DX-40, DX-60, DX-40 PLUS, DX-60 PLUS: Features

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

No.

59-0882-1 0010-10

PASSIVE INFRARED and MICROWAVE


COMBINATION DETECTOR

DX-40 , DX-60 , DX-40 PLUS , DX-60 PLUS


FEATURES
DX-40,DX-60,DX-40PLUS and DX-60PLUS - LED On/Off Switch
- Microwave Area Shaping Technology (Patent Pending) DX-40,DX-40PLUS Only
- Multifocus Optics Design (Patented) - Small Animal Immunity
- Automatic TROUBLE Monitoring (Patent Pending) DX-40PLUS,DX-60PLUS Only
- Microwave “Watchdog” Circuit - Separate Relay Output for Automatic Trouble Monitoring
- QUAD Zone Logic - Alarm Memory
- Temperature Compensation Logic - LED Remote Control Terminal
- Hassle-free Microwave Adjustment OPTIONAL BRACKET
- Sealed Optics FA-1W : Wall Mount Bracket : adjustable ±45° (Horizontally), 0-20° (Vertically downwards)
- 3 LED Walk Test Indication FA-3 : Compact Wall & Ceiling Bracket : adjustable ±45° (Horizontally), 0-10° (Vertically downwards)

1.INSTALLATION HINTS

Avoid direct sunlight. Avoid mounting detector where Avoid vapor or high humidity Avoid Curtain,Screen,etc. Do not install outdoors.
movement of Fans or Air that can cause condensation. blocking detection area.
Conditioning Fans can be detected.

Do not aim detection area towards


Do not install unit near Do not mount in unstable location equipment which continually
where vibration or shock may affect moves in the detection area Do not aim towards outside areas where there is
fluorescent lights. frequent movement.
the detector. (i.e.curtain, blinds).

2.DESCRIPTION AND OPERATION 3.DETECTION AREA

Microwave unit
Cover

Corner mount
knockout
LED Indicator

Mounting knockout
(Pitch=2.99"/76mm)
Lens

P.I.R. Sensor
(Do not touch)

P.C.B. unit

Tamper switch

Fastening screw
Terminals

Base

Wiring guide Wiring knockout


4.INSTALLATION

Lead in wires through knockouts along the wiring guide


on the rear side of base. Mount base with supplied
screws. When small animal immunity is required, refer
Loosen fastening screw and Release hook at top of unit. Remove to Section 6-E. When using a bracket, check matching
remove cover. P.C.B. unit from base. knockout position before opening mounting hole.

Fix P.C.B.unit into base. Supply Conduct walktest and make adjustments.
Wire according to Section 5. power. Allow 30 sec to warm up. (Section 6) Fit cover using fastening screw.
5.WIRING

DX-40,DX-60 DX-40 PLUS,DX-60 PLUS


TAMPER terminals to be
[ connected to a 24 hour
supervisory loop.
]
POWER INPUT SPARE TAMPER
POWER INPUT SPARE TAMPER (Non Short) (N.C.)
(9~18 VDC) (N.C.) (9~18 VDC)
Power wires should not exceed the following lengths. ALARM OUTPUT D.L.
ALARM OUTPUT DX-40,DX-60 DX-40 PLUS,DX-60 PLUS (N.C.) ALARM MEMORY
and WIRE SIZE 12V 14V 12V 14V * UL requires DX-40,DX-60 , TROUBLE OUTPUT
TROUBLE OUTPUT AWG 22(0.33mm2) 160m (530ft) 320m(1060ft) 140m(460ft) 280m(930ft) DX-40PLUS,DX-60PLUS to (N.C.)
(N.C.) be connected to a UL listed
AWG 20(0.52mm2) 250m (830ft) 500m(1660ft) 220m(730ft) 440m(1460ft)
power supply capable of providing a nominal input of 12VDC
*See Section 6-C AWG 18(0.83mm2) 400m (1330ft) 800m(2660ft) 350m(1160ft) 700m(2330ft) 35mA (max.) [DX-40,DX-60] , 12VDC 40mA (max.) [DX-
When using two or more units on one wire, the maximum length 40PLUS,DX-60PLUS] and battery standby time of 4 hours.
is obtained by dividing the maximum wire length listed above by * The equipment shall be installed in accordance with the
the number of units used. National Electrical Code, NFPA 70.

