CR Data Book
CR Data Book
CR Data Book
Typical applications . . . . . . . . . . . . . . . . . . . . . . . 3 CR 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Pumped liquids. . . . . . . . . . . . . . . . . . . . . . . . . . 4 CRN 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
ErP compliant. . . . . . . . . . . . . . . . . . . . . . . . . . . 4 CR 45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
CRN 45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
CR 64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
2. Performance range . . . . . . . . . . . . . . . . . . . . 5
CRN 64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
CR 95 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
3. Product range. . . . . . . . . . . . . . . . . . . . . . . . . 6 CRN 95 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
CR 125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
4. Applications . . . . . . . . . . . . . . . . . . . . . . . . . . 8 CRN 125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
CR 155 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
CRN 155 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
5. Features and benefits . . . . . . . . . . . . . . . . . . 9
CR 185 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
CRN 185 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
CR 215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Terminal box positions . . . . . . . . . . . . . . . . . . . . 10
CRN 215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Ambient temperature . . . . . . . . . . . . . . . . . . . . . 10
CR 255 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Viscosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
CRN 255 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
9. Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Selection of pumps . . . . . . . . . . . . . . . . . . . . . . 24
How to read the curve charts . . . . . . . . . . . . . . . 28
Guidelines to performance curves . . . . . . . . . . . . 29
2
CR, CRI, CRN
1
Introduction
1. Introduction
This data booklet deals with Grundfos CR, CRI and CRN A CR pump consists of two main components: the motor
pumps. and the pump unit.
The motor is a Grundfos or Siemens motor designed to
EN standards.
The pump unit consists of optimized hydraulics, various
types of connections, a sleeve, a pump head and various
other parts.
CR pumps are available in various material versions
according to the pumped liquid.
Typical applications
The pumps are suitable for numerous applications. The
following applications are some typical examples.
Water supply:
• Filtration and transport waterworks
GR5381
• Distribution from waterworks
• Pressure boosting of mains.
CR, CRI and CRN 1s-64 Industrial:
• Pressure boosting
• Process water transfer
• Boiler feed
• Cooling and air conditioning
• Firefighting systems
• Special liquids transfer.
Water treatment:
TM069062
• Filtration
• Brackish water reverse osmosis.
Commercial building services:
CR, CRN 95-255
• Chilled-water systems
CR pumps are vertical multistage, centrifugal pumps. The • Hot-water systems
in-line design of the pumps enables installation in a • Pressure boosting
horizontal one-pipe system where the inlet and outlet
ports are in the same horizontal level and have the same • Boiler feed
pipe dimensions. This design provides a more compact • Firefighting systems
pump design.
• District energy systems.
The pumps are available in various sizes and various
numbers of stages to deliver the flow rate and pressure Related information
required. 4. Applications
CR pumps are designed for a variety of applications
ranging from the pumping of potable water to the pumping
of chemicals. The pumps are therefore suitable for a wide
diversity of pumping systems where the performance and
material of the pump meet specific demands.
3
1 CR, CRI, CRN
CR, CRI and CRN pumps are suitable for pumping liquids The product is energy-optimized and complies with the
which are thin, clean, non-flammable, non-combustible or ecodesign requirements for water pumps specified in the
non-explosive liquids, not containing solid particles or ErP Directive (Commission Regulation (EC) No
fibres. 547/2012), which became effective on 1 January 2013. As
When pumping liquids with a density and/or viscosity from this date, all pumps are classified and graduated in
higher than that of water, use motors with correspondingly the Minimum Efficiency Index (MEI).
higher outputs, if required.
Minimum efficiency index
Whether a pump is suitable for a particular liquid depends
on a number of factors of which the most important are Minimum efficiency index (MEI) means the dimensionless
chloride content, pH value, temperature, content of scale unit for hydraulic pump efficiency at best efficiency
chemicals and oils. Please consult Grundfos for point (BEP), part load (PL) and overload (OL). The
information about which pump types are suitable for a Commission Regulation (EU) sets efficiency requirements
specific liquid. to MEI ≥ 0.10 as from 1 January 2013 and MEI ≥ 0.40 as
from 1 January 2015. An indicative benchmark for best-
CR and CRI performing water pump available on the market as from 1
CR and CRI pumps are suitable for non-corrosive liquids. January 2013 is determined in the Commission
Use CR or CRI pumps for liquid transfer, circulation and Regulation.
pressure boosting of cold or hot clean water. • The benchmark for most efficient water pumps is MEI
CRN ≥ 0.70.
CRN pumps are suitable for industrial liquids. • The efficiency of a pump with a trimmed impeller is
Use CRN pumps in systems where all parts in contact usually lower than that of a pump with the full impeller
with the liquid must be made of high-grade stainless steel. diameter. The trimming of the impeller will adapt the
pump to a fixed duty point, leading to reduced energy
CRT
consumption. The minimum efficiency index (MEI) is
For saline or chloride-containing liquids such as sea water based on the full impeller diameter.
or for oxidising agents such as hypochlorites, we offer
CRT pumps made of titanium. • The operation of this water pump with variable duty
points may be more efficient and economic when
• See the separate data booklet on CRT, CRTE controlled, for example, by the use of a variable-speed
available on Grundfos Product Center (http://product- drive that matches the pump duty to the system.
selection.grundfos.com/).
• Information on benchmark efficiency is available at
Related information http://europump.eu/efficiencycharts.
12. List of pumped liquids
MEI values for CR pumps
Pump type MEI
CR 1s-3 0.54
CR 1-3 > 0.70
CR 3-3 > 0.70
CR 5-3 0.57
CR 10-3 > 0.70
CR 15-3 > 0.70
CR 20-3 > 0.70
CR 32-3 > 0.70
CR 45-3 > 0.70
CR 64-3 > 0.70
CR 95-3 > 0.70
CR 125-3 > 0.70
CR 155-3 > 0.70
CR 185-3 > 0.70
CR 215-3 ≥ 0.70
CR 255-3 ≥ 0.70
4
CR, CRI, CRN
2
Performance range
2. Performance range
TM021192
Performance range for CR, CRI, CRN 50 Hz
- - - - - High-pressure range
5
3 CR, CRI, CRN
Product range
3. Product range
Flow rate [m3/h] 0.3 - 1.1 0.7 - 2.4 1.2 - 4.5 2.5 - 8.5 5-13 9-24 11-29
Minimum liquid temperature [°C]1) -20 -20 -20 -20 -20 -20 -20
Maximum liquid temperature [°C]1) 120 120 120 120 120 120 120
Maximum pump efficiency [%] 35 48 58 66 70 72 72
Maximum pressure [bar] 21 22 24 24 22 23 25
High pressure [bar], on request (CRN) - 47 41 47 44 47 48
Motor power [kW] 0.37 - 1.1 0.37 - 2.2 0.37 - 3 0.37 - 5.5 0.37 - 7.5 1.1 - 15 1.1 - 18.5
Standard versions
CR:
Cast iron and stainless steel ● ● ● ● ● ● ●
EN 10088 1.4301≈AISI 304
CRI:
Stainless steel ● ● ● ● ● ● ●
EN 10088 1.4301≈AISI 304
CRN:
Stainless steel ● ● ● ● ● ● ●
EN 10088 1.4401≈AISI 316
CRT: See the CRT, CRTE data booklet available on Grundfos Product Center at http://product-
Titanium selection.grundfos.com or http://net.grundfos.com/qr/i/V7149894
CR pipe connection
Oval flange (BSP) Rp 1 Rp 1 Rp 1 Rp 1 1/4 Rp 1 1/4 Rp 2 Rp 2
Rp 1 1/4
Oval flange (BSP), on request Rp 1 1/4 Rp 1 1/4 Rp 1 1/4 Rp 1 Rp 2 1/2 Rp 2 1/2
Rp 2
DN 25/ DN 25/ DN 25/ DN 25/
Flange DN 40 DN 50 DN 50
DN 32 DN 32 DN 32 DN 32
Flange, on request - - - - DN 50 - -
CRI pipe connection
Oval flange (BSP) Rp 1 Rp 1 Rp 1 1/4 Rp 1 1/4 Rp 1 1/2 Rp 2 Rp 2
Oval flange (BSP), on request Rp 1 1/4 Rp 1 1/4 Rp 1 Rp 1 Rp 2 - -
DN 25/ DN 25/ DN 25/ DN 25/
Flange DN 40 DN 50 DN 50
DN 32 DN 32 DN 32 DN 32
Flange, on request - - - - DN 50 - -
R 1 1/4 R 1 1/4 R 1 1/4 R 1 1/4 R2 R2 R2
PJE coupling (Victaulic type)
DN 32 DN 32 DN 32 DN 32 DN 50 DN 50 DN 50
Clamp coupling (L-coupling) ∅48.3 ∅48.3 ∅48.3 ∅48.3 ∅60.3 ∅60.3 ∅60.3
Union (+GF+) G2 G2 G2 G2 G 2 3/4 G 2 3/4 G 2 3/4
CRN pipe connection
Oval flange (BSP) Rp 1 Rp 1 Rp 1 1/4 Rp 1 1/4 Rp 1 1/2 Rp 2 Rp 2
Oval flange (BSP), on request Rp 1 1/4 Rp 1 1/4 Rp 1 Rp 1 Rp 2 - -
DN 25/ DN 25/ DN 25/ DN 25/
Flange DN 40 DN 50 DN 50
DN 32 DN 32 DN 32 DN 32
Flange, on request - - - - DN 50 - -
R 1 1/4 R 1 1/4 R 1 1/4 R 1 1/4 R2 R2 R2
PJE coupling (Victaulic type)
DN 32 DN 32 DN 32 DN 32 DN 50 DN 50 DN 50
Clamp coupling (L-coupling) ∅42.2 ∅42.2 ∅42.2 ∅42.2 ∅60.3 ∅60.3 ∅60.3
Union (+GF+) G2 G2 G2 G2 G 2 3/4 G 2 3/4 G 2 3/4
● Standard.
1) Liquid temperature -40 to +180 °C (oils up to 240 °C) is available on request.
