Otis Sigma Tarjeta de Monitoreo
Otis Sigma Tarjeta de Monitoreo
Otis Sigma Tarjeta de Monitoreo
◆ Monitor Board
Duplex/group control
Group Flash-communication is connected
communication
F1 F2
MENU
( Main Board )
ESC ENTER
( Key Board )
Monitor Board
◆ LED
( Main Board )
Monitor Board
F1 F2
ENTER +
MENU
ESC ENTER
( Key Board )
Monitor Board
3. Error code
The AIO may store 20 failure codes. The most recent failure code is under No. 00.
Use up and down keys to view these failure codes. Press “Enter ”to view the date
of failure, press “left” and “right” to view the time and floor of the failure, and press
“ESC” to exit.
4. Hoistway Parameter
&
Monitor Board
The figure above means: GX0 has no input. Press "up“ and "down" keys to select GX serial
number from 0 to 15. After the GX matching numbers is selected, the highest level shows that
the input has no valid input (0 for no valid input, 1 for valid input).
Monitor Board
Parameter or
Data
Monitor Board
6. Process Diagnosis
This menu displays the current status of
the elevator by a two-digit number
Monitor Board
7. Command Registration
Press “up” and “down” to select the floor to
be commanded; press “Enter” to confirm and
the command is registered.
MENU
◆ LED 00
Display Code Contends Displayed Remark
◆ LED 01
Display Code Contends Displayed Remark
◆ LED 02
Display Code Contends Displayed Remark
Door lock relay (X17/parameter setup –if it is not in Running start
L1
normal light) condition of high
Main contactor contact input signal (without contactor speed. That all the
L2 11 lights are on
lighting)
indicates normal
Brake contactor contact input signal (without
L3 peripheral signal
contactor lighting)
and meets the start
L4 Brake switch requirements.
L5 Motor overheated
◆ LED 03
Display Code Contends Displayed Remark
◆ LED 04
Display Code Contends Displayed Remark
◆ LED 05
◆ LED 06
+ ENTER
Monitor Board
◆ LED 07
L1 Door lock relay (X17/parameter setup-if no normal light Start condition for
hoistway self
Main contactor contact input signal (without contactor
L2 study. That all the
lighting)
9 lights are on
Brake contactor contact input signal (without contactor indicates normal
L3
lighting) peripheral signal
L4 Brake switch and hoistway self
study may start.
L5 Motor overheated
+ ENTER L6 Upper limit switch (combined) status signal