3-15-2
SJ-58L-C2
H SJ-63L-C2 H
SJ-68L-C2
1 2 3 4 5 6
29
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
1 2 3 4 5 6
CABINET PARTS
A A
5-9 2-29
2-99 2-13
B B
2-106
5-31
2-105 2-10
5-33
5-6
2-36
2-104
2-91
5-17
2-103
5-32
C 2-90 C
2-93
5-18 1-10
2-37
2-49
2-36
2-49
4-3 2-15 2-12
2-97
2-95
2-96 2-95
2-93
D 5-19 2-96 D
2-11
5-26 5-14
2-8
2-14
5-24
E E
2-7 2-7-2 2-8-2
2-7-1 2-7-1
5-13
5-25
5-15
F 5-28 F
5-16
5-29
G G
SJ-58L-C2
H SJ-63L-C2 H
SJ-68L-C2
1 2 3 4 5 6
30
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
1 2 3 4 5 6
CABINET PARTS
A A
2-19
1-6
2-63
2-64 2-19
2-21
2-17
2-16 1-5
4-1 2-65
2-20 1-20
2-4
B B
2-23 2-22
1-17
1-1
2-28
2-59
1-29
2-30 2-69
2-81
C C
1-8
2-51 1-31
2-25 90-2
2-66
1-21
1-23
2-2 1-4 4-10
2-72
2-67 2-24
2-79
D 2-78 D
2-41
6-18
1-3
2-84 2-83 6-5
2-82
1-30
2-79 2-73
2-71
2-77
2-38 2-80
2-30 2-79
2-27 2-74 1-27
2-53 1-9
E E
2-50
2-54 6-29
2-31
2-17 1-7 6-28
1-28
1-22
6-30
90-8 2-52
6-11
4-17 4-1
F 6-1 F
6-18 1-11
2-86
6-15
2-57 6-9
6-2 1-25
2-56 4-15
2-26 6-21
2-55 6-27 6-6
1-2
G G
6-4
6-3-1
6-3
6-3-2
SJ-58L-C2
H SJ-63L-C2 H
SJ-68L-C2
1 2 3 4 5 6
31
SJ-58L-C2
SJ-63L-C2
SJ-68L-C2
52APWE/ 52APWI/ 56APWE/ 56APWI/ 60APWE/ 60APWI 2000 (06U0.12E) Printed in Japan
32