Operators Manual For Sea Tel Dac-2302 Antenna Control Unit
Operators Manual For Sea Tel Dac-2302 Antenna Control Unit
Sea Tel Marine Stabilized Antenna systems are manufactured in the United States of America.
R&TTE The Sea Tel DAC-2202, or DAC-2302, Antenna Control Unit used with the Sea Tel Antenna
complies with the requirements for Radio and Telecommunication Terminal Equipment. A
copy of the R&TTE Declaration of Conformity for this equipment is contained in the Antenna
CE Manual for your system.
The Sea Tel DAC-2202, or DAC-2302, Antenna Control Unit contains FCC compliant supervisory software to
continuously monitor the pedestal pointing accuracy and use it to control the “Transmit Mute” function of the
satellite modem to satisfy the provisions of FCC 47 C.F.R. § 25.222(a)(l)(iii). A copy of the FCC Declaration of
Conformity for this equipment is contained in the Antenna Manual for your system.
Copyright Notice
All Rights Reserved. The information contained in this document is proprietary to Sea Tel, Inc.. This document
may not be reproduced or distributed in any form without prior consent of Sea Tel, Inc. The information in
this document is subject to change without notice. Copyright © 2010 Sea Tel, Inc is doing business as
Cobham SATCOM.
This document has been registered with the U.S. Copyright Office.
Revision History
ii
Table of Contents DAC2302 Operator Manual
iii
DAC2302 Operator Manual Table of Contents
iv
Quick Start Operation – Introduction DAC2302 Operator Manual
1-1
DAC2302 Operator Manual Quick Start Operation – Introduction
1-2
Quick Start Operation – Introduction DAC2302 Operator Manual
Status LED’s
1-3
DAC2302 Operator Manual Quick Start Operation – Introduction
1-4
Operation DAC2302 Operator Manual
2. Operation
2-1
DAC2302 Operator Manual Operation
2-2
Operation DAC2302 Operator Manual
2-3
DAC2302 Operator Manual Operation
2-4
Operation DAC2302 Operator Manual
2-5
DAC2302 Operator Manual Operation
2-6
Operation DAC2302 Operator Manual
2-7
DAC2302 Operator Manual Operation
2-8
Operation DAC2302 Operator Manual
2-9
DAC2302 Operator Manual Operation
2-10
Operation DAC2302 Operator Manual
2-12
Operation DAC2302 Operator Manual
SAT REF mode – may be ON if you are experiencing frequent, or constant, gyro read errors (error
code 0001). Must be ON if you are using NMEA Gyro input.
Target the desired satellite longitude value but include an odd tenths digit (ie if you desired to target inclined
satellite 186.0 W you would key in SAT 186.1 W for the ACU to do an inclined search). The Antenna Control
Unit calculates the Azimuth, Elevation and Polarization values it will use to target the antenna.
Initially the antenna will go to a calculated position that is half of SWEEP INCR degrees above, and
perpendicular to, the satellite arc (along the same angle as polarization for the desired satellite). This position
is the “Start” of the search pattern in the graphic above. Then the antenna will drive down along the
polarization angle SWEEP INCR degrees, step one Search Increment to the right (parallel to the satellite arc),
search up along the polarization angle SWEEP INCR degrees, step two Search Increments to the left, search
down, etc expanding out in the search pattern until Search Limit is reached. When the end of the search
pattern is reached, the ACU will retarget the antenna to the calculated Azimuth and Elevation point.
If the desired signal is found (AND network lock is achieved in the satellite modem) at this position, or
anywhere within the search pattern, the ACU will terminate search and go into Tracking mode. If the desired
signal is not found the ACU will wait SEARCH DELAY, then target the antenna to start point shown in the
graphic above and begin the search pattern again. This cycle will repeat until the desired satellite signal is
found or the operator intervenes.
2-13
DAC2302 Operator Manual Operation
2-14
Setup – CommIF and HTML Pages DAC2302 Operator Manual
3-1
DAC2302 Operator Manual Setup – CommIF and HTML Pages
(Typed characters will not display unless “Echo” is [Gnnn.nnn.nnn.nnn↵ Set Gateway address
turned on in the Comm Port Properties.)
