SR-MT Maximum Power Point Tracking Series: Solar Charge Controller
SR-MT Maximum Power Point Tracking Series: Solar Charge Controller
SR-MT Maximum Power Point Tracking Series: Solar Charge Controller
Tracking Series
Solar charge controller
User Manual
Specification
Mode SR-MT2420 SR-MT2430
Battery voltage 12V / 24V 12V / 24V
Charging current 20A 30A
Over discharge current 20A 20A
Dear users:
The full name of the MPPT is maximum power point tracking. It is an advanced
charging way which could detect the real-time power of the solar panel and the
maximum point of the I-V curve that make the highest battery charging efficiency.
Contrast with the traditional PWM controller, MPPT controller could play a
maximum power of the solar panel so that a larger charging current could be supplied.
Generally speaking, the MPPT controller’s energy utilization efficiency is 15%~20%
higher than PWM controller.
The voltage of the solar panel is about 12V when General controller is charging while
the highest voltage of the solar panel is about 17V, so it doesn’t play the largest power
of the solar panel. MPPT controller overcome this problem by adjusting the input
current and voltage constantly to realize the largest input power.
Meanwhile, the maximum power point will change due to the surrounding
temperature and sunshine condition. MPPT controller will adjust the parameter
constantly according to different conditions to make the system working in the largest
power point.
Ⅲ. Using Suggestion
1. The controller will identify the battery voltage automatically. Please connect the
battery first and ensure the connection is reliable.
2. MPPT controller is designed according to solar panel’s I-V curve, so when the
controller connect the general constant voltage DC source, the controller may not
work.
3. Advice is installed in the ventilated and heat dissipated environment due to the
controller will fever during operation.
4. The controller will detect the surrounding temperature to compensate the battery
charging voltage so ensure the controller and battery is in the same environment.
5. Choosing the proper cable with enough capacity to avoid redundant power loss in
the circuit. Too much circuit loss may lead to wrong judgment.
6. Full charge is very important for the battery. The battery should be full charged at
least once a month or the battery will suffer permanent damage. The battery can
be full charged only when the input power of the battery is more than power
consumption of the load.
7. Please do not dip the controller into the corrosive liquid or the controller will be
damaged and release harmful gas.
8. The solar panel’s terminal voltage may exceed human safety voltage when
connect 24V system, when manipulation is needed, please use insulating tools
and ensure the hands dry.
9. Because the battery store lots of energy, do not allow the battery short circuit in
any case. We suggest tandem connect a fuse on the battery
10. The battery may release combustible gas, please far away from the spark.
11. Ensure the children are far away from battery and controller
12. Please abide by the battery manufacturer’s safety suggestion.
1. Fix the controller: Fix the controller onto the surface of the specific place. Keep
a certain distance between the controller and fitting surface to assure heat
dissipation
2. Wire preparation: Adopt the wire matching the current,be aware of the length
of wire, strip 5mm insulation of one side of the controller terminal and try to
decrease the length of the connected wire so that a reduction in electrical loss.
3. Connect to the battery: connect the battery wire to the controller firstly, Pay
attention to the “+” and “–”, in case of reverse connection. If connected well, the
indicator light will be on. Otherwise, please check the connection. If reverse
connection, controller will not working but not damage the controller.
4. Connect to the solar panel: Pay attention to the “+” and “–”, do not reverse connected. If
ample sunshine, controller will show charging mode. Or should check the connection is right
or wrong. If solar panel under the sunshine, will produce voltage immediately. If use 24V
or over, the solar panel voltage will exceed to body safety voltage, please prevent you self
Installation Image:
Ⅴ. Controller Image
Setup Button
LED display
+ - + - + -
1. Charge indication: 4 LED light flashing cycle, when the solar panel output
voltage reaches a certain value.
2. Battery capacity indication: When no charging, LED1 ~ LED4 indicates battery
capacity approximation.
3. Mode indicating light: when the mode indicating light is on, it indicates that the
LED displaying value is under controller mode, the light will be off if no keys
operation within 5s.
4. Fault indicating light: when the fault indication light is on, it indicates that the
LED displaying value is controller fault code; the light will be off if no keys
operation within 5s, if fault exists, the indicating light will flash.
①
Float charging, single
② flash.
Slow flash.
② (light for 1s,off for 1s,the cycle is 2s) Boost charging.
Single flash.
③ (light for 0.1s,off for 1.9s,the cycle is Float charging.
2s)
Fast flash.
④ (light for 0.1s,off for 0.1s,the cycle is Equalizing charge.
0.2s)
Double flash.
⑤ (light for 0.1s,off for 0.1s,reopen for Current limited
0.1s,reclose for 1.7s,the cycle is 2s) charging.
Slow flash.
② (light for 1s,off for 1s,the cycle is 2s)
The battery has been over
discharged.
Fast flash.
③ (light for 0.1s,off for 0.1s,the cycle is 0.2s) The battery is over voltage.
When there has no sunlight, the light intensity will fall to start point, the controller
will open the load after confirming the start signal and the load will start work, the
load will be closed when the working time reach at the set value. The specific set
value meets with the set method of load working mode.
2. Manual mode (15):
Under manual mode, user can control the load by key; no matter it is day or night.
This mode applies to special load or debugging.
