Data Sheet GS 80-200 30
Data Sheet GS 80-200 30
Data Sheet GS 80-200 30
Requested data
1 Pump type End Suction Volute Pump Fluid Water
2 Number of pumps / Reserve 1 / 0 Liquid temperature °C 20
3 Flow US g.p.m. 840 Kin. viscosity mm²/s 1.005
4 Head m 35 Vapour pressure kPa 2.34
5 Geodetic head m 0 PH value
6 Inlet pressure (pin) kPa 0 Density kg/m³ 998.3
7 Available system NPSH Solids Weight % 0
8 Ambient temperature °C 20
Pump
9 Pump name GS 80-200 /30 Frequency Hz 50
10 Design End Suction Volute Pump Installation type with ISO base, motor
11 Manufacturer EBARA Impeller Max. mm 222
12 Speed 1/min 2900 Diameter Designed mm 185
13 No. of Stage 1 Min. mm 165
Materials
22 Casing FC250
23 Impeller CAC406
24 Shaft SUS431eq.
25 Case wear ring CAC406
26 O-ring NBR
27 Mechanical Seal SiC/Carbon/FKM
Motor
28 Manufacturer EBARA Standard Insulation class F
29 Type 200L_30_3_380 Phases 3~
30 Specific design TEFC/B3/AESV1S / 50 Hz / Pole pairs 1 Frame size 200L
31 Rated power kW 30 Weight kg 240
32 Number of poles 2 Electric voltage V 380
33 Speed 1/min 2955 Electric current A 59.5
34 Degree of protection IP55
35
Remarks
Performance curve Pump name GS 80-200 /30
H/ m Head — 50 Hz
— 48.04 Hz
35 % 51 % 63 %
72 %
78 %
40
81.6%
81.6%
35
A1
30
Frequency
20
10
▕◄ Application range ►▏
0
P₁ / kW Power input P1
25
24.11
20
15
10
5
0
η tot75.29
/% Total efficiency
60
50
40
30
20
10
0
NPSH / m NPSH-values
7
6
5.996
5
4
3
2
1
0
0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 840
850 900 950 1000 Q / US g.p.m.
Dimensions Pump name GS 80-200 /30