6.FUNCTIONS
TROUBLE OUTPUT SELECTOR 6 - A. LED ON/OFF
[DX-40,DX-60 Only]
Switch On or Off by adjusting the pin switch. LED will turn on
OFF

DETECTION MODE
under following status even if the pin switch is positioned to
SELECTOR Off.

1)During warm-up period (approx. 30 seconds)


ON

ALARM MEMORY 2)Alarm Memory indication


MICROWAVE SELECTOR 3)To indicate TROUBLE status (refer Section 6-C) LED ON/OFF
RANGE [DX-40PLUS SWITCH
SELECTOR DX-60PLUS Only]
* D.L. terminal / LED remote control terminal (DX-40 PLUS,DX-60 PLUS Only)
LED ON/OFF
SWITCH LED can be enabled or disabled remotely from control panel by D.L. terminal.
MICROWAVE
SENSITIVITY Place jumper pin switch in OFF position.
ADJUSTMENT
LED Enabled Connect D.L. terminal to common ground(with detector).
LED 1 (YELLOW) LED 2 (RED) LED 3 (GREEN) LED Disabled No ground to D.L. terminal (open circuit).
for M/W for ALARM for PIR
and
ALARM MEMORY
6 - B. MICRO WAVE ADJUSTMENT
Adjust microwave detection area by RANGE SELECTOR & SENSITIVITY ADJUSTMENT.

LONG
1) Select RANGE SELECTOR according to the room size
DX-40,DX-40PLUSLONG :10 - 12m (33ft-40ft) DX-60,DX-60PLUSLONG :12 - 18m (40ft-60ft)
SHORT : 5 - 9m (17ft-30ft) SHORT : 6 - 12m (20ft-40ft)
2) Position SENSITIVITY ADJUSTMENT to L firstly, then, along with Detector
walk testing, turn to H gradually until you get detection at the longest
distance for the required detection range.

SHORT
Guidance of SELECTOR and ADJUSTMENT position MICRO WAVE
RANGE
RANGE SELECTOR Short Short Short Long Long Long SELECTOR
SENS. ADJUSTMENT L M H L M H
Detection DX-40,DX-40PLUS 5m(17ft) 7m(23ft) 9m(30ft) 10m(33ft) 11m(37ft) 12m(40ft)
Range DX-60,DX-60PLUS 6m(20ft) 9m(30ft) 12m(40ft) 12m(40ft) 15m(50ft) 18m(60ft)
The chart shows any example of adjustments which may differ depending upon the
size and shape of the installation site. For good adjustment, conduct walk test
according to above 2).
Penetration
IMPORTANT
If Microwave detection range is set too wide, it may detect
movements outside of the detection area, resulting in false MICROWAVE
alarms. Do not adjust sensitivity too high. SENSITIVITY ADJUSTMENT

6 - C. AUTOMATIC TROUBLE MONITORING


DX-40,DX-60 series features automatic trouble monitoring which Microwave “Watchdog” Circuit
generate trouble signal when detection ability of PIR or Microwave is When microwave operation fails, the detector automatically switches to
compromised. back-up mode. In this mode, the PIR operates independently in order to
avoid missing alarms during microwave failure. Detection mode (refer to
1 ) . PIR detection failure section 6-D) turns into SP (Special) mode for enhanced reliability.
- Function
When something is blocking the PIR detection ability very near the YELLOW•@ RED GREEN
3) TROUBLE Output Indication
detector (up to approx. 20 cm), i.e. by paper, this function will
generate a TROUBLE signal. It requires the area to be blocked for When TROUBLE status occurs, the following
approx. 30 seconds or less. output will operate continually
- Reset of TROUBLE Output until the trouble is restored, i.e. blocking material
Remove blocking material and conduct a walk test. If PIR detects of PIR is removed.
properly, TROUBLE output will reset. - LED Operation
- Caution PIR Detection Failure : Yellow and Green LED’s flicker.
·Do not switch power down the detector during a TROUBLE status. Microwave Detection Failure : Red and Yellow LED’s flicker.
(It will reset TROUBLE output even if blocking material remains.) - Relay Output Terminals
·Cannot detect blocking away from the detector (up to approx. 20 cm) DX-40,DX-60
·In order for this feature to activate, an object must be placed within TROUBLE signals will output through the ALARM output terminals.
20cm of the detector which will reflect microwave. After this occurs,
ON

the detector counts any PIR detection's for or up to 30 seconds, and if SELECTOR ALARM OUTPUT
POSITION TERMINAL
there are no PIR detection's, the unit will generate a trouble signal. If
there is nothing to reflect microwave within 20cm of the detector, the ON Output ON
TROUBLE OUTPUT
trouble signal will not be sent, even if the PIR is blocked (i.e.Spray).
OFF

