418 - EWWD-VZ Chiller Series - Product Profile

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

VZ Chiller series

Water cooled inverter chiller

The highest peak in chiller technology


The highest peak
in chiller technology
EWWD-VZ chiller series
An increasing demand for high efficient HVAC systems
drives our product development mission.
By answering market demands and offering
new opportunities we anticipate on the future HVAC
market needs.
8.0

7.7

7.1

2
ESEER
8.5
up to

7.9 Top efficiency ESEER

The EWWD-VZ chiller series were

developed and manufactured to answer

the growing market demands on high

efficient chiller series.

Thanks to the continuous evolution

in components‘ technology, we are

the first to reach the highest peak

in chiller efficiency and technology.

3
Single compressor
450 kW - 1,053 kW

Full inverter water cooled chiller

Highest efficiency in the market in its category

TOP CLASS EFFICIENCY


Dual compressor & dual circuit unit
1,200 kW - 2,100 kW
ūū 2 of everything:
2 compressors,
2 expansion valves,
2 condensers,...

New condenser design with integral oil separator

High efficient flooded heat exchangers

Unique Daikin single screw compressor technology

5
The highest peak in chiller technology

Why choose
EWWD-VZ chiller series?

Top class efficiency: ESEER up to 8.5 – EER up to 5.8

New generation Daikin inverter Power input



single screw compressors 100%
Traditional screw compressor
Importance of ESEER: 90%

Power consumption significantly reduced at part 80%


loads where the machine will run for 97% 73%
of the operation hours (Eurovent load profile)
60% - 32 %
50%

40% Screw compressor


INVERTER driven
30%

20%

10%

0%

0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 110%
Compressor Load

Why choose an inverter chiller? Why are we better than others?


ūū -25% energy consumption ūū Full inverter capacity control down to 20%
ūū -25% CO2 emissions ūū No inefficient mechanical unloading slides
ūū -25% running costs
ūū Return on investment < 2 years vs non-inverter chiller

45%
Running hours

non inverter Daikin EWWD-VZ


Compressor speed
41%
40%
100%
% of full load power input

33% 35% 100%

80% 30%
Savings
23% 25%
60% Others
20% 50% Mechanical
unloading < 50%
40% 15%

10% Full inverter


20% control down to
3% 5% 20% Daikin min load!
EWWD-VZ
0% 0%
100% 75% 50% 25% Unit capacity Full Load 50% Load 20% Load (min) Compressor load

6
New generation high efficiency
heat exchangers

ūū Flooded type technology allowing maximizing unit performances


ūū Latest technology enhanced surface tubes

Evaporator tubes: Condenser tubes:


ūū Outside: Cavities for optimized ūū Outside: Optimized for
nucleate boiling condensation
ūū Inside: Helical structure ūū Inside: Helical structure

Optimized design

Pressure drops reduced by half


ūū meaning 1°C lower condensing temperature
ūū + 3.5 % efficiency

Did you know that you can maximize


your BREEAM and programme score
and LEED green building programme
score with the Daikin HVAC solutions?

7
The highest peak in chiller technology

2 Compact unit
ūū Small footprint, ideal for installation through existing doorways

Width reduced below 900mm


with knock down panel options*
* 900 kW unit size

1245 mm 865 mm

40 % footprint reduction in comparison


to traditional water cooled series thanks to:
REFRIGERANT

1. New single pass condenser technology


.. High heat exchange performances thanks to
couterflow design WATER
.. Low water pressure drops < 30 kPa

2. New integrated oil separator technology Oil separator


.. Low oil carry over
.. Low refrigerant pressure drops
Condenser

3 Application flexibility
Widest operating envelope in its range:
The large operation range makes this chiller ideal
for a variety of applications: Up to 65°C hot
water production
and with optimized
Condenser water (°C) efficiencies

Widest operating envelope


in its category…
not only for comfort cooling
Heat pump
Evaporator Water
Evaporator Water up to +20°C
down to -8°C

Brine/Ice Comfort Data center


storage

Evaporator water (°C)

8
The highest peak in chiller technology

4 Connectivity

Remote access with one click


ūū Remote monitoring
ūū System optimization
ūū Preventive maintenance
Dashboards

Remote HMI access Remote


maintenance report

Daikin on site
Cloud platform

Via LAN or GSM modem


Remote software upgrade Diagnostics

5 F uture readiness:
Choose for today’s best solution
and be ready for the future!
R-134A refrigerant, still today the best All VZ units are ‘new refrigerant ready’!
possible choice: Possibility to retrofit them in the future with lower
ūū Still most efficient refrigerant. GWP refrigerants (HFO blends).
ūū Availability in high quantitates
and at competitive prices.
ūū No phase out planned in F-GAS regulation.
ūū Classified as non flammable

9
Supporting tools
Product video

Marketing material Green Building Design


Highest Focus

All marketing material and tools for the 14%


12%
Encourages specification and
design of energy efficient
solutions for construction and