3. Debug mode (16):
This mode applies to debugging; the load will be shut when receiving light signal and
it will be on without light signal. The debug mode is easy to examine the validity of
the system.
4. Normally on mode (17):
Under this mode, the load will be normally on; this mode is fit for the load which
requires 24 hours power supply.
Ⅷ. Operating Instruction
2. Mode adjusting
When press the button over 3s, LED1~LED4 start flashing, press the button again,
state of LED will be changed. According to the number displayed in LED, can
calculate the mode value, please stop press the button when you adjusted the mode
you want. Wait for 10s setting mode quit auto, or press the button over 3s, setting
mode quit.
The load will be on by light control and will be off after delaying
1
for 1 hour
The load will be on by light control and will be off after delaying
2
for 2 hour
The load will be on by light control and will be off after delaying
3
for 3 hour
The load will be on by light control and will be off after delaying
4
for 4 hour
The load will be on by light control and will be off after delaying
5
for 5 hour
The load will be on by light control and will be off after delaying
6
for 6 hour
The load will be on by light control and will be off after delaying
7
for 7 hour
The load will be on by light control and will be off after delaying
8
for 8 hour
The load will be on by light control and will be off after delaying
9
for 9 hour
The load will be on by light control and will be off after delaying
10
for 10 hours
The load will be on by light control and will be off after delaying
11
for 11 hour
The load will be on by light control and will be off after delaying
12
for 12 hour
The load will be on by light control and will be off after delaying
13
for 13 hour
The load will be on by light control and will be off after delaying
14
for 14 hour
15 Manual mode
16 Debug mode
17 Normally on mode
Attention: if no key operation within 5s, the LED will be shut; or if there exist
some fault, the fault indicating light will flash all the time until the fault has been
removed.
Ⅸ. Protections.
1. Waterproof protection
Waterproof degree::IP32.
2. Input power limit protection
When the PV power exceeds the rated power, controller will limit the PV power under
the value of rated power so as to prevent the controller from being damaged.
3. Battery reverse connection protection
Battery reverse connection will not damage the controller but the system will stop
working.
4. The voltage of PV input terminal is over value
When the voltage of PV input terminal is over value, controller will shut the PV input
automatically.
5. Short circuit protection of PV input terminal
Load short circuit will not damage the controller but controller will stop output.
6. Over load protection
When the load current exceed 1.25 (or 1.5) time of rated current and last for 10s (5s),
the load will stop output.
7. Load short circuit protection
When the load is short circuit, controller will stop output without any damage.
8. Solar panel reverses connection protection
The reverse connection of solar panel won’t do any damage to the system.
9. Reverse charging protection at night
Prevent the battery from discharging through solar panel at night.
10. TVS lightning protection
11. Over temperature protection
When inside temperature of the controller is over value, the controller will lower
charging power or stop charging.
The battery indicating light The battery is over discharge, it will recover if charging
flashes slowly, without to full voltage.
load output.
All the indicating light is Battery power supply fault, please check if the
off. connection is correct.
Fault code E1 The input voltage of PV terminal is over value, please
check if the PV parameter is matched, charging will be
recovered if the voltage become lower.
Fault code E2 The power of PV input terminal is over value, check if
the PV power parameter is matched.
Fault code E3, there is no The PV input terminal maybe has been short circuit;
check out if it is right.
charge.
Fault code E4. The load is short circuit, after the fault been debugged;
it will recover the next day or after pressing the key for
a long time.
Fault code E5 The load power exceeds rated power, please reduce the
electric equipment, it will recover the next day or after
pressing the key for a lone time.
The charging loop of fault The controller is overheated; it will recover when the
code E6 and E8 are normal, temperature is lower.
but there is no charge.
Ⅺ. Parameters
Parameters Value
Model SR-MT2420 SR-MT2430
System voltage 12V/24V Auto
Rated load current 20A
Rated charging current 20A 30A
260W/12V; 400W/12V;
Max. input power of PV system
520W/24V 800W/24V
Stand by self-consumption <20mA
Max. input voltage of solar panel <150V
Transfer efficiency ≤97%
MPPT tracing efficiency >99%
Over voltage protection 16.5V;×2/24V
Limited charge voltage 15.5V;×2/24V
Equalizing charging voltage 15.2V;×2/24V(25℃)
Equalizing charging interval 30 days
Boost charging voltage 14.4V;×2/24V(25℃)
Float charging voltage 13.8V;×2/24V(25℃)
Return voltage when over discharge 12.5V;×2/24V
Over discharge voltage 11.0V;×2/24V
Boost charging time 2 hours
Equalizing charging time 1 hour
Temperature compensation -4.0mv/℃/2V;
Over temperature protection Yes
Light-operated open voltage 5V
Light-operated close voltage 6V
Light-operated delay time 5min
Working temperature -35℃ ~ +65℃;
IP level IP32
Weight 1.18kg 1.56kg
Max. wiring dimension 12mm2
Altitude ≤3000m
Dimension 180.7×115×72(mm) 180.7×170×72(mm)
Installation dimension 175.7×70(mm) 173.7×125(mm)
2. SR-MT2430
1. Solar panel power & efficiency curve (12V system)
②There’s shadow at the top left corner of PV module, the tracing efficiency is
99.61%
③Simulate tree shade covered PV module, the tracing efficiency is 97.49%.