6
CR, CRI, CRN
3
Product range
CR, CRN pump size 32 45 64 95 125 155 185 215 255
Rated flow rate [m3/h] 32 45 64 95 125 155 185 215 255
Flow rate [m3/h] 15-40 22-58 30-85 45-120 60-160 75-200 92-240 108-280 128–330
Minimum liquid temperature [°C]1) -30 -30 -30 -20 -20 -20 -20 -20 -20
Maximum liquid temperature [°C]2) 120 120 120 120 120 120 120 120 120
Maximum pump efficiency [%] 78 79 80 81 82 82 82 84 85
Maximum pressure [bar] 28 33 22 23 323) 273) 35 32 28
High pressure [bar], on request (CRN) 50 49 41 - - - - - -
Motor power [kW] 1.5 - 30 3-45 4-45 5.5 - 55 11-110 11-110 18.5 - 200 22-200 30-200
Standard versions
CR:
Cast iron and stainless steel ● ● ● ● ● ● ● ● ●
EN 10088 1.4301≈AISI 304
CRN:
Stainless steel ● ● ● ● ● ● ● ● ●
EN 10088 1.4401≈AISI 316
CR pipe connection
Oval flange (BSP) - - - - - - - - -
Oval flange (BSP), on request - - - - - - - - -
Flange DN 65 DN 80 DN 100 DN 100 DN 150 DN 150 DN 200 DN 200 DN 200
Flange, on request DN 80 DN 100 DN 125 - - - - - -
CRN pipe connection
Oval flange (BSP) - - - - - - - - -
Oval flange (BSP), on request - - - - - - - - -
Flange DN 65 DN 80 DN 100 DN 100 DN 150 DN 150 DN 200 DN 200 DN 200
Flange, on request DN 80 DN 100 DN 125 - - - - - -
PJE coupling (Victaulic type) 3" 4" 4" 4" 6" 6" 8" 8" 8"
Clamp coupling (L-coupling) 88.9 114.3 114.3 114.3 168.3 168.3 219.1 219.1 219.1
Union (+GF+) - - - - - - - - -
● Standard.
1) Minimum liquid temperature down to -40 °C is available on request.
2) CR, CRN 32-155: Maximum liquid temperature up to +180 °C (oils up to 240 °C) is available on request.
3) CR pumps: Maximum operating pressure is 25 bar.
7
4 CR, CRI, CRN
Applications
4. Applications
Water supply
CR, CRI CRN
Filtration and transfer at waterworks ● ❍
Distribution from waterworks ● ❍
Pressure boosting in mains ● ❍
Pressure boosting in, for example, high-rise buildings, hotels ● ❍
Pressure boosting for industrial water supply ● ❍
Industry
CR, CRI CRN
Pressure boosting
Process-water systems ● ●
Washing and cleaning systems ● ●
Vehicle-washing tunnels ● ❍
Firefighting systems ● -
Liquid transfer
Cooling and air-conditioning systems (refrigerants) ● ❍
Boiler feed and condensate systems ● ❍
Machine tools (cooling lubricants) ● ●
Aquafarming ● ❍
Special transfer duties
Oils and alcohols ● ●
Acids and alkalis - ●
Glycol and coolants ● -
Water treatment
CR, CRI CRN
Ultra-filtration systems - ●
Reverse osmosis systems - ●
Softening, ionising, demineralising systems - ●
Distillation systems - ●
Separators ● ●
Swimming baths - ●
Irrigation
CR, CRI CRN
Field irrigation (flooding) ● ❍
Sprinkler irrigation ● ❍
Drip-feed irrigation ● ❍
● Recommended version.
❍ Alternative version.
Note that for applications involving CIP (clean-in-place) and CR, CRN 95-255 pumps with motors above 55 kW, you must
use a bearing flange and a base without thrust handling device.
8
CR, CRI, CRN
5
CR pump 1)
IP44 and IP54 are available on request.
Grundfos E-motors
Pos. Description
We also offer frequency-controlled CRE pumps which are
1 Motor
the ideal choice for a number of applications
2 Coupling characterized by a demand for variable flow rate at
3 Pump head constant pressure. These pumps are suited for water
4 Sleeve supply systems and pressure boosting as well as for
5 Staybolts industrial applications. Depending on the application, the
pumps offer energy savings, increased comfort and
6 Base plate
improved processing.
7 Base
See the CRE, CRIE, CRNE data booklet available on
8 Impellers Grundfos Product Center (http://product-
9 Shaft seal (cartridge type) selection.grundfos.com/).
Optional motors
The Grundfos standard range of motors covers a wide
variety of application demands. However, for special
applications or operating conditions, custom-built motor
solutions can be provided, such as the following:
• ATEX-approved motors
• MG motors with anti-condensation heating unit
• motors with thermal protection.
9
5 CR, CRI, CRN
motors
Maximum Maximum
Single-phase Grundfos motors have a built-in thermal Motor Motor ambient altitude above
power Motor make efficiency temperature
overload switch (TP 211 according to IEC 34-11). sea level
[kW] class
Three-phase motors must be connected to a motor- [°C] [m]
protective circuit breaker according to local regulations. 0.37 - 0.55 MG - 40 1000
Three-phase Grundfos motors as from 3 kW have a built- 0.75 - 22 MG IE3 60 3500
in thermistor (PTC) according to DIN 44082 (TP 211 30-200 Siemens IE3 55 2750
according to IEC 34-11).
If the ambient temperature exceeds the above maximum
Terminal box positions temperatures or the pump is installed at an altitude
As standard, the terminal box is fitted on the inlet side of exceeding the above altitude values, the motor must not
the pump. be fully loaded due to the risk of overheating. Overheating
may result from excessive ambient temperatures or the
low density and consequently low cooling effect of the air.
In such cases, it may be necessary to use a motor with a
higher rated output.
P2
TM033658 [%]
3
100
1 2 3 4 2
90
1
Terminal box positions 80
70
60
Pos. Description
50
1 6 o'clock position (standard)
20 25 30 35 40 45 50 55 60 65 70 75 80
TM032479
2 9 o'clock position t [°C]
3 12 o'clock position
1000 2250 3500 4750 m
4 3 o'clock position
Motor output in relation to temperature and altitude
Motor power
Pos. Motor make
[kW]
1 0.37 - 0.55 MG
2 0.75 - 22 MG
3 30-200 Siemens
Viscosity
Pumping liquids with densities or kinematic viscosities
higher than those of water will cause a considerable
pressure drop, a drop in the hydraulic performance and a
rise in the power consumption.
In such situations, the pump must be fitted with a larger
motor. If in doubt, contact Grundfos.
10
CR, CRI, CRN
6
Construction
6. Construction
3
10
4
6
5 7
9
11
8
TM021194
Materials, CR
Pos. Designation Materials DIN/EN ≈ AISI/ASTM
1 Pump head Grey cast iron EN 1561 EN-GJL-200 ASTM 25B
EN 10088 1.4401 1) AISI 316 1)
3 Shaft Stainless steel
EN 10088 1.4057 2) AISI 431 2)
4 Impeller Stainless steel EN 10088 1.4301 AISI 304
5 Chamber Stainless steel EN 10088 1.4301 AISI 304
6 Sleeve Stainless steel EN 10088 1.4301 AISI 304
7 O-ring for sleeve EPDM or FKM - -
8 Base Grey cast iron EN 1561 EN-GJL-250 ASTM 25B
9 Neck ring PTFE - -
10 Shaft seal (seal faces) Silicon carbide/silicon carbide - -
11 Bearing ring Silicon carbide/silicon carbide - -
Staybolts Bright steel EN 10277-2 1.0533 -
1) CR 1s, 1, 3, 5.
2) CR 10, 15, 20.
11
6 CR, CRI, CRN
2 10
5 6
7
9 11
TM021195
8 12
Materials, CRI
Pos. Designation Materials DIN/EN ≈ AISI/ASTM
1 Motor stool Grey cast iron 1) EN 1563 EN-GJS-450-10 ASTM A536 65-45-12
2 Pump head Stainless steel EN 10283 1.4408 CF 8M equal to AISI 316
EN 10088 1.4401 2) AISI 316 2)
3 Shaft Stainless steel
EN 10088 1.4057 3) AISI 431 3)
4 Impeller Stainless steel EN 10088 1.4301 AISI 304
5 Chamber Stainless steel EN 10088 1.4301 AISI 304
6 Sleeve Stainless steel EN 10088 1.4301 AISI 304
7 O-ring for sleeve EPDM or FKM - -
8 Base Stainless steel EN 10283 1.4408 CF 8M equal to AISI 316
9 Neck ring PTFE - -
10 Shaft seal (seal faces) Silicon carbide/silicon carbide - -
11 Bearing ring Silicon carbide/silicon carbide - -
EN 1561 EN-GJL-200 3) + 4) ASTM 25B 3) + 4)
12 Base plate Grey cast iron 1) 5)
EN 1563 EN-GJS-500-7 ASTM A536 65-45-12 5)
Staybolts Bright steel EN 10277-2 1.0533 -
12
CR, CRI, CRN
6
Construction
1
2 10
5 6
7
9 11
TM021195
8 12
Materials, CRN
Pos. Designation Materials DIN/EN ≈ AISI/ASTM
1 Motor stool Grey cast iron 1) EN 1563 EN-GJS-450-10 ASTM A536 65-45-12
2 Pump head Stainless steel EN 10283 1.4408 CF 8M equal to AISI 316
EN 10088 1.4401 2) AISI 316 2)
3 Shaft Stainless steel
EN 10088 1.4460 3) AISI 329 3)
4 Impeller Stainless steel EN 10088 1.4401 AISI 316
5 Chamber Stainless steel EN 10088 1.4401 AISI 316
6 Sleeve Stainless steel EN 10088 1.4401 AISI 316
7 O-ring for sleeve EPDM or FKM - -
8 Base Stainless steel EN 10283 1.4408 CF 8M equal to AISI 316
9 Neck ring PTFE - -
10 Shaft seal (seal faces) Silicon carbide/silicon carbide - -
11 Bearing ring Silicon carbide/silicon carbide - -
EN 1561 EN-GJL-200 3) + 4) ASTM 25B 3) + 4)
12 Base plate Grey cast iron 1) 5)
EN 1563 EN-GJS-500-7 ASTM A536 65-45-12 5)
EN 10088 1.4401 2) AISI 316 2)
Staybolts Stainless steel
EN 10088 1.4057 3) AISI 431 3)
13
6 CR, CRI, CRN
CR 32, 45, 64
Construction
10
1
6
4
11
5
7
12
TM060711
Materials, CR
Pos. Designation Materials DIN/EN ≈ AISI/ASTM
1 Pump head Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536 65-45-12
2 Motor stool Grey cast iron EN 1561 EN-GJL-200 ASTM 25B
3 Shaft Stainless steel EN 10088 1.4057 AISI 431
4 Impeller Stainless steel EN 10088 1.4301 AISI 304
5 Chamber Stainless steel EN 10088 1.4301 AISI 304
6 Sleeve Stainless steel EN 10088 1.4301 AISI 304
7 O-ring for sleeve EPDM or FKM - -
8 Base Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536 65-45-12
9 Neck ring Carbon-graphite-filled PTFE - -
10 Shaft seal (seal faces) Silicon carbide/silicon carbide - -
11 Bearing ring Silicon carbide/silicon carbide - -
12 Support bearing Carbon-graphite-filled PTFE - -
13 Base plate Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536 65-45-12
Staybolts Bright steel EN 10277-2 1.0533 -
14
CR, CRI, CRN
6
Construction
2
10
1
6
4
11
5
12
7
TM060712
13
Materials, CRN
Pos. Designation Materials DIN/EN ≈ AISI/ASTM
1 Pump head Stainless steel EN 10283 1.4408 CF 8M equal to AISI 316
2 Motor stool Grey cast iron 1) EN 1561 EN-GJL-200 ASTM 25B
3 Shaft Stainless steel EN 10088 1.4462 -
4 Impeller Stainless steel EN 10088 1.4401 AISI 316
5 Chamber Stainless steel EN 10088 1.4401 AISI 316
6 Sleeve Stainless steel EN 10088 1.4401 AISI 316
7 O-ring for sleeve EPDM or FKM -
8 Base Stainless steel EN 10283 1.4408 CF 8M equal to AISI 316
9 Neck ring Carbon-graphite-filled PTFE - -
10 Shaft seal (seal faces) Silicon carbide/silicon carbide - -
11 Bearing ring Silicon carbide/silicon carbide - -
12 Support bearing Carbon-graphite-filled PTFE - -
13 Base plate Ductile cast iron 1) EN 1563 EN-GJS-500-7 ASTM A536 65-45-12
Staybolts Stainless steel EN 10088 1.4057 AISI 431
15
6 CR, CRI, CRN
1
2
3
4
5
6
7
8
9
10
11
TM065161
12
13
Materials, CR
Pos. Designation Materials DIN/EN ≈ AISI/ASTM
1 Motor stool Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536-84 65-45-12
EN 10088 1.4057 1) AISI 431 1)
2 Shaft Stainless steel
EN 10088 1.4462 2) AISI 318 LN 2)
3 Shaft seal (seal faces) Silicon carbide/silicon carbide - -
4 Pump head Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536-84 65-45-12
5 Support bearing (bush) Carbon-graphite-filled PTFE
EN 10088 1.4301 AISI 304
6 Impeller Stainless steel
EN 10088 1.4401 3) AISI 316 3)
7 Neck ring PEEK - -
EN 10088 1.4301 AISI 304
8 Chamber Stainless steel
EN 10088 1.4401 3) AISI 316 3)
EN 10088 1.4301 1) AISI 304 1)
9 Sleeve Stainless steel
EN 10088 1.4404 2) AISI 316 L 2)
10 Bearing ring Tungsten carbide/tungsten carbide - -
EN 10088 1.4401
Stainless steel AISI 316 CF 8M equal to AISI 316
11 Thrust handling device 4) EN 10283 1.4408
Silicon carbide/tungsten carbide - -
12 Base Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536-84 65-45-12
13 Base plate Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536-84 65-45-12
Staybolts Stainless steel EN10088 1.4057 AISI 431
1) CR 95.
2) CR 125, 155, 185, 215, 255.
3) CR 185, 215, 255.
4) If fitted.
16
CR, CRI, CRN
6
Construction
1
2
3
4
5
6
7
8
9
10
11
TM065161
12
13
Materials, CRN
Pos. Designation Materials DIN/EN ≈ AISI/ASTM
1 Motor stool Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536-84 65-45-12
2 Shaft Stainless steel EN 10088 1.4462 318 LN
3 Shaft seal (seal faces) Silicon carbide/silicon carbide - -
4 Pump head Stainless steel EN 10283 1.4408 CF 8M
5 Support bearing (bush) Carbon-graphite-filled PTFE - -
6 Impeller Stainless steel EN 10088 1.4401 AISI 316
7 Neck ring PEEK - -
8 Chamber Stainless steel EN 10088 1.4401 AISI 316
9 Sleeve Stainless steel EN 10088 1.4404 AISI 316 L
10 Bearing ring Tungsten carbide/tungsten carbide - -
EN 10088 1.4401 AISI 316
Stainless steel
11 Thrust handling device 1) EN 10283 1.4408 CF 8M equal to AISI 316
Silicon carbide/tungsten carbide - -
12 Base Stainless steel EN 10283 1.4408 CF 8M
13 Base plate Ductile cast iron EN 1563 EN-GJS-500-7 ASTM A536-84 65-45-12
Staybolts Stainless steel EN10088 1.4057 AISI 431
1) If fitted.
17
7 CR, CRI, CRN
Identification
7. Identification
Type key Code Description
CX TriClamp
Example
F DIN flange
CRE 32-3-2 A-F-A-E-HQQE
FC DIN 11853-2 flange (collar flange)
Code Explanation FE EN 1092-1, type E
CR Type range: CR, CRI, CRN, CRT G ANSI flange
E Pump with integrated frequency converter J JIS flange
32 Flow rate [m3/h] N Changed diameter of ports
3 Number of impellers P PJE coupling (Victaulic type)
2 Number of reduced-diameter impellers X Special version
A Code for pump version Materials
F Code for pipe connection A Basic version
A Code for materials C Carbon-free pump
E Code for rubber parts D Carbon-graphite-filled PTFE (bearings)/tungsten carbide
Code for shaft seal: E Pickled and passivated (Only Japan)
H
• Shaft seal type designation
Q H Flanges and base plate EN 1.4408
• Seal face material (rotating seal face)
Q K Bronze (bearings)/tungsten carbide
• Seal face material (stationary seal face)
E
• Secondary seal material (rubber parts) L Motor stool, base plate and flanges EN 1.4408
Motor stool, base plate, coupling and flanges EN 1.4408 and
Key to codes M coupling guards in cobber. Bolts, nuts and spacing pipes EN
1.4401 or higher grade
Code Description N Flanges EN 1.4408
Pump version P PEEK neck ring
A Basic version Silicon carbide/silicon carbide bearing in pump and silicon
Q
carbide/silicon carbide seal faces in thrust handling device
B Oversize motor
R Silicon carbide/silicon carbide bearing
C CR compact
S PTFE neck rings
D Pump with pressure intensifier
T Base plate EN 1.4408
E Pump with certificate
Silicon carbide/silicon carbide bearing in pump and silicon
F Pump for high temperatures (with air-cooled top) U
carbide/tungsten carbide seal faces in thrust handling device
G E-pump without operating panel
W Tungsten carbide/tungsten carbide
H Horizontal version
X Special version
I Different pressure rating
Rubber parts in pump
J E-pump with a different maximum speed
E EPDM
K Pump with low NPSH
F FXM (Fluoraz®)
L Pump including Grundfos CUE and certificate
K FFKM (Kalrez®)
M Magnetic drive
N CR (Neoprene)
N With sensor
V FKM (Viton®)
O Cleaned and dried
Shaft seal type designation
P Undersize motor
A O-ring seal with fixed driver
Q High-pressure pump with high-speed MGE motor
H Balanced cartridge seal with O-ring
R Belt-driven pump
O Double seal, back-to-back
S High-pressure pump
P Double seal, tandem
T Thrust handling device
X Special version
U ATEX-approved pump
Seal face material (rotating and stationary seal face)
V Cascade function
B Carbon, synthetic resin-impregnated
W Deep-well pump with ejector
U Cemented tungsten carbide
X Special version
Q Silicon carbide
Y Electropolished
X Other ceramics
Z Pumps with bearing flange
Secondary seal material (rubber parts)
Pipe connection
A Oval flange
B NPT thread
CA FlexiClamp
18
CR, CRI, CRN
7
Identification
Code Description
E EPDM
F FXM (Fluoraz®)
K FFKM (Kalrez®)
V FKM (Viton®)
19
8 CR, CRI, CRN
Operating conditions
8. Operating conditions
Flange type
TM021383
TM021379
Maximum permissible Maximum permissible
Pump type Liquid temperature Liquid temperature
operating pressure 1) operating pressure 1)
[bar] [°C] [bar] [°C]
CR, CRI, CRN 1s 16 25
CR, CRI, CRN 1 16 25
CR, CRI, CRN 3 16 -20 to +120 25
CR, CRI, CRN 5 16 25 -20 to +120
CR, CRI 10-1 → 10-16 16 16
CR, CRI 10-17 → 10-22 - - 25
CRN 10 - - 25
CR, CRI 15-1 → 15-7 10 -20 to +120 - -
CR, CRI 15-1 → 15-10 - - 16
CR, CRI 15-12 → 15-17 - - 25 -20 to +120
CRN 15 - - 25
CR, CRI 20-1 → 20-7 10 -20 to +120 - -
CR, CRI 20-1 → 20-10 - - 16
CR, CRI 20-12 → 20-17 - - 25 -20 to +120
CRN 20 - - 25
CR, CRN 32-1-1 → 32-7 - - 16
CR, CRN 32-8-2 → 32-14 - - 30
CR, CRN 45-1-1 → 45-5 - - 16
CR, CRN 45-6-2 → 45-11 - - 30 -30 to +120
CR, CRN 45-12-2 → 45-13-2 - - 33
CR, CRN 64-1-1 → 64-5 - - 16
CR, CRN 64-6-2 → 64-8-1 - - 30
1) In standard configurations. For operating conditions outside the standard, contact Grundfos.
20
CR, CRI, CRN
8
Operating conditions
Oval flange PJE, clamp, union, DIN
Flange type
TM021383
TM021379
Maximum permissible Maximum permissible
Pump type Liquid temperature Liquid temperature
operating pressure 1) operating pressure 1)
[bar] [°C] [bar] [°C]
CR, CRN 95-1-1 → 95-5 - - 16
CR, CRN 95-6 → 95-8-2 - - 25
CR, CRN 125-1 → 125-4 - - 16
CR, CRN 125-5 - - 25
CRN 125-6 → 125-7 - - 25
CRN 125-8 → 125-10 - - 40
CR, CRN 155-1-1 → 155-4-1 - - 16
CRN 155-5-2 → 155-6 - - 25
CRN 155-7 → 155-8-2 - - 40
-20 to +120 2)
CR, CRN 185-1 → 185-3 - - 16
CR, CRN 185-4-3 → 185-5 - - 25
CR, CRN 185-6-3 → 185-8 - - 40
CR, CRN 215-1-1 → 215-3 - - 16
CR, CRN 215-4-2 → 215-5 - - 25
CR, CRN 215-6-3 → 215-7-2 - - 40
CR, CRN 255-1-1 → 255-3-2 - - 16
CR, CRN 255-3 → 255-4 - - 25
CR, CRN 255-5-3 → 255-6-2 - - 40
1) In standard configurations. For operating conditions outside the standard, contact Grundfos.
2) For operating pressures above 25 bar, see section about operating range of the shaft seal.
21
8 CR, CRI, CRN
Operating range of the shaft seal ∅28 and ∅36 shaft seals (75-200 kW)
Operating conditions
HQQE
20 HQQE/V HQQE
For selection of the right shaft seal, see section with list of HBQE/V HBQE
pumped liquids. If the operating range is exceeded, the 10
TM061409
life of the shaft seal may be reduced.
0
Note that if you pump demineralized water with a -40 -20 0 20 40 60 80 100 120 140 t [°C]
conductivity below 2 μS/cm with a pump equipped with a
silicon carbide/silicon carbide shaft seal, there is an Operating range of standard shaft seals for CR, CRN
increased risk of electrochemical corrosion. We 125-255
recommend that you use a silicon carbide/carbon or
silicon carbide/tungsten carbide shaft seal instead.
