Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Weight Transmitter PR 5230: With Display and Dosing Function Easyfill

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Weight transmitter PR 5230

With display and dosing function EasyFill®

Advantages

 Highprecision, reliable and fast


processing of weight values

 Convenient and efficient calibration


of the scale in under one minute

Global
  remote servicing with the
Remote Service functionality

 Integrated display for status


monitoring

Dosing
  function EasyFill® reduces
programming time

The weight transmitter PR 5230 processes weight values reliably and


highly accurately from silo and vessel scales with analogue and digital
load cells. The field housing enables direct and safe installation regardless
of the ambient conditions.

The versatile weight transmitter for fast, high-precision weight values

Reliable and fast processing of weight values The EasyFill® software, integrated as standard, for
with up to 120,000 increments. The integrated one-component dosing of fluids, powders and
display enables direct status monitoring. granules reduces programming time and enables
fast and flexible process changes.

‘Smart Calibration’ enables PC-based calibration The Remote Service functionality avoids
without weights. This efficiently reduces installation downtime in your production.
times to a minimum.
The weight transmitter for simple and versatile weight recording
The weight transmitter PR 5230 comes standard with three freely-configurable digital inputs and outputs. These
can be used with an application-specific limit function and associated values to avoid over and under filling. The
weight transmitter can be connected without any difficulty with an external WLAN adapter and used with its full
range of functions. An intrinsically safe load cell connection for operating load cells in ATEX Zone 1/21 is available
optionally without additional electricity-limiting barriers. For documentation and printing of weighing data or
defined configuration parameters, a printer can be connected directly to the transmitter.

Product description
Structure

Housing Display and status, LEDs

Height of housing: 150 mm Dimensions in mm

Including EasyFill® application


EasyFill® is a basic software application for one-component dosing of fluids, powders and granules with
user‑specific configurable target value, tolerance and overshoot value. Processes can be directly controlled using
the integrated digital inputs/outputs. Control for implementing simple dosing processes efficiently and easily is
guaranteed thanks to numerous options/interfaces for integration into your production network.

Simple online operation of the weight transmitter


 Display the website integrated with the device using the IP address in your
browser
 Display and change device configuration
 Calibration of a device using a range of methods
- with load cell data (‘smart calibration’)
- with weights
- with mV/V
 View and print the overall configuration
 Readout of fault memory
 Store/download a device configuration as PC file

All Minebea Intec devices at a glance


The ‘Indicator Browser’ enables all Minebea Intec transmitters, indicators and
process controllers in your network to be displayed on your PC. The software
tool is included with the product.
Assignment via IP address
There are flexible solutions for IP address allocation: either set manually by the operator, defined as an auto
IP directly by the weight transmitter PR 5230 or taken from the assigned DHCP server. If the IP address is not
known when allocating automatically, the Minebea Intec Indicator Browser included with the product enables you
to search for the right transmitters in the network.

