DATA SHEET OF 3 PHASE INDUCTION MOTOR


Customer : Spares 4U Enquiry / INDENT NO : QNMXD90087/1000 (Dated: 02/09/2019)

Frame ND280S Rated Output (kW) 55


Voltage (V) 415 +-10% Rated Current (A) 97.00
Rated Speed (RPM) 1480 No of poles 4
Frequency (Hz) 50 +-5% Duty S1
Method of Cooling IC411 Degree of Protection IP55
Gas Group Not applicable Mounting B3
Temp Class NO
Enclosure TEFC Safe Area

Load 100% Load 75% Load 50% Load


Efficiency IE2 - 93.5 % 93.5 % 93 %
Power factor 0.84 0.79 0.72
AMB. Temp/Temp rise 50°C/70°C (By Resistance Method)
Insulation class F (Temp. rise limited to class ‘B’)
Rated Torque (kg-m) 36.20
Locked rotor current % FLC 700
Starting torque % FLT 225
Pull out torque % FLT 275

Method of starting Variable Voltage / Frequency


Winding connections Delta
No of terminals 6
Direction of rotation Bidirectional

Motor GD Sq. (kg-m²) 6.28


Load GD Sq. (kg-m²) 6.28
Starting time @100% V (Sec) 0.9
Locked rotor Withstand time hot (Sec.) 15
Locked rotor Withstand time cold (Sec.) 30
Stator Thermal / Cooling time constant 60 / 120
(min)
Terminal box position RHS From DE
Cable size 2 * 3C,95-MM²
Bearing DE/ODE 6318-C3 / 6318-C3-I
Type of lubrication Unirex-N3
Shaft Material EN8 OR C40 Stator Body Material Cast Iron

Net Weight (Approx.) kg 600


Paint shade RAL7034
Applicable standards IS:1231,IS:12075,IS:12065,IS:325,
Space heaters SPACE HEATER 60WX2 (CE280/315) Voltage: 220-240V
Accessories Rod Type Btd Reqd(1/Brg),Insulated Bearing At Nde,3Wire Type Rtd
Pt100-3Nos Reqd,

Customer specific requirement if any:

All performance data is subject to tolerance as per IEC 60034


All performance shall be measured on sinusoidal supply
Temp rise test shall be carried at rated kW & voltage for 1 hour other than S1 duty
Max 5 % THD allowed for voltage and Temperature rise is limited to class F, unless otherwise specified
Inverter driven motors, voltage spikes are allowed maximum 1600 V
with min. rise time of 0.1 microsecond, cable size to be selected accordingly.
Customer specific paint shade and paint thickness will not be applicable on powder coated components.
Issued By : Vinoth Kumar M
Date : 02/11/2019 LT Motors Division, Ahmadnagar

Page 1 of 1