Motor Liquid
Standard
Related information size Description temperature
shaft seal
[kW] [°C]
Shaft seals for CR, CRI, CRN 1s-255
O-ring (cartridge) (balanced
12. List of pumped liquids HQQE seal), silicon carbide/silicon -40 to +120
carbide, EPDM
14. Variants
O-ring (cartridge) (balanced
Shaft seals for CR, CRI, CRN 1s-255 HQQV seal), silicon carbide/silicon
carbide, FKM
-20 to +90
20 HQQE/V HQQE
HQBE/V HQBE
10
TM061408
0
-40 -20 0 20 40 60 80 100 120 140 t [°C]
Motor Liquid
Standard size temperature
Description
shaft seal
[kW] [°C]
O-ring (cartridge) (balanced
HQQE seal), silicon carbide/silicon -40 to +120
carbide, EPDM
O-ring (cartridge) (balanced
HQQV seal), silicon carbide/silicon -20 to +90
carbide, FKM
0.37 - 55
O-ring (cartridge) (balanced
HQBE seal), silicon carbide/carbon, 0 to 120
EPDM
O-ring (cartridge) (balanced
HQBV seal), silicon carbide/carbon, 0 to 90
FKM
22
CR, CRI, CRN
8
Operating conditions
Maximum inlet pressure
Pump type and stages
[bar]
The following table shows the maximum permissible inlet
CR, CRN 215
pressure. However, the outlet pressure, which is the
actual inlet pressure plus the pressure delivered by the 215-1-1 → 215-2-2 15
215-2-1 → 215-7-2 20
pump must always be lower than the maximum
permissible operating pressure. CR, CRN 255
23
9 CR, CRI, CRN
Selection
9. Selection
Selection of pumps Pump efficiency
Before determining the best efficiency point, identify the
Base the selection of pumps on these parameters:
operation pattern of the pump. If the pump is expected to
• Duty point of the pump. See section about duty point always operate at the same duty point, select a pump
of the pump. which is operating at a duty point corresponding to the
• Sizing data such as pressure loss as a result of height best efficiency of the pump.
differences, friction loss in the pipes, pump efficiency.
See section about sizing data. p H
[MPa] [m]
280 -14
CR --
-14-2
• Pump materials. See section about pump material. 260 -13
-13-2
xx Hz
ISO 9906:2012 Grade 3B
2.4
• Pump connections. See section about pump 240 -12
-12-2
140 -7
From a duty point, you can select a pump on the basis of 1.2 120 -6
-7-2
-5-2
Ideally, the duty point should match the best efficiency on 0.8 80 -4
-4-2
the pump curve. 60 -3
-3-2
0.5
40
20
When sizing a pump, take these parameters into account: 0.0 0.0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
p H NPSH
• Required flow rate and pressure at the draw-off point. [kPa]
200
[m]
20 QH 2900 rpm 1/1 8
[m]
10
6
4
80
TM078851
5 NPSH 2
• Friction loss in the pipes (Hf). It may be necessary to 40
0 0 0
TM009190
Q [ m3 /h ]
Sizing data
Best efficiency
Pos. Description
Pos. Description
1 Required flow rate, required pressure
1 Best efficiency point
24
CR, CRI, CRN
9
Pump material Shaft seal
Selection
Select the material variant on the basis of the liquid to be
pumped.
The product range covers the following basic types.
• CR, CRI: Use CR, CRI pumps for clean, non-
aggressive liquids, such as potable water and oils.
GR7386
• CRN: Use CRN pumps for industrial liquids and acids.
See section about list of pumped liquids, or contact
Grundfos.
Shaft seal (cartridge type)
For saline or chloride-containing liquids, such as sea
water, CRT pumps of titanium are available.
As standard, the CR range is fitted with a Grundfos shaft
seal (cartridge type), which is suitable for the most
common applications.
The following key parameters must be taken into account
when selecting the shaft seal:
• type of pumped liquid
• liquid temperature
• maximum pressure.
We offer a wide range of shaft seal variants to meet
specific demands according to the pumped liquid.
TM069206
F (DIN)
A PJE
TM021201
Pump connections
25
9 CR, CRI, CRN
TM069669
• The flow rate is significantly higher than the rated flow
rate.
• Water is drawn from depths.
Thrust handling device • Water is drawn through long pipes.
• Inlet conditions are poor.
A thrust handling device (THD) is factory-fitted on pumps
with 75 kW motors or larger. The system consists of two To avoid cavitation, make sure that there is a minimum
parts. A rotating part mounted on the shaft end below the pressure on the inlet side of the pump.
first impeller as well as a non-rotating part mounted in or Calculate the maximum suction lift "H" in metres head as
on the pump base. follows:
The THD absorbs the main part of the thrust force
H = pb x 10.2 - NPSH - Hf - Hv
generated by the impellers and thereby reduces the
resulting axial force the motor bearings must absorb. This
Barometric pressure in bar.
enables the use of standard ball bearings in the motor
Pb can be set to 1 bar at sea level.
instead of special angular contact ball bearings. pb =
In closed systems, pb indicates the system pressure in
Note: For applications involving CIP (clean-in-place) and bar.
motors above 55 kW, use a bearing flange and a base Net Positive Suction Head in metres head. To be read
without THD. NPSH = from the NPSH curve at the highest flow rate the pump will
be delivering.
Friction loss in inlet pipe in metres head at the highest flow
120a Hf =
rate the pump will be delivering.
120h
If the calculated "H" is positive, the pump can operate at a
suction lift of maximum "H" m head.
TM069670
26
CR, CRI, CRN
9
Selection
tm Hv
(°C) (m)
190 126
180 100
170 79
Hf
160 62
150 45
40
140 35
30
H 130
Pb NPSH 25
120 20
110 15
Hv 12
100 10
8,0
90
6,0
80 5,0
4,0
70 3,0
60 2,0
1,5
50
1,0
40 0,8
0,6
30 0,4
0,3
20
0,2
TM027439
10
0,1
0
27
9 CR, CRI, CRN
Selection
220 -11
-11-2
2.0
200 -10
-10-2
180 -9
2 -9-2 3
1.6 160 -8
-8-2
140 -7
-7-2
1.2 120 -6
-6-2
100 -5
-5-2
0.8 80 -4
-4-2
60 -3
-3-2
0.4 40 -2
-2-2
20 -1
-1-1
0.0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
0 2 4 6 8 10 Q [l/s] 5
P2 P2 Eta
[hp] [kW] [%]
2.0 Eta 80
2.4 P2 1/1
1.5 60
P2 2/3
1.6
4 1.0 40
0.8 0.5 20
0.0 0.0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
p H NPSH
[kPa] [m] [m]
200 20 QH 2900 rpm 1/1 8
160
15
QH 2900 rpm 2/3
6
7
6 120
10 4
80
TM078855
5 NPSH 2
40
0 0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
Pos. Description
1 Pump type. Frequency, poles or speed. ISO or ANSI standard.
2 Number of stages. First figure: number of stages. Second figure: number of reduced-diameter impellers.
3 QH curve for the individual pump. The bold curves indicate the recommended duty range for best efficiency.
4 The power curves indicate pump input power per stage. Curves are shown for full (1/1) and for reduced-diameter (2/3) impellers.
The eta curve shows the efficiency of a pump with an average number of stages. The efficiency of pumps with reduced-diameter impellers
5
is approximately 2 % lower than the eta curve shown in the chart.
6 QH curve for each individual impeller. Curves are shown for full (1/1) and for reduced-diameter (2/3) impellers.
7 The NPSH curve is a maximum curve for all the variants shown.
28
CR, CRI, CRN
9
Selection
The guidelines below apply to the performance curves:
• Tolerances to ISO 9906:2012, Grade 3B, if indicated
on the curve chart.
• The motors used for the measurements are standard
Grundfos MG motors.
• Measurements have been made with airless water at
a temperature of 20 °C.
• The curves apply to the following kinematic viscosity: υ
= 1 mm2/s (1 cSt).
• Due to the risk of overheating, the pumps must not be
used at a flow rate below the minimum flow rate.
• The QH curves apply to a rated motor speed of a
three-phase mains-operated motor. For realistic
curves, go to Grundfos Product Center (http://product-
selection.grundfos.com/), and insert data.
The curve below shows the minimum flow rate as a
percentage of the rated flow rate in relation to the liquid
temperature. The dotted line shows a CR pump fitted with
an air-cooled top assembly.
Qm in
[ %]
30
20
10
TM012816
0
40 60 80 100 120 140 160 180 t [° C]
29
10 CR, CRI, CRN
Performance curves and technical data
CR 1s
p H
[kPa] [m]
CR 1s
220
50 Hz
-36 ISO 9906:2012 Grade 3B
2000
200
-33
180
-30
1600
160 -27
140 -25
-23
0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Q [m³/h]
40 4 4
20 2 NPSH 2
TM027424
0 0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Q [m³/h]
30
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2
FGJ(DIN-ANSI-JIS)
PN 25 / DN 25/32 A
B1
G 1/2 19 x 24.5
G 1/2 Rp 1
22 M10 x 40
ø100
ø140
ø89
75
50
20
20
100 ø35 4 x ø13.5 100 75 4 x ø13.5
TM069591
141 180 145 180
250 220 160 220
31
10 CR, CRI, CRN
CRI, CRN 1s
Performance curves and technical data
p H
[kPa] [m]
CRI, CRN 1s
220
50 Hz
-36 ISO 9906:2012 Grade 3B
2000
200
-33
180
-30
1600
160 -27
140 -25
-23
0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Q [m³/h]
40 4 4
20 2 NPSH 2
TM027425
0 0 0
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Q [m³/h]
32
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2
FGJ(DIN-ANSI-JIS)
P(PJE) PN 25 / DN 25/32 CA
B1
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
ø59
75
50
50
TM069592
ø42.2
22
34
22
33
10 CR, CRI, CRN
CR 1
Performance curves and technical data
p H
[kPa] [m]
-36 CR 1
220
50 Hz
-33 ISO 9906:2012 Grade 3B
2000
200
-30
180
-27
1600
160
-25
-23
140
-21
1200 120 -19
-17
100
-15
800 80 -13
-12
-11
60 -10
-9
-8
-7
400 40 -6
-5
-4
20 -3
-2
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [m³/h]
0.00 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [m³/h]
H NPSH
[m] [m]
QH 2900 rpm
6 4
3 2
NPSH
0 0
TM027290
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [m³/h]
34
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2
FGJ(DIN-ANSI-JIS)
PN 25 / DN 25/32 A
B1
G 1/2 19 x 24.5
G 1/2 Rp 1
22 M10 x 40
ø100
ø140
ø89
75
50
20
20
100 ø35 4 x ø13.5 100 75 4 x ø13.5
TM069591
141 180 145 180
250 220 160 220
35
10 CR, CRI, CRN
CRI, CRN 1
Performance curves and technical data
p H
[kPa] [m]
-36 CRI, CRN 1
220
50 Hz
-33 ISO 9906:2012 Grade 3B
2000
200
-30
180
-27
1600
160
-25
-23
140
-21
1200 120 -19
-17
100
-15
800 80 -13
-12
-11
60 -10
-9
-8
-7
400 40 -6
-5
-4
20 -3
-2
0 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [m³/h]
0.00 0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [m³/h]
H NPSH
[m] [m]
QH 2900 rpm
6 4
3 2
NPSH
0 0
TM027291
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 Q [m³/h]
36
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2
FGJ(DIN-ANSI-JIS)
P(PJE) PN 25 / DN 25/32 CA
B1
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
ø59
75
50
50
TM069592
ø42.2
22
34
22
37
10 CR, CRI, CRN
CR 3
Performance curves and technical data
p H
[kPa] [m]
CR 3
240 -36
50 Hz
ISO 9906:2012 Grade 3B
220
-33
2000 -31
200
-29
180 -27
1600 -25
160
-23
140
-21
-19
1200 120
-17
100 -15
800 -13
80 -12
-11
-10
60 -9
-8
-7
400 40 -6
-5
-4
20 -3
-2
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]
0.03 20
0.00 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]
H NPSH
[m] QH 2900 rpm [m]
6 6
4 4
2 NPSH 2
0 0
TM027292
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]
38
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2
FGJ(DIN-ANSI-JIS)
PN 25 / DN 25/32 A
B1
G 1/2 19 x 24.5
G 1/2 Rp 1
22 M10 x 40
ø100
ø140
ø89
75
50
20
20
100 ø35 4 x ø13.5 100 75 4 x ø13.5
TM069591
141 180 145 180
250 220 160 220
39
10 CR, CRI, CRN
CRI, CRN 3
Performance curves and technical data
p H
[kPa] [m]
CRI, CRN 3
240 -36
50 Hz
ISO 9906:2012 Grade 3B
220
-33
2000 -31
200
-29
180 -27
1600 -25
160
-23
140
-21
-19
1200 120
-17
100 -15
800 -13
80 -12
-11
-10
60 -9
-8
-7
400 40 -6
-5
-4
20 -3
-2
0 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]
0.03 20
0.00 0
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]
H NPSH
[m] QH 2900 rpm [m]
6 3
4 2
NPSH
2 1
0 0
TM027293
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]
40
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2
FGJ(DIN-ANSI-JIS)
P(PJE) PN 25 / DN 25/32 CA
B1
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
ø59
75
50
50
TM069592
ø42.2
22
34
22
41
10 CR, CRI, CRN
CR 5
Performance curves and technical data
p H
[kPa] [m]
260
CR 5
-36 50 Hz
2400
240 ISO 9906:2012 Grade 3B
220
-32
2000 -29
200
180
-26
-24
1600 160
-22
140 -20
0 0
0 1 2 3 4 5 6 7 8 Q [m³/h]
P2
0.10 40
0.05 20
0.00 0
0 1 2 3 4 5 6 7 8 Q [m³/h]
H NPSH
[m] QH 2900 rpm [m]
6 6
4 4
2 NPSH 2
TM027294
0 0
0 1 2 3 4 5 6 7 8 Q [m³/h]
42
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2
D3
FGJ (DIN-ANSI-JIS) A
PN 25 / DN 25/32
B1
G 1/2 19 x 24.5
G 1/2 Rp 1 1/4"
ø100 22 M10 x 40
ø140
ø89
75
20
50
TM069593
20
43
10 CR, CRI, CRN
CRI, CRN 5
Performance curves and technical data
p H
[kPa] [m]
260
CRI, CRN 5
-36 50 Hz
2400
240 ISO 9906:2012 Grade 3B
220
-32
2000 -29
200
180
-26
-24
1600 160
-22
140 -20
0 0
0 1 2 3 4 5 6 7 8 Q [m³/h]
P2
0.10 40
0.05 20
0.00 0
0 1 2 3 4 5 6 7 8 Q [m³/h]
H NPSH
[m] QH 2900 rpm [m]
6 6
4 4
2 2
NPSH
0 0
TM027295
0 1 2 3 4 5 6 7 8 Q [m³/h]
44
CR, CRI, CRN
10
Dimensional sketch
G 1/2
G 1/2
D3
FGJ (DIN-ANSI-JIS)
CA
B1
P (PJE) PN 25 / DN 25/32
ø14 19 x 27
G 1/2 4 x ø13
ø105
ø140
ø89
ø59
75
50
ø42.2
TM069594
100 180 250 ø32 162 ø32
50
34
22
22
150 210 ø85
210
45
10 CR, CRI, CRN
CR 10
Performance curves and technical data
p H
[kPa] [m]
CR 10
240
-22
50 Hz
ISO 9906:2012 Grade 3B
220
-20
2000
200
-18
180
-16
1600
160
-14
140
-12
1200 120
-10
100
-9
-8
800 80
-7
-6
60
-5
-4
400 40
-3
-2
20
-1
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0.2 40
0.1 20
0.0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
H NPSH
[m] [m]
12 6
2900 rpm
8 4
NPSH
4 2
0 0
TM027296
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
46
CR, CRI, CRN
10
Dimensional sketch
G 1/2 G 1/2 D3
FJ (DIN-JIS) A
PN 16-25 / DN 40
B1
Rp 1 1/2"
G 1/2 18 x 20.2 G 1/2
27 M16 x 45
ø39
ø150
ø114
4 x ø13.5
80
80
20
4 x ø13.5 130
20
ø110 100
TM069595
130
178 215 178 215
280 256 200 256
47
10 CR, CRI, CRN
CRI, CRN 10
Performance curves and technical data
p H
[kPa] [m]
CRI, CRN 10
240
-22
50 Hz
ISO 9906:2012 Grade 3B
220
-20
2000
200
-18
180
-16
1600
160
-14
140
-12
1200 120
-10
100
-9
-8
800 80
-7
-6
60
-5
-4
400 40
-3
-2
20
-1
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0.2 40
0.1 20
0.0 0
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
H NPSH
[m] [m]
12 6
2900 rpm
8 4
NPSH
4 2
0 0
TM027297
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
48
CR, CRI, CRN
10
Dimensional sketch
G 1/2
G 1/2 D3
FGJ (DIN-ANSI-JIS)
P (PJE) PN 16-25 / DN 40 CA
B1
18.5 x 23.5
G 1/2
G 1/2 4 x ø13 202
ø150
ø115
ø87
4 x ø13
26
80
80
80
ø60.1
26
130 130 130
26
TM069596
200 248 200 ø105 200 215
261 280 215 248
248
49
10 CR, CRI, CRN
CR 15
Performance curves and technical data
p H
[kPa] [m]
-17 CR 15
240
50 Hz
ISO 9906:2012 Grade 3B
220
2000 -14
200
180
-12
1600
160
-10
140
-9
1200 120
-8
-7
100
-6
800 80
-5
60 -4
-3
400 40
-2
20 -1
0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]
0 1 2 3 4 5 6 Q [l/s]
P2 Eta
[kW] [%]
0.8 80
P2
Eta
0.6 60
0.4 40
0.2 20
0.0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]
H NPSH
[m] [m]
15 2900 rpm 6
10 4
5 NPSH 2
0 0
TM027298
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]
50
CR, CRI, CRN
10
Dimensional sketch
G 1/2
G 1/2 D3
F (DIN)
GJ (ANSI-JIS) A
PN 16-25 / DN 50
G 1/2
B1
ø65
ø125
ø165
ø165
ø127
90
90
90
130
20
ø65 ø120
TM069597
20
20
130 130 130
176 215 215 178 215
176
300 256 256 200 256
300
51
10 CR, CRI, CRN
CRI, CRN 15
Performance curves and technical data
p H
[kPa] [m]
-17 CRI, CRN 15
240
50 Hz
ISO 9906:2012 Grade 3B
220
2000 -14
200
180
-12
1600
160
-10
140
-9
1200 120
-8
-7
100
-6
800 80
-5
60 -4
-3
400 40
-2
20 -1
0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]
0 1 2 3 4 5 6 Q [l/s]
P2 Eta
[kW] [%]
0.8 80
P2
Eta
0.6 60
0.4 40
0.2 20
0.0 0
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]
H NPSH
[m] [m]
15 2900 rpm 6
10 4
5 NPSH 2
0 0
TM027299
0 2 4 6 8 10 12 14 16 18 20 22 Q [m³/h]
52
CR, CRI, CRN
10
Dimensional sketch
G 1/2
G 1/2 D3
FGJ (DIN-ANSI-JIS)
PN 16-25 / DN 40
P (PJE) CA
B1
ø127
ø165
ø87
26
26
90
90
90
ø60.1
26
TM069598
200 248 200 ø120.5 200 215
261 300 215 248
248
53
10 CR, CRI, CRN
CR 20
Performance curves and technical data
p H
[kPa] [m]
260
CR 20
-17
50 Hz
2400
240 ISO 9906:2012 Grade 3B
220
-14
2000
200
180 -12
1600 160
-10
140
1200 120 -8
-7
100
-6
800 80 -5
60 -4
-3
400 40
-2
20 -1
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
P2 Eta
[kW] [%]
1.6 80
1.2 Eta 60
P2
0.8 40
0.4 20
0.0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
H NPSH
[m] [m]
15 2900 rpm 6
10 4
5 2
NPSH
0 0
TM027300
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
54
CR, CRI, CRN
10
Dimensional sketch
G 1/2
G 1/2 D3
F (DIN)
GJ (ANSI-JIS) A
PN 16-25 / DN 50
G 1/2
B1
ø65
ø125
ø165
ø165
ø127
90
90
90
130
20
ø65 ø120
TM069597
20
20
130 130 130
176 215 215 178 215
176
300 256 256 200 256
300
55
10 CR, CRI, CRN
CRI, CRN 20
Performance curves and technical data
p H
[kPa] [m]
260
CRI, CRN 20
-17
50 Hz
2400
240 ISO 9906:2012 Grade 3B
220
-14
2000
200
180 -12
1600 160
-10
140
1200 120 -8
-7
100
-6
800 80 -5
60 -4
-3
400 40
-2
20 -1
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
0 1 2 3 4 5 6 7 8 Q [l/s]
P2 Eta
[kW] [%]
1.6 80
1.2 Eta 60
P2
0.8 40
0.4 20
0.0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
H NPSH
[m] [m]
15 2900 rpm 6
10 4
5 NPSH 2
0 0
TM027301
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Q [m³/h]
56
CR, CRI, CRN
10
Dimensional sketch
G 1/2
G 1/2 D3
FGJ (DIN-ANSI-JIS)
PN 16-25 / DN 40
P (PJE) CA
B1
ø127
ø165
ø87
26
26
90
90
90
ø60.1
26
TM069598
200 248 200 ø120.5 200 215
261 300 215 248
248
57
10 CR, CRI, CRN
CR 32
Performance curves and technical data
p H
[MPa] [m]
280 -14
CRN 32
-14-2
50 Hz
260 -13 ISO 9906:2012 Grade 3B
-13-2
2.4
240 -12
-12-2
220 -11
-11-2
2.0
200 -10
-10-2
180 -9
-9-2
1.6 160 -8
-8-2
140 -7
-7-2
1.2 120 -6
-6-2
100 -5
-5-2
0.8 80 -4
-4-2
60 -3
-3-2
0.4 40 -2
-2-2
20 -1
-1-1
0.0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
0 2 4 6 8 10 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
2.0 Eta 80
2.4 P2 1/1
1.5 60
P2 2/3
1.6
1.0 40
0.8 0.5 20
0.0 0.0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
p H NPSH
[kPa] [m] [m]
200 20 QH 2900 rpm 1/1 8
160 QH 2900 rpm 2/3
15 6
120
10 4
80
5 NPSH 2
40
0 0 0
TM027303
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
58
CR, CRI, CRN
10
Dimensional sketch
D1
D2
D1
B2
B2 D3
G 1/2
F (DIN)
PN 16-25-40 / DN 65
B1
G 1/2
8 x ø18
G 1/2
ø107
ø145
185
30
105
ø74 4 x ø14
TM069605
170 240
223 298
320
59
10 CR, CRI, CRN
CRN 32
Performance curves and technical data
p H
[MPa] [m]
280 -14
CRN 32
-14-2
50 Hz
260 -13 ISO 9906:2012 Grade 3B
-13-2
2.4
240 -12
-12-2
220 -11
-11-2
2.0
200 -10
-10-2
180 -9
-9-2
1.6 160 -8
-8-2
140 -7
-7-2
1.2 120 -6
-6-2
100 -5
-5-2
0.8 80 -4
-4-2
60 -3
-3-2
0.4 40 -2
-2-2
20 -1
-1-1
0.0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
0 2 4 6 8 10 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
2.0 Eta 80
2.4 P2 1/1
1.5 60
P2 2/3
1.6
1.0 40
0.8 0.5 20
0.0 0.0 0
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
p H NPSH
[kPa] [m] [m]
200 20 QH 2900 rpm 1/1 8
160 QH 2900 rpm 2/3
15 6
120
10 4
80
5 NPSH 2
40
0 0 0
TM027303
0 4 8 12 16 20 24 28 32 36 Q [m³/h]
60
CR, CRI, CRN
10
Dimensional sketch
D1 D1
B2
B2
D3 D3
G 1/2
G 1/2 F (DIN)
P (PJE)
PN 16-25-40 / DN 65
B1
B1
8 x ø18
G 1/2 G 1/2
ø89
G 1/2 ø107 G 1/2
ø145
ø185
30
105
105
4 x ø14
30
TM078956
ø74 170 ø74
170
4 x ø14
226 240 226 240
320 298
320 298
61
10 CR, CRI, CRN
CR 45
Performance curves and technical data
p H
[MPa] [m]
340 CR 45
-13-2
3.2 50 Hz
320
-12 ISO 9906:2012 Grade 3B
-12-2
300
2.8 -11
280 -11-2
260 -10
-10-2
2.4
240
-9
-9-2
220
-8
2.0 200 -8-2
180 -7
-7-2
1.6 160
-6
-6-2
140
-5
1.2 120 -5-2
-4
100
-4-2
0.8 80 -3
-3-2
60
-2
0.4 40 -2-2
-1
20 -1-1
0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
0 2 4 6 8 10 12 14 16 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
4 Eta 80
P2 1/1
4 3 60
P2 2/3
2 40
2
1 20
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
p H NPSH
[kPa] [m] [m]
QH 2900 rpm 1/1
25 10
QH 2900 rpm 2/3
200 20 8
150 15 6
100 10 4
50 5 NPSH 2
0 0 0
TM027304
0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
62
CR, CRI, CRN
10
Dimensional sketch
B2
D3
G 1/2
F (DIN)
PN 16-25-40 / DN 80
B1
G 1/2 8 x ø18
G 1/2
ø120
ø160
ø200
45
140
TM069600
190 ø80 4 x ø14
248 266
365 331
63
10 CR, CRI, CRN
CRN 45
Performance curves and technical data
p H
[MPa] [m]
340 CRN 45
-13-2
3.2 50 Hz
320
-12 ISO 9906:2012 Grade 3B
-12-2
300
2.8 -11
280 -11-2
260 -10
-10-2
2.4
240
-9
-9-2
220
-8
2.0 200 -8-2
180 -7
-7-2
1.6 160
-6
-6-2
140
-5
1.2 120 -5-2
-4
100
-4-2
0.8 80 -3
-3-2
60
-2
0.4 40 -2-2
-1
20 -1-1
0.0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
0 2 4 6 8 10 12 14 16 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
4 Eta 80
P2 1/1
4 3 60
P2 2/3
2 40
2
1 20
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
p H NPSH
[kPa] [m] [m]
QH 2900 rpm 1/1
25 10
QH 2900 rpm 2/3
200 20 8
150 15 6
100 10 4
50 5 NPSH 2
0 0 0
TM027305
0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
64
CR, CRI, CRN
10
Dimensional sketch
B2
B2
P D3
G 1/2 G 1/2
F (DIN)
P (PJE) PN 16-25-40 / DN 80
B1
B1
G 1/2 8 x ø18
G 1/2
ø114
G 1/2
G 1/2
ø120
ø200
ø160
45
140
140
45
4 x ø14
TM078957
251 266 251 266
365 331 365 331
65
10 CR, CRI, CRN
CR 64
Performance curves and technical data
p H
[MPa] [m]
CR 64
240
-8-1
50 Hz
-8-2 ISO 9906:2012 Grade 3B
220
-7
2.0
200 -7-1
-7-2
180 -6
-6-1
1.6 160 -6-2
-5
140 -5-1
-5-2
1.2 120 -4
-4-1
100 -4-2
-3
0.8 80 -3-1
-3-2
60 -2
-2-1
0.4 40 -2-2
-1
20 -1-1
0.0 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
0 5 10 15 20 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
8 80
10 Eta
8 6 P2 1/1 60
6 4 P2 2/3 40
4
2 20
2
0 0 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
p H NPSH
[kPa] [m] [m]
300 32 8
QH 2900 rpm 1/1
24 6
200 QH 2900 rpm 2/3
16 4
100 NPSH
8 2
0 0 0
TM027306
0 10 20 30 40 50 60 70 80 Q [m³/h]
66
CR, CRI, CRN
10
Dimensional sketch
F (DIN)
PN 25-40 / DN 100
8 x ø 22
B2
G 1/2
ø150
ø190
ø235
ø100 4 x ø 14
D3
45
266
331
G 1/2
F (DIN)
PN 16 / DN 100
G 1/2
B1
8 x ø 18
G 1/2
ø150
ø180
ø220
140
ø100 4 x ø 14
TM069606
45
190
248 266
365 331
67
10 CR, CRI, CRN
CRN 64
Performance curves and technical data
p H
[MPa] [m]
CRN 64
240
-8-1
50 Hz
-8-2 ISO 9906:2012 Grade 3B
220
-7
2.0
200 -7-1
-7-2
180 -6
-6-1
1.6 160 -6-2
-5
140 -5-1
-5-2
1.2 120 -4
-4-1
100 -4-2
-3
0.8 80 -3-1
-3-2
60 -2
-2-1
0.4 40 -2-2
-1
20 -1-1
0.0 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
0 5 10 15 20 Q [l/s]
P2 P2 Eta
[hp] [kW] [%]
8 80
10 Eta
8 6 P2 1/1 60
6 4 P2 2/3 40
4
2 20
2
0 0 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
p H NPSH
[kPa] [m] [m]
300 32 8
QH 2900 rpm 1/1
24 6
200 QH 2900 rpm 2/3
16 4
100 NPSH
8 2
0 0 0
TM027307
0 10 20 30 40 50 60 70 80 Q [m³/h]
68
CR, CRI, CRN
10
Dimensional sketch
F (DIN)
PN 25-40 / DN 100
8 x ø22
B2
B2
G 1/2
ø235
ø190
ø150
P D3 ø100 4 x ø14
45
266
G 1/2 G 1/2 331
P (PJE) F (DIN)
PN 16 / DN 100
B1
G 1/2
B1
G 1/2 8 x ø18
ø114
G 1/2
G 1/2
ø150
ø180
ø220
45
45
140
140
190 ø80 ø100 4 x ø14
TM078958
4 x ø14 190
251 266 251 266
365 331 365 331
69
10 CR, CRI, CRN
CR 95
Performance curves and technical data
p H
[MPa] [m]
240 -8-2 CR 95
230
2.2 -7 50 Hz
220
ISO 9906:2012 Grade 3B
210
2.0
200
190 -6
1.8
180
170
1.6
160 -5
150
1.4 140
130 -4
1.2 120
110
1.0 100 -3
90
0.8 -3-2
80
70
-2
0.6 60
-2-2
50
0.4 40
-1
30 -1-1
0.2 20
10
0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
0 5 10 15 20 25 30 35 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
16 80
12 60
4 20
P22/3 IS 2950 rpm
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
H NPSH
[m] [m]
QH1/1 IS 2950 rpm
30 6
QH2/3 IS 2950 rpm
20 4
NPSH 2950 rpm
10 2
TM065113
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
The pump efficiency (ETA) is based on a three-stage pump.
70
CR, CRI, CRN
10
Dimensional sketch
D3
G 1/2 G 1/2
8x 18 8x 22 8x 22
G 1/2
G 1/2
150
180
220
150
190
235
150
190
235
4x 18.5 4x 18.5 4x 18.5
140
TM080551
225 100 100
40
100
40
40
275 350 350 350
380 419 419 419
71
10 CR, CRI, CRN
CRN 95
Performance curves and technical data
p H
[MPa] [m]
240 -8-2 CRN 95
230
2.2 -7
50 Hz
220
ISO 9906:2012 Grade 3B
210
2.0
200
190 -6
1.8
180
170
1.6
160 -5
150
1.4 140
130 -4
1.2 120
110
1.0 100
-3
90
0.8 -3-2
80
70
-2
0.6 60
-2-2
50
0.4 40
-1
30 -1-1
0.2 20
10
0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
0 5 10 15 20 25 30 35 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
16 80
12 60
4 20
P22/3 IS 2950 rpm
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
H NPSH
[m] [m]
QH1/1 IS 2950 rpm
30 6
QH2/3 IS 2950 rpm
20 4
NPSH 2950 rpm
10 2
TM065125
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
The pump efficiency (ETA) is based on a three-stage pump.
