Keen Ray DR50M Product Introduction

Ver. 1.5_2020
Contents
1. Company Introduction

2. Product Introduction

3. Professional Service
Lanmage creates numerous firsts in the
history of medical devices in China, include
but not limited to:
China’s 1st ceiling-suspended DR with
independent intellectual property rights
China’s 1st mobile DR
China’s 1st dynamic DRF,
China’s 1st batch of suppliers for Color
Doppler Ultrasound systems
...
Lanmage was Over 50% annual
founded installation rate for
History past 4 years in China.

2015 2019

2008 2020

1994 2006
Launched New products will
China first launch (7200A…)
Landwind Radiography Mobile DR
was founded Business Unit
was founded
DR Products Range

Dynamic DRF Digital Mammography Mobile DR Ceiling-suspended DR Floor-mounted DR


Technology Accumulation

430+ patent
History of Mobile DR

2008 2014
DR 200M 2020
DR 50M
China 1st Mobile DR Mobile DR 7200A

2011 2017
DR 200Mate Mobile DR 6000
Contents
1. Company Introduction

2. Product Introduction

3. Professional Service
Keen Ray DR50M monoblock part General Introduction

5.3 KW Generator

10 Inch big touch screen

Advanced APR function(560)

mA range: 10mA-100mA

mAs Range: 0.1-200mAs

Exposure Time Range: 0.001s-4s

Operation Frequency: ≥70KHz

Small Focus & Superior Heat Capacity Tube 1.8mm*1.8mm

Multiple Exposure Methods

Separate Control Console(PLC) with LCD Screen

net weight: 15kg

10
Wireless 17*17 Flat Panel Detector

Integrated Battery Supports Up-to:

8 hours

 Image area: 17”x 17”

 Pixel size: 139 microns

 Spatial resolution: ≥3.6lp/mm


Integrated Design on Whole Rack System

All-in-One Radiology Rack design make easier


centralization for Tube Assembly & generator;

Reduce Rack Movement Problems;

Easy Hand-held or trolley movement


10 inch Visualization Medical Monitor with APR

APR settings make it possible for patients with various examinations.

Various parameters can be preset easily to acquire high resolution images.


Multiple Exposure Methods

Wireless Control Hand Switch Software Timer (needs RS232


connection)

14
Seamless

Patient Image
Information Management
Management System
Seamless i-VisionDR Workstation

Depth optimization processing curve


Preset bone window curve
(focus on bone, weaken soft tissue)
Preset soft tissue window curve
Advanced image curve post-
(highlight soft tissue, weaken bone)
processing

Gray stretch regulation

Window width gain adjustment

Window gain adjustment

Increase strength adjustment

Noise reduction adjustment

Contrast adjustment
C a r e

Standard DAP
Configuration

Monitor current radiation dose in real time


Provide the best exposure moment

DAP (Dose Area Product)


Radiation dose per unit area
Infant Image Optimization

Before After
Professional Pneumoconiosis
Diagnostic Function

Authorized Pneumoconiosis Diagnostic Certificate


issued by National Copyright Administration
Contents
1. Company Introduction

2. Product Introduction

3. Professional Service
We Do Believe that Service is the
Primary Productivity

• 7 x 24 Online Service Support

You might also like