Waterproofing: CCW-525 Liquid Applied Waterproofing Membrane

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SCIENCE. SERVICE. SOLUTIONS.

WATERPROOFING
CCW-525 Liquid Applied Waterproofing Membrane

800.527.7092 | www.carlisleccw.com
WATERPROOFING
CCW-525 Liquid Applied Waterproofing Membrane

Carlisle Coatings & Waterproofing, Incorporated (CCW) Carlisle waterproofing systems by detailing critical areas
provides a broad range of solutions to meet specific such as transitions and angle changes, while its single-
waterproofing needs. CCW offers technical services, person, one-step application allows for improved jobsite
research & development and manufacturing capabilities efficiency.
from its headquarters in Wylie, Texas and two additional
CCW-525’s moisture-cured, modified-polyurethane
manufacturing facilities in Terrell, TX and Carlisle,
properties cure to form a strong, flexible membrane
PA. The CCW network is further supported by over 50
for various below-grade applications. With an available
manufacturer’s sales representatives directed by regional
reinforced system for heavy-duty applications, CCW-
sales offices throughout the country. CCW offers a complete
525 may be layered for greater strength and protection.
line of waterproofing and moisture protection products
It provides tenacious adhesion to concrete substrates
for the architectural, general construction, industrial and
preventing lateral water migration for both vertical and
maintenance industries. Carlisle Coatings & Waterproofing,
horizontal surfaces. CCW-525’s performance is enhanced
Inc. is part of the Carlisle Construction Materials division
when combined with the appropriate CCW MiraDRAIN®
of Carlisle Companies, Inc., which is a publicly traded
drainage system. CCW MiraDRAIN protects the
company on the NYSE.
waterproofing membrane, provides a channel for proper
CCW-525 is the simple solution for waterproofing difficult water migration and eliminates hydrostatic pressure.
below-grade areas with penetrations or various angle The inherent toughness and resilience of the CCW-525
changes. This one-part, cold-applied liquid material membrane enables it to bridge structural or shrinkage
cures to form a monolithic membrane providing lasting cracks, which may develop in the substrate, providing
waterproofing protection. CCW-525 compliments other lasting waterproofing protection.

Typical Use
Drainage plays a critical role in the design and construction of below-grade
applications. Without proper drainage, groundwater seepage may cause
hydrostatic pressure, and leakage, resulting in structural damage.
Effective drainage is essential. Yet, the costly and time-consuming
installation of a conventional aggregate drainage system often compels
builders and designers to compromise on drainage. This compromise
can result in maintenance costs that far outweigh those associated with
installing an effective drainage system.

Standard, Tests, Certificates


ASTM Specification: ASTM C 836-95
Packaging, Types & Accessories
• 5-gallon pails
Features & Benefits
• CCW-525-H – Horizontal Grade (self leveling)
• Liquid-applied membrane
• CCW-525-V – Vertical Grade (roller applied)
• Single component
• Carlisle DCH Polyester Reinforcing Fabric – 40" x 324'
• Moisture cured
• CCW-201 Mastic – 1.5-Gallon Kit
• Coal-tar free
• Carlisle LiquiFiber Reinforcement - 6" x 300' and 12" x 300'
• Cures to an elastomeric, monolithic membrane
Installation • Vertical or horizontal application
Surface Preparation • Provides tenacious adhesion
New concrete shall be water cured, followed by a light hair broom, trowel • Perfect for planters
finish and in place for 14 days minimum, 28 days preferred. If curing
compounds are required, use the self dissipating type or as approved • Can be used on smaller areas and detail work
by CCW. CCW-525 adheres to surfaces that are structurally sound, dry,
and free of oil, grease, dirt, laitance, curing or release agents and other
contaminants that can harmfully affect the adhesion of the membrane.
Block wall mortar joints must be struck flush. Horizontal: Apply CCW-525-H over the cleaned, primed flange of drains,
Remove splatters, fins, ridges or other projections to provide a smooth, taking care not to fill weep holes. Using a notched squeegee, apply
level surface. Fill tie rod holes, honeycombs, rock pockets, spalls or other CCW-525-H at 22 square feet per gallon or as required to obtain a 60-mil
voids and indentations with non-shrink grout. thickness, to the entire area, including over all detail coats.
Saw-cut moving cracks greater than 1⁄16" width to ¼" wide by ¼" deep. Vertical: Using a medium nap roller, apply CCW-525-V in two coats at a
Provide a smooth and level surface by grinding or filling (as required) the rate of 44 square feet per gallon or as required to obtain 30 mils per coat
surface at cold joints where each pour is at a different plane. Clean metal for a total thickness of 60 mils.
to expose a bright finish. Reinforced System: Apply CCW-525-H at 22 square feet per gallon or as
For detail work, clean joints and saw-cut cracks per the dimensions required to obtain a 60-mil thickness to the entire area, including over all
provided above. All moving cracks over 1⁄16" wide and all expansion joints detail coats.
less than 1" wide shall be cleaned, primed, fitted with a backing rod and Use a ¼" notched squeegee or flat squeegee with guide pins to achieve
caulked with Carlisle Polyurethane Sealant as recommended by the data a uniform thickness. Immediately install Carlisle DCH white polyester
sheet. For larger joints, contact a CCW representative. reinforcing fabric. Install carefully to avoid wrinkles. In the event of wrinkles
Apply a 1", 45° angle sealant cant of CCW-201 at the juncture of all or fishmouths, cut the fabric and overlap the excess to avoid trapped
vertical and horizontal surfaces including around pipes, vents and other air. Extend the second layer of CCW-525 past the edge of the fabric to
projections. Apply bondbreaker tape (or wax) over the sealant installed in completely encapsulate the first layer. The completed system will have a
expansion joints and saw-cut cracks. When using bondbreaker tape, apply total thickness of 120 mils.
three times the width of the joint. Protection: The membrane must be protected from damage by future
Apply a 4"–6" wide stripe coat of CCW-525-V over all sealed cracks, joints operations and other trades. CCW Protection Board is recommended for
and over all hairline cracks and cold joints. Apply a stripe coat of CCW-525-V both vertical or horizontal surfaces. Install a protection course on vertical
over sealant cants and up the vertical wall to the height referred to on the walls immediately after membrane has cured (36 hrs at 75°F). Install
applicable detail drawing, (minimum 8" recommended) and onto the horizontal the protection course on horizontal application immediately following
deck 4"–6". Apply stripe coat at 45 ± 5 mils and allow to cure overnight. successful flood testing. If flood test is delayed, install a temporary
covering to protect the membrane from other trades.
Priming
Flood Test: After membrane has cured 36 to 72 hours, plug drains and
For adhesion to dry, nonporous concrete, primer is not necessary. However, provide necessary barriers to contain flood water. Flood deck with a
if pinhole and blister problems occur as a result of air and/or moisture 1" head of water and allow to stand for 24 hours. Check for leaks and
vapors emitted from the concrete and environmental conditions, it is immediately make repairs if required. Retest after any repairs have
recommended that the surface be primed. Contact CCW Technical Services been made.
for primer compatibility.
Clean Up: Before material cures, clean adjacent areas to remove stains or
Application spills and clean tools with toluene or xylene. Do not clean or wash skin
with solvents.
Prior to detail work, wipe all previously applied 525" areas with a clean
cloth containing xylene solvent and allow the prepared area to dry.
Technical Data
Property Application Type Test Method Results

Composition Horizontal, Vertical & Roller — Modified Polyurethane


Color Horizontal, Vertical & Roller — Black
Tack Free Time Horizontal, Vertical & Roller @ 75°F (24°C), 50% RH. 16 hrs
Cure Time Horizontal, Vertical & Roller @ 75°F (24°C), 50% RH. 36 hrs
Solids Content Horizontal, Vertical & Roller ASTM D 2369 82% (+/- 2)
Hardness Horizontal, Vertical & Roller ASTM D 2240 30 Shore A (min.)
Elongation Horizontal, Vertical & Roller ASTM D 412 575%
ASTM D 412 600%
Tensile Horizontal, Vertical & Roller ASTM D 412 250 psi
ASTM D 412 400 psi
Permeability 3 Horizontal, Vertical & Roller ASTM E 96 0.07384 perms
ASTM E 96 0.07176 perms
Adhesion to Primed Concrete Horizontal, Vertical & Roller ASTM D 903 14.9 lbs/in (12.9 kg/cm)
ASTM D 903 19.0 lbs/in (16.4 kg/cm)

Limited Warranty
Carlisle Coatings & Waterproofing, Incorporated (Carlisle) warrants this Carlisle specifically disclaims liability for any incidental, consequential or
product to be free of defects in workmanship and materials only at the other damages including, but not limited to, loss of profits or damages to a
time of shipment from our factory. If any Carlisle materials prove to contain structure or its contents arising under any theory of law whatsoever.
manufacturing defects that substantially affect their performance, Carlisle
The dollar value of Carlisle’s liability and buyer’s remedy under this limited
will, at its option, replace the materials or refund its purchase price.
warranty shall not exceed the purchase price of the Carlisle material
This limited warranty is the only warranty extended by Carlisle with in question.
respect to its materials. There are no other warranties including the implied
warranties of merchantability and fitness for a particular purpose.

Carlisle Coatings & Waterproofing


900 Hensley Lane | Wylie, TX 75098 | 800.527.7092 | www.carlisleccw.com

03.06.15 © 2015 Carlisle. Carlisle and MiraDRAIN are trademarks of Carlisle.