EWWD-VZ range can be downloaded from


operation of the infrastructure
10%

% score
Score credits per BREEAM 8%
category. 6%

the business portal. Each category carries a


certain weight that affects the
score.
4%
2% Green Building Design
0%
Asset finder > Campaign > VZ chiller series Levels of certification:

ell ls

ilie g
no ce
te Tra tion

nd St de rt
n

ec rs

he ion

W e
te

er
gy

y
R ein

us ake sig

ag
g
ed o
l w ria

as

at
n
er

olo
at nsp

t
an old
va

an ollu

rit

W
ca ate

b
en
≥ 85% Outstanding

h
es

P
M
d

In

d
an
≥ 70% Excellent

gr
n

Lo

e
Typical HVAC energy

bo
≥ 55% Very good

ap
In
ar

sc
C
≥ 45% Good consumptions in buildings

nd
La

La
≥ 30% Pass
< 30% Unclassified
11 Offices : up to 48% energy
*Based on BREEAM International New Construction 2015

Hotel : up to 70% energy

Source : 1. EIA Commercial Buildings Energy consumption survey ; 2. Energy conservation


centre, 2009

Web
Want to know more about this product?
Have a look at our dedicated webpage:
www.daikineurope.com/vzchillerseries

Technical specifications - single compressor range


Standard efficiency, standard sound
Cooling only /Heating only EWWD600VZSSA1 EWWD700VZSSA1 EWWD760VZSSA1 EWWD890VZSSA1 EWWDC10VZSS
Cooling capacity Nom. kW 610 704 757 894 1,039
Heating capacity Nom. kW 756.7 877.8 943.2 1,107 1,292
Power input Cooling Nom. kW 110 132 142 162 196
Heating Nom. kW 140 166 179 201 244
EER 5.51 5.31 5.31 5.52 5.28
ESEER 7.25 7.30 7.40 7.27 7.52
COP 5.42 5.27 5.28 5.5 5.3
Dimensions Unit Height mm 2,120 2,120 2,120 2,290 2,480
Width mm 1,180 1,180 1,180 1,240 1,340
Depth mm 3,460 3,460 3,460 3,690 3,690
Weight Unit kg 2,892 2,928 2,941 3,451 4,237
Operation weight kg 2,977 3,033 3,053 3,611 4,488
Water heat Type Flooded single pass shell and tube
exchanger - Water volume l 88 88 96 134 156
evaporator Water flow rate Cooling Nom. l/s 29.3 33.8 36.3 42.9 49.9
Heating Nom. l/s 29.6 34.2 36.7 43.5 50.4
Water pressure drop Cooling Nom. kPa 80.0 106.0 89.0 98.0 104
Heating Nom. kPa 82 108 90 100 106
Water heat Type Single pass shell and tube
exchanger - Water volume l 81 102 102 126 217
condenser Water flow rate Cooling Nom. l/s 34.5 40.2 43.1 50.7 59.4
Heating Nom. l/s 36.46 42.33 45.47 53.38 62.35
Water pressure drop Cooling Nom. kPa 54.0 41.0 46.0 44.0 33.0
Heating Nom. kPa 60 44 51 48 36
Compressor Type Inverter driven single screw compressor
Quantity 1
Sound power level Cooling Nom. dBA 101 105 105 105 108
Sound pressure level Cooling Nom. dBA 82 86 86 86 89
Operation range Evaporator Cooling Min.~Max. °CDB -3~20
Condenser Cooling Min.~Max. °CDB 16~63
Refrigerant Type / GWP / Circuits R-134a / 1,430 / 1
Refrigerant charge Per circuit kg 100 110 110 170 180
TCO₂eq 143 157 157 243 257
Piping connections Evaporator water inlet/outlet (OD) 141.3 141.3 141.3 168.3 219.1
Condenser water inlet/outlet (OD) 168.3 168.3 168.3 219.1 219.1
Unit Starting current Max. A 179 214 245 295 344
Running current Cooling Nom. A 171 202 220 249 300
Max. A A 256 306 350 421 491
Power supply Phase/Frequency/Voltage Hz/V 3~/50/400

10
High efficiency, standard sound
Cooling only/Heating only EWWD-VZXS 450 500 610 710 800 900 C11
Cooling capacity Nom. kW 449 501 613 713 793 901 1,053
Heating capacity Nom. kW 553 617.2 756.7 882.2 984.6 1,110 1,302
Power input Cooling Nom. kW 81.1 89.6 108 128 146 158 192
Heating Nom. kW 102 112 138 163 185 199 240
EER 5.53 5.58 5.64 5.54 5.43 5.67 5.46
ESEER 7.51 7.92 8.10 8.20 8.22 7.92 8.17
COP 5.45 5.49 5.48 5.42 5.33 5.58 5.43
Dimensions Unit Height mm 2,090 2,120 2,230 2,290 2,480
Width mm 1,180 1,220 1,240 1,340
Depth mm 3,460 3,690 3,830
Weight Unit kg 2,968 2,911 3,102 3,470 3,451 4,257 4,552
Operation weight kg 3,098 3,006 3,274 3,648 3,611 4,518 4,860
Water heat Type Flooded single pass shell and tube
exchanger - Water volume l 70 88 136 134 168 199
evaporator Water flow rate Cooling Nom. l/s 21.6 24.0 29.4 34.2 38.0 43.2 50.4
Heating Nom. l/s 21.7 24.2 29.7 34.5 38.4 43.7 50.9
Water press. drop Cooling Nom. kPa 89.0 63.0 59.0 63.0 55.0 67.0 58.0
Heating Nom. kPa 90 64 60 64 56 68 59
Water heat Type Single pass shell and tube
exchanger - Water volume l 81 92 126 145 126 217 241
condenser Water flow rate Cooling Nom. l/s 25.4 28.3 34.7 40.4 45.2 50.9 59.9
Heating Nom. l/s 26.68 29.78 36.53 42.60 47.53 53.59 62.85
Water press. drop Cooling Nom. kPa 31.0 28.0 22.0 20.0 24.0 25.0 25.0
Heating Nom. kPa 34 31 24 22 27 28 27
Compressor Type Inverter driven single screw compressor
Quantity 1
Sound power level Cooling Nom. dBA 97 99 101 105 108
Sound pressure level Cooling Nom. dBA 78 80 82 86 89
Operation range Evaporator Cooling Min.~Max °CDB -3~20
Condenser Cooling Min.~Max. °CDB 16~65
Refrigerant Type / GWP / Circuits R-134a / 1,430 / 1
Refrigerant charge Per circuit kg 95 100 110 170 180
TCO₂eq 136 143 157 243 257
Piping connections Evaporator water inlet/outlet mm 141.3 168.3 219.1
Condenser water inlet/outlet mm 168.3 219.1
Unit Starting current Max A 155 173 179 214 256 295 344
Running current Cooling Nom. A 126 140 171 201 229 249 299
Max A 222 247 256 306 366 421 491
Power supply Phase/Frequency/Voltage Hz/V 3~/50/400

Premium efficiency, standard sound


Cooling only/Heating only EWWD-VZPS 505 715 910
Cooling capacity Nom. kW 505 718 908
Heating capacity Nom. kW 619.7 885.3 1,115
Power input Cooling Nom. kW 87.5 126 156
Heating Nom. kW 110 161 196
EER 5.77 5.66 5.81
ESEER 8.15 8.48 8.25
COP 5.62 5.49 5.68
Dimensions Unit Height mm 2,090 2,430 2,480
Width mm 1,180 1,330 1,340
Depth mm 3,690 3,830
Weight Unit kg 3,247 4,082 4,346
Operation weight kg 3,375 4,349 4,660
Water heat Type Flooded single pass shell and tube
exchanger - Water volume l 96 168 199
evaporator Water flow rate Cooling. Nom. l/s 24.2 34.4 43.5
Heating Nom. l/s 24.4 34.7 44
Water press. drop Cooling Nom kPa 55.0 42.0 44.0
Heating Nom. kPa 56 43 45
Water heat Type Single pass shell and tube
exchanger - Water volume l 126 217 241
condenser Water flow rate Cooling Nom. l/s 28.5 40.6 51.2
Heating Nom. l/s 29.93 42.7 53.83
Water press. drop Cooling Nom. kPa 15 17 19
Heating Nom kPa 17 18 21
Compressor Type Inverter driven single screw compressor
Quantity 1
Sound power level Cooling Nom. dBA 99 105
Sound pressure level Cooling Nom. dBA 80 86
Operation range Evaporator Cooling Min.~Max. °CDB -3~20
Condenser Cooling Min.~Max. °CDB 16~65
Refrigerant Type / GWP / Circuits R-134a / 1,430 / 1
Refrigerant charge Per circuit kg 100 150 180
TCO₂eq 143 215 257
Piping connections Evaporator water inlet/outlet mm 141.3 219.1
Condenser water inlet/outlet mm 219.1
Unit Starting current Max A 173 214 295
Running current Cooling Nom. A 138 200 247
Max A 247 306 421
Power supply Phase/Frequency/Voltage Hz/V 3~/50/400

11
Why choose Daikin?

Daikin is Europe‘s leading manufacturer


and global n°1 of highly energy-efficient heating,
cooling, ventilation and refrigeration solutions
for residential, commercial and industrial
applications.

Why choose Daikin chillers?

›› The widest and most flexible chiller portfolio

›› Worldwide experience
in chiller design and manufacturing

›› The highest efficiency for every installation

›› Quality and reliability

Daikin Europe N.V.  Naamloze Vennootschap Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)

Daikin Europe N.V. participates in the Eurovent Certification


programme for Liquid Chilling Packages (LCP), Air handling
FSC units (AHU) and Fan coil units (FCU), Check ongoing validity
of certificate online: www.eurovent-certification.com or using:
www.certiflash.com

ECPEN17 - 418 10/16
The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.

Printed on non-chlorinated paper. Prepared by La Movida