Bend Test 3 Point Report: (MIT) Paud Road, Kothrud PUNE, 411 038
Bend Test 3 Point Report: (MIT) Paud Road, Kothrud PUNE, 411 038
Bend Test 3 Point Report: (MIT) Paud Road, Kothrud PUNE, 411 038
Lot No. :
Heat No. :
Input Data
Output Data
Specimen Shape : Flat Load at Peak : 3.213 kN
Specimen Type : Mild Steel Deflection at Peak : 19.564 mm
Specimen Description : S.Y.B.Tech SOM S-7 Flexural Strength : 963.900 N/mm2
Specimen Width : 40 mm
Specimen Thickness :5 mm
Length : 300 mm
Span Length : 200 mm
Pre Load Value :0 kN
Max. Load : 100 kN
Max. Deflection : 1000 mm
Specimen Cross Section Area : 201.431 mm2