Event Code Machine D9
Event Code Machine D9
3
01: /05/2 2659
logged to the ECM. The active events and the logged events can be viewed with the Operator
Monitor or the Cat® Electronic Technician (Cat ET) Service Tool.
Warning Levels
3
M0 7:45+ 6
1
© 2 0283 07:00
The ECM assigns one of the three warning levels to an active event code according to the severity
of the abnormal system condition. Each warning level requires a specific response from the operator.
023 7
The warning levels and required operator response are listed below.
r In
check the involved system. Perform any necessary maintenance to the system at the earliest
possible time.
Warning Level 2
c.
Warning Level 2 requires changing the operation of the machine or performing a maintenance
procedure. Failure to correct the problem behind this warning will damage the components that are
involved. The problem that caused the event requires correction, before the machine can resume
operation.
Warning Level 3
Warning Level 3 requires an immediate safe shutdown of the machine to avoid damage to the
machine or injury to personnel around the machine. The problem that caused the event must be
corrected before machine operation can resume.
WARNING OPERATION
the Action
Subsystem Alarm
1 OFF No immediate No harmful,
action is required. damaging effects
OFF OFF
The system needs result.
attention soon.
2 Flashing Change machine The system
Amber operation or components are
ON OFF perform damaged.
maintenance to the
system.
3 Flash Pulse ON and Immediately The operator is
Red. OFF. perform a safe injured or the
ON
engine shutdown. components are
damaged.
(1)
(if no action is taken by the operator).
Event codes are displayed on Cat ET or the monitor in the following format:
The "E" means that the code is an event code. The "XXXX" is a numeric identifier. The numeric
identifier is followed by a description of the code.
Active event codes are listed in ascending numerical order. The code with the lowest number is
listed first. The active event code is removed from the list when the condition is no longer present.
A logged code is cleared from memory when one of the following conditions occur:
A new code is logged and there are already ten logged codes in memory. In this case, the oldest
logged code is cleared.
Note: Always clear logged event codes after investigating and correcting the problem which
generated the code.
Troubleshooting
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 2/13
5/26/23, 8:37 AM SIS 2.0
1. Obtain the following information from the operator monitor and the machine operator:
Determine the operating conditions for the engine at the time of the event. Conditions such
as engine RPM and load may be important.
Determine if there are any systems that were installed by the dealer or by the customer that
could cause the event.
2. Some of the events below can become active during normal system operation. Verify that the
event is not due to error of the operator.
Table 2
EID
Description Possible Cause/Recommended Response
(Level)
Immediate Safe Engine Shutdown is required
Indicates that the transmission output speed has exceeded speeds
that are acceptable for internal transmission components.
During machine retarding with increased output speeds of the
engine, torque converter, and transmission, the transmission output
Transmission Over speed has exceeded 3180 RPM for 0.5 seconds.
E83 (3)
Speed
Probable Cause:
Incorrect gear for Grade
Recommendation:
Send engineering data transport file to engineering.
E155 High Torque Probable Cause:
(2) Converter Oil Excessive machine operation conditions. Event is logged when the
Temperature torque converter oil (TCO) temperature exceeds 129° C (264° F) for
10 seconds.
Recommendation:
Change machine operation to allow TCO to cool. If needed, park the
machine and set engine at high idle until TCO temp event clears.
Once activated, the level 2 event will not become inactive until the
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 3/13
5/26/23, 8:37 AM SIS 2.0
Probable Cause:
Excessive machine operation conditions. Event is logged when the
temperature of the T/C oil has reached a critical level of 135 °C
(275 °F) for 30 seconds.
Recommendation:
Allow T/C oil to cool. Park the machine and set engine at high idle
High Torque
E155 until T/C oil temp event clears.
Converter Oil
(3) Investigate the reason for the high TCO temp. Check other
Temperature
machines in similar applications to see if site conditions are the
cause.
Enable "Enhanced Autoshift" for more appropriate gear usage
during excessive machine operations.
Probable Cause:
This code could be the result of a failure of a physical or an
E192 Steering System electrical component.
(3) Malfunction
Recommendation:
Perform a visual inspection of steering linkages. Use Cat ET to
determine if any diagnostic codes related to steering are active or
logged. Correct all diagnostic codes.
Probable Cause:
The engine did not start within the programmed parameters for
E225 engine starting.
Engine Overcrank
(2)
Recommendation:
Troubleshoot for Engine Overcrank Occurrences.
E256 Steering Output Immediate Safe Shut Down of Machine is Required.
(3) Detected in Wrong
Direction Probable Cause:
Usually occurs after servicing.
Hydraulic hose connections are reversed. - Electrical connections of
the secondary solenoid are reversed. - Hydraulic steering valve is
malfunctioning
Recommendation:
Check for and clear any active CID 1469 or CID 1470 diagnostic
codes for the steering motor speed sensor input signal circuits.
Check the following components for correct wire connections: Left
hand and Right hand steering solenoids and the two steer speed
sensor signal circuits.
Check the following hydraulic components for correct connections
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 4/13
5/26/23, 8:37 AM SIS 2.0
Probable Cause:
Activated when steering cylinder movement is detected and the
Steering Output
E257 joystick is not moved.
Detected with No
(3)
Command Given
Recommendation:
Cycle the disconnect switch and the key start switch. Start the
machine and determine is this event code is reactivated. Discover
and correct diagnostic codes related to the steering system.
Immediate Safe Shut Down of Machine is Required.
Probable Cause:
No Steering No steering cylinder movement is detected when commanded.
E258
Detected with
(3)
Command Given Recommendation:
Use Cat ET to determine if any diagnostic codes related to the
steering system are active. This problem could also be related to
failure of a physical component, inspect machine for damage.
Probable Cause:
Check for and clear any active CID 0473 diagnostic codes for the
charge pressure sensor input signal circuit.
E283 Low Hydraulic Manually check system pressure. Compare to the charge pressure
(2) Charge Pressure sensor reading. If values are different by 20% or more, check sensor
circuit for abnormal resistance. If the sensor circuit checks OK,
replace the sensor.
The correct operating pressure is 3050 ± 100 kPa (442.4 ± 14.5 psi.)
Check the system pressure and charge pump pressure setting.
Check for and clear any active CID 0473 diagnostic codes for the
charge pressure sensor input signal circuit.
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 5/13
5/26/23, 8:37 AM SIS 2.0
The correct operating pressure is 3050 ± 100 kPa (442.4 ± 14.5 psi.)
Check the system pressure and charge pump pressure setting.
Probable Cause:
Low Transmission Oil Level. Code is activated when the
E644 Low Transmission transmission oil pressure is below 2400 kPa (348 psi).
(3) Oil Pressure Recommendation:
Check the transmