Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

NIVETEC NT CT Nivelco NIVOCONT K

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

NIVOCONT

C O N D U C T I V E L E V E L S W I TC H E S

S W I T C H E S
L E V E L
A P P L I C AT I O N
Level switches, based on the conductivity principle, can be applied to liquids with conductivity higher than 10 µS/cm. For detecting the level, probes are immersed into
the tank. These probes (and the tank wall if conductive) serve as contacts of an electric circuit. Probes can be of single or multiple rod versions. A maximum of 4 probe-
rods can fit in the multiple probe with an additional reference probe if tank wall is not conductive. The probe length should be in accordance with the level to be detected.
Filling liquid in the tank will change the electrical conductivity between tank wall (or the reference probe) and probes. The established connection will be converted and
will activate a relay providing for output.

VERSIONS
Level switch and probe Compact level switch

DIN rail mounted, 1 or 2 1 or 2 channel switching


channel switching unit unit in plastic housing
Probe set with aluminum or with 1 1/2" BSP process
plastic housing featuring 1 1/2" connection
BSP process connection Probe-rods up to 3m
Probe-rods up to 3m

M A I N F E AT U R E S
Level Switches Probe and relay in one unit
KRK-512 KRK-522 KKH-22
Level switching 2 independent relay outputs for 1 level Probe and relay in one unit
Filling-emptying control 2 independent relay outputs for 2 1 or 2 independent relay outputs for pump
Selectable NO/NC relay function independent levels control or differential level switching
Adjustable sensitivity 2 relay outputs for pump control Selectable NO/NC relay function
Adjustable delay time, Selectable NO/NC relay function Switch on/off delay
Adjustable delay ON and delay OFF time Adjustable delay ON and delay OFF time Adjustable sensitivity
Delay time display Adjustable sensitivity AC/DC versions
AC/DC versions AC/DC versions Delay time display
Adjustable delay ON and delay OFF time

PROBES Multi probe socket

Single probe socket Submersible probe

M6 nut
M6 nut

KS-201 KSK-201 KSH-2 KSH-3

ACCESSORIES D E R AT I N G
Probe Separator
DIAGRAM
Pressure (MPa)

Temp.
°C

KLN-2 KLP-201 KLP-204 Maximum allowed pressure-temperature values


Material: 1.4571 Material: PP Material: PVDF for steel probe socket
L E V E L S W I TC H E S Liquid level switching

m
1 vessel, 1 level 1 vessel, 1 level

o
c
KRK-512-5 KRK-512-5

.
1 vessel, 2 levels 2 vessels, 1-1 level

o
c
KRK-522- KRK-522-

l
1 vessel, 1 level 1 vessel, 2 levels
C O M PAC T L E V E L S W I TC H E S

e
v
M6 nut

i
KKH-212-5 KKH-222-5

Liquid level monitoring


1 vessel, 2 levels 2 vessels, 2-2 level
n
.
w

2 parallel operating outputs


KRK-512-5 or KKH-212-5 KRK-522- KKH-222-5
w

KRK switches: KKH compact level switches:


A1, A2 ...........power supply S ...................cable shielding* Un .................power supply (KKH-222) 1, 2, 3, 4 ......probe-rods
C ...................reference probe 15, 16, 18 .....1st relay output A1, A2 ...........power supply (KKH-212) 15, 16, 18 .....relay output
E1 .................upper level probe 25, 26, 28 .....2nd relay output C ...................reference probe
w

E2 .................bottom level probe * Mind the right connection


krk5s08a0602b

Nivelco reserves the right to change technical data without notice!


