INJkon 00/1.0/ Manual
OPERATING
MANUAL FOR
CONTROL SYSTEM
OF INJECTION
MOLDING MACHINE
Page 1 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Business Mission
E-mail –
customercare@Streamlinecontrols.com
Web - www.streamlinecontrols.com
Page 2 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
PREFACE
For letter usage and maintenance of control system, detail study of this operating
manual will be helpful.
Page 3 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
CONTENTS
Page 4 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
(A) SPECIFICATIONS:
Input
Power:
Voltage -- 0-440Vac ± 10%
Frequency -- 49-50 Hz
Consumption -- 30VA Max.
Control:
Thermocouple -- J / K type - Isolated
Proximity/ -- NPN (NO type)
Limit switches 10-30 Vdc - 50 mA Max.
Output
Environment
Page 5 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
(B) INTRODUCTION
INJkon is a complete proven & reliable control system for Injection Molding Machine.
System consists of three units.
(1) Display unit
(2) Input/Output drivers
(3) C.V.T. (Optional)/Transformer
Junction card
Junction card is junction between all Input/Output driver cards & Display unit.
Require Power supply for driver cards and display unit provide by this junction card.
Thermocouples for measuring barrel temperature are also connected to this card.
This package has some obvious advantages over existing conventional Electrical
Systems. This occupies lesser space then conventional system. The simplicity of wiring from
solenoids to systems or limit switches to system and from Thermocouples to system makes it
easier and less time consuming for commissioning. This system has no moving parts, so
periodical maintenance is drastically reduced and there for reliability is definitely improved.
Function like suck back ON-OFF, Heating ON-OFF and Cycle Time Interlock makes this
system much more superior then the conventional system.
Page 6 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
(C) FEATURES
User friendly programming through an extensive membrane keypad for easy operator
interface (Details of manual mode operations available is appended on separate sheet)
Three different programs for Ejector operations provide to suit the operational needs with
various molds.
Thermocouple "Open" & "Reverse" conditions are self detected and are displayed as "Opn"
and "rev" respectively.
Mold Safety interlock provided in case of abnormal pressure rise while the mold is getting
closed (For that pressure switch input has to be provided.)
Inbuilt interlocks for Low & High temperature, Front and/or Back guards, Maximum Cycle
Time, Emergency stop.
Page 7 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Page 8 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Push this key to move cursor from left to right direction for parameter setting in any menu.
With help of this key you should toggle your screen from shot counter to proportional to
RPM counter to shot counter.
Page 9 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Injection Key
Push for activate of Injection action manually.
(Disable by any zone of barrel temperature is lower than alarm low setting)
Refill Key
Push for activate of Refill action manually.
(Disable by any zone of barrel temperature is lower than alarm low setting)
Page 10 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Core In Key
Push for activate of Core In action manually.
Core Out Key
Push for activate of Core Out action manually.
(H) PRECAUTIONS
To prevent damage from human and machine, please obey the
following safety caution.
Equipment must be operating under correct power. (Install a voltage stabilizer while need)
Earth terminal must be connected to qualified terminal.
All electrical elements with EARTH terminal, it is necessary for users to connect with the
EARTH terminal.
The high power cables should be separated from the low power cables to avoid interferes.
TO prevent fire or hazard shock, do not expose the unit to rain or moistly place.
Please understand the operating process before use.
When system shut down, wait 10seconds for re-start.
Thermocouples used for this system must be isolated (ungrounded) Fe/k type.
The wiring of each zone starting from thermocouple of heater must be verified.
For ex: first zone thermocouple must be connected to first channel of the system and heater
of first zone must be connected to heater 1of the system.
The limit switch and solenoids wiring must be done as per given wiring diagram.
If the proximity switches are used then use only NPN-NO type proximity switches.
Page 11 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Set Temperature
In case of operator level
Press SET TEMP. key.
First line of LCD shows TEMPERATURE C
Second line of LCD shows zone number & set temperature.
Select require zone using NEXT/ PREV key.
Set require temperature using INC, DEC and SHIFT key.
On pressing NEXT key the set value will be saved and display will show the next function.
List of temperature parameters are given below.
Message In
Zone Message In Default
Second Description Range Level
No. First Line Value
Line
1 Temperature C Zone 1 Zone 1 set temperature 0-500 C 200 C User
2 Temperature C Zone 2 Zone 2 set temperature 0-500 C 200 C User
3 Temperature C Zone 3 Zone 3 set temperature 0-500 C 200 C User
4 Temperature C Zone 4 Zone 4 set temperature 0-500 C 200 C User
5 Temperature C Zone 5 Zone 5 set temperature 0-500 C 200 C User
6 Temperature C Zone 6 Zone 6 set temperature 0-500 C 200 C User
7 Temperature C Zone 7 Zone 7 set temperature 0-500 C 200 C User
8 Temperature C Zone 8 Zone 8 set temperature 0-500 C 200 C User
Set Temperature
In case of Engineer level
Press SET TEMP key and keep it pressed for at least ten seconds.
First line of LCD shows parameter name.
Second line of LCD shows zone number & parameter value.
Select require parameter using NEXT/ PREV key.
Set require value using INC, DEC and SHIFT key.
On pressing NEXT key the set value will be saved and display will show the next function.
On pressing set temp key the zone number can be changed. Again pressing the NEXT key the
different parameter of the same zone can be checked.
List of temperature parameters are given below.
Message In
Message In Default
ZoneNo. Second Description Range Level
First Line Value
Line
Temperature C Zone 1 Set temperature 0-500 C 200 C Engineer
Prop. Band C Zone 1 Proportional band 0-100 C 030 C Engineer
Integr. Time Sec Zone 1 Integral time 0-999 Sec 900 Sec Engineer
Derivt. Time Sec Zone 1 Derivative time 0-999 Sec 000 Sec Engineer
1
Cycle Time Sec Zone 1 Cycle time 0-200 Sec 15 Sec Engineer
Alarm Low C Zone 1 Alarm low 0-200 C 025 C Engineer
Alarm High C Zone 1 Alarm High 0-999 C 025 C Engineer
Blower Point C Zone 1 Blower Operating Point 0-999C 000 C Engineer
Page 12 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Page 13 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Set Miscellaneous
Press set MISC key.
Third line of LCD show function’s name and it’s value/status.
Select require function using NEXT/ PREV key.
Set require value/ status using INC, DEC and SHIFT key.
On pressing NEXT key the set value will be saved and display will show the next function.
List of miscellaneous parameters are given below.
Default
No. Message Description Range Level
Value
1 Mold Safty Mold Safety Operation On/Off On / Off Off Supervisor
2 MCls Bost Mold Close Boost Option 0000-0003 0000 Supervisor
3 Lock Ton2 Locking Tonnage 2 On/Off On / Off Off User
4 Auto Carrg Auto Carriage On/Off On / Off Off Supervisor
5 Carr W Inj Carriage With Injection Function On / Off On Supervisor
6 Flow Inj Flow Injection Option On/Off On / Off Off Supervisor
7 Inj. Boost Injection Boost Option 0000-0002 0000 Supervisor
8 Refil Boost Refill Boost On/Off 0000-0002 0000 Supervisor
9 RPM Intlk RPM Interlock On/Off On / Off Off Supervisor
10 LoRPM Scrw Minimum RPM limit to operate screw 0-20 0000 Supervisor
11 PPR Screw Screw pulse per revolution 0-4 0001 Supervisor
12 Suckback Suck Back On/Off On / Off On Supervisor
13 Decomp On Decompression On/Off On / Off Off Supervisor
14 Ejct Prog Ejector Operating Program 0-2 0002 Supervisor
15 Ejct Shot Ejector Shot 0-5 0001 User
16 EjBak I/L Ejector backward interlock On/Off On / Off Off Supervisor
17 Core 1 On Core 1 On/Off On / Off Off Supervisor
18 Core 2 On Core 2 On/Off On / Off Off Supervisor
19 Cor In Pos Core In Position 0000-0002 0000 Supervisor
20 CorOut Pos Core Out Position 0000-0002 0000 Supervisor
21 Core 1 I/L Core 1 interlock On/Off On / Off Off Supervisor
22 Core 2 I/L Core 2 interlock On/Off On / Off Off Supervisor
23 Clamp Advnc Clamp advance On/Off On / Off Off Supervisor
24 Slide Slide On/Off On / Off Off Supervisor
25 % Heat Zn1 Set Temperature of % Heating Zone 1 0-100% 0000 User
26 % Zn1 CyTm Cycle time of % Heating Zone 1 0-100Sec 0000 User
27 % Heat Zn2 Set Temperature of % Heating Zone 2 0-100% 0000 User
28 % Zn2 CyTm Cycle time of % Heating Zone 2 0-100Sec 0000 User
29 Purge Mode Purge Mode On/Off On / Off Off Supervisor
30 TestIn/Out Test Mode On/Off On / Off Off Supervisor
31 Test Temp Test Temperature Mode On/Off On / Off Off Supervisor
32 Count Rst Reset the Shot Counter On / Off Off User
Page 14 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Set Timer
Press set TIMER key.
Third line of LCD show function’s name and it’s set value.
Select require function using NEXT/ PREV key.
Set require time using INC, DEC and SHIFT key.
On pressing NEXT key the set value will be saved and display will show the next function.
List of timer parameters are given below.
Default
No. Message Description Range Level
Value
1 Mold Close Mold slow close time 0-999.9 Sec 001.0 User
2 Mold Safty Mold safety time 0-999.9 Sec 002.0 User
3 Carr.Forwd Carriage Forward time 0-999.9 Sec 003.0 User
4 Pre-Inject Pre Injection time 0-999.9 Sec 001.0 User
5 Flow Inj Flow Injection time 0-999.9 Sec 001.0 User
6 Injct Dely Injection delay 0-999.9 Sec 001.0 User
7 Inject 1 Injection 1 time 0-999.9 Sec 001.0 User
8 Inject 2 Injection 2 time 0-999.9 Sec 001.0 User
9 Inject 3 Injection 3 time 0-999.9 Sec 001.0 User
10 Inject 4 Injection 4 time 0-999.9 Sec 001.0 User
11 Inject Hld Injection Hold time 0-999.9 Sec 001.0 User
12 Sukbk1 Dly Suck back 1 Delay 0-999.9 Sec 001.0 User
13 Sukbk1 Tim Suck back 1 Time 0-999.9 Sec 001.0 User
14 CarrBk Dly Carriage backward delay 0-999.9 Sec 003.0 User
15 Intens Dly Intensifier delay 0-999.9 Sec 001.0 User
16 Intens Tim Intensifier time 0-999.9 Sec 001.0 User
17 Air Cavity Air Cavity time 0-999.9 Sec 001.0 User
18 Refil Dely Refill delay 0-999.9 Sec 001.0 User
19 Refil Time Refill time 0-999.9 Sec 001.0 User
Page 15 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Set Pressure
Press set Pressure key.
Third line of LCD show function’s name and it’s set Pressure.
Select require function using NEXT/ PREV key.
Set require pressure using INC, DEC and SHIFT key.
On pressing NEXT key the set value will be saved and display will show the next function.
List of pressure parameters are given below.
Default
No. Message Description Range Level
Value
1 Mclos Slow Mold close slow (Open side) 0-100 bar 50bar User
2 Mclos Fast Mold close fast 0-100 bar 70bar User
3 Mclos Slo2 Mold close slow 2 (Close side) 0-100 bar 50bar User
4 Mold Safty Mold safety 0-100 bar 10bar Supervisor
5 Lokin Ton1 Locking Tonnage 1 0-100 bar 90bar User
6 Lokin Ton2 Locking Tonnage 2 0-100 bar 100bar User
7 Carr.Forwd Carriage Forward 0-100 bar 30bar User
8 Carr.Bakwd Carriage Backward 0-100 bar 30bar User
9 Pre-Inject Pre Injection 0-100 bar 30bar User
Page 16 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Set Flow
Press set Flow key.
Third line of LCD show function’s name and it’s set Flow.
Select require function using NEXT/ PREV key.
Set require flow using INC, DEC and SHIFT key.
On pressing NEXT key the set value will be saved and display will show the next function.
List of flow parameters are given below.
Default
No. Message Description Range Level
Value
1 Mclos Slow Mold close slow (Open side) 0-100 % 50% User
2 Mclos Fast Mold close fast 0-100 % 70% User
3 Mclos Slo2 Mold close slow 2 (Close side) 0-100 % 50% User
4 Mold Safty Mold safety 0-100 % 10% Supervisor
5 Lokin Ton1 Locking Tonnage 1 0-100 % 90% User
6 Lokin Ton2 Locking Tonnage 2 0-100 % 100% User
7 Carr.Forwd Carriage Forward 0-100 % 30% User
8 Carr.Bakwd Carriage Backward 0-100 % 30% User
9 Pre-Inject Pre Injection 0-100 % 30% User
10 Inject 1 Injection 1 0-100 % 30% User
11 Inject 2 Injection 2 0-100 % 30% User
12 Inject 3 Injection 3 0-100 % 30% User
13 Inject 4 Injection 4 0-100 % 30% User
14 Inject Hld Injection Hold On 0-100 % 50% User
Page 17 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Page 18 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
This mode can be enabled by making Test Temp. in set misc. menu ON.
The zone under testing can be changed using INC or DEC key.
To disable the test TEMP. mode made off the Test TEMP. in set misc menu.
(6) AUTO:
On pressing AUTO key the auto cycle starts.
Here after completion of one cycle, cycle delay timer starts after completion of cycle delay
cycle restarts.
Page 19 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
(L) INTERLOCKS
It is a one type of alarm system which activate when cycle or any other function does not
operate properly because of those abnormal condition it indicate INTERLOCK
Page 20 of 27
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
Wiring Diagram
0V 24V
24V AC
INPUT
Page 21 of 27
DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL
INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT
CARDN0. CARDN0. CARDN0. CARDN0. CARDN0. CARDN0. CARDN0. CARDN0.
L9 L9 L9 L9 L9 L9 L9 L9
LS 1
LS 3
LS 5
LS 7
LS 33
LS 35
LS 37
LS 39
LS 25
LS 27
LS 29
LS 30
LS 57
LS 59
LS 61
LS 63
LS 9
LS 11
LS 13
LS 15
LS 17
LS 19
LS 21
LS 23
LS 41
LS 43
LS 45
LS 47
LS 49
LS 51
LS 53
LS 55
IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND
LS 2
LS 4
LS 6
LS 8
LS 34
LS 36
LS 38
LS 40
LS 10
LS 12
LS 14
LS 16
LS 18
LS 20
LS 22
LS 24
LS 26
LS 28
LS 30
LS 32
LS 42
LS 44
LS 46
LS 48
LS 50
LS 52
LS 54
LS 56
LS 58
LS 60
LS 62
LS 64
Page 22 of 27
INJkon 00/1.0/ Manual
STREAMLINE CONTROLS PVT. LTD
DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL DIGITAL
INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT
CARDN0. CARDN0. CARDN0. CARDN0. CARDN0. CARDN0. CARDN0. CARDN0.
