Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

ALARM 914 TO 915 (Sram Parity) : Causes and Remedies

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

B–62755EN/01 8.

TROUBLESHOOTING

8.31 Parity error of RAM module that stores part programs.


ALARM 914 TO 915
(SRAM PARITY)
Causes and Remedies (1) If a parity alarm occurs, the following message appears on the screen.
The value at the right of “ADRS” in the lower left section of the screen
is the address (in hexadecimal) of the alarm. This value can be used
to locate the RAM chip in which a failure occurred.

SYSTEM ALARM
915 SRAM PARITY (2N+1)
EAX EBX ECX EDX ESI EDI EBP ESP
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX
SS DS ES FS GS TR LDTR EFLAGS VECT ERRC ERROR–ADDRESS
XXXX XXXX XXXX XXXX XXXX XXXX XXXX:XXXXXXX XXXX XXXX:XXXXXXXX
STACK(PLO)
XXXX XXXX XXXX XXXX XXXX XXXX XXXX XXXX

NMIC
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX

ADRS XXXXXXXX

This value

(a) If the address falls in a range of 0F1000H to 0F5FFFH, 740000H


to 77FFFFH, or 7C0000H to 7FFFFFH:
FROM/SRAM module
A20B–2902–0341, 0343
A20B–2902–0410, 0411
(b) If the address falls in a range of 700000H to 73FFFFH, 780000H
to 7BFFFFH, or 400000H to 5FFFFFH:
SRAM module
A20B–2902–0350, 0351, 0352

NOTE
1 If an SRAM parity alarm occurs in a module other than the
main CPU board, the following message appears: ALM972
NMI OCCURRED IN OTHER MODULE
2 If a parity alarm occurs in a system that was kept switched
off for a long time, it is likely that the batteries have
exhausted or the backup circuit (on the main board) is
defective.

(2) Causes are faults of RAM on the main board or RAM module, or fault
of data memorized in RAM. When this alarm occurs immediately
after power is turned on, once turn off power, then turn on power while
pushing RESET and DELETE key to perform memory all clear

375
8. TROUBLESHOOTING B–62755EN/01

If parity error is not released by clearing all memory, RAM on the main
board or RAM module may be faulty. Change (4)RAM module on
main CPU board.
Set all the data again, referring to chapter 3 “data input/output”.
D RAM module mounting 1 : SRAM module (Part program editing, parameters)
position
<Main CPU board>

(1)

(2) (3) (4)

(10)

(5) (6) (7) (8) (9)

(2) Additional SRAM module


Specification : A20B–2902–0350–0352
FROM/SRAM module
Specification : A20B–2902–0341, 0343
A20B–2902–0411
A20B–2902–0500, 0501

(3) Low voltage of memory back up battery. Battery alarm occurs if


voltage is 2.6V or less (3.0V rating).
When the memory back up battery voltage is lowered, BAT is
displayed at lower part of the screen.
When battery alarm is lit, replace with new lithium batteries as soon
as possible.
Refer to 2.8 battery replacing item and change the batteries.
(4) Power supply unit is faulty
When alarm turns off by an operation of clearing all the memory,
power supply unit may also be faulty.

376

You might also like