INTRODUCTION
Pre-Coalesce:
A borosilicate or other type of element designed to
restrict and collect tiny aerosol contaminants,
primarily oil and other contaminants, which may
prove detrimental to the successful operation of any
form of desiccant.
Desiccant Tower
The desiccant beads, which extract the moisture
from the air, are housed in two towers. These are
also called desiccant towers.
Pressure Switch
An integral pressure sensing device is located
internally to control the air drying cycle. The air dryer
cycles only when the predetermined pressure is
reached.
PURGE VALVE
There is one purge valve located at the bottom of each
desiccant tower. Alternatively, there is a common purge
valve connected to both desiccant towers. Purge valve
allows the regenerative air to discharge moisture
through the desiccant tower to atmosphere.
SYSTEM COMPONENTS OF AIR DRYER
HUMIDITY INDICATOR
FINAL FILTER
• KNORR BREMSE
• PCB FAILURE,
• AIR LEAKAGE FROM DUPLEX PISTON VALVE – VALVE
HEAD
• LOW PRESSURE LEAKAGE DUE TO MAL- OPERATION
OF PRE CONTROL VALVE (DUST)
Purge Valve Spring
Piston Assembly Fitted with
Valve Head & Spring
FAILURES OF FTIL AIR DRYER
• PCB FAILURE,
• AIR LEAKAGE FROM TOWER,
• PURGE VALVE SEAT DAMAGE
• DESICCANT FAILURE
• S.S. PIPE CONE & ‘T’ JOINT BROKEN
ACTION TAKEN BY FTIL
• DEVELOPED MODIFIED PCB WITH AUTO ISOLATION AND TO
WITHSTAND HIGHER SPIKE ENERGY LEVEL. TRIALS AT ELS,
LALLAGUDA & ITARSI ARE UNDER PROGRESS
• DESICCANT FAILURE – PROBLEM WITH ONE BATCH OF SUPPLY
• VALVE SEAT DAMAGE – UNDER INVESTIGATION.
OPERATION OF AIR DRYER
Compressed air after main reservoir MR-2 passes through a pre-coalesce filter (2). This removes
significant amount of debris, moisture and oil from the compressed air. After pre-coalesce filter
air enters into the ACTUATOR (3), which decides the entry of air to either of two DESICCANT
TOWERS (4A & 4B). Position of actuator is controlled by TIMER UNIT (5).
For example, in a particular cycle, wet air enters from the bottom of the tower (4a) and
passes through desiccant bed where moisture is adsorbed by the desiccant. Dry air with dew
point less than ambient temperature comes out from the top and finally goes out of dryer to
final filter (6). Final filter removes traces of desiccant powder, if any, from the dry air and air
then goes to main reservoir-2(MR-3 in case of electric loco).
A small part of the dry air (10-20% of inlet air capacity) is drawn from the dry air outlet of
tower (4a) and is passed through regenerative orifice of non-return valve (8) and on to the
desiccant bed of the other tower (4b). It removes the moisture collected in the second tower
and thus reactivates the desiccant. The moisture laden air is vented through exhaust valve
which is also called PURGE VALVE (9). Thus in this cycle tower (4a) works as dehydrating tower
and tower (4b) works as regenerative tower.
After completion of this cycle the working of two towers reverses and now the tower (4a)
works as REGENERATIVE TOWER and tower (4b) works as DEHYDRATING TOWER. In this way
two towers alternatively work as dehydrating/regenerative towers. This reversal takes place
after a predetermined time period. This is called CYCLE TIME OF THE AIR DRYER. Cycle time of
air dryer is normally 1 to 2 minutes.
OPERATION OF AIR DRYER
PNEUMATIC AND ELECTRICAL CONNECTIONS ON ELECTRIC LOCO
INSPECTION SCHEDULES OF AIR DRYER ON ELECTRIC LOCO
TRIP INSPECTION
1. Open drain cock of final filter to drain off any accumulated water content
2. Check the colour of humidity indicator It indicates condition of air after passing
through air dryer. Indication of various colour are as under.
• Blue colour ---- Dryer is performing correctly
• Lavender ---- Dryer is suspect - Verify dryer is cycling. - If dryer is cycling correctly and
auto drain valve of main reservoir No.1 is operating correctly, release the loco for
service
• White ---- Possible damaged dryer
- Verify dryer is cycling.
- Remove humidity indicators and look for desiccant dust or residue
on inside of manifold and humidity indicators.
- If desiccant dust or residue is seen Remove dryer for attention.
- If no desiccant dust or residue is seen on inside of manifold- Install
new humidity indicators. Again verify dryer is cycling correctly & No.1 main reservoir
drain valve is operating correctly Release loco for service.
• Yellow or Brown colour ----- Damaged dryer
-It indicates that desiccant has been contaminated
with oil. Replacement of coalescing element and
desiccant is required.
INSPECTION SCHEDULES OF AIR DRYER ON ELECTRIC LOCO
3. Check auto drain of main reservoir No.1 & main reservoir No.2
--It should function properly.
4. Check electrical connection of air dryer and their tightness.
IA/ IB SCHEDULE
IC - SCHEDULE
1. Repeat all the items of IA/IB schedules.
2. Charge the system from zero pressure and check the dryer
does not cycle immediately. Note the pressure when the
dryer starts cycling.
Pressure settings of start of cyclic operation are as under:
• FTIL air dryer ----- 7.0 kg/cm2
• SIL air dryer ----- 7.0 kg/cm2
• Knorr-Bremse air dryer ----- 4.6 kg/cm2
INSPECTION SCHEDULES OF AIR DRYER ON ELECTRIC LOCO
AOH SCHEDULE