72
CR, CRI, CRN
10
Dimensional sketch
D1 D4
P (PJE) P (PJE)
B2
G 1/2 G 1/2
4x 18.5
14 0
D3 225 100
40
40
275 350
G 1/2 G 1/2 380 419
8x 18 8x 22 8x 22
G 1/2
G 1/2
150
190
235
150
190
235
150
180
220
TM065094
225 100 100 100
40
40
40
275 350 350 350
380 419 419 41 9
73
10 CR, CRI, CRN
CR 125
Performance curves and technical data
p H
[MPa] [m]
180 CR 125
170 -5 50 Hz
1.6 ISO 9906:2012 Grade 3B
160
150
1.4
140
-4
130
1.2
120 -4-2
110
1.0 -3
100
-3-1
90
0.8 80
70 -2
0.6 60 -2-1
-2-2
50
0.4 40
-1
30
0.2 20
10
0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
0 5 10 15 20 25 30 35 40 45 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
16 80
4 20
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
H NPSH
[m] [m]
40 8
QH1/1 IS 2950 rpm
30 6
QH2/3 IS 2950 rpm
20 4
NPSH 2950 rpm
10 2
TM065114
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
The pump efficiency (ETA) is based on a three-stage pump.
74
CR, CRI, CRN
10
Dimensional sketch
D3
G 1/2 G 1/2
8x 22 8x 26 8x 26
G 1/2 G 1/2
205
240
285
205
250
300
205
250
300
4x 22.5 4x 22.5 4x 22.5
180
TM080549
275 150 150 150
55
55
55
332 425 425 425
485 499 499 499
75
10 CR, CRI, CRN
CRN 125
Performance curves and technical data
p H
[MPa] [m]
340 -10 CRN 125
320 50 Hz
ISO 9906:2012 Grade 3B
3.0 -9
300
-9-2
280
-8
260
2.5
240 -7
220
2.0 -6
200
180
-5
160
1.5
140 -4
120 -4-2
1.0 -3
100
-3-1
80
-2
60 -2-1
0.5
40 -2-2
-1
20
0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
0 5 10 15 20 25 30 35 40 45 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
16 80
4 20
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
H NPSH
[m] [m]
40 8
QH1/1 IS 2950 rpm
30 6
QH2/3 IS 2950 rpm
20 4
NPSH 2950 rpm
10 2
TM065126
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]
The pump efficiency (ETA) is based on a three-stage pump.
76
CR, CRI, CRN
10
Dimensional sketch
P (PJE) P (PJE)
B2
G 1/2 G 1/2
4x 22.5
180
275 150
D3
45
45
332 425
485 499
G 1/2 G 1/2
PN 25 / DN 150 PN 40 / DN 150
8x 22 8x 26 8x 26
G 1/2
G 1/2
205
240
285
205
250
300
205
250
300
4x 22.5 4x 22.5 4x 22.5
180
TM080550
275 150 150 150
55
55
55
77
10 CR, CRI, CRN
CR 155
Performance curves and technical data
p H
[MPa] [m]
150 CR 155
1.4 -4-1 50 Hz
140
ISO 9906:2012 Grade 3B
130
1.2
120
-3
110
1.0
100 -3-2
90
0.8 80
-2
70
0.6 -2-2
60
50
0.4 40 -1
-1-1
30
0.2 20
10
0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Q [m³/h]
0 5 10 15 20 25 30 35 40 45 50 55 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
20 80
15 60
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Q [m³/h]
H NPSH
[m] [m]
50 10
40 QH1/1 IS 2950 rpm 8
30 6
QH2/3 IS 2950 rpm
20 4
NPSH 2950 rpm
10 2
TM065115
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Q [m³/h]
The pump efficiency (ETA) is based on a three-stage pump.
78
CR, CRI, CRN
10
Dimensional sketch
D3
G 1/2 G 1/2
8x 22 8x 26 8x 26
G 1/2 G 1/2
205
240
285
205
250
300
205
250
300
4x 22.5 4x 22.5 4x 22.5
180
TM080549
275 150 150 150
55
55
55
332 425 425 425
485 499 499 499
79
10 CR, CRI, CRN
CRN 155
Performance curves and technical data
p H
[MPa] [m]
3.0
300 CRN 155
-8-2 50 Hz
280
ISO 9906:2012 Grade 3B
-7
260
2.5
240
-6
220
2.0
200
-5
180 -5-2
160
1.5
-4-1
140
120 -3
80 -2
-2-2
60
0.5
40 -1
-1-1
20
0.0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Q [m³/h]
0 5 10 15 20 25 30 35 40 45 50 55 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
20 80
15 60
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Q [m³/h]
H NPSH
[m] [m]
50 10
40 QH1/1 IS 2950 rpm 8
30 6
QH2/3 IS 2950 rpm
20 4
NPSH 2950 rpm
10 2
TM065127
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Q [m³/h]
The pump efficiency (ETA) is based on a three-stage pump.
80
CR, CRI, CRN
10
Dimensional sketch
P (PJE) P (PJE)
B2
G 1/2 G 1/2
4x 22.5
180
275 150
D3
45
45
332 425
485 499
G 1/2 G 1/2
PN 25 / DN 150 PN 40 / DN 150
8x 22 8x 26 8x 26
G 1/2
G 1/2
205
240
285
205
250
300
205
250
300
4x 22.5 4x 22.5 4x 22.5
180
TM080550
275 150 150 150
55
55
55
81
10 CR, CRI, CRN
CR 185
Performance curves and technical data
TM065116
82
CR, CRI, CRN
10
Dimensional sketch
D3
G 1/2 G 1/2
12 x 22 12 x 27 12 x 30
G 1/2 G 1/2
260
295
340
260
310
360
260
320
375
4 x 26.5 4 x 26.5 4 x 26.5
200
TM076604
350 200 200 200
50
50
50
83
10 CR, CRI, CRN
CRN 185
Performance curves and technical data
TM065128
84
CR, CRI, CRN
10
Dimensional sketch
P (PJE) P (PJE)
B2
G 1/2 G 1/2
4x 26.5
200
D3 350 200
50
50
415 510
615 599
G 1/2 G 1/2
12 x 22 12 x 27 12 x 30
G 1/2
G 1/2
260
295
340
260
310
360
260
320
375
4x 26.5 4 x 26.5 4 x 26.5
200
TM076605
350 200 200 200
50
50
50
85
10 CR, CRI, CRN
CR 215
Performance curves and technical data
TM065117
86
CR, CRI, CRN
10
Dimensional sketch
D3
G 1/2 G 1/2
8x 22 8x 26 8x 26
G 1/2 G 1/2
205
240
285
205
250
300
205
250
300
4x 22.5 4x 22.5 4x 22.5
180
TM080549
275 150 150 150
55
55
55
332 425 425 425
485 499 499 499
87
10 CR, CRI, CRN
CRN 215
Performance curves and technical data
TM065129
88
CR, CRI, CRN
10
Dimensional sketch
P (PJE) P (PJE)
B2
G 1/2 G 1/2
4x 22.5
180
275 150
D3
45
45
332 425
485 499
G 1/2 G 1/2
PN 25 / DN 150 PN 40 / DN 150
8x 22 8x 26 8x 26
G 1/2
G 1/2
205
240
285
205
250
300
205
250
300
4x 22.5 4x 22.5 4x 22.5
180
TM080550
275 150 150 150
55
55
55
89
10 CR, CRI, CRN
CR 255
Performance curves and technical data
p H
[MPa] [m]
3.0
300 CR 255
50 Hz
280
-6-2
260
2.5
240 -5
220
-5-3
2.0
200
-4
180
-4-2
160
1.5
-3
140
-3-2
120
1.0 100
-2
80 -2-2
60
0.5 -1
40
-1-1
20
0.0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [m³/h]
0 10 20 30 40 50 60 70 80 90 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
40 80
10 20
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [m³/h]
H NPSH
[m] [m]
60 12
QH1/1 IS 2950 rpm
40 8
QH2/3 IS 2950 rpm
20 NPSH 2950 rpm 4
TM065118
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [m³/h]
90
CR, CRI, CRN
10
Dimensional sketch
D3
G 1/2 G 1/2
12 x 22 12 x 27 12 x 30
G 1/2 G 1/2
260
295
340
260
310
360
260
320
375
4 x 26.5 4 x 26.5 4 x 26.5
200
TM076604
350 200 200 200
50
50
50
91
10 CR, CRI, CRN
CRN 255
Performance curves and technical data
p H
[MPa] [m]
3.0
300 CRN 255
50 Hz
280
-6-2
260
2.5
240 -5
220
-5-3
2.0
200
-4
180
-4-2
160
1.5
-3
140
-3-2
120
1.0 100
-2
80 -2-2
60
0.5 -1
40
-1-1
20
0.0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [m³/h]
0 10 20 30 40 50 60 70 80 90 Q [l/s]
P2 Eta
[kW] Eta 2950 rpm [%]
40 80
10 20
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [m³/h]
H NPSH
[m] [m]
60 12
QH1/1 IS 2950 rpm
40 8
QH2/3 IS 2950 rpm
20 NPSH 2950 rpm 4
TM065130
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320Q [m³/h]
92
CR, CRI, CRN
10
Dimensional sketch
D3
G 1/2 G 1/2
12 x 22 12 x 27 12 x 30
G 1/2 G 1/2
260
295
340
260
310
360
260
320
375
4 x 26.5 4 x 26.5 4 x 26.5
200
TM076604
350 200 200 200
50
50
50
93
11 CR, CRI, CRN
Electrical data
MG
TM031711
Motor Frame Standard voltage Full-load current Power factor Efficiency Motor eff. Starting current Speed
P2 [kW] size [V] I1/1 [A] Cos φ1/1 class η [%] Istart [%] [rpm]
0.371) 71A 220-240Δ/380-415Y 1.74 / 1.00 0.80 - 0.70 IE3 73.8 490-530 2850-2880
0.551) 71B 220-240Δ/380-415Y 2.50 / 1.44 0.80 - 0.70 IE3 77.8 580-620 2830-2850
0.751) 80A 220-240Δ/380-415Y 3.30 / 1.90 0.81 - 0.71 IE3 80.7 580-620 2840-2870
1.11) 80C 220-240Δ/380-415Y 4.35 / 2.50 0.83 - 0.76 IE3 82.7 450-500 2840-2870
1.51) 90SD 220-240Δ/380-415Y 5.70 / 3.30 0.84 - 0.78 IE3 84.2 750-820 2890-2910
2.21) 90LE 380-415Δ 4.65 0.86 - 0.80 IE3 85.9 840-920 2890-2910
31) 100LC 380-415Δ 6.30 0.87 - 0.82 IE3 87.1 840-920 2900-2920
5.52) 132SC 380-415Δ 11.00 0.87 - 0.82 IE3 89.2 1080-1180 2920-2940
7.52) 132SB 380-415Δ/660-690Y 14.4 - 14 / 8.3 - 8.1 0.88 - 0.82 IE3 90.1 780-910 2910-2920
112) 160MB 380-415Δ/660-690Y 20.8 - 19.8 / 12 - 11.8 0.88 - 0.84 IE3 91.2 660-780 2940-2950
152) 160MD 380-415Δ/660-690Y 28-26 / 16.2 - 15.6 0.89 - 0.87 IE3 91.9 660-780 2930-2950
18.52) 160LB 380-415Δ/660-690Y 34.5 - 32.5 / 20 - 18.8 0.89 - 0.85 IE3 92.4 830-980 2940-2950
222) 180MB 380-415Δ/660-690Y 39.5 / 22.8 0.90 IE3 92.7 830 2950
Siemens
TM031710
302) 200L 380-420Δ/660-725Y 53-51 / 31 - 29.5 0.87 IE3 93.3 700 2955
372) 200L 380-420Δ/660-725Y 65-63 / 37.5 - 36 0.88 IE3 93.7 710 2955
552) 250M 380-420Δ/660-725Y 95-90 / 55-52 0.89 IE3 94.3 670 2975
751) 280S 380-420Δ/660-725Y 128-125 / 74-72 0.89 IE3 94.7 680 2975
1101) 315S 380-420Δ/660-725Y 183-176 / 106-102 0.91 IE3 95.2 710 2982
1321) 315M 380-420Δ/660-725Y 220-210 / 127-121 0.91 IE3 95.4 720 2982
1601) 315L 380-420Δ/660-725Y 265-255 / 152-147 0.92 IE3 95.6 780 2982
2001) 315L 380-420Δ/660-725Y 330-310 / 190-179 0.92 IE3 95.8 720 2982
94
CR, CRI, CRN
12
Therefore, use the list with some caution. Factors such as H Risk of crystallisation/precipitation in shaft seal.
those mentioned below may affect the chemical 1 Highly flammable liquid.
resistance of a specific pump version: 2 Combustible liquid.
• concentration of the pumped liquid 3 Insoluble in water.
• pressure.
Take safety precautions when pumping dangerous liquids.
95
12 CR, CRI, CRN
96
CR, CRI, CRN
13
Accessories
13. Accessories
Pipe connection
Various sets of counterflanges and couplings are available for pipe connection.
Counterflanges for CR
A set consists of one counterflange, one gasket, bolts and nuts.
Product
Counterflange Pump type Description Rated pressure Pipe connection
number
Threaded 16 bar, EN 1092-2 Rp 1 409901
CR 1s
CR 1
TM050998
16 bar 25 bar
CR 1s
CR 1
TM051003
16 bar 25 bar
CR 10
TM051002
97
13 CR, CRI, CRN
Product
Accessories
TM050999
CR 15
Threaded 16 bar, special flange Rp 2 1/2 * 96509578
CR 20
TM051005
CR 45
TM050996
CR 64
For welding 25 bar, EN 1092-2 100 mm, nominal 369905
CR 95
TM065157
150 150 For welding 25/40 bar, EN 1092-2 100 mm, nominal 99432755
98
CR, CRI, CRN
13
Accessories
Product
Counterflange Pump type Description Rated pressure Pipe connection
number
For welding 16 bar, EN 1563 150 mm, nominal 99432761
ø26 ø22
CR 125
ø205 ø205 CR 155 For welding 25/40 bar, EN 1563 150 mm, nominal 99432760
ø250 ø240
ø300 ø285
CR 185
CR 215
ø260 ø260 ø260
ø295 ø310 ø320 CR 255 For welding 40 bar, EN 1563 200 mm, nominal 97521269
ø340 ø360 ø375
* Flange with 20 mm higher collar. With this collar, the installation dimensions of a CR 20 will be identical to those of a CR 32. If a CR 32 is replaced by a
CR 20, the base must be raised by 15 mm.
99
13 CR, CRI, CRN
Counterflanges for CRN pumps are made of stainless steel EN 1.4401 (≈AISI 316).
A set consists of one counterflange, one gasket, bolts and nuts.
Product
Counterflange Pump type Description Rated pressure Pipe connection
number
Threaded 16 bar, EN 1092-1 Rp 1 405284
CRN 1s
CRN 1
TM050998
CRN 3 For welding 25 bar, EN 1092-1 25 mm, nominal 405285
CRN 5
16 bar 25 bar
CRN 1s
CRN 1
TM051003
16 bar 25 bar
CRN 10
100
CR, CRI, CRN
13
Accessories
Product
Counterflange Pump type Description Rated pressure Pipe connection
number
TM050999
Threaded 16 bar, special flange Rp 2 1/2 96509575
TM051005
CRN 15
ø19
CRN 20
ø102
ø125
ø165
19.5
ø127
TM027203
ø102
ø125
ø165
CRN 32
CRN 45
TM050996
CRN 64
For welding 40 bar 100 mm, nominal 369906
101
13 CR, CRI, CRN
Product
Accessories
CRN 95
TM065157
150 150 For welding 25/40 bar, EN 1.4408 100 mm, nominal 99432732
CRN 125
ø205 ø205 CRN 155 For welding 25/40 bar, EN 1.4408 150 mm, nominal 99432734
ø250 ø240
ø300 ø285
CRN 185
CRN 215
ø260 ø260 ø260
ø295 ø310 ø320 CRN 255 For welding 40 bar, EN 1.4408 200 mm, nominal 99432737
ø340 ø360 ø375
102
CR, CRI, CRN
13
PJE couplings for CRN
Accessories
Materials in contact with the pumped liquid are made of
stainless steel EN 1.4401 (≈AISI 316) and rubber.
A set consists of two coupling halves (Victaulic type 77),
one gasket, one pipe stub (for welding or threaded), bolts
and nuts.
Number of
Maximum Pipe Rubber Product
Coupling Pump type Pipe stub A B coupling sets
pressure [bar] connection parts number
required
EPDM 2 419911
CRN 1s Threaded 69 50 320 R 1 1/4
CRN 1 FKM 2 419905
CRN 3 EPDM 2 419912
CRN 5 For welding 69 50 280 DN 32
FKM 2 419904
EPDM 2 339911
CRN 10 Threaded 69 80 377 R2
A FKM 2 339918
CRN 15
B EPDM 2 339910
CRN 20 For welding 69 80 371 DN 50
FKM 2 339917
EPDM 2 98144746
CRN 32 For welding 69 105 420 DN 80
FKM 2 98144749
103
13 CR, CRI, CRN
Accessories
Number of
Pipe Product
Base connection Pump type Connection PN A B Rubber parts coupling sets
connection number
required
Oval Rp 1 1 96449748
(cast iron) Rp 1 1/4 1 96449749
CRI Rp 1 2 96449746
CRN 16 50 210 Klingersil
1s, 1, 3, 5 Oval
A
(stainless steel) Rp 1 1/4 2 96449747
B
EPDM 2 96449743
CRI
CRN Union G2 25 50 228
FKM 2 96449744
1s, 1, 3, 5
A
B
EPDM 2 96449745
CRI
DIN DN 25
CRN 16 75 250
(stainless steel) DN 32 FKM 2 96449900
1s, 1, 3, 5
A
B
EPDM 2 405280
Rp 1
FKM 2 405281
EPDM 2 415296
Rp 1 1/4
Clamp, threaded FKM 2 415297
208
pipe stub EPDM 2 405291
CRI 1" NPT
FKM 2 405292
CRN 25 50
EPDM 2 415311
1s, 1, 3, 5 1 1/4" NPT
A
FKM 2 415312
B
EPDM 2 405282
28.5
Clamp, pipe stub FKM 2 405283
-
for welding EPDM 2 415300
37.2
FKM 2 415301
104
CR, CRI, CRN
13
Accessories
Number of
Pipe Product
Base connection Pump type Connection PN A B Rubber parts coupling sets
connection number
required
Rp 1 1/4 2 96498775
Oval
Rp 1 1/2 2 96498727
(cast iron)
Rp 2 2 96498836
CRI 10
Rp 1 1/4 16 80 260 Klingersil 2 96498776
CRN 10
A Oval Rp 1 1/2 2 96498728
B (stainless steel)
Rp 2 2 96498835
EPDM 2 96500275
CRI 10
Union G 2 3/4 25 80 288
CRN 10 FKM 2 96500276
A
B
105
13 CR, CRI, CRN
Accessories
Number of
Pipe Product
Base connection Pump type Connection PN A B Rubber parts coupling sets
connection number
required
Rp 1 1/4 2 96498775
Oval
Rp 1 1/2 2 96498727
(cast iron)
Rp 2 2 96498836
CRI 15, 20
Rp 1 1/4 10 90 260 Klingersil 2 96498776
CRN 15, 20
A Oval Rp 1 1/2 2 96498728
B (stainless steel)
Rp 2 2 96498835
EPDM 2 96500275
CRI 15, 20
Union G 2 3/4 25 90 288
CRN 15, 20 FKM 2 96500276
A
B
106
CR, CRI, CRN
13
LiqTec
Accessories
The LiqTec dry-running protection unit protects the pump
and process against dry running and temperatures
exceeding 130 ± 5 °C. Connected to the motor PTC
sensor, LiqTec also monitors the motor temperature.
LiqTec is prepared for DIN rail mounting in control
cabinets.
Enclosure class: IPX0.
Extension
Voltage Sensor Cable Product
LiqTec unit Pump type LiqTec cable
[V] 1/2" 5m number
15 m
200-240 ● ● ● - 96556429
80-130 ● ● ● - 96556430
- - - - ● 96443676
CR
CRI
CRN
TM032108
107
13 CR, CRI, CRN
Sensors
Accessories
108
CR, CRI, CRN
14
Variants
14. Variants
The variants are available on request. Pumps
Although the Grundfos CR, CRI, CRN product range Variant Description
offers a number of pumps for different applications, For safety or height reasons, certain applications,
customers require specific pump solutions to satisfy their for instance on ships, require the pump to be
Horizontally mounted in horizontal position.
needs. See the following documents: mounted pump
For easy installation, the pump is fitted with
• Grundfos CR "Custom-built pumps" data booklet brackets that support motor and pump.
109
15 CR, CRI, CRN
Grundfos Product Center
When you select your country, you will see the menus below. Note that some menus may not be available depending on
the country.
Example: https://product-selection.grundfos.com/uk
Pos. Description
1 Products & services enables you to find products and documents by typing a product number or name into the search field.
2 Applications enables you to choose an application to see how Grundfos can help you design and optimise your system.
3 Products A-Z enables you to look through a list of all the Grundfos products.
4 Categories enables you to look for a product category.
5 Liquids enables you to find pumps designed for aggressive, flammable or other special liquids.
6 Product replacement enables you to find a suitable replacement.
7 WWW enables you to select the country, which changes the language, the available product range and the structure of the website.
8 Sizing enables you to size a product based on your application and operating conditions.
110
99301179
ECM: 1317950
07.2021
Trademarks displayed in this material, including but not limited to Grundfos, the Grundfos logo and “be think innovate” are registered trademarks owned by The Grundfos Group. All rights reserved. © 2021 Grundfos Holding A/S, all rights reserved.