ALARM 914 TO 915 (Sram Parity) : Causes and Remedies
ALARM 914 TO 915 (Sram Parity) : Causes and Remedies
ALARM 914 TO 915 (Sram Parity) : Causes and Remedies
TROUBLESHOOTING
SYSTEM ALARM
915 SRAM PARITY (2N+1)
EAX EBX ECX EDX ESI EDI EBP ESP
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX
SS DS ES FS GS TR LDTR EFLAGS VECT ERRC ERROR–ADDRESS
XXXX XXXX XXXX XXXX XXXX XXXX XXXX:XXXXXXX XXXX XXXX:XXXXXXXX
STACK(PLO)
XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX
NMIC
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX
ADRS XXXXXXXX
This value
NOTE
1 If an SRAM parity alarm occurs in a module other than the
main CPU board, the following message appears: ALM972
NMI OCCURRED IN OTHER MODULE
2 If a parity alarm occurs in a system that was kept switched
off for a long time, it is likely that the batteries have
exhausted or the backup circuit (on the main board) is
defective.
(2) Causes are faults of RAM on the main board or RAM module, or fault
of data memorized in RAM. When this alarm occurs immediately
after power is turned on, once turn off power, then turn on power while
pushing RESET and DELETE key to perform memory all clear
375
8. TROUBLESHOOTING B–62755EN/01
If parity error is not released by clearing all memory, RAM on the main
board or RAM module may be faulty. Change (4)RAM module on
main CPU board.
Set all the data again, referring to chapter 3 “data input/output”.
D RAM module mounting 1 : SRAM module (Part program editing, parameters)
position
<Main CPU board>
(1)
(10)
376