Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Generators: Model: PDG35 35 KVA Available in Single Phase and Three Phase

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

GENERATORS Specifications

Model: PDG35 Model PDG35


Alternator
Make & Model Powercity TWG-224D
35 KVA Frequency Hz 50 60
Output Rating Prime 30 35
Available in Single Phase and Three Phase (KVA) Standby 32 37.5
Phase 1-Phase (2 Wires) or 3-Phase (4 Wires)
Rated Voltage V 200-240 / 380-440
Power Factor 0.8 (Lagging)
Voltage
% Within +/- 1.5
Regulation
Brushless rotating exciter
Excitation with Automatic Voltage
Regulator (AVR)
Insulation Class H
Engine
4JB1T
Make & Model
(Isuzu Technology)
Vertical inline; water
Powercity generators are designed in conformance Type cooled; 4 stroke; direct
with European Standards certified by independent injected; turbocharged
Output Rating Kw/rpm 28/1500 34/1800
certifying agency the Materials Industrial Research No. of cylinders-
mm 4 – 93 X 102
and Technology Center (MIRTEC) with certificate Bore X Stroke
number MC/TH-C-269/08. The principles in design, Piston
L 2.771
Displacement
safety, rating and performance are in accordance
Fuel ASTM No. 2 Diesel
with European Standards EN 12601:2001, EN 60204- Fuel
1:2006, EN 60034-1:2004, EN ISO 12100-1:2003 and Consumption @ L/h 6.5 7.5
EN ISO 12100-2:2003. Generators are designed and 75% Load
Lube Oil
built to provide electrical power for stand-by or Capacity
L 6
continuous use. Comes with 2 years or 2,000 run Coolant
L 15
hours limited warranty whichever comes first. Capacity
Battery Capacity V-Ah 12V-80Ah
Features: Fuel Tank
L 80
Capacity
 MANUAL or AUTOMATIC starting and Unit
stopping capability. Length mm 1850
Dimensions Width mm 800
 Digital controller. Height mm 1000
 Direct injection diesel engine for fuel Dry Weight Kg 920
efficiency. Sound Level
 Brushless rotating field generator with class dB @ 7 m 66 68

H insulation.
 NEMA 3R enclosure suitable for outdoor use. Note: Due to continuous product improvement, the generator
set manufacturer reserves the right to change the design or
 Integral vibration isolators.
specifications without notice and without any obligation or
 Silent type generator. liability whatsoever.
twelve hours. Ratings in accordance with ISO 8528-1, overload
power in accordance with ISO 3046-1, BS 5514, AS 2789, and
Engine: DIN 6271.

4JB1T – 4 cylinder Direct Injection Diesel; Turbocharged GENERAL GUIDELINES FOR DERATION:
(Isuzu Technology)
Altitude: Derate 0.5% per 100 meter (328 ft.) elevation above
1000 meter (3279 ft.).
28kW@1500 rpm / 34kW@1800 rpm
Temperature: Derate 1.0% per 10°C (18°F) temperature above
40°C (104°F).

FUEL: Use clean diesel fuel only. Diesel fuel quality should
meet the specifications of ASTM D975 and the Worldwide Fuel
Charter.

SOUND LEVEL: Sound level is measured in free field


environment (acoustic test chamber) where sound may
propagate free from any form of obstruction.

dB Range:

Quiet Normal Alarm clock


Room conversation City traffic Chainsaw

40 50 60 70 80 90 100
Standards:
Moderate Vacuum Motorcycle
EN 12601:2001 – Reciprocating internal combustion rainfall cleaner Hair dryer
engine driven generating sets – Safety.
PDG35
EN 60204-1:2006 – Safety of machinery; electrical
equipment of machines – General requirements.
Quality Assurance:
EN 60034-1:2004 – Rotating electrical machines –
Rating and performance.
EN ISO 12100-1:2003 – Safety of machinery; basic
concepts and general principles for design Part 1.
EN ISO 12100-2:2003 – Safety of machinery; basic ISO 9001:2008
concepts and general principles for design Part 2. Certificate No. U13Q2GZ682452F1M

Applicable EGSA* Standards.


Manufactured by:
*- Electrical Generating Systems Association Powercity Electromechanical & Equipment Co Ltd
Fujian, China
Application Notes:
Distributed in the Philippines by:
STANDBY RATING: Standby ratings apply to installations served
Powercity Corporation
by a reliable utility source. This rating is applicable to varying
Km. 20, East Service Road, Muntinlupa City
loads for the duration of a power outage. There is no overload
Metro Manila, Philippines
capability for this rating. Ratings are in accordance with ISO
Tel. (+632) 869 1991, (+632) 8697520
3046-1, BS 5514, AS 2789 and DIN 6271.
Fax. (+632) 8693869
PRIME POWER RATING: Prime power ratings apply to Email: contactus@powercity.ph
installations where utility power is unavailable or unreliable.
At varying load the number of generator set operating hours is Made in China
unlimited. A 10% overload capacity is available for one hour in