[0nnnn↵ Set TCP/IP-0 (Port 0) port number
[1nnnn↵ Set TCP/IP-1 (Port 1) port number
[Unnnn↵ Set UDP (Software Upload) port number
[Cnnnn↵ Set M&C (Port C) baud rate
[Bnnnn↵ Set NMEA B (Port B) baud rate
[Annnn↵ Set NMEA A (Port A) baud rate
[?↵ View Settings IP, NM, GW, Port 0,1, baud C, B, A
[V↵ View Comm IF PCB Software Version
[L↵ Lock out ports for download
IP is the ACU IP address
(Factory Default 192.168.30.195)
NM is the ACU Subnet Mask
(Factory Default 255.255.255.0)
GW is the ACU Gateway
(Factory Default 192.168.30.1)
TCP 0 is the first of two available TCP/IP Port’s
(Factory Default 2000)
TCP 1 is second of two available TCP/IP Port’s
(Factory Default is 2001)
UDP is the Comm IF PCB Software Upload port
(Factory Default 3000)
M&C (C) is the M&C RS232 Port C (J3) Baud Rate
(Factory Default 9600)
NMEA B is the NMEA RS232 Port B (J2) Baud Rate
(Factory Default 4800)
NMEA A is the NMEA RS232 Port A (J2)Baud Rate
(Factory Default 4800)
3-2
Setup – CommIF and HTML Pages DAC2302 Operator Manual
3-3
DAC2302 Operator Manual Setup – CommIF and HTML Pages
The System Information page, also known as the HOME page, displays current antenna software and model
configurations.
Number Description
1 Click to select to the Port Settings Page. This page displays the TCP connection and baud rate
settings for the Comm If Module.
2 Click to select to the DAC Parameters 1 Page. This page displays the current ACU configuration
parameter values stored in the ACU.
3 Click to select to the DAC Parameters 2 Page. This page displays the current Satellite Tracking
parameter values stored in the ACU. This page also contains the currently defined blockage zones (Az
Limits 1-6).
4 Click to select to the Favorites Page. This page displays an editable list of 5 “Preset” satellites and
their respective tracking parameters.
5 Click to select to the Status page. This page displays current system status, including Tracking
condition, Antenna Position, Vessel Location / Orientation, and decoded error conditions.
6 The ACU Model field displays the software version currently installed in the ACU M/B.
7 Click to refresh the field values described below, while on any other page, the Home link redirects you
to this page.
8 The PCU Model field displays the Antenna model configuration and the software version currently
installed in the PCU.
9 The Comm Interface field displays the software version currently installed onto the Comm IF
Module.
10 The Tracking Receiver field displays the software version currently installed onto the ACU’s internal
tracking receiver.
The Serial Number display fields are NOT being used in this software revision.
3-4
Setup – CommIF and HTML Pages DAC2302 Operator Manual
Number Description
1 The IP Address field displays the Static Internet Protocol address value currently stored in the
Comm IF module (Flash). To change the IP address to match an existing LAN info structure, type
in the desired value and click on the SUBMIT button. If the parameter change causes desirable
operation click on the SAVE button to store value to memory. This address must conform to the
nnn.nnn.nnn.nnn format where nnn is a number between 0 and 255.
2 The Net Mask field displays the Subnet Mask address value currently stored in the Comm IF
module. To change the Subnet to match an existing LAN info structure, type in the desired value
and click on the SUBMIT button. If the parameter change causes desirable operation click on the
SAVE button to store value to Flash. This address must conform to the nnn.nnn.nnn.nnn format
where nnn is a number between 0 and 255.
3 The Gateway field displays the Static Gateway Internet Protocol address value currently stored in
the Comm IF module. To change the Gateway IP address to match an existing LAN info structure,
type in the desired value and click on the SUBMIT button. If the parameter change causes
desirable operation click on the SAVE button to store value to Flash. This address must conform
to the nnn.nnn.nnn.nnn format where nnn is a number between 0 and 255.
4 The TCP Port 0 field displays the Transmission Control Protocol Port 0 value currently stored in
the Comm IF Module. To change the Port value to match an existing LAN info structure, type in
the desired value and click on the SUBMIT button. If the parameter change causes desirable
operation click on the SAVE button to store value to Flash. This address must conform to the
nnnn format where nnnn is a number between 0 and 65535.
5 The TCP Port 1 field displays the Transmission Control Protocol Port 1 value currently stored in
the Comm IF Module. To change the Port value to match an existing LAN info structure, type in
the desired value and click on the SUBMIT button. If the parameter change causes desirable
operation click on the SAVE button to store value to Flash. This address must conform to the
nnnn format where nnnn is a number between 0 and 65535.
6 The OpenAMIP Port field displays the Open Antenna-Modem Interface Protocol port value.
This port is specifically used to communicate with an “Open AMIP” compatible satellite modem
and should not be changed from the factory default.
7 The UDP Port displays the User Datagram Protocol Port value stored in the Comm IF Module.
This port is specifically used to perform software upgrades to the Comm IF Module and should
NOT be changed.
3-5
DAC2302 Operator Manual Setup – CommIF and HTML Pages
8 The M&C Baudrate field displays the J3 M&C Port Baud rate value currently stored in the Comm
IF Module. To change the Baud rate, type in the desired value and click on the SUBMIT button or
click on the SAVE button to store value to Flash. Acceptable baud rate values are 4800 or 9600.