Technical data Optionally


available for
Weight transmitter PR 5230 – precision weight recording for vessels and silos use in ATEX
Housing Housing, terminals, P66
Zone 2/22
Material Stainless steel, electro-polished
RoHS compliant
Dimensions 350 × 250 × 150 mm
Weight Net 1.45 kg
Display LCD, transflective, back-lit
Elements 6 digit
Resolution 128 x 64 pixels, graphic display can be configured
Status LEDs give an overview
Internal keys Within the housing there are 3 keys for zero, tare and test
Power supply 100 V AC to 240 V AC +10%/-15%
24 VDC, +/-20%
Power consumption 11 W
Control outputs Quantity 3
Relay outputs, passive, max. 30 VDC, max. 30 mA
Functions Limits, weight status
Control inputs Quantity 3
Optocoupler isolated, passive, max. 30 VDC, max. 10 mA
Functions Zero, tare
Remote controlled I/O The I/O can be set using internet function or by PC or field bus
Inputs and outputs Galvanically isolated from auxiliary power and sensor circuit
Load cell connection All strain gauge load cells; 6 or 4 wire connection is possible
Load cell supply 12 V, short-circuit proof, external load cell supply possible
Load impedance Min. 75 Ω
e.g. 6 load cells each with 600 Ω
or 4 load cells each with 350 Ω
Measuring principle Measuring amplifier Delta-Sigma converter
Measuring time min. 5 ms – max. 1600 ms
Sensitivity 7.5 nV (appr. 4.8 million div.)
Usable resolution 0.2 μV/d
Input signal Measuring signal 0 to 36 mV (for 100% nominal load)
Calibration approval 10,000 e, Class III in accordance with EN 45501
(In combination with remote Complies with OIML R 76
display PR 5110)
Smallest signal 0.5 μV/e
Linearity < 0.003%
Temperature effect Zero point TK0 m < 0.05 μV/K RTI
Measuring range TKspan < +/- 2.5 ppm/K
Digital filter for load cell 4th order (low pass), Bessel, aperiodic or Butterworth
connection
Ethernet interface Ethernet TCP/IP and Modbus TCP
(Functions) - Assignment of an IP address:
- AutoIP
- DHCP server assignment
- fixed input of the IP address
- Automatic detection of signal transmission with corresponding change-over (cross-over or patch cable)
- Web service via SOAP/UPnP (Simple Object Access Protocol)
- Synchronal ModBus UDP
Serial interface RS 422/485 and RS232
Protocols Remote displays, SMA, Modbus RTU, printer and Minebea Intec digital scales
(XBPI protocol)
Optional: 0/4 … 20 mA
Analogue output
Internal resolution 16 bit
PR 5230/06 (C11)
Usable step width 0.5 μA
Load impedance 500 Ω
Function freely configurable
Field bus PR 1721/4x (C2x) Profibus DP, DeviceNet, CC-Link, Profinet and Ethernet/IP
Technical data for weight transmitter PR 5230 continued
Load cell connection board For internal connection options for up to four load cells (instead of cable junction box)
PR 5230/22 (C31)
Ambient temperature Verifiable -10°C to +40°C
Industrial -10°C to +50°C
Storage -20°C to +70°C
ATEX approvals PR 5230 II 3G Ex nA nC IIC T4, SAG 09 ATEX 004 X, II 3D Ex tD A22 IP6X T80 °C
II (2)G [Ex ib] IIC, II (2)D [Ex ibD], KEMA 10 ATEX 0065 X

Ordering information
Type Description Order number

PR 5230 Weight transmitter in field housing, IP 66, stainless steel incl. Ethernet TCP/IP 9405 152 30000
and Modbus TCP, RS232, RS485/422, 3 relay outputs, 3 digital inputs, OPC
server license included

Option The options are installed


Power supply 230 VAC L0
24 VDC L8
A/D converter Load cells (strain gauge) scale connection in safe area W1
Load cells (strain gauge) intrinsically safe for scales in EX-area WE1
EX Zone ATEX Zone 2/22 Y2
Digital input | output Digital input passive (external 24 V supply required) DE1
Digital input active (internal 12 V supply) DE2

Digital output relay passive DA1

Digital output optocoupler passive DA2

Option cards SLOT 1 2 3

Analogue output 0/4–20 mA C11 X

Profibus DP C21 X

DeviceNet C24 X

CC-Link C25 X

Profinet C26 X

Ethernet/IP C27 X

Load cell connection board for up to 4 load cells C31 X


Ethernet RJ45 Ethernet connector RJ45, IP66 M39
Ethernet cable with cable gland, 7 metres, RJ45 plug M40

Accessories The accessories are enclosed


PR 5230/06 Analogue output 0/4–20 mA 9405 352 30061
PR 5230/22 Load cell connection board for up to 4 load cells (instead of a cable junction box) 9405 352 30221
PR 5230/30 Ethernet connector RJ45, IP66 9405 352 30301
PR 5230/31 Ethernet cable with cable gland, 7 metres, RJ45 plug 9405 352 30311
PR 1721/41 Profibus DP 9405 317 21411
PR 1721/44 DeviceNet 9405 317 21441
PR 1721/45 CC-Link 9405 317 21451
PR 1721/46 Profinet 9405 317 21461
PR 1721/47 Ethernet/IP 9405 317 21471

The documentation and software are supplied on CD.


Software supplied: Indicator Browser, ConfigureIt Professional, OPC Server, VNC Viewer, Modbus TCP examples
Paper versions can be ordered separately if needed.

The technical data given serves as a product description only and should Minebea Intec GmbH
not be understood as guaranteed properties in the legal sense. Meiendorfer Straße 205 A
22145 Hamburg, Germany
Specifications subject to change without notice.
Phone +49.40.67960.555
sales.hh@minebea-intec.com
www.minebea-intec.com
Last updated 07/2017