SELECTOR [DX-40, No Output


OFF
DX-60 Only] (LED Indication only)
2). Microwave detection failure (Self-Check)
- Function NOTE: When Alarm Output (ON) is selected and the detector goes into a
trouble condition, the Alarm Output will open and remain in the open position.
This function monitors signal wave shape of PIR and microwave’s
When the relay output is latched because of this type of trouble condition, the
human detection, and inspect microwave’s failure. Analysis requires
PIR only mode will not work. If PIR only mode is required, select Alarm Output
an average of 10 to 20 minutes. (OFF) and trouble will be indicated by LED only.
DX-40PLUS,DX-60PLUS
TROUBLE signals will output through TROUBLE output terminals. Yellow
6 - D. DETECTION MODE and Green LED’s flickers in turn.
SP.

Select STD(Standard) or SP(Special) position according to


environment conditions. 6 - F. ALARM MEMORY
STD : Select this position usually. Signals are analyzed twice. [DX-40 PLUS,DX-60 PLUS Only]
High reliability and sharp detection are available in this
NEG.

mode. Compatible Control Panel is required for


STD.

SP : For bad environments with moving objects in the Alarm Memory.


detection area (i.e. pets or animals). Select "POSITIVE" or "NEGATIVE" control.
Signals are analyzed 4 times for enhanced reliability. When DETECTION MODE Connect A.M. terminal to Control Panel's ALARM MEMORY
SELECTOR Control Voltage Signal terminal (System SELECTOR
POS.

walk testing, detection can be a little slower than STD mode. [DX-40 PLUS,
Arming Status Voltage Output). DX-60 PLUS Only]
6 - E. SPECIAL INSTRUCTIONS FOR SMALL ANIMAL IMMUNITY
[ DX-40 ,DX-40PLUS Only. Pet immunity function has not been evaluated by UL Position Negative Positive
since there are no established UL requirements for small animals immunity. ] System armed 0-1VDC (grounded) OPEN or +5~18VDC
1.Small animal immunity is most effective on animals less than 16 inches high. System disarmed OPEN or +5~18VDC 0-1VDC (grounded)
2.Installation instructions
"grounded" = A.M. terminal is electrically connected with power
a. Set detection mode jumper in the SP(special) position.
supply terminal (ground).
b. Mount between 7 and 8 ft.(for maximum immunity mount as close to
8ft. as possible). OPERATION OF ALARM MEMORY
c. Do not angle detector towards the ground or use the angle bracket. When the unit triggered during armed period, then the system is
Mount flat on the wall or in the corner. disarmed, Red LED will remain lit to confirm that it reported an
d. For best small animal immunity, limit the detectors field of view to 40 ft. alarm.
maximum in any direction. •Alarm Memory will operate even when LED is switched OFF.
e. For rodents, if any shelves within 15 ft. of the detector have a height that •Alarm Memory will not operate while system is disarmed.
comes wihtin 2.5 ft.below the detector, small animal immunity will be reduced. •After Alarm Memory latches, Alarm Output and Red LED operate
Please select a mounting location which will avoid this situation. normally during armed period.
f. For larger animals (16 inches in height or less at normal room temperatures),if
animals jump up on desks, shelves, or other furniture small animal immunity RESET
will be reduced. Adjust detection area to avoid such obstacles. Alarm Memory resets automatically when system is re-armed.
7.TROUBLE SHOOTING AND MAINTENANCE
INSTALLATION
Power is not supplied. Supply power
No Operation. Incorrect wiring. Correct wiring
Low power supply. Supply power between 9 to 18VDC
Unit is constantly in warm-up mode. Low power supply. Supply power between 9 to 18VDC

TROUBLE SHOOTING
Yellow LED does not light. Check if it detects
Increase Sensitivity (section 6-B).
(MW does not operate.) Check LED On/Off near from.
Green LED does not light. Switch and turn. Check if it detects Check if there are blocking materials in Remove blocking materials and
the detection area. For example, furniture's, Poles,
(PIR does not operate.) near from. High Plants, Partition etc.) conduct walk test again.

Strong RFI nearby. Moving fan or


Switch electrical equipment off.
Yellow LED lights even if no motor of air-conditioning vents etc.
person in detection area (MW Detection outside through wall. (Persons in the Adjust the detection range (section 6-B) and reduce sensitivity.
detects) next room, Water pipe in the wall etc.)
Movements of animals, curtains etc. Remove them from the detection area.
Wind direct hits detector. Strong Avoid them from hitting detectors directly. Possibly, better to
light hits detector. (sunlight, car avoid it from the detection area.
head light etc.)
Green LED lights even if no
person in detection area Rapid temperature changes in detection
(PIR detects) area (heating, air conditioning,
Remove such objects from detection area.
incandescent lamp etc.), moving animals,
or curtains etc.

Red & Yellow LED flicker. Failure of microwave Replace with new unit
unit
Green & Yellow LED flicker. Blocking materials in front of detector Remove blocking materials.

Trouble Output Switch is OFF. Turn it ON.


No output although Green &
Yellow (or Red & Yellow) LED Incorrect wiring Correct wiring
flicker. Replace with new unit
Relay is broken.
Incorrect wiring Correct wiring
No output although
Red LED lights. Replace with new unit
Relay is broken.
Incorrect wiring of Alarm Memory Correct wiring
Red LED continues to light
Improper Control Voltage from control panel Check control voltage.

CONDUCT WALK TEST AT LEAST ONCE A YEAR.


8.SPECIFICATIONS
DX-40,DX-60 DX-40 PLUS,DX-60 PLUS
Detection method Passive Infrared and Micro Wave Current draw 17mA (normal) , 40mA (max.) at 12VDC
Model DX-40 DX-60 D.L. terminal See Section 6-A
Coverange 40ft x 40ft (12m x 12m)85° wide 60ft x 60ft (18m x 18m)85° wide Alarm Memory See Section 6-F
Detection zones 82 zones(PIR) Trouble Output N.C., 28VDC 0.2A max.
Mounting Height 5 - 8ft(1.5 - 2.4m) 6 - 8ft(1.8 - 2.4m) Microwave Frequency 10.525GHz
3.6°F (2°C) 3.6°F(2°C)
Sensitivity
at 2ft / sec (0.6m / sec), 40ft (12m) at 2ft / sec (0.6m / sec), 60ft (18m)

Detectable speed 1 - 5ft / sec (0.3 - 1.5m / sec)


Alarm period Approx. 2 sec Dimensions
Alarm output N.C., 28VDC 0.2A max.
70 (2.76) 48.6 (1.91)
Tamper switch N.C.,Open when cover is removed.
Warm up period Approx. 30 sec
Flicker during warm-up.
RED : ALARM , ALARM MEMORY and TROUBLE indicator
LED indicator
YELLOW : MW and TROUBLE indicator
125 (4.92)

GREEN : P.I.R. and TROUBLE indicator


Power input 9 - 8VDC
Current draw 12mA (normal) , 35mA (max.) at 12VDC
RF interference NO Alarm 30V / m
Operating temperature 14°F - 122°F (-10°C - +50°C)
Environmental humidity 95% max.
Microwave Frequency 10.525GHz
mm (inches)
Weight 5.3oz (150g)

FCC Notice : This equipment has been tested and found to comply with the limits for a field disturbance sensor, pursuant to Part 15 of the FCC Rules. The user is cautioned
that changes or modifications not expressly approved by OPTEX could void the user's authority to operate this equipment.
* Specifications and design are subject to change without prior notice.

NOTE
This unit is designed to detect movement of an intruder and activate an alarm control panel. Being only OPTEX CO., LTD. (ISO 9001 Certified by LRQA)
a part of a conplete system,we cannot accept responsibility for any damages or other consequences 4-7-5 Nionohama Otsu 520-0801 Japan
TEL (077)524-6047 FAX (077)522-9022
resulting from an intrusion.
N219 OPTEX INCORPORATED.
1845W. 205th St. Torrance, CA 90501-1510 U.S.A.
TEL (310)533-1500 FAX (310)533-5910
59-0882-0 99-12