9 The NMEA A Baudrate field displays the J2 NMEA Port A Baud rate value currently stored in the
Comm IF Module. To change the Baud rate, type in the desired value and click on the SUBMIT
button or click on the SAVE button to store value to Flash. Acceptable baud rate values are 4800
or 9600.
10 The NMEA B Baudrate field displays the J2 NMEA Port B Baud rate value currently stored in the
Comm IF Module. To change the Baud rate, type in the desired value and click on the SUBMIT
button or click on the SAVE button to store value to Flash. Acceptable baud rate values are 4800
or 9600.
11 The LO Band 1 field displays a drop down selection list for the Local Oscillator value to be used
when Band 1 is selected for tracking purposes.
12 The LO Band 2 field displays a drop down selection list for the Local Oscillator value to
be used when Band 2 is selected for tracking purposes.
13 The LO Band 3 field displays a drop down selection list for the Local Oscillator value to
be used when Band 3 is selected for tracking purposes.
14 The LO Band 4 field displays a drop down selection list for the Local Oscillator value to
be used when Band 4 is selected for tracking purposes.
15 The NMEA Heading ID displays a drop down selection list for NMEA 0183 compliant heading
inputs into the ACU.
Current selections available are HDT, HDM, HDD, & HDG.
16 Click the SUBMIT button to transfer all currently displayed parameters to the Comm IF module
operating software variables table. NOTE: The submit button will not store the values to NVRAM;
an ACU reset or power cycle will revert to the settings saved in memory.
17 Click the SAVE button to store all current parameters in the operating software variables table to
Flash (Comm IF).
**THIS DOES NOT SAVE DISPLAYED PARAMETERS UNLESS THE SUBMIT BUTTON IS PRESSED
FIRST**
18 The Command field displays an entry field for line based utility or configuration commands.
Enter in the desired command string and then select the Send button to submit the command.
For a complete list of available commands, refer to your antenna manual or the appropriate
command set documentation
19 The Response field displays a display value or string based, whenever a sent remote command
involves a displayed response.
3-6
Setup – CommIF and HTML Pages DAC2302 Operator Manual
Number Description
To change a parameter value mouse click inside the entry field and type in the desired value or
select from the drop down list and click on the SUBMIT button. If the parameter value
change(s) causes desirable operation click on the SAVE button to store into Flash.
1 The Elevation Trim field displays the numeric value currently set in RAM.
2 The Elevation Step Size field displays the numeric value currently set in RAM.
3 The AUTO Threshold field displays the numeric value currently set in RAM.
4 The Search Increment field displays the numeric value currently set in RAM.
5 The Search Limit field displays the numeric value currently set in RAM.
6 The Search delay field displays the numeric value currently set in RAM.
7 The System Type field displays the sum of the numeric values currently set in RAM. This List
box below the displayed parameter displays the decoded System Type parameter currently
stored in Flash. The applicable ACU system options are highlighted in blue, when the System
Type value is entered.
Changes to this list box itself is possible, Select the desired options and the correlating
parameter value for System Type will be displayed in the entry field.
8 The Tracking Display dropdown menu list displays the value currently set in RAM.
9 The Azimuth Trim field displays the numeric value currently set in RAM.
10 The Azimuth Step Size field displays the numeric value currently set in RAM.
11 The Sweep Increment field displays the numeric value currently set in RAM.
12 The Step Integral field displays the numeric value currently set in RAM.
13 The Polang Type field displays the numeric value currently set in RAM.
14 The Polang Offset 24V field displays the numeric value currently set in RAM.
15 The Polang Scale 24V field displays the numeric value currently set in RAM.
3-7
DAC2302 Operator Manual Setup – CommIF and HTML Pages
16 The Gyro Type field displays the numeric value currently set in RAM. Select the desired Gyro
Interface from the drop down menu selection list and the correlating parameter value for Gyro
Type will be displayed in the entry field
17 Click the SUBMIT button to transfer all currently displayed parameters to the operating
software variables table (working memory). NOTE: The submit button will not store the values
to memory; an ACU reset or power cycle will revert to the old settings saved in NVRAM.
18 Click the “RELOAD” button to refresh the screen to the current ACU parameter values
19 Click the SAVE button to store all currently displayed parameters to Flash (68HC08).
Number Description
1 The SATELLITE field(s) present longitudinal position of the currently stored (or last targeted)
satellite.