S P E C I F I C AT I O N
Multi Probe Sub-
Single Probe
Aluminum housing Plastic housing mersible
Probes
KSP- KSS- KSN- KSH- KSH- KSH- KSH- KSH- KSH- KSH- KSK-
201 201 201 202 203 204 301 302 303 304 201
Number of probes 1 2+s* 3+s* 4+s* 1+s* 2+s* 3+s* 4+s* 1
with
Process connection 3/8” BSP 1 1/2” BSP integrated
cable
carbon
Probe socket material PP 1.4571 1.4571 PP –
steel
Housing – Aluminium cast PBT ABS
Insulation of socket – PFA – –
max.
Medium temperature max. +200 °C (see Derating Diagram) max. +80 °C
+80 °C
max.
Pressure max. max. 1,6 MPa max. 0,3 MPa –
0,3 MPa
Electrical connection with rubber cap M20x1,5 cable gland Pg9**
Ingress protection IP 20 IP 65 IP 68
Mass (w.o. probe) 0,1 kg 0,4 kg 0,04 kg
*s = reference probe
** cable diameter: Ø 4…7 mm

ORDER CODES
Level Switches Compact Level Switches

Single channel
NIVOCONT K R K - 5 1 2 - NIVOCONT K K H - 2 2-

Power supply Code


Function Code Power supply Code
24…240 V AC / DC 5
1 channel 1 24…240 V AC / DC 5

Double channel 2 channel 2

NIVOCONT K R K - 5 2 2 -

Power supply Code


Separator
230 V AC 1

110 V AC 2 NIVOCONT KLP-204 For aluminum housing probes


NIVOCONT KLP-201 For plastic housing probes and
24 V AC / DC 4 compact level switches

Probe (not all combinations available) Probe

NIVOCONT K S - 0 NIVOCONT K L N - 2

Type Code Housing Code No. of Probes Code Length Code Length Code
Single probe, PP socket P Aluminum 2 1 pc + ref. probe 1* 0m 0 0m 0
Single probe, Plastic 3 2 pcs + ref. probe 2 1m 1 0,5 m 5
S
carbon steel socket
3 pcs + ref. probe 3 2m 2
Single probe, 1.4571 N
4 pcs + ref. probe 4 3m 3
Housing H * Only with plastic
housing
Submersible K
S P E C I F I C AT I O N S O P E R AT I O N
KRK-512-5
L E V E L S W I TC H E S
Filling

KRK-512-5 KRK-522-
(galvanic isolation) 110, 24 V
Power supply (Un) 24…240 V AC/DC 230 V AC AC/DC max
level
– 15…+10% min

Power consumption max. 2 VA / W max. 4,5 VA / W


Ambient
– 20 °C…+55 °C
temperature
Probe voltage 3,5 V AC 5 V AC Emptying
Probe current max. 0,2 mA max. 1 mA
Sensitivity Adjustable: 5 kOhm…100 kOhm
100 nF (100 kOhm sens.)
Cable capacitance max. 4 nF max
800 nF (5 kOhm sens.) level
Fixed on-delay (t1) min
1,5 sec –
On and off-delay 0,5…10 sec
1x SPDT 250 V 8A, AC1 2x SPDT 250V 16A, AC1
Output
24 V DC min. 500 mW 24 V DC min. 500 mW
terminal block, max. 2,5 mm2
Electrical connection
with insulation 1,5 mm2
Electrical protection Class II. Class II. Class II.
Mechanical
DIN EN 60715 rail
connection
Ingress protection IP 20
Mass 72 g 240 g

KRK-522-
C O M PA C T L E V E L S W I TC H E S Operation

KKH-212-5 KKH-222-5

24 V…240 V AC/DC
Power supply (Un)
– 15…+10%
Power consumption max. 2 VA / W max. 4 VA / W
Ambient temp. – 20 °C…+50 °C
Process temperature max. +80 °C
Pressure 1 bar
Number of probes 2+s* 4+s*
Probe voltage 3,5 V AC
Probe current max. 0,2 mA max. 0,4 mA
Sensitivity Adjustable: 5 kOhm…100 kOhm
Fixed on-delay 1,5 sec
On and off-delay 0,5…10 sec
Output 1x SPDT 250 V 8A, AC1 2x SPDT 250V 16A, AC1
2x M20x1,5 for Ø6…12 mm cables, terminal block
Electrical connection
max. 2,5 mm2 / with insulation 1,5 mm2
Electrical protection Class II.
Process connection 1 1/2” BSP
Probe socket
PP
material
Housing material Polycarbonate
Ingress protection IP 67
660 g 800 g
Mass
(without probe stems) (without probe stems)

*s = reference probe