Cat Electronic Technician 2019A v1.0 Product Status Report
Cat Electronic Technician 2019A v1.0 Product Status Report
Cat Electronic Technician 2019A v1.0 Product Status Report
0
Product Status Report
10/25/2021 3:45 PM
Logged Diagnostic Codes [Diagnostic Clock = 11036 hours] - 3176C 966G (3PD07367)
Code Description Occ. First Last
562- 9 Caterpillar Monitor System : Abnormal Update 4 10896 10999
Rate
91- 8 Throttle Position Sensor : Abnormal Frequency, 1 10987 10987
Pulse Width, or Period
291- 5 Engine Cooling Fan Solenoid : Current Below 5 10891 10938
Normal
Logged Event Codes [Diagnostic Clock = 11036 hours] - 3176C 966G (3PD07367)
Code Description Occ. First Last
No Logged
Event Codes
Logged Diagnostic Codes [Diagnostic Clock = 11117 hours] - Transmission 966 (Not
Programmed)
Code Description Occ. First Last
70- 3 Parking Brake Switch : Voltage Above Normal 1 11117 11117
177- 3 Transmission Oil Temperature Sensor : Voltage 127 7797 11117
Above Normal
668- 2 Transmission Shift Lever : Erratic, Intermittent, or 72 11109 11117
Incorrect
795- 7 Secondary Steering Intermediate Relay : Not 3 10977 11018
Responding Properly
Logged Event Codes [Diagnostic Clock = 11117 hours] - Transmission 966 (Not Programmed)
Code Description Occ. First Last
No Logged
Event Codes
Logged Diagnostic Codes [Diagnostic Clock = 8099 hours] - Cat Monitor System 966G
Code Description Occ. First Last
96- 3 Fuel Level Sensor : Voltage Above Normal 5 8099 8099
248- 2 Invalid Cat Data Link data 7 8099 8099
271- 5 Action Alarm : Current Below Normal 120 7942 8099