Service Manual: Rondostar 3000
Service Manual: Rondostar 3000
Service Manual: Rondostar 3000
Rondostar 3000
HEADQUARTERS SUBSIDIARIES
RONDO Burgdorf AG RONDO GmbH & Co.KG RONDO Inc.
Heimiswilstrasse 42 Hoorwaldstrasse 44 267 Canarctic Drive
3400 Burgdorf 57299 Burbach Downsview, Ont. M3J 2N7
Switzerland Germany Canada
Phone +41 (0)34 420 81 11 Phone +49 (0)2736 203-0 Phone +1 416 650 0220
Fax +41 (0)34 420 81 99 Fax +49 (0)2736 203130 Fax +1 416 650 9540
info@rondo-online.com info@de.rondo-online.com info@ca.rondo-online.com
www.rondo-online.com
Index
1. Safety regulations
De plus, il faut observer toutes les prescriptions et conseils de sécurité selon chapitre 1
du mode d'emploi!
Before beginning any repair, maintenance, cleaning or similar work on the machine
disconnect the mains plug and interrupt and deaerate all possible existing feeding pipes
of compressed air!
In addition, follow all safety instructions and information according to chapter 1 of the
operating manual!
2 Full View of the Machine
SFS6115 SFS6117
4 3 4 5 1
1 5 2
11 6 11 7
10
14 13
16 17 15 17
SFI6117H
13
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no Part name
8935 Feinsicherung 2,0A träg Fusible 2,0A lent Fuse 2,0A slow
9371 Endschalter Interrupteur fin de course Limit switch
11334 Empfängerkopf Tête de récepteur Receiver head
11335 Senderkopf Tête de transmetteur Transmitter head
50477 Grundmodul Module de base Modul basic
50481 Handrad komplett Roue à main compl. Handwheel compl.
50482 Absolutwertgeber Codeur en valeur absolue Rotary encoder
50483 Drehknopf Bouton tournant Turning knob
50495 Feinsicherung 0,63A träg Fusible 0,63A lent Fuse 0,63A slow
50587 Prozessoreinheit Unité microprocesseur Microprocessor unit
106111 Lichtschrankenkabel Câble pour cell. photoélectr. Cable for light barrier
106112 Lichtschrankenkabel Câble pour cell. photoélectr. Cable for light barrier
135202 *** Frequenzumrichter 230 V Variateur de fréquenze 230 V Frequency inverter 230 V
135203 *** Frequenzumrichter 400 V Variateur de fréquenze 400 V Frequency inverter 400 V
Scraper:
New scraper system, consisting of 4 single scrapers instead of the pairs of scrapers.
125921T01D / V1.10
The software version is new also indicated on the processor beside the mark of the
serial number.
By delivery of the processors the parameters for clutches and for the new light
barrier wipers are set.
______________________________________________________________________________________________________________________________________________________________________________________________________
The software for the RONDOSTAR is equipped with special functions to assist the technical
service.
Other functions: For entering press the key "flour duster". The information on these
functions is not contained in the operating manual.
The functions listed above are described in detail in the following chapters.
Warning
Changing the functions requires great care and forethought.
4.2 Initialisation
Function
When the processor is initialised, the basic data (parameters, sheeting programs) are loaded
from the program EPROM into the processor's working memory.
When initialisating, all previously entered data such as customer programs, special parameters,
etc. are overwritten by the basic data.
______________________________________________________________________________________________________________________________________________________________________________________________________
- Where faults are suspected in the processor's control procedure (software errors)
In this case proceed as follows:
Initialise the parameters (FU 51) ---> then test the machine
How to initialise?
The calibration of the roller gap takes place by a roller gap of 4,0 mm.
Proceed as follows:
The calibration of the roller gap is not affected by initialisation and is not deleted.
______________________________________________________________________________________________________________________________________________________________________________________________________
4.4 Parameter
______________________________________________________________________________________________________________________________________________________________________________________________________
Notes
Key: Select special functions with the key "OK" or with the key "flour duster"
The customer has the option, to change parameter 0, 1, 2 and 3.
See description in the operating manual.
Function: The function is selected with the turning knob.
Function 10 and the associated parameters are exclusively intended for the
technical service (no notes in the operating manual).
Parameters: The parameters are selected with the turning knob and confirmed with "OK"
Value: The figures given in the column "value" are loaded into the working memory from
the EPROM during initialisation and may subsequently be changed.
Before using the diagnostic program, the machine is briefly started in a sheeting program or in
the working mode "manual" (direction of rotation check). As soon as the conveyor belts start to
move, the machine can be stopped and the program may be aborted using "ESC". The turning
direction of the net will be indicated with LED 9 (see chapter 4.5.2)
______________________________________________________________________________________________________________________________________________________________________________________________________
The statuses (On/Off) of the inputs are displayed on the LED of the roller reduction steps,
whereby they are numbered 1 - 9 from left to right.
______________________________________________________________________________________________________________________________________________________________________________________________________
______________________________________________________________________________________________________________________________________________________________________________________________________
The drives can only be started when the safety guards have been closed.
In order to test the drives a number of special test programs are available.
Testing of the individual drives is described in detail in chapter 5.3.
______________________________________________________________________________________________________________________________________________________________________________________________________
Attention:
For the operating voltages 200 - 230 V and 380 - 460 V different types of frequency inverters and
mains filters are necessary.
Motors: Table drive motor, roller adjustment motor, flour duster motor
200 - 230 V Motors delta-connected
380 - 460 V Motors star-connected
Transformer:
The transformer in the basic module must be switched to the new voltage.
______________________________________________________________________________________________________________________________________________________________________________________________________
When the machine is started, the following control process runs automatically:
1. One of the black push buttons is operated.
Here the black push buttons have a dual function.
On the one hand they switch on the main contactor, on the other hand they issue the
command for the direction of rotation of the conveyor belt to the processor.
3. At the time of the first start after switching on the mains, the direction of rotation of the
mains is checked automatically as follows:
The roller drive is briefly switched on and the direction of rotation of the motor is
checked. If the roller rises when given the command "close" (wrong direction), the
direction of rotation of the table, roller adjustment and flour duster drives is
automatically changed.
4. The roller adjustment drive starts and the roller moves to the roller gap shown in the
display. At the same time the automatic reeler is opened if it is not already in the upper
end position.
5. The table drive starts automatically when the roller end position is reached.
The position of the roller gap is measured with an absolute value sender. With an angle of
rotation of 360° (roller gap 45.0 - 0.2 mm), the absolute value sender has 256 positions. A
specific roller gap is allocated to each of these 256 positions in the software.
Here the correct calibration of the absolute value sender at a roller gap of 4.0 mm is
paramount. (See chapter 4.3)
The direction of rotation of the mains is checked using the roller adjustment drive. The
controls of the table drive and the flour duster are dependent on the direction of rotation of
the roller adjustment drive.
The turning knob consists of an impulse sender with 128 impulses per revolution.
The turning knob is used to input the data during programming, when selecting the program
and during diagnostic work, etc.
______________________________________________________________________________________________________________________________________________________________________________________________________
The machine automatically tests the direction of rotation of the mains and controls the
machine accordingly.
The roller adjustment drive always depends directly on the direction of rotation of the
mains.
If the direction of movement of the table drive or of the flour duster is incorrect, proceed as
follows:
Flour duster: Switch 2 phases on the motor terminals
Table drive: First check if the black push buttons are correctly connected.
(See checking the inputs, chapter 4.5.2, LED 3 and LED 4)
Are the push buttons correctly connected, switch 2 phases of the
motor cable on contactor K2M.
Proceed as follows:
- Select "Manual" working mode
- Operate left push button conveyor belt must run to the right
Stop by using red push button
- Leave the program with "ESC"
- Operate right push button conveyor belt must run to the left
Stop by using red push button
- Leave the program with "ESC"
______________________________________________________________________________________________________________________________________________________________________________________________________
The correct direction of rotation for the flour duster has been determined by the automatic
check on the direction of rotation of the mains. (Do not change output A8).
To check the flour duster, switch on the diagnostic program as described under 4.5.1
- Switch on working mode "Auto" LED "AUTO" on
continuously
- Press key "flour duster" during approx. 10 s Indication: FU 0 --
- Set function "30" by turning knob Indication: FU 30 --
- Press key "OK" till Indication: d. 1** 0
Now the diagnostic program is switched on
** = Indication is flashing
The motor of the reeler drive is equipped with limit switches which automatically interrupt the
electricity supply in the end position.
** = Indication is flashing
Warning: Do not change the direction of rotation while the reeler is moving.
In order to test the brake of the roller adjustment drive in the diagnostic program, proceed
as follows:
- Switch on the diagnosic program as described under 4.5.1
- Set d = 7 by turning knob Indication: d 7** 0
- Brake ON by key "OK" Indication: d 7** 1
- Brake OFF by key "OK" Indication: d 7** 0
** = Indication is flashing
______________________________________________________________________________________________________________________________________________________________________________________________________
For the operation Cutomat the Cutomat clutch (outputs A3 and A4 = 1) as well as the slow
speed (output A5 = 1) have to be switched on.
For testing the function Cutomat, set a simple auto-program with Cutomat in program 1,
3 positions:
Initial roller gap 10 mm
Final roller gap 6 mm
Roller reduction curve 5
Function Cutomat:
Now the program will start in the final test (See 5.4). If the endthickness is reached, start
the machine with the black push button.
Now the rollers open about 5 mm and the machine starts with the Cutomat speed. The
table on the infeed side has to run exactly as fast as the table on the outfeed side. A click
of the driving wheels in the front housing is audible (normal).
Warning:
Continuous operation is only possible using programs with the functions "Stop for
folding" or "automatic reeling".
______________________________________________________________________________________________________________________________________________________________________________________________________
6. Compound operation
The Rondostar SFS6117 is also qualified for compound operation with a transfer table
(dough transfer with sheeting speed).
The Rondostar SFS6117DD is qualified for compound operation with a make-up line or a
donut line. The variable speed for the dough transfer is approx. 1,5 - 7,5 m/min for make-up
lines and approx. 15 - 25 m/min for donut lines.
In compound operation with make-up lines respectively donut lines, the Rondostar can be used
together with one or two lines. The following operating modes are possible (parameter 30):
- Make-up line / donut line to the left of the Rondostar
- Make-up line / donut line to the right of the Rondostar
- One make-up line / donut line on each side of the Rondostar
Compound operation with make-up lines respectively donut lines is only possible with the
Rondostar SFS6117DD. The Rondostar SFS6117DD can also be used like a standard
machine (Function Cutomat not possible). Special processor parameters, see chapter 6.3.
The compound operation with a transfer table is possible with a normal Rondostar
(without variable speed). The release for transfer takes place by the transfer table (high
speed).
______________________________________________________________________________________________________________________________________________________________________________________________________
6.2 Function
6.2.1 Compound operation with one make-up line respectively donut line
For compound operation a program containing the final function "Cutomat" must
always be produced.
Sheeting takes place as for a normal sheeting program. The dough band is stopped in the
same position as for "place manual reeler". The dough position can be set by
parameter 2.