L9 L9 L9 L9 L9 L9 L9 L9
LS 1
LS 3
LS 5
LS 7
LS 33
LS 35
LS 37
LS 39
LS 25
LS 27
LS 29
LS 30
LS 57
LS 59
LS 61
LS 63
LS 9
LS 11
LS 13
LS 15
LS 41
LS 43
LS 45
LS 47
LS 17
LS 19
LS 21
LS 23
LS 49
LS 51
LS 53
LS 55
IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V IN 1IN 3IN 5IN 7 +24V
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
PNP/NPN
IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND IN 2IN 4IN 6IN 8 GND
LS 2
LS 4
LS 6
LS 8
LS 34
LS 36
LS 38
LS 40
LS 10
LS 12
LS 14
LS 16
LS 26
LS 28
LS 30
LS 32
LS 42
LS 44
LS 46
LS 48
LS 58
LS 60
LS 62
LS 64
LS 18
LS 20
LS 22
LS 24
LS 50
LS 52
LS 54
LS 56
Page 23 of 27
INJkon 00/1.0/ Manual
STREAMLINE CONTROLS PVT. LTD
P-OUT P-OUT P-OUT P-OUT P-OUT P-OUT P-OUT P-OUT
AN ALOG A NA LOG AN A LOG A NALOG A NA LOG AN A LOG A N ALOG A NA LOG
AC INPUT OUTPUT OU T AC INPUT OUTPUT OU T AC INPUT OUTPUT O UT AC INPUT OUTPUT OU T AC INPUT OUTPUT OU T AC INPUT OUTPUT O UT AC INPUT OUTPUT OU T AC INPUT OUTPUT OUT
AC IN AC IN COIL C OIL A-OUT AC IN A C IN COIL COIL A-OUT AC IN AC IN COIL C OIL A-OUT A C IN A C IN C OIL COIL A-OUT AC IN A C IN COIL COIL A-OUT A C IN AC IN C OIL C OIL A-OUT A C IN A C IN C OIL COIL A-OUT AC IN A C IN COIL COIL A-OUT
A C IN
A C IN
A C IN
A C IN
A C IN
A C IN
A C IN
A C IN
A A A A A A A A
Maximum 35VAC/DC COIL 10VDC/50mA Maximum 35VAC/DC COIL 10VDC/50mA Maximum 35VAC/DC COIL 10VDC/50mA Maximum 35VAC/DC COIL 10VDC/50mA Maximum 35VAC/DC COIL 10VDC/50mA Maximum 35VAC/DC 10VDC/50mA Maximum 35VAC/DC COIL 10VDC/50mA Maximum 35VAC/DC COIL 10VDC/50mA
COIL
Input From Transformer Analog Output Input From Transformer Analog Output Input From Transformer Analog Output Input From Transformer Analog Output Input From Transformer Analog Output Input From Transformer Analog Output Input From Transformer Analog Output Input From Transformer Analog Output
or SMPS Maximum or SMPS Maximum or SMPS Maximum or SMPS Maximum or SMPS Maximum or SMPS Maximum or SMPS Maximum or SMPS Maximum
Page 24 of 27
INJkon 00/1.0/ Manual
STREAMLINE CONTROLS PVT. LTD
Page 25 of 27
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
SSR (230VAC)OUTPUT MODULE
0-230VAC IN
From Transformer
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
SSR (230VAC)OUTPUT MODULE
0-230VAC IN
From Transformer
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
SSR (230VAC)OUTPUT MODULE
0-230VAC IN
From Transformer
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
SSR (230VAC)OUTPUT MODULE
0-230VAC IN
From Transformer
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
SSR (230VAC)OUTPUT MODULE
0-230VAC IN
From Transformer
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
SSR (230VAC)OUTPUT MODULE
0-230VAC IN
From Transformer
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
SSR (230VAC)OUTPUT MODULE
0-230VAC IN
From Transformer
OUTPUT-1
OUTPUT-2
OUTPUT-3
OUTPUT-4
CARDN0.
OUTPUT-5
OUTPUT-6
OUTPUT-7
OUTPUT-8
LIVE
NEUTRAL
0-230VAC IN
From Transformer
INJkon 00/1.0/ Manual
STREAMLINE CONTROLS PVT. LTD
Junction Card(ML-538A)
From MMI
To Analog Input
Module
To Input Module
Page 26 of 27
INJkon 00/1.0/ Manual
STREAMLINE CONTROLS PVT. LTD
STREAMLINE CONTROLS PVT. LTD
INJkon 00/1.0/ Manual
O
OUUR
RPPR
ROOD
DUUC
CTTR
RAAN
NGGE
E
• DC Stepper Drives
• Profile Generator
Page 27 of 27