Astm D8278 - 19
Astm D8278 - 19
Astm D8278 - 19
for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: D8278 − 19
safety concerns, if any, associated with its use. It is the D5853 Test Method for Pour Point of Crude Oils
responsibility of the user of this standard to establish appro- D6371 Test Method for Cold Filter Plugging Point of Diesel
priate safety, health, and environmental practices and deter- and Heating Fuels
mine the applicability of regulatory limitations prior to use. D6821 Test Method for Low Temperature Viscosity of Drive
1.4 This international standard was developed in accor- Line Lubricants in a Constant Shear Stress Viscometer
dance with internationally recognized principles on standard- D6896 Test Method for Determination of Yield Stress and
ization established in the Decision on Principles for the Apparent Viscosity of Used Engine Oils at Low Tempera-
Development of International Standards, Guides and Recom- ture
mendations issued by the World Trade Organization Technical D7279 Test Method for Kinematic Viscosity of Transparent
Barriers to Trade (TBT) Committee. and Opaque Liquids by Automated Houillon Viscometer
D7962 Practice for Determination of Minimum Immersion
2. Referenced Documents Depth and Assessment of Temperature Sensor Measure-
2.1 ASTM Standards:2 ment Drift
D97 Test Method for Pour Point of Petroleum Products D8210 Test Method for Automatic Determination of Low-
D445 Test Method for Kinematic Viscosity of Transparent Temperature Viscosity of Automatic Transmission Fluids,
and Opaque Liquids (and Calculation of Dynamic Viscos- Hydraulic Fluids, and Lubricants Using a Rotational
ity) Viscometer
D2162 Practice for Basic Calibration of Master Viscometers E563 Practice for Preparation and Use of an Ice-Point Bath
and Viscosity Oil Standards as a Reference Temperature
D2500 Test Method for Cloud Point of Petroleum Products E644 Test Methods for Testing Industrial Resistance Ther-
and Liquid Fuels mometers
E1750 Guide for Use of Water Triple Point Cells
E2877 Guide for Digital Contact Thermometers
1
This test method is under the jurisdiction of ASTM Committee D02 on 2.2 ISO Standard:3
Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of ISO 17025 General requirements for the competence of
Subcommittee D02.07 on Flow Properties.
Current edition approved July 1, 2019. Published July 2019. DOI: 10.1520/ testing and calibration laboratories
D8278-19.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
the ASTM website. 4th Floor, New York, NY 10036, http://www.ansi.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
Nominal temperature range,A °C 0 to 100 100 to 175 0 to 150 10 to 175 –60 to 60 (Note 1)
Display resolution, °C minimum 0.01 0.01 0.01 0.001 0.1
Accuracy,B °C minimum 0.02 0.05 0.02 0.007 0.1
Sensor type (Note 1 and Note 2) PRT, Thermistor PRT PRT, Thermistor PRT PRT
Sensor sheath,C max diameter, mm 7 7 7 7 4.2
Sensor length,E max mm 25 25 18 40 20
DCT immersion depth by D7962,F mm (see <40 <40 <40 <105 <40
6.2)
Measurement drift,G less than °C (see 6.3) 0.02 0.02 0.02 0.01 0.1
Response time, less than or equal to, sec- 10 10 10 10 10
onds (see 6.4)
Calibration data,H (see 6.5) 2 to 4 2 to 4 2 to 4 2 to 4 2 to 4
D02–DCT ID D02-DCT12 D02-DCT13 D02-DCT14 D02-DCT15
Test Method D4539, D6371 D4539, D6371 D3829, D4684, D6821, D8210
D6896
Parameter DCT Criteria
then a minimum of two data points are sufficient. The calibra- competency in temperature calibration which is traceable to a
tion data should be distributed over the calibration range and national calibration laboratory or metrology standards body.
included in calibration report. The calibration report should be An example is a calibration laboratory with an ISO 17025
obtained from a calibration laboratory with demonstrated accreditation that includes temperature calibration.
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
--``,`,,``,````,`,`,``,,,,``,```-`-`,,`,,`,`,,`---
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/