The dough transfer starts, if the release is given by the line (input E6).
The dough band is transferred at reduced speed. The time for transfer can be set by
parameter 3. When the transfer time is run down the sheeting program is finished (The rollers
revert to the initial roller gap).
Transfer speed:
Adjustable on the potentiometer as by Cutomat. The time for the transfer of the dough depends
on the speed! The time can be set by parameter 3.
The following parameters have to be set on the processor for compound operation.
- Parameter 30: Definition of compound operation (left, right, both sides)
- Parameter 2: Stop position on the table end if the dough cannot be transferred.
- Parameter 3: Running time for the dough transfer (depends on the transfer speed).
The parameters 2 and 3 can also be set by the customer (operating manual)
______________________________________________________________________________________________________________________________________________________________________________________________________
______________________________________________________________________________________________________________________________________________________________________________________________________
______________________________________________________________________________________________________________________________________________________________________________________________________
The control voltages can also be checked at the basic modul on the terminals TP1 - TP6
(Close to the fuses)
______________________________________________________________________________________________________________________________________________________________________________________________________
All connections to the basic module are plugable and allow a quick and faultless exchange.
The following picture shows the numbering of the plug connections. Based on these, in
combination with the diagram, the output voltage on the basic module can be
measured.
7.4.1 Types
For 200 - 230 V and 380 - 460 V different types of frequency inverters and mains
filters are used.
7.4.2 Parameterization
The frequency inverters delivered by RONDO Burgdorf AG, CH are already
parameterized. The inverters can be used without a change for the sheeting
machine Compas SFA612.
______________________________________________________________________________________________________________________________________________________________________________________________________
The inverter performs internal switching. Therefore, a leakage current flows through the
inverter. This leakage current may actuate the ground fault interrupter, shutting the power
off.
Use a ground fault interrupter with a high leakage-current detection value (sensitivity
amperage of 200mA or more, operating time of 0,1 s or more) or one with high-frequency
countermeasures for inverter use.
In addition, remember that a leakage current increases in proportion to the cable length.
Normally, approximately 5 mA of leakage current is generated for each meter of cable.
______________________________________________________________________________________________________________________________________________________________________________________________________
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
8.4.1 Unterbau
Socle 125787
Machine base
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
7167 Sicherungsring für Welle Circlips pour arbre 12x1 Circlip for shaft 12x1
12x1
7170 Sicherungsring für Welle Circlips pour arbre 17x1 Circlip for shaft 17x1
17x1
7246 Rillenkugellager 6201 2RS Roulement à billes 6201 2RS Ball bearing 6201 2RS
7512 Rillenkugellager 6304 2RS Roulement à billes 6304 2RS Ball bearing 6304 2RS
9365 Zyl.Schraube m. Vis cylindrique avec tête Cylinderscrew with hexagon
Innensechskant M8x12 hexagonal M8x12 head M8x12
9524 Rillenkugellager 6003 2RS Roulement à billes 6003 2RS Ball bearing 6003 2RS
11571 Distanzbolzen 6Kt. M6x55 Bouton d'écartement hexagonal Distance bolt hexagon
M6x55 M6x55
50162 Gasfeder 350N Ressort pneumatique 350N Gas spring 350N
50277 Passkerbstift 5x60 Goupille cann.d'ajustage à Taper-grooved dowel pin
gorge 5x60 5x60
83273T05 Rolle Stahl Rouleau en acier Steel cylinder
99090 Scheibe Disque Disc
101507 Führung Guide Guide
107751T03 Schaltstab Axe Rod
107752 Arretierungsblech Tôle d'arrêt Locking sheet metal
121332 Mitnehmer Entraîneur Catch
121334T01 Torsionsfeder Ressort à torsion Torsion spring
121334T02 Torsionsfeder Ressort à torsion Torsion spring
121337 Rastsegment Segment cranté Catch segment
121339 Hülse Douille Husk
121340T02 Welle Arbre Shaft
122828 Verstärkung Renforcement Reinforcement
122945T01 Achse Axe Axle
122945T04 Achse Axe Axle
122946 Schutzblech vorne Tôle de protection avant Front protection plate
122967 Seitenplatte komplett, Plaque latérale Side plate complete,
hinten complete,arrière posterior
122968 Seitenplatte komplett Plaque latérale complete, avant Side plate complete, auterior
vorne
122985 Lasche komplett Collier de fixation complet Bracket complete
123061 Schutzgitter komplett Grille de sécurité complete Safety guard complete
123219 Hebel linke Ausführung Levier gauche complet Lever left complete
komplett
123278 Schutzblech Tôle de protection Protection plate
123691 Hebel lang Levier longue Lever long
123692 Hebel kurz Levier court Lever short
123693 Nabe Moyen Hub
123697 Verstärkung Renforcement Reinforcement
123702 Hebel kurz, rechts Levier court, droite Lever short, right
124690 Nutenstein Coulisseau Sliding block
125459 Büchse Douille Bush
125462 Drehherz Toc du tour Driving dog
125463 Zahnsegment Segment denté Toothed quadrant
126574 Maschinentisch 65 Table de machine 65 Machine table 65
127796 Schutzgitter komplett Inox Grille de sécurité complete Inox Safety guard compl. Inox
128109 Federführung mit Lager Guidage de ressort avec palier Spring guide with bearing
128332 Hebel komplett Levier complet Lever complete
135589 Schutzblech hinten Tôle de protection arrière Rear protection plate
8.7 Mehlstreuer Inox
Saupoudreur à farine Inox 106573
Flour duster Inox
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering nr Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering nr Part name
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering nr Part name
6815 Senkschraube mit Schlitz Vis à tête fraisée avec fente Screw M6x10
M6x10 M6x10
9172 U-Scheibe M12x2 Rondelle Washer
9351 Rillenkugellager Roulement à billes Ball bearing
9756 Lagerbüchse ohne Bund Coussinet Bearing bush
10996 Distanzscheibe 30/42/0.5 Rondelle d'espacement Spacing washer
11352 6kt. Mutter M12x0.5D rostfrei Ecrou hexagonal M12x0,5D Nut hexagon M12x0,5D
11445 6kt. Mutter M8x8 Ecrou hexagonal indesserable Self-locking hexagon nut
selbstsich.rostfrei M8x8 M8x8
12092 PT-Linsenschraube Vis PT Screw 5x10
m.Kreuzschlitz 5x10 5x10
50011 U-Scheibe M5x1.2 Rondelle M5x1.2 Washer M5x1.2
50314 Steckereinsatz Insert de prise male Plug insert
50315 Steckereinsatz Insert de prise male Plug insert
50322 Distanzscheibe 12/24x0.5 Rondelle d'ecartement Spacer-washer
50466 O-Ring O-Anneau O-Ring
50468 Rillenkugellager Roulement à billes Ball bearing
50469 Rillenkugellager Roulement à billes Ball bearing
50471 Passschraube m. I6kt. M8x20 Vis spec. M8x20 Screw spez. M8x20
50491 Zyl.Schraube m.I6kt. M4x8 Vis cylindrique avec tête Cylinderscrew with hexagon
hexagonal M4x8 head M4x8
50564 O-Ring O-Anneau O-Ring
50725 Anbaugehäuse Boîte adaptable Attached housing
50739 Senkschraube M6x16 special Vis à tête conique M6x16 Countersunk screw M6x16
spécial special
51270 Sockelgehäuse inkl. Boîte de socle incl. passe- Base housing incl. screwed
Kabelverschraubung câble à vis cable gland
51273 Tüllengehäuse inkl. Boîte de passe-câble incl. Gromment housing incl.
Kabelverschraubung passe-câble à vis screwed cable gland
51334 Kabelverschraubung Passe-câble à vis Screwed cable gland
72750 Schraubendruckfeder Ressort à pression Compression spring
103551T04 Welle Arbre Shaft
108526 Traverse Traverse Tie-bar
124553 Zwischenrad Z=12 Roue intermédiare Z=12 Intermediate wheel Z=12
124554T01 Hülse Douille Husk
124554T02 Hülse Douille Husk
124559 Zwischenplatte Plat intermédiaire Intermediate plate
124560V1 Leerlaufrolle 1 Rouleau à vide 1 Idle roller 1
124561V1 Leerlaufrolle 2 Rouleau à vide 2 Idle roller 2
124562V1 Leerlaufrolle 3 Rouleau à vide 3 Idle roller 3
124563V1 Leerlaufrolle 4 Rouleau à vide 4 Idle roller 4
124564V1 Leerlaufrolle 5 Rouleau à vide 5 Idle roller 5
124565 Schwenkplatte oben links Plaque tournante en haut Swifel plate above left
gauche
124568 Schwenkplatte unten rechts Plaque tournante en bas Swifel plate below left
droite
124569 Abdeckung Schwenkplatte Recouvrement droite Front cover right
rechts
124570 Abdeckung Schwenkplatte links Recouvrement gauche Front cover left
124571 Rolle Rouleau Roller
124572 Kupplungsplatte Plaque d'embrayage Clutch-plate
124575T01 Strebe Chandelle Stanchion
124576 Welle Arbre Shaft
124578 Schwenkplatte Plaque tournante Swifel plate
124579 Seitenplatte rechts Plaque latérale droite Side plate right
124582 Bolzen Boulon Bolt
124583 Sicherheitsblech Tôle de sécurité Security plate
124584 Schwenkplatte oben rechts Plaque tournante en haut Swifel plate above right
komplett complete complete
124585 Schwenkplatte unten links Plaque tournante en bas Swifel plate below left
komplett complete complete
124586 Seitenplatte links komplett Plaque latérale gauche Side-plate left complete
complete
124587 Antriebsrolle Rouleau d'entraînement Driving roller
124591 Halteplatte Plaque Holding plate
124594 Profil-Strebe Chandelle Stanchion
124595 Motor mit Kabel Linak Moteur avec câble Linak Motor with cable Linak
124595T03 Motor mit Kabel Linak Moteur avec câble Linak Motor with cable Linak
124597 Mitnehmerstift Entraîneur-broche Catch-bolt
126381 Gabel Fourche Forked support
126894 Profilrohr Tube profilé Special section tube
130530 Antriebsrad Z=10 Roue dentée Z=10 Gearwheel Z=10
130531 Antriebsrad Z=12 Roue dentée Z=12 Gearwheel Z=12
130532 Antriebsrad Z=13 Roue dentée Z=13 Gearwheel Z=13
130533 Zwischenrad Z=12 Roue intermédiare Z=12 Intermediate wheel Z=12
8.8.1 Convert the automatical dough reeler from the right to the left machine table
Mechanical modification
- Dismount both machine tables
- Dismount the reeler
- Interchange the drive rollers on both machine tables i. e. drive roller of the existing left table will be new in the right
table mounted, drive roller of the existing right table will be new in the left table mounted.
left table
right table
- Change the table hook on the right side of machine head and the bolt on the right machine table (only SFS, without SFI)
table hook
right
table
- Mount the automatical dough reeler on the left machine table bolt
- Mount both machine tables
Electrical conversion
- On the existing reeler cable dismount the connecting plug to the reeler
- Interchange mutually the blind plug and the rubber funnel for the cable passage in the base front-left / rear-right.