2 The Frequency MHZ field displays the numeric value currently stored in RAM.
3 The Baudrate field displays the numeric value currently stored in RAM.
4 The FEC field displays the selected value currently stored in RAM.
5 The Tone field displays the selected state currently stored in RAM.
6 The VOLT field displays the selected value currently stored in RAM.
7 The Target NID field displays the hexadecimal value currently stored in RAM.
8 The Band field displays the selected value currently stored in RAM.
9 The Tx Polarity field displays the selected value currently stored in RAM.
10 The Sat Skew field displays the numeric value currently stored in RAM.
11 The Az Limit 1 field displays the numeric value currently stored in RAM.
12 The Az Limit 2 field displays the numeric value currently stored in RAM.
13 The Az Limit 3 field displays the numeric value currently stored in RAM.
3-8
Setup – CommIF and HTML Pages DAC2302 Operator Manual
14 The Az Limit 4 field displays the numeric value currently stored in RAM.
15 The Az Limit 5 field displays the numeric value currently stored in RAM.
16 The Az Limit 6 field displays the numeric value currently stored in RAM.
17 The EL Limit 12 field displays the numeric value currently stored in RAM.
18 The EL Limit 34 field displays the numeric value currently stored in RAM.
19 The EL Limit 56 field displays the numeric value currently stored in RAM.
20 Click the SUBMIT button to transfer all currently displayed parameters to the operating
software variables table (working memory). NOTE: The submit button will not store the values
to memory, an ACU reset or Power cycle will revert to the old settings saved in NVRAM.
21 Click the RELOAD button to refresh the screen to display the current ACU parameter values
22 Click the SAVE button to store all currently displayed parameters to memory (NVRAM).
Number Description
1 These fields present the current antenna status as reported by the ACU.
2 These fields present the current DishScan and Satellite Reference mode status as reported by
the ACU and PCU.
3 The Control field buttons allow the user to Toggle the antennas’ current tracking condition or
to clear any reported errors as reported in fields 16 and 17.
4 The Latitude field displays the numeric and hemispheric value currently stored in RAM.
5 The Longitude field displays the numeric and hemispheric value currently stored in RAM.
6 The SATELLITE field(s) present longitudinal and hemispheric position of the currently stored
(or last targeted) satellite.
7 The Local HDG field displays the numeric value currently stored in RAM. (Gyro compass input
to ACU)
8 The Threshold field displays the numeric value currently reported by the ACU.
9 The Mdm Lck/Ext AGC field displays the numeric value currently reported by the ACU.
3-9
DAC2302 Operator Manual Setup – CommIF and HTML Pages
10 The Azimuth field displays the Antenna’s True North Azimuth pointing angle.
11 The Elevation field displays the Antenna’s Elevation pointing angle referenced to the horizon.
12 The Relative AZ field displays the Antenna’s Azimuth pointing angle referenced to the vessels
bow marker.
13 The Remote field displays the numeric value currently reported by the PCU. (Azimuth
Stabilization Loop’s Heading Registry)
14 The AGC field displays the numeric value currently reported by the ACU.
15 The Remote POL field displays the numeric value currently reported by the PCU.
16 The PCU Errors box is a read only field that displays Pedestal reported errors currently
triggered.
17 The ACU Errors box is a read only field that displays the decoded ACU reported errors
currently triggered.
18 The Refresh field allows the user to adjust the page refresh settings, AUTO is selected by
default, which refreshes the displayed page every 5 seconds
Number Description
1 These NAME fields present the current satellite preset name for each respective Favorite
Satellite Column. You may not use the ‘ (apostrophe) character in the name field
2 The SAT Lon fields present the longitudinal satellite position for each respective Favorite
Satellite Column.
3 The Frequency fields present the IF tracking parameter value for each respective Favorite
Satellite Column.
4 The Baud Rate fields present the Baud /Symbol Rate for each respective Favorite Satellite
Column.
3-10
Setup – CommIF and HTML Pages DAC2302 Operator Manual
5 The FEC fields present the Forward Error Correction Rate for each respective Favorite Satellite
Column.
6 The Tone fields present the 22Khz Tone State for each respective Favorite Satellite Column.
7 The Volt fields present the BDE voltage state for each respective Favorite Satellite Column.
8 The Target NID fields present the Hexadecimal Network Identification value for each
respective Favorite Satellite Column.
9 The Band fields present a drop down listing of the available LNB Band selection for each
respective Favorite Satellite Column.
10 The Tx Pol fields present the transmit for each respective Favorite Satellite Column.
11 The Sat Skew fields present the satellite Polarization Offset value for each respective Favorite
Satellite Column.
12 Click on the Select button to submit the respective Favorite Satellite Column parameters into
RAM
13 Click on the Save button to submit the respective Favorite Satellite Column parameters to
Flash.
3-11
DAC2302 Operator Manual Setup – CommIF and HTML Pages
3-12