- Extract the reeler-cable front-left through the rubber funnel and lay it to the reeler.
- Reconnect the plug on the reeler cable. Lead No. 1 to connection 1, lead No. 2 to connection 2.
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
50048 Gasfeder 100N ohne Vérin à gaz 100N sans Pneumatic spring 100N
automatischem Haspel enrouleur automatique without automatic reeler
50485 Gasfeder 200N mit Vérin à gaz 200N avec Pneumatic spring 200N with
automatischem Haspel enrouleur automatique automatic reeler
8.9 Elektrokasten
Boîte électrique 108611
Electrical box
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
8935 Feinsicherung 2,0A träg Fusible 2,0A lent Fuse 2,0A slow
50361 Kleinleistungschütz Contacteur de petit calibre Contactor miniature
50362 Kleinleistungsschütz Contacteur de petit calibre Contactor miniature
50477 Grundmodul Module de base Basic module
50495 Feinsicherung 0,63A träg Fusible 0,63A lent Fuse 0,63A slow
52120 Durchgangsklemme Borne Terminal
52122 Schutzleiterklemme Borne de terre Earth terminal
52124 Abschlussplatte Plaque de fermeture End cover plate
52131 Endklammer Pièce finale End piece
105404 Elektrokasten Boîte électrique Electrical box
105405 Elektrokasten UL Boîte électrique UL Electrical box UL
105406 Deckel Couvercle Cover
105407 Deckel UL Couvercle UL Cover UL
8.10 Elektrokasten Cutomat
Boîte électrique Cutomat 108620
Electrical box Cutomat
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
8935 Feinsicherung 2,0A träg Fusible 2,0A lent Fuse 2,0A slow
50359 Hilfsschalterblock Bloc de contacts auxiliaires Contact block auxiliary
50361 Kleinleistungschütz Contacteur de petit calibre Contactor miniature
50362 Kleinleistungsschütz Contacteur de petit calibre Contactor miniature
50477 Grundmodul Module de base Modul basic
50495 Feinsicherung 0,63A träg Fusible 0,63A lent Fuse 0,63A slow
50604 Zeitrelais Relais temporise Time relais
50628 Dreiphasen-Netzfilter Filter au réseau triphasé Triphase mains filter
52120 Durchgangsklemme Borne Terminal
52122 Schutzleiterklemme Borne de terre Earth terminal
52124 Abschlussplatte Plaque de fermeture End cover plate
52131 Endklammer Pièce finale End piece
105404 Elektrokasten Caisse de commande Control box
105405 Elektrokasten UL Caisse de commande UL Control box UL
105406 Deckel Couvercle Cover
105407 Deckel UL Couvercle UL Cover UL
135202 Frequenzumrichter 230V Variateur de fréquence 230V Frequency inverter 230 V
135203 Frequenzumrichter 400V Variateur de fréquence 400V Frequency inverter 400 V
8.11 Vorderer Deckel: Elektrische Ausrüstung
Couvercle avant: Equipement électrique 108621
Front cover: Electrical equipment
Bestell-Nr. Teilebezeichnung
No commande Désignation
Ordering no. Part name
12036 Kabelbride Bride pour câble Cable clamp
50481 Handrad komplett Roue à main complete Handwheel complete
50483 Drehknopf Bouton tournant Turning knob
50484 Flachbandkabel 20-pol. Câble plat, 20 pol. Ribbon cable, 20 pol.
50587 Prozessoreinheit Unité microprocesseur Microprocessor unit
50925 Pilztaster schwarz Bouton poussoir noir Push button black
50926 Pilztaster rot Bouton poussoir rouge Push button red
50927 Hilfsschalterblock 2S Bloc de contact auxiliaires 2S Contact block auxiliary 2S
50928 Hilfsschalterblock 10 Bloc de contact auxiliaires 10 Contact block auxiliary 10
124606 Speisekabel zu Câble d'alimentation. Cable for processor supply
Prozessor proceseur
124607 Kabel zu Tasten Câble pour bouton poussoir Cable for push-button
124609 Kabel zu Tasten Câble pour bouton poussoir Cable for push-button
125559 Vorderer Deckel Couvercle avant Front cover
125563 Blech zu Display Tôle pour display Sheet for display
0 1 2 3 4 5 6 7 8 9
RONDO Burgdorf AG
A Heimiswilstrasse 42 A
CH-3400 Burgdorf
Tel.: +41 (0)34 420 81 11
Fax: +41 (0)34 420 81 99
Webseite: www.rondo-online.com
E-mail: service a ch.rondo-online.com
B B
E E
31.03.2010
Plot-Datum:
2 Sicherung traeg -A1/F1 1.6 50495 In=T 0,63A Dm=5x20 18 Handrad -G1 5.4 50481
Fusible a act. ret. +1 / Bouton tourant +2 /
Fuse slow =RONST01 Turning knob =RONST01
3 Sicherung traeg -A1/F2 1.6 8935 In=T 2.0A Dm=5x20 19 Drehknopf -G1 5.4 50483 d=65mm
Fusible a act. ret. +1 / Bouton tournant +2 /
Fuse slow =RONST01 Turning knob =RONST01
4 Sicherung traeg -A1/F3 1.6 8935 In=T 2.0A Dm=5x20 20 Impuls-Pilztaster schwarz -S1 3.3 50925
Fusible a act. ret. +1 / Bouton-poussoir noir +2 /
Fuse slow =RONST01 Push-button black =RONST01
6 Kleinleistungsschuetz -K2M 3.7 50362 Usp.=24VDC 22 Impuls-Pilztaster schwarz -S2 3.4 50925
Contacteur de petit calibre +1 / Bouton-poussoir noir +2 /
Contactor miniature =RONST01 Push-button black =RONST01
8 Stecksockel m. Loeschdiode -K4 3.9 50172 14 pol 24 Impuls-Pilztaster rot -S3 3.2 50926 rot
Socle enfichable +1 / Bouton-poussoir rouge +2 /
Plug-in socket =RONST01 Push-button red =RONST01
9 Klein Steckrelais -K4 3.9 50092 Usp.=24VDC 25 Hilfsschalterblock 1Ö -S3 3.2 50928 1 x O
Petit relais enfichable +1 / 14 pol 4W Element de contact +2 /
Plug-in relay miniature =RONST01 Contact element =RONST01
10 Flachbandkabel -W12 5.3 50484 20 pol. 26 Lichts. Empfaengerkopf -B1 5.6 11334
Cables plat +1 / lm=2100mm Tete de recepteur +3 /
Ribbon cable =RONST01 Receiver head =RONST01
11 Kabel Empfaenger -W13 5.6 106111 2 pol mit Stecker 27 Lichts. Senderkopf -B2 5.6 11335
Cables recepteur +1 / lm=2200mm Tete de transmetteur +3 /
Cable receiver =RONST01 Transmitter head =RONST01
12 Kabel Sender -W14 5.6 106112 2 pol mit Stecker 28 Hubspindelmotor -G1 4.7 124595 Pn=0.040kW Un=24VDC In=1.6A
Cables transmetteur +1 / lm=1000mm Moteur vis dehissage +3 /
Cable transmitter =RONST01 Lifting spindle motor =RONST01
13 ZF-Durchgangsklemme v. oben,4L -X1. 3.0 52120 4 x 2.5mm2 29 Absolutwertgeber -G2 5.5 50482
Borne +1 / Codeur en valeur absolue +3 /
Terminal =RONST01 Rotary Encoder =RONST01
14 ZF Schutzleiterklemme isol.;4L -X1. 3.0 52122 4 x 2,5mm2 30 AC Fuss-Motor -M1 1.1 50603 Un=230/400V F=50/60Hz Pn=1.1kW
Borne de terre +1 / Moteur +3 / In=4.65/2.65A n=1410/1715U/min
Earth terminal =RONST01 Motor =RONST01
16 Endklammer für TS35 -X1. 3.0 52131 32 AC Fuss-Motor -M1 1.1 51309 Un=220/460V F=50/60Hz Pn=1.1kW
Piece finale +1 / Moteur +3 / In=4.60/2.30A n=1415/1700U/min
End piece =RONST01 Motor =RONST01
Plot-Datum: 31.03.2010
Änderung Datum Name Datum Name Bez. Gerätestückliste Zeichn.-Nr.: Ort: Anlage:
e 500680e GERLIST
gez. 27.11.2003 Ryser
b
Auftrag: Bl:
c Anlagenbez. 1
gepr.
d Dough-how & more. Rondostar 3000 , SFS611 Bl.
1 2 3 4 5 6 7 8 9 10
POS BENENNUNG DEUTSCH -BMK BL.PFAD ARTIKEL-NR. TECHNISCHE DATEN 1 POS BENENNUNG DEUTSCH -BMK BL.PFAD ARTIKEL-NR. TECHNISCHE DATEN 1
BENENNUNG FRANZOESISCH +ORT / TECHNISCHE DATEN 2 BENENNUNG FRANZOESISCH +ORT / TECHNISCHE DATEN 2
BENENNUNG ENGLISCH =ANLAGE AUFTRAGS-NR. BEMERKUNGEN BENENNUNG ENGLISCH =ANLAGE AUFTRAGS-NR. BEMERKUNGEN
Plot-Datum: 31.03.2010
Änderung Datum Name Datum Name Bez. Gerätestückliste Zeichn.-Nr.: Ort: Anlage:
e 500680e GERLIST
gez. 27.11.2003 Ryser
b
Auftrag: Bl:
c Anlagenbez. 2
gepr.
d Dough-how & more. Rondostar 3000 , SFS611 Bl.
0 1 2 3 4 5 6 7 8 9
Kabelname Sachnummer Adern x Querschnitt / Laenge Ziel 1 Ader Ziel 2
------121017T06------------------------------------------------------------------------------------------------
W1 12753 4 1.50
A A
L1 1 =RONST01+3-Q1:1
L2 2 =RONST01+3-Q1:3
L3 3 =RONST01+3-Q1:5
PE gegn =RONST01+3-Q1.:PE
------121017T04------------------------------------------------------------------------------------------------
W2 12753 4 1.50
=RONST01+3-Q1:2 1 =RONST01+1-K1M:2
=RONST01+3-Q1:4 2 =RONST01+1-K1M:4
B B
=RONST01+3-Q1:6 3 =RONST01+1-K1M:6
=RONST01+3-Q1.:PE gegn =RONST01+1-X1:PE
------121017T05------------------------------------------------------------------------------------------------
W3 12753 4 1.50
=RONST01+3-M1:V 1 =RONST01+1-K2M:2
=RONST01+3-M1:U 2 =RONST01+1-K2M:4
=RONST01+3-M1:W 3 =RONST01+1-K2M:6
=RONST01+3-M1:PE gegn =RONST01+1-X1:PE
C C
------124605---------------------------------------------------------------------------------------------------
W4 13616 7 1.00
=RONST01+3-M2:U 1 =RONST01+1-X4:1
=RONST01+3-M2:V 2 =RONST01+1-X4:2
=RONST01+3-M2:W 3 =RONST01+1-X4:3
=RONST01+3-Y1:2 4 =RONST01+1-X4:4
=RONST01+3-Y1:1 5 =RONST01+1-X4:5
6
D D
=RONST01+3-M2:PE gegn =RONST01+1-X4:6
------121017T01------------------------------------------------------------------------------------------------
W5 12753 4 1.50
=RONST01+3-M3:U 1 =RONST01+1-X3:1
=RONST01+3-M3:V 2 =RONST01+1-X3:2
=RONST01+3-M3:W 3 =RONST01+1-X3:3
=RONST01+3-M3:PE gegn =RONST01+1-X3:4
------124593---------------------------------------------------------------------------------------------------
E E
W6 13070 2 1.00
=RONST01+3-X1:4 1 =RONST01+1-X10:1
=RONST01+3-X1:3 2 =RONST01+1-X10:2
------121016T03------------------------------------------------------------------------------------------------
W7 13069 2 0.75
=RONST01+1-X1:1 1 =RONST01+3-S10:13
=RONST01+1-X1:2 2 =RONST01+3-S11:13
31.03.2010
------131850---------------------------------------------------------------------------------------------------
W8 13259 5 1.00
Plot-Datum:
=RONST01+1-X1:4 1 =RONST01+2-S2:24
Änderung Datum Name Datum Name Bez. KABELLISTE Zeichn.-Nr.: Ort: Anlage:
e 500680e KABEL
gez. 05.11.2002 Saladin
b
Auftrag: Bl:
c Anlagenbez. 1
gepr.
d 32370 04.10.2002 Sa Dough-how & more. Rondostar 3000 , SFS611 Bl.
0 1 2 3 4 5 6 7 8 9
Kabelname Sachnummer Adern x Querschnitt / Laenge Ziel 1 Ader Ziel 2
------131850---------------------------------------------------------------------------------------------------
W8 13259 5 1.00
A A
=RONST01+1-X1:6 2 =RONST01+2-S2:13
=RONST01+1-X1:2 3 =RONST01+2-S3:11
=RONST01+1-X1:3 4 =RONST01+2-S1:14
=RONST01+1-X1:5 5 =RONST01+2-S1:24
------124609---------------------------------------------------------------------------------------------------
W8.1 13069 2 0.75
=RONST01+2-S1:13 1 =RONST01+2-S2:13
=RONST01+2-S1:24 2 =RONST01+2-S2:14
B B
------124606---------------------------------------------------------------------------------------------------
W11 13448 5 0.75
=RONST01+2-X5:1 1 =RONST01+1-X2:1
=RONST01+2-X5:2 2 =RONST01+1-X2:2
=RONST01+2-X5:4 3 =RONST01+1-X2:4
=RONST01+2-X5:5 4 =RONST01+1-X2:5
=RONST01+2-X5:3 gegn =RONST01+1-X2:3
------126860---------------------------------------------------------------------------------------------------
C C
W15 13448 5 0.75
=RONST01+3-X11S:R 1 =RONST01+1-X1:30
=RONST01+3-X11S:R 2 =RONST01+1-X1:32
=RONST01+3-X11S:L 3 =RONST01+1-X1:32
=RONST01+3-X11S:L 4 =RONST01+1-X1:31
gegn
D D
E E
31.03.2010
Plot-Datum:
Änderung Datum Name Datum Name Bez. KABELLISTE Zeichn.-Nr.: Ort: Anlage:
e 500680e KABEL
gez. 05.11.2002 Saladin
b
Auftrag: Bl:
c Anlagenbez. 2
gepr.
d 32370 04.10.2002 Sa Dough-how & more. Rondostar 3000 , SFS611 Bl.
0 1 2 3 4 5 6 7 8 9
Prozessoreinheit -24/2.0
+2
Unite microprocesseur 15V 24V +24-A/2.0
-A2 PE - + + -
Microprocessor unit
+2 E2
A A
1
-X5 +2
2 4 6
14
13
15
-X2
-K1M
gegn
/3.6 1 3 5
1
W11
14
13
15
gegn
Grundmodul
-A1 -X2 -X7
Module de base
2
3
1
1
TB4
TB3
TB2
TB1
B W2 Basic module B
+24/2.0
+
+
L1 -A1/F1 C1
1 460 10
2 4 6 1 3 5 1 3 5
0,63AT
1 400
-K2M -K3M -X1 R1
2 4 6 2 4 6 230 10V/0,6A
/3.7 /3.7
+3 D11
PE
200 11
-Q1 13 -A1/F2
C 1 3 5 C
2,0AT
4,0--6,3
A
6,0 19V/1,25A
14 D12 +
+ R2
17 -A1/F3
2,0AT
C2 C3
26V/1,6A
-X1 GND/2.0
2 0 18
X10
PE
2
D -X1
71 VA D
3
L1/2.0
4 3
L2/2.0
5 4
gegn
gegn
L3/2.0
6 5
2
3
2
3
1
6
W1 W3 -X1 L17/4.0
V U W PE L18/4.0
M
E +3 E
3~
L1
L2
L3
PE
A A10 A6 A7 A8 A9 A
+2 +2 +2 +2 +2
11
10
-X2 -X2 -X2 -X2 -X2
10
11
8
7
9
-X7 -X7 -X7 -X7 -X7
+24/1.9 +24/3.0
B B
3 3 3
D5 K5 K7 D7 D6 K6
2 2
4 2 4 4
D14
GND/1.9 GND/3.0
C L1/1.9 C
L2/1.9
L3/1.9
7 8 9 10 9 8 7 10
K1 D1 K3
1 4 2 5 3 6 11 3 6 2 5 1 4 11 D3
D 6 3 5 2 4 1 10 4 1 5 2 6 3 10
D
D2
D4
K2 K4
9 8 7 11 7 8 9 11
2
3
6
2
3
4
-X4 -X4
1
1
-X3
-X4 -X4 -X3
1
2
3 3
gegn 6
1
2
3
gegn 4
2
2
3
1
1
E W4 W5 E
U V W PE U V W PE
230/400V 0,85/0,48A / 50Hz 1 220/400V 0,5/0,3A / 50Hz
M M
+3 230/400V 0,8/0,46A / 60Hz +3 +3 254/440V 0,5/0,3A / 60Hz
3~ 0,090 kW -Y1 2 3~ 0.090 kW
-M2 -M3
1410/1700 U/min 1500/1800 U/min
E5 E3 E7
A A0 A2 A11 A
+2 +2 +2 +2 +2 +2
18
16
20
12
-X2 -X2 -X2 -X2 -X2 -X2
20
18
16
12
3
1
-X7 -X7 -X7 -X7 -X7 -X7
B +24/2.9 +24/4.0 B
3 3
3 K9 K13
D9 4 2 2
K8 D8 4
2 4
3
R3 K10
D10
4 2
C C
H1
GND/2.9 GND/4.0
-X6
7
1
P1-3/4.2
5
D D
2
7
-X5
1
8
-X5
1
7
2
6
1
13
-X1. -X1 -X1 -X1 -X1 -X1
-K1M
P1-2/4.0 .6 14
21 22
3
2
1
W8 -K3M -K2M
2
1
W7 1 2 1 2 .7 22 .7 21 1 2
2 /1.3 /1.1 /1.3 A1
11
E 13 13 +2 24 +2 14 +2 24 +2 14 3 4
/1.3
3 4
/1.1
3 4
/1.3 -K4
E
A1 A1 A1
+3 +3 +2 -S1 -S1 -S2 -S2 5 6
/1.3 -K1M
5 6 5 6
/1.1 -K2M -K3M /1.3 A2
10
-S10 14 -S11 14 -S3 12 .3 13 .3 13 .4 13 .4 13 13 14 21 22 21 22
.5 A2 .7 A2 A2 .7 -X1
1
14
W8.1 11
12
Schutzgitter Start Maschine Hauptschütz für Hauptantrieb 24
31.03.2010
21
Grille de protection Mise en marche machine Contacteur principal pour Commande principale 22 /4.9
Safety guard Start machine Main contactor for Main drive 34
31
links rechts AUS Teig nach rechts Teig nach links Netzeinspeisung EIN 32
Plot-Datum:
gauche droite DECL. Pâte à droite Pâte à gauche Branchement au reseau ENCL. 44
41
left right OFF Dough to the righte Dough to the left Mains supply ON 42
E6 E4
A A4 A5 A1 A3 A
+2 +2 +2 +2 +2 +2
19
17
4
-X2 -X2 -X2 -X2 -X2 -X2
19
17
4
-X7 -X7 -X7 -X7 -X7 -X7
3
B +24/3.9 K14 B
2 4
X81 -D13
L17/1.9
D L18/1.9 D
4
-X10 -X10 -X10
1
-X10
3
-X5
9
P1-3/3.4
3
-X5 orange
9
1
20
W6 21 -K4
Als Option Als Option 24 VDC /3.9
grau
3
4
Comme option Comme option 1,6 A 24 22
+3 +3 braun violett
E As option As option 200 N E
-X10S
32
30
-G1
31
EU UL
Teighaspel
4
2
3
4
21
1
Enrouleur à pâte
Dough reeler braun blau W15
P1-2/3.1
4
21
R
L
R
P1-2/3.1 Teighaspel Teighaspel
R
L
R
31.03.2010
-Y3 2 -Y2 2
Tapis de transfer ferme = 1 ENCL. / DECL.
Transfer conveyor close =1 ON / OFF
GND
Sig.
Basic module Light barrier
+
-
-W13
W11
-W14
-W12
weiss
braun
58
59
60
61
2
3
4
4
1
B B
rot
C C
D D
E E
31.03.2010
RONDO Burgdorf AG
A Heimiswilstrasse 42 A
CH-3400 Burgdorf
Tel.: +41 (0)34 420 81 11
Fax: +41 (0)34 420 81 99
Webseite: www.rondo-online.com
E-mail: service a ch.rondo-online.com
B B
C
Rondostar 3000 Cutomat SFS611C C
D D
E E
31.03.2010
Plot-Datum:
1 Grundmodul -A1 1.5 50477 17 Widerstand -R2 1.1 R1.5K Rn=1,5kOhm Pn=0,6W
Module de base +1 / Resistances +1 /
Module, basic =RONST02 Ecostar/Rondostar/Kombi Resistor =RONST02
2 Sicherung traeg -A1/F1 1.6 50495 In=T 0,63A Dm=5x20 18 Flachbandkabel -W12 6.3 50484 20 pol.
Fusible a act. ret. +1 / Cables plat +1 / lm=2100mm
Fuse slow =RONST02 Ribbon cable =RONST02
3 Sicherung traeg -A1/F2 1.6 8935 In=T 2.0A Dm=5x20 19 Kabel Empfaenger -W13 6.6 106111 2 pol mit Stecker
Fusible a act. ret. +1 / Cables recepteur +1 / lm=2200mm
Fuse slow =RONST02 Cable receiver =RONST02
4 Sicherung traeg -A1/F3 1.6 8935 In=T 2.0A Dm=5x20 20 Kabel Sender -W14 6.6 106112 2 pol mit Stecker
Fusible a act. ret. +1 / Cables transmetteur +1 / lm=1000mm
Fuse slow =RONST02 Cable transmitter =RONST02
5 Frequenzumrichte u. Parameter -G1 1.2 135202V1 1x200-230V; 50/60Hz; 1.5kW 21 ZF-Durchgangsklemme v. oben,4L -X1. 3.0 52120 4 x 2.5mm2
Conv.de freq. et paramètre +1 / Borne +1 /
Freq.converter and parameters =RONST02 Terminal =RONST02
6 Dreiphasen Frequenzumrichter -G1 1.2 50625 Un=230VAC 50/60Hz Pn=1,5kW 22 Abschlusswand 4L -X1. 3.0 52124
Convertisseur de frequence +1 / Ua=3x0-230VAC Plaque de fermeture +1 /
Frequency converters =RONST02 End cover plate =RONST02
7 | oder -G1 1.2 oder 23 ZF Schutzleiterklemme isol.;4L -X1. 3.0 52122 4 x 2,5mm2
|--------- ou--------| +1 / Borne de terre +1 /
or | =RONST02 Earth terminal =RONST02
8 Frequenzumrichte u. Parameter -G1 1.2 135203V1 1x380-460V; 50/60Hz; 1.5kW 24 Endklammer für TS35 -X1. 3.0 52131
Conv.de freq. et paramètre +1 / Piece finale +1 /
Freq.converter and parameters =RONST02 End piece =RONST02
9 Dreiphasen Frequenzumrichter -G1 1.2 50626 Un=400VAC 50/60Hz Pn=1,5kW 25 Dreiphasen-Netzfiter -Z1 1.2 50628 Un=400VAC 50/60Hz
Convertisseur de frequence +1 / Ua=3x0-400VAC Filtre au reseau thriphase +1 / In=8 Amp.
Frequency converters =RONST02 Threephase mains filter =RONST02
11 Hilfschalterbaustein -K1M 3.4 50359 2xS 27 Dreiphasen-Netzfiter -Z1 1.2 50627 Un=240VAC 50/60Hz
Module de contacts auxiliaires +1 / Filtre au reseau thriphase +1 / In=6 Amp.
Contact component auxiliary =RONST02 Threephase mains filter =RONST02
14 Zeitrelais (abfallverzögert) -K3T 3.7 50604 Usp.=24-240 VAC/DC 30 Drehknopf -G1 6.4 50483 d=65mm
Relais temporise +1 / t= Bouton tournant +2 /
Time lag relay =RONST02 Turning knob =RONST02
15 Klein Steckrelais -K4 5.1.9 50092 Usp.=24VDC 31 Impuls-Pilztaster schwarz -S1 3.5 50925
Petit relais enfichable +1 / 14 pol 4W Bouton-poussoir noir +2 /
Plug-in relay miniature =RONST02 Push-button black =RONST02
16 Stecksockel m. Loeschdiode -K4 5.1.9 50172 14 pol 32 Hilfsschalterblock 2S -S1 3.5 50927 2 x S
Socle enfichable +1 / Element de contact +2 /
Plug-in socket =RONST02 Contact element =RONST02
Plot-Datum: 31.03.2010
Änderung Datum Name Datum Name Bez. Gerätestückliste Zeichn.-Nr.: Ort: Anlage:
a 500681d GERLIST
gez. 08.11.2004 Blaser
b
Auftrag: Bl:
c Anlagenbez. 1
gepr.
d Dough-how & more. Rondostar 3000 Cutomat SFS611C Bl.
1 2 3 4 5 6 7 8 9 10
POS BENENNUNG DEUTSCH -BMK BL.PFAD ARTIKEL-NR. TECHNISCHE DATEN 1 POS BENENNUNG DEUTSCH -BMK BL.PFAD ARTIKEL-NR. TECHNISCHE DATEN 1
BENENNUNG FRANZOESISCH +ORT / TECHNISCHE DATEN 2 BENENNUNG FRANZOESISCH +ORT / TECHNISCHE DATEN 2
BENENNUNG ENGLISCH =ANLAGE AUFTRAGS-NR. BEMERKUNGEN BENENNUNG ENGLISCH =ANLAGE AUFTRAGS-NR. BEMERKUNGEN
33 Impuls-Pilztaster schwarz -S2 3.6 50925 49 Endschalter -S10 3.1 9371 Umax.=250VAC Imax.=15A
Bouton-poussoir noir +2 / Commutateur de fin de course +3 /
Push-button black =RONST02 Limit switch =RONST02
34 Hilfsschalterblock 2S -S2 3.6 50927 2 x S 50 Endschalter -S11 3.1 9371 Umax.=250VAC Imax.=15A
Element de contact +2 / Commutateur de fin de course +3 /
Contact element =RONST02 Limit switch =RONST02
35 Impuls-Pilztaster rot -S3 3.2 50926 rot 51 Steckdoseneinsatz -X10S 5.7 50315 4 pol.+ E
Bouton-poussoir rouge +2 / Insert de prise femelle +3 / Ub=220V Ib=10A
Push-button red =RONST02 Socket insert =RONST02
37 Lichts. Empfaengerkopf -B1 6.6 11334 53 Enthalten in Artikel Nr. 35493 -Y1 2.4 in/35493
Tete de recepteur +3 / Contenir dans article no.35493 +3 /
Receiver head =RONST02 Contain in item nr.35493 =RONST02
38 Lichts. Senderkopf -B2 6.6 11335 54 Elektromagnetkupplung -Y2 5.9 106114T01 Ub=24VDC
Tete de transmetteur +3 / Embrayage magnetique +3 /
Transmitter head =RONST02 Clutch magnetic =RONST02
Plot-Datum: 31.03.2010
Änderung Datum Name Datum Name Bez. Gerätestückliste Zeichn.-Nr.: Ort: Anlage:
a 500681d GERLIST
gez. 08.11.2004 Blaser
b
Auftrag: Bl:
c Anlagenbez. 2
gepr.
d Dough-how & more. Rondostar 3000 Cutomat SFS611C Bl.
1 2 3 4 5 6 7 8 9 10
Kabelname Sachnummer Adern x Querschnitt / Laenge Ziel 1 Ader Ziel 2
------Netzkabel 121017T06(EU,
121038T02(UL)-----------------------------------------------------------------
W1 12753 4 1.50
L1 1 =RONST02+3-Q1:1
L2 2 =RONST02+3-Q1:3
L3 3 =RONST02+3-Q1:5
PE gegn =RONST02+3-Q1.:PE
------Netzverbindungskabel 121017T04-----------------------------------------------------------------------
W2 12753 4 1.50
=RONST02+1-X1:L1 1 =RONST02+3-Q1:2
=RONST02+1-X1:L2 2 =RONST02+3-Q1:4
=RONST02+1-X1:L3 3 =RONST02+3-Q1:6
=RONST02+1-X1:PE gegn =RONST02+3-Q1.:PE
------Kabel zu Netzfilter-----------------------------------------------------------------------------------
W2.1 12753 4 1.50
=RONST02+1-Z1:L1 1 =RONST02+1-X1:L1
=RONST02+1-Z1:L2 2 =RONST02+1-X1:L2
=RONST02+1-Z1:L3 3 =RONST02+1-X1:L3
=RONST02+1-Z1:PE gegn =RONST02+1-X1:PE
------Motor Hauptantrieb 125056T01-------------------------------------------------------------------------
W3 13727 4+S 1.50/S
=RONST02+3-M1:V 1 =RONST02+1-K2M:3
=RONST02+3-M1:U 2 =RONST02+1-K2M:1
=RONST02+3-M1:W 3 =RONST02+1-K2M:5
=RONST02+3-M1:PE gegn =RONST02+1-X1:PE
=RONST02+3-M1:PE sld =RONST02+1-X1:PE
------Verb. Kabel FU nach K2M-------------------------------------------------------------------------------
W3.1 12753 4 1.50
=RONST02+1-K2M:2 1 =RONST02+1-G1:U
=RONST02+1-K2M:4 2 =RONST02+1-G1:V
=RONST02+1-K2M:6 3 =RONST02+1-G1:W
gegn
------Motor Walzenzustellung 124605------------------------------------------------------------------------
W4 13616 7 1.00
=RONST02+3-M2:U 1 =RONST02+1-X4:1
=RONST02+3-M2:V 2 =RONST02+1-X4:2
=RONST02+3-M2:W 3 =RONST02+1-X4:3
=RONST02+3-Y1:2 4 =RONST02+1-X4:4
=RONST02+3-Y1:1 5 =RONST02+1-X4:5
6
=RONST02+3-M2:PE gegn =RONST02+1-X4:6
------Mehlstreuer 121017T01--------------------------------------------------------------------------------
W5 12753 4 1.50
=RONST02+3-M3:U 1 =RONST02+1-X3:1
=RONST02+3-M3:V 2 =RONST02+1-X3:2
Plot-Datum: 31.03.2010
Änderung Datum Name Datum Name Bez. KABELLISTE Zeichn.-Nr.: Ort: Anlage:
a 500681d KABEL
gez. 07.07.2004 Blaser
b
Auftrag: Bl:
c Anlagenbez. 1
gepr.
d Dough-how & more. Rondostar 3000 Cutomat SFS611C Bl.
1 2 3 4 5 6 7 8 9 10
Kabelname Sachnummer Adern x Querschnitt / Laenge Ziel 1 Ader Ziel 2
=RONST02+3-M3:W 3 =RONST02+1-X3:3
=RONST02+3-M3:PE gegn =RONST02+1-X3:4
------Teighaspel 124593------------------------------------------------------------------------------------
W6 13070 2 1.00
=RONST02+3-X1:4 1 =RONST02+1-X10:1
=RONST02+3-X1:3 2 =RONST02+1-X10:2
------Kupplung 125931T01-----------------------------------------------------------------------------------
W7 13070 2 1.00
=RONST02+1-X10:4 1 =RONST02+3-Y2:2
=RONST02+1-X10:3 2 =RONST02+3-Y2:1
------Kabel zu Tasten 131850-------------------------------------------------------------------------------
W8 13259 5 1.00
=RONST02+1-X1:4 1 =RONST02+2-S2:24
=RONST02+1-X1:6 2 =RONST02+2-S2:13
=RONST02+1-X1:2 3 =RONST02+2-S3:11
=RONST02+1-X1:3 4 =RONST02+2-S1:14
------Kabel zu Tasten 131850-------------------------------------------------------------------------------
W8 13259 5 1.00
=RONST02+1-X1:5 5 =RONST02+2-S1:24
------Tasten Verbindungskabel 124609-----------------------------------------------------------------------
W8.1 13069 2 0.75
=RONST02+2-S1:13 1 =RONST02+2-S2:13
=RONST02+2-S1:24 2 =RONST02+2-S2:14
------Steuerkabel Umrichter 125932-------------------------------------------------------------------------
W9 13031 7 0.75
=RONST02+1-X6:2 1
=RONST02+1-X6:3 2 =RONST02+1-G1:S1
=RONST02+1-X6:4 3
=RONST02+1-X6:5 4
=RONST02+1-X6:6 5 =RONST02+1-G1:MB
=RONST02+1-X6:7 6
gegn
------Speisung Prozessor 124606----------------------------------------------------------------------------
W11 13448 5 0.75
=RONST02+2-X5:1 1 =RONST02+1-X2:1
=RONST02+2-X5:2 2 =RONST02+1-X2:2
=RONST02+2-X5:4 3 =RONST02+1-X2:4
=RONST02+2-X5:5 4 =RONST02+1-X2:5
=RONST02+2-X5:3 gegn =RONST02+1-X2:3
------Schutzgitter------------------------------------------------------------------------------------------
W12 13069 2 0.75
=RONST02+1-X1:1 1 =RONST02+3-S10:13
=RONST02+1-X1:2 2 =RONST02+3-S11:13
Plot-Datum: 31.03.2010
Änderung Datum Name Datum Name Bez. KABELLISTE Zeichn.-Nr.: Ort: Anlage:
a 500681d KABEL
gez. 07.07.2004 Blaser
b
Auftrag: Bl:
c Anlagenbez. 2
gepr.
d Dough-how & more. Rondostar 3000 Cutomat SFS611C Bl.
0 1 2 3 4 5 6 7 8 9
RONDO Burgdorf AG
A Heimiswilstrasse 42 A
CH-3400 Burgdorf
Tel.: +41 (0)34 420 81 11
Fax: +41 (0)34 420 81 99
Webseite: www.rondo-online.com
E-mail: service a ch.rondo-online.com
B B
E E
31.03.2010
Plot-Datum:
L3 +2 E2
A A
1
-X5 +2
14
13
15
PE -X2
gegn
2
1 3 5
1
-K1M W11
2
3
gegn
1
W2.1 /3.4 2 4 6
14
13
15
Grundmodul
-A1 -X2 -X7
PE
L2
L3
L1
-Z1 Module de base
1
TB4
TB3
TB2
TB1
B Basic module B
gegn
-G1
2
3
1
PE
L2
L3
L1
W2 +24/2.0
2
W9 +
+
2
FS S1 X6-3/4.0 L1 -A1/F1 C1
1 460 10
3
2 4 6
3G3JV
X6-4/4.0
0,63AT
S2
Typ
1,5k
1 400
J7
-X1
Typ
-R2 R1
4
230 10V/0,6A
S3 X6-5/4.0
+3 MINI D11
PE
1 200 11
YASKAWA
FR
1
SYSDRIVE
-Q1 -A1/F2
OMRON
SC X6-2/4.0 13
C 1 3 5
3
C
2,0AT
VS
5
1K Ohm
4.0--6.3 19V/1,25A
A +3 X6-6/4.0
6,3 MB 14 D12
-R1 + R2
-A1/F3 +
6
17
U
V
W
MC X6-7/4.0
2,0AT
C2 C3
SW7 SW8 26V/1,6A
GND/2.0
2
3
-X1
1
OFF ON 2 0 18
W3.1
PNP NPN V I 2 X10
D 2 4 6 71 VA D
3
-K2M L1/2.0
3
PE
/3.9 1 3 5 4
L2/2.0
-X1 5 4
L3/2.0
6 5
6
-X1
gegn
L17/5.0
gegn
L18/5.0
2
3
1
sld
W1
2
3
1
E W3 E
L1
L2
L3
PE
Hauptschalter Steuerspannungstransformator
31.03.2010
A A10 A6 A7 A8 A9 A
+2 +2 +2 +2 +2
11
10
-X2 -X2 -X2 -X2 -X2
10
11
8
7
9
-X7 -X7 -X7 -X7 -X7
+24/1.9 +24/3.0
B B
3 3 3
D5 K5 K7 D7 D6 K6
2 2
4 2 4 4
D14
GND/1.9 GND/3.0
C L1/1.9 C
L2/1.9
L3/1.9
7 8 9 10 9 8 7 10
K1 D1 K3
1 4 2 5 3 6 11 3 6 2 5 1 4 11 D3
D 6 3 5 2 4 1 10 4 1 5 2 6 3 10
D
D2
D4
K2 K4
9 8 7 11 7 8 9 11
2
3
6
2
3
4
-X4 -X4
1
1
-X3
-X4 -X4 -X3
1
2
3 3
gegn 6
1
2
3
4
2
2
3
1
gegn
E W4 W5 E
U V W PE U V W PE
230/400V 0,85/0,48A / 50Hz 1 220/400V 0,5/0,3A / 50Hz
M M
+3 230/400V 0,8/0,46A / 60Hz +3 +3 254/440V 0,5/0,3A / 60Hz
3~ 0,090 kW -Y1 2 3~ 0.090 kW
-M2 -M3
1410/1700 U/min 1500/1800 U/min
E7 E5 E3
A A0 A
+2 +2 +2 +2
20
18
16
-X2 -X2 -X2 -X2
20
18
16
1
-X7 -X7 -X7 -X7
B +24/2.9 +24/4.0 B
3
RE4: 3s 15 (gelbe Skala)
K8 D8
2 4 RE7: 3s 50%
A1-A2
R3
Y1-Z2
C 15-18
C
H1
t t=1,5s
D15 LED
GND/2.9 GND/4.0
4
3
-X5
1
-X5
1
3
D P1/4.7 D
P1-2/5.1
2
4
63 53 14
-X1 -X1 -X1
-K1M -K1M 21 -K1M 15 -K3T
-X1 64 54 13
.4 .4 -K2M .4 .7
3
1
W8 .9 22 18 16
1
-X1.
2
11
6
+2 +2 14 +2 +2 14
2
24 24
1
-X1
E W12 +2 -S1 -S1 -S2 -S2 E
A1 A1
13 13 -S3 12 .5 13 .5 13 .7 13 .6 13
2
0
14 14
A2 B2 Z1 Z2 -X1
15
Grille de protection Contacteur principal pour 3 4
/1.4
Mise en marche machine 16 .9 3 4
/1.2
Commande principale
Safety guard Main contactor for 5 6 Start machine 5 6 Main drive
/1.4 /1.2
links rechts AUS Netzeinspeisung EIN 13 14 Teig nach rechts Teig nach links 21 22
.8 .4
Plot-Datum:
left right OFF Mains supply ON 63 64 Dough to the righte Dough to the left 63 64
.3 /4.7
Änderung Datum Name Datum Name Bez. Zeichn.-Nr.: Ort: Anlage:
a 32357 03.09.01 Spahr 500681d 1 RONST02
gez. 22.09.97 Ryser
b
Auftrag: Bl:
c 32370 25.10.02 Blaser
Anlagenbez. 3
gepr.
d Dough-how & more. Rondostar 3000 Cutomat SFS611C Bl.
0 1 2 3 4 5 6 7 8 9
-24/3.9 -24/5.0
+24-A/3.9 +24-A/5.0
E4
A A2 A11 A
+2 +2 +2
12
17
-X2 -X2 -X2
12
21
3
-X7 -X7 -X7
B +24/3.9 +24/5.0 B
3 3
K9 K13
D9 4 2 4 2
3
K10
D10
4 2
C C
GND/3.9 GND/5.0
-X6
3
7
1
-X6
3
7
D D
5
7
-X5
8
5
8
2
6
1
X6-3/1.3
X6-4/1.3
X6-5/1.3 64
X6-2/1.3 -K2M
/3.9 63
E X6-7/1.3 E
X6-6/1.3
P1/3.9
P0/3.9
Hauptantrieb
31.03.2010
Commande principale
Main drive
Plot-Datum:
E6
A A4 A5 A1 A3 A
+2 +2 +2 +2 +2
21
4
-X2 -X2 -X2 -X2 -X2
4
-X7 -X7 -X7 -X7
3
B +24/4.9 K14 B
2 4
X81
-D13
K14 D18 K13 D21 K11 D20 K12 D19
X82
5 7 4 2
K11
C 6 3 C
5 7 4 2 D23
K12
6 3
GND/4.9
L17/1.9
D L18/1.9 D
4
-X10 -X10 -X10
1
-X10
3
-X5
20
9
3
-X5
2
4
9
2
1
1
20
4
slow speed start sheeting
+3
E -X10S
24 VDC E
1
1,6 A
3
+3
21
M
200 N
-Y2 2
braun blau +3
Transfer schnell/langsam transfere vite/lente Transfer fast/slow -G1
4
21
Embrayage Convertisseur de fréquence Enrouleur à pâte Enrouleur à pâte / Embrayage Enrouleur à pâte Embrayage
Clutch Frequency converter Dough reeler Dough reeler Clutch Dough reeler Clutch
E6
A A4 A5 A1 A3 A
+2 +2 +2 +2 +2
21
4
-X2 -X2 -X2 -X2 -X2
4
-X7 -X7 -X7 -X7
3
B +24/4.9 K14 B
2 4
X81
-D13
K14 D18 K13 D21 K11 D20 K12 D19
X82
5 7 4 2
K11
C 6 3 C
5 7 4 2 D23
K12
6 3
GND/4.9
L17/1.9
D L18/1.9 D
4
-X10 -X10 -X10
1
-X10
3
-X5
9
3
-X5
9
violett
weiss
20
3
4
A1
+3
E -X10S
24 VDC -K4 E
1,6 A A2
M
200 N
4
braun' blau +3
22
23
-K4
22
-G1
21
P1-2/3.1
Teighaspel Teighaspel
21
GND
Sig.
Basic module Light barrier
+
-
-W13
W11
-W14
-W12
weiss
braun
58
59
60
61
2
3
4
4
1
B B
rot
C C
D D
E E
31.03.2010
SMB_F26_001
RONDO Burgdorf AG
Heimiswilstrasse 42
CH-3400 Burgdorf
Tel.: +41 34 420 81 11
Fax: +41 34 420 81 99
Website: www.rondo-online.com
E-mail: service@ch.rondo-online.com
Company / customer
City
+Drahtfarben/1
Date 26.05.2011 Page name Plant designation Machine number == aaDoc
e 40655 01.02.2011 sturze_m Ed. by sturze_m Titel-/Deckblatt SFS611 = aaDOC
Appr Title page/cover sheet Drawing number Commission number + Deckblatt
Modification Date Name Original Page de titre/de garde 500681e Total Pg 27 Page 1
0 1 2 3 4 5 6 7 8 9
functional assignment Higher-level function Mounting location Page Page description Modification Date Edited by
Index Modification number Modification date
==aaDoc =aaDOC +Deckblatt 1 Titel-/Deckblatt 26.05.2011 sturze_m
Title page/cover sheet e 40655 01.02.2011
Page de titre/de garde
Index Modification number Modification date
=aaDOC +Drahtfarben 1 Drahtfarben 26.05.2011 sturze_m
Wire colours
Colours de fil
Index Modification number Modification date
==S1 =02 +1A 1 Einspeisung / Antriebe 26.05.2011 sturze_m
Power Supply / Drives
Alimentation / Entraînements
Index Modification number Modification date
=02 +1A 2 Hauptantrieb 26.05.2011 sturze_m
Main drive E 40655 01.02.2011
Commande principale
Index Modification number Modification date
=02 +1A 3 Steuerung 26.05.2011 sturze_m
Control
Commande
Index Modification number Modification date
=02 +1A 4 Steuerung 26.05.2011 sturze_m
Control
Commande
Index Modification number Modification date
=02 +1A 5 Steuerung 26.05.2011 sturze_m
Control
Commande
Index Modification number Modification date
=02 +1A 5a Steuerung 26.05.2011 sturze_m
Control
Commande
Index Modification number Modification date
=02 +2 6 Prozessoreinheit 26.05.2011 sturze_m
Microprocessor unit
Unite microprocesseur
Index Modification number Modification date
==zzDoc =zzDOC +Artikel 1 Artikelstückliste 26.05.2011 sturze_m
Parts list
Liste d'articles
Index Modification number Modification date
=zzDOC +Artikel 2 Artikelstückliste 26.05.2011 sturze_m
Parts list
Liste d'articles
Index Modification number Modification date
=zzDOC +Artikel 3 Artikelstückliste 26.05.2011 sturze_m
Parts list
Liste d'articles
Index Modification number Modification date
=zzDOC +Artikel 4 Artikelstückliste 26.05.2011 sturze_m
Parts list
Liste d'articles
Index Modification number Modification date
=zzDOC +Artikel 5 Artikelstückliste 26.05.2011 sturze_m
Parts list
Liste d'articles
+Drahtfarben/1 2
Date 26.05.2011 Page name Plant designation Machine number == aaDoc
Ed. by sturze_m Inhaltsverzeichnis SFS611 = aaDOC
Appr Table of contents Drawing number Commission number + Inhaltsverz
Modification Date Name Original Sommaire 500681e Total Pg 27 Page 1
0 1 2 3 4 5 6 7 8 9
functional assignment Higher-level function Mounting location Page Page description Modification Date Edited by
Index Modification number Modification date
==zzDoc =zzDOC +Kabel 1 Kabelplan 26.05.2011 sturze_m
Cable diagram
Plan de câblage
Index Modification number Modification date
=zzDOC +Kabel 2 Kabelplan 26.05.2011 sturze_m
Cable diagram
Plan de câblage
Index Modification number Modification date
=zzDOC +Kabel 3 Kabelplan 26.05.2011 sturze_m
Cable diagram
Plan de câblage
Index Modification number Modification date
=zzDOC +Kabel 4 Kabelplan 26.05.2011 sturze_m
Cable diagram
Plan de câblage
Index Modification number Modification date
=zzDOC +Kabel 5 Kabelplan 26.05.2011 sturze_m
Cable diagram
Plan de câblage
Index Modification number Modification date
=zzDOC +Kabel 6 Kabelplan 26.05.2011 sturze_m
Cable diagram
Plan de câblage
Index Modification number Modification date
=zzDOC +Klemmen 1 Klemmenaufreihplan 26.05.2011 sturze_m
Terminal line-up diagram
Plan des bornes associables
Index Modification number Modification date
=zzDOC +Stecker 1 Steckerplan 26.05.2011 sturze_m
Plug diagram
Plan des connecteurs
Index Modification number Modification date
=zzDOC +Stecker 2 Steckerplan 26.05.2011 sturze_m
Plug diagram
Plan des connecteurs
Index Modification number Modification date
=zzDOC +Stecker 3 Steckerplan 26.05.2011 sturze_m
Plug diagram
Plan des connecteurs
Index Modification number Modification date
=zzDOC +Stecker 4 Steckerplan 26.05.2011 sturze_m
Plug diagram
Plan des connecteurs
1 ==S1=02+1A/1
Date 26.05.2011 Page name Plant designation Machine number == aaDoc
Ed. by sturze_m Inhaltsverzeichnis SFS611 = aaDOC
Appr Table of contents Drawing number Commission number + Inhaltsverz
Modification Date Name Original Sommaire 500681e Total Pg 27 Page 2
0 1 2 3 4 5 6 7 8 9
-A1
-T1
-X1:1 460 1
-F1 2 X2_4:15VDC
400 X2_5:GAC
T 0.63A
2 230
-F2 2
-X1 L1 L2 L3 PE 200 1 X2_2:24VDC
X2_1:GAC
-W2 T 2A
4x1,5 1 2 3 GNYE
6 1
-F3 2 26VAC
-PE GDC
PE T 2A
0
PE
Steuerspannungstransformator
Control voltage trans
1 3 5
Transformateur de tension de com
+3-Q1
4,0 - 6,3A 1 3 5
-----------
-W2.1
I> I> I> -K1M
6,3A PE 4x1,5 1 2 3 GNYE
/3.4 2 4 6
2 4 6
3
4
5
-Z1 PE PE
-X4:1 2 3 6 4 5 -X3:1 2 3 4
-L1
-L2
-L3
-PE
3x480VAC
10A
-PE
-L1
-L2
-L3
-W1_UL
4x2,08 SW WS RT GN PE PE PE
-W1
4x1,5 1 2 3 GNYE -W4 -W4.1 -W5
4x0,75 1 2 3 GNYE 2x0,75 1 2 4x1,5 1 2 3 GNYE
+EXT-X10P 1 2 3 PE 4 5 6 PE U1 V1 W1 PE 1 U1 V1 W1 PE
+3-Y5
2.0 / FU_L1
2.1 / FU_L2
2.1 / FU_L3
2.1 / FU_PE
+3-M2
M 2 +3-M3
M
220/400V;0.85/0.48A;50Hz 3 220/400V;0.5/0.3A;50Hz 3
254/440V;0.8/0.46A;60Hz 254/440V;0.5/0.3A;60Hz
3x200-460V 0.09kW 0.09kW
50/60Hz 1410U/1700/min 1500U/1800/min
==aaDoc=aaDOC+Inhaltsverz/2 2
Date 26.05.2011 Page name Plant designation Machine number == S1
Ed. by sturze_m Einspeisung / Antriebe SFS611 = 02
Appr Power Supply / Drives Drawing number Commission number + 1A
Modification Date Name Original Alimentation / Entraînements 500681e Total Pg 27 Page 1
0 1 2 3 4 5 6 7 8 9
-FU_PE / 1.4
-FU_L1 / 1.3
-FU_L2 / 1.3
-FU_L3 / 1.4
X6-3 / 4.0
2 1
X6-4 / 4.0
-R1
X6-5 / 4.0 5kOhm 3
PE
X6-6 / 4.0
-G1 PE
R/L1 S/L2 T/L3 STF STR RH RM RL MRS RES SD PC SD SD 10 2 4 5
-W3.1 -W9 6
4x1,5 1 2 3
1 3 5
-K2M
4.0 / X6-7
/3.8 2 4 6
-X1 PE
PE
-W3
4x1,5 1 2 3 GNYE SH
U1 V1 W1 PE
+3-M1
M
230/400VAC; 50/60HZ 3
3.5/2.0A; 1.1kW
Bandantrieb
Belt drive
Entrainm. du tapis
1 3
Date 26.05.2011 Page name Plant designation Machine number == S1
E 40655 01.02.2011 sturze_m Ed. by sturze_m Hauptantrieb SFS611 = 02
Appr Main drive Drawing number Commission number + 1A
Modification Date Name Original Commande principale 500681e Total Pg 27 Page 2
0 1 2 3 4 5 6 7 8 9
+2-A2
24VDC
15VDC
PE
+
+
-
-
-X5:1 2 4 5 3 -X2
PE
-W11 -W15 1-20
5x0,75 1 2 3 4 GNYE
-A1
-X2:1 2 4 5 3 -X7
-PE
-X5:1 4 2 2
-X1 1
3.1 / X1_1 P1 / 4.0
-W12 -W8
2x0,75 1 5x1,0 3
63 53 21 -X1 5 3 4
-X1 2 -K1M -K1M -K2M
11 /3.4 64 /3.4 54 /3.8 22
13 -W8 5 -W8 4 -W8 1
+2-S3 15
5.1 / P1-2
3.7 / X1_1
+3-S10 12 -K3T
14 /3.7 18 16
-W8.1
-X1 6
-S3_12 / 3.2
2
13 23 13 23
-W12 2 -W8 2 A1 B1 X1 Y1 14
A1 +2-S1 +2-S2 A1
-K3T -K1M
-K1M 14 24 14 24 A2 B2 Z1 Z2 /3.4 13
-K2M
24V /3.8 24V
A2 A2
3.6 / S3_12
14
-W8.1
2x0,75
+3-S11
1
13
P0 / 4.0
-X1 0
2 4
Date 26.05.2011 Page name Plant designation Machine number == S1
Ed. by sturze_m Steuerung SFS611 = 02
Appr Control Drawing number Commission number + 1A
Modification Date Name Original Commande 500681e Total Pg 27 Page 3
0 1 2 3 4 5 6 7 8 9
-A1
/1.5
-X6:2 3 4 5 6 7 -X5:7 8
2.5 / -X6-2
2.5 / -X6-3
64
2.5 / -X6-4 -K2M
/3.8 63
2.5 / -X6-5
2.9 / -X6-6
2.9 / -X6-7
3.9 / -P0
3.9 / -P1
Hauptantrieb
Main drive
Commande principale
Frequenzumrichter
Frequency converter
Convertisseur de fréquence
3 5
Date 26.05.2011 Page name Plant designation Machine number == S1
Ed. by sturze_m Steuerung SFS611 = 02
Appr Control Drawing number Commission number + 1A
Modification Date Name Original Commande 500681e Total Pg 27 Page 4
0 1 2 3 4 5 6 7 8 9
-A1
PE
-X5:9 -X10:1 2 4 3
20 20 4
-W6 -W7
2x1 1 2 2x1,0 1 2
3 2 4
-X10S 4 3
24VDC
1.6A 1
4 3 200N +3-Y2
2
21 21
3.0 / P1-2
(Z)
4 5a
Date 26.05.2011 Page name Plant designation Machine number == S1
Ed. by sturze_m Steuerung SFS611 = 02
Appr Control Drawing number Commission number + 1A
Modification Date Name Original Commande 500681e Total Pg 27 Page 5
0 1 2 3 4 5 6 7 8 9
-A1
PE
-X5:9 -X10:1 2 4 3
20
3 3
-X10S 4 3
violett
weiss
-X10P 4 3
blue M brown
24VDC
1.6A A1
4 4 200N -K4
A2
22 23
-K4
22
21
/ P1-2
24
21
/5a.8
5 +2/6
Date 26.05.2011 Page name Plant designation Machine number == S1
Ed. by sturze_m Steuerung SFS611 = 02
Appr Control Drawing number Commission number + 1A
Modification Date Name Original Commande 500681e Total Pg 27 Page 5a
0 1 2 3 4 5 6 7 8 9
+Ma-G2 +Ma-G1
Absolutwertgeber Handrad
Rotary Encoder Turning knob
Codeur en valeur absolute Bouton tourant
1 1
+Ma-B2 +Ma-B1
2 2
-W15 -W10
10x0,25 1-10 5x0,25 1-5
-W14 -W13
4x1,5 br ws 4x1,5 br ws
60 61 59 58
1 2 1 2
-A2
+ - GND Sig.
Empfängerkopf Lichtschranke
Receiver head Light barrier
Tête de récepteur Relais photoelectrique
Senderkopf Lichtschranke
Transmitter head Light barrier
Tête de transmetteur Relais photoelectrique
Prozessoreinheit
Microprocessor unit
Unite microprocesseur
Prozessoreinheit
Microprocessor unit
Unite microprocesseur
+1A/5a ==zzDoc=zzDOC+Artikel/1
Date 26.05.2011 Page name Plant designation Machine number == S1
Ed. by sturze_m Prozessoreinheit SFS611 = 02
Appr Microprocessor unit Drawing number Commission number + 2
Modification Date Name Original Unite microprocesseur 500681e Total Pg 27 Page 6
0 1 2 3 4 5 6 7 8 9
==S1 Grundmodul
==S1=02+1A-A1 ==S1=02+1A/1.5 50477 Basic module
Module de base
==S1 Trafomodul
==S1=02+1A-A1-T1 ==S1=02+1A/1.7 50643 transformer module
Module transformateur
==S1 oder
==S1=02+1A-G1 ==S1=02+1A/2.0 oder or
ou
==S1 oder
==S1=02+1A-G1 ==S1=02+1A/2.0 oder or
ou
==S1 oder
==S1=02+1A-G1 ==S1=02+1A/2.0 oder or
ou
==S1=02+2/6 2
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Artikelstückliste SFS611 = zzDOC
Appr Parts list Drawing number Commission number + Artikel
Modification Date Name Original Liste d'articles 500681e Total Pg 27 Page 1
0 1 2 3 4 5 6 7 8 9
==S1 oder
==S1=02+1A-G1 ==S1=02+1A/2.0 oder or
ou
==S1 oder
==S1=02+1A-G1 ==S1=02+1A/2.0 oder or
ou
==S1 Hilfskontaktblock 2S
==S1=02+1A-K1M ==S1=02+1A/3.4 50359 Contact component 2S
Module de contacts auxiliaires
==S1 Hilfskontaktblock 2S
==S1=02+1A-K2M ==S1=02+1A/3.8 50359 Contact component 2S
Module de contacts auxiliaires
1 3
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Artikelstückliste SFS611 = zzDOC
Appr Parts list Drawing number Commission number + Artikel
Modification Date Name Original Liste d'articles 500681e Total Pg 27 Page 2
0 1 2 3 4 5 6 7 8 9
==S1 Steckdoseneinsatz 4p+PE 5-polig mit PE; IEC: Ub=400V Ib=23A; UL: Ub=600V
==S1=02+1A-X10S 50315 Socket insert 4p+PE Ib=10A
Insert de prise femelle 4p+PE
==S1 Steckdoseneinsatz 4p+PE 5-polig mit PE; IEC: Ub=400V Ib=23A; UL: Ub=600V
==S1=02+1A-X10S 50315 Socket insert 4p+PE Ib=10A
Insert de prise femelle 4p+PE
==S1 Prozessoreinheit
==S1=02+2-A2 ==S1=02+1A/3.3 50587 Microprocessor unit
Unite microprocesseur
==S1 Hilfsschalterblock
==S1=02+2-S1 ==S1=02+1A/3.5 50927 Contact component auxiliary
Module de contacts auxiliaires
==S1 Hilfsschalterblock
==S1=02+2-S2 ==S1=02+1A/3.6 50927 Contact component auxiliary
Module de contacts auxiliaires
==S1 Hilfsschalterblock
==S1=02+2-S3 ==S1=02+1A/3.2 50928 Contact component auxiliary
Module de contacts auxiliaires
2 4
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Artikelstückliste SFS611 = zzDOC
Appr Parts list Drawing number Commission number + Artikel
Modification Date Name Original Liste d'articles 500681e Total Pg 27 Page 3
0 1 2 3 4 5 6 7 8 9
==S1 oder
==S1=02+3-M1 ==S1=02+1A/2.0 oder or
ou
3 5
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Artikelstückliste SFS611 = zzDOC
Appr Parts list Drawing number Commission number + Artikel
Modification Date Name Original Liste d'articles 500681e Total Pg 27 Page 4
0 1 2 3 4 5 6 7 8 9
==S1 Handrad
==S1=02+Ma-G1 ==S1=02+2/6.3 50481 Turning knob
Bouton tourant
==S1 Absolutwertgeber
==S1=02+Ma-G2 ==S1=02+2/6.1 50482 Rotary Encoder
Codeur en valeur absolute
4 +Kabel/1
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Artikelstückliste SFS611 = zzDOC
Appr Parts list Drawing number Commission number + Artikel
Modification Date Name Original Liste d'articles 500681e Total Pg 27 Page 5
0 1 2 3 4 5 6 7 8 9
+Artikel/5 2
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Kabelplan SFS611 = zzDOC
Appr Cable diagram Drawing number Commission number + Kabel
Modification Date Name Original Plan de câblage 500681e Total Pg 27 Page 1
0 1 2 3 4 5 6 7 8 9
GNYE
1 3
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Kabelplan SFS611 = zzDOC
Appr Cable diagram Drawing number Commission number + Kabel
Modification Date Name Original Plan de câblage 500681e Total Pg 27 Page 2
0 1 2 3 4 5 6 7 8 9
Cable name ==S1=02+1A-W6 Cable type H05VV5-F UL-CSA-HAR oil resist. Part number 124593
Remark No. of conductors 2 Cross-section 1 mm² Cable length
Seite / Spalte Anschluss Zielbezeichnung von Ader Zielbezeichnung nach Anschluss Seite / Spalte
Page / column Connection point Target designation from Conductor Target designation to Connection point Page / column
Page / Colonne Raccordement Désignation de destination de Conducteur Désignation de destination vers Raccordement Page / Colonne
2 4
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Kabelplan SFS611 = zzDOC
Appr Cable diagram Drawing number Commission number + Kabel
Modification Date Name Original Plan de câblage 500681e Total Pg 27 Page 3
0 1 2 3 4 5 6 7 8 9
GNYE
/2.7 SH SH PE /2.7
3 5
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Kabelplan SFS611 = zzDOC
Appr Cable diagram Drawing number Commission number + Kabel
Modification Date Name Original Plan de câblage 500681e Total Pg 27 Page 4
0 1 2 3 4 5 6 7 8 9
4 6
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Kabelplan SFS611 = zzDOC
Appr Cable diagram Drawing number Commission number + Kabel
Modification Date Name Original Plan de câblage 500681e Total Pg 27 Page 5
0 1 2 3 4 5 6 7 8 9
5 +Klemmen/1
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Kabelplan SFS611 = zzDOC
Appr Cable diagram Drawing number Commission number + Kabel
Modification Date Name Original Plan de câblage 500681e Total Pg 27 Page 6
0 1 2 3 4 5 6 7 8 9
Klemmenleiste
Terminal strip ==S1=02+1A-X1
Bornier
Klemme Brücke Artikelnummer Bemerkung Seite Klemmenzubehör Abschlussplatte Brücke Endklammer für TS35
Terminal Jumper Part number Remark Page Terminal accessories End plate Jumper End piece
Borne Pont Numéro d'article Remarque Page Accessoire de borne Flasque de fin Pont Piece finale
0 52120 ==S1=02+1A/3
1 52120 ==S1=02+1A/3
2 52120 ==S1=02+1A/3
3 52120 ==S1=02+1A/3
4 52120 ==S1=02+1A/3
5 52120 ==S1=02+1A/3
6 52120 ==S1=02+1A/3
L2 52120 ==S1=02+1A/1
L3 52120 ==S1=02+1A/1
PE 52122 ==S1=02+1A/1
PE 52122 ==S1=02+1A/2
Klemmenleiste
Terminal strip ===+
Bornier
Klemme Brücke Artikelnummer Bemerkung Seite Klemmenzubehör Abschlussplatte Brücke Endklammer für TS35
Terminal Jumper Part number Remark Page Terminal accessories End plate Jumper End piece
Borne Pont Numéro d'article Remarque Page Accessoire de borne Flasque de fin Pont Piece finale
20 52120 ==S1=02+1A/5
21 52120 ==S1=02+1A/5
20 52120 ==S1=02+1A/5
21 52120 ==S1=02+1A/5
4 52120 ==S1=02+1A/5
20 52120 ==S1=02+1A/5a
22 52120 ==S1=02+1A/5a
21 52120 ==S1=02+1A/5a
23 52120 ==S1=02+1A/5a
+Kabel/6 +Stecker/1
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Klemmenaufreihplan SFS611 = zzDOC
Appr Terminal line-up diagram Drawing number Commission number + Klemmen
Modification Date Name Original Plan des bornes associables 500681e Total Pg 27 Page 1
0 1 2 3 4 5 6 7 8 9
brown 3 ==S1=02+1A/5a
+3-M4:blue 4 ==S1=02+1A/5
blue 4 ==S1=02+1A/5a
+Klemmen/1 2
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Steckerplan SFS611 = zzDOC
Appr Plug diagram Drawing number Commission number + Stecker
Modification Date Name Original Plan des connecteurs 500681e Total Pg 27 Page 1
0 1 2 3 4 5 6 7 8 9
==S1=02+1A-X10S 1
3 -A1-X10:2 ==S1=02+1A/5
4 -A1-X10:1 ==S1=02+1A/5
PE
3 -A1-X10:2 ==S1=02+1A/5a
4 -A1-X10:1 ==S1=02+1A/5a
PE
1 3
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Steckerplan SFS611 = zzDOC
Appr Plug diagram Drawing number Commission number + Stecker
Modification Date Name Original Plan des connecteurs 500681e Total Pg 27 Page 2
0 1 2 3 4 5 6 7 8 9
+3-Q1:4 2 ==S1=02+1A/1
+3-Q1:6 3 ==S1=02+1A/1
+3-Q1:2 4 ==S1=02+1A/1
+3-Q1:4 5 ==S1=02+1A/1
+3-Q1:6 6 ==S1=02+1A/1
PE PE ==S1=02+1A/1
PE PE ==S1=02+1A/1
2 4
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Steckerplan SFS611 = zzDOC
Appr Plug diagram Drawing number Commission number + Stecker
Modification Date Name Original Plan des connecteurs 500681e Total Pg 27 Page 3
0 1 2 3 4 5 6 7 8 9
===+ 3 20 ==S1=02+1A/5
4 21 ==S1=02+1A/5
2 20 ==S1=02+1A/5
3 21 ==S1=02+1A/5
4 4 ==S1=02+1A/5
3 20 ==S1=02+1A/5a
4 22 ==S1=02+1A/5a
3 20 ==S1=02+1A/5a
4 23 ==S1=02+1A/5a
3
Date 26.05.2011 Page name Plant designation Machine number == zzDoc
Ed. by sturze_m Steckerplan SFS611 = zzDOC
Appr Plug diagram Drawing number Commission number + Stecker
Modification Date Name Original Plan des connecteurs 500681e Total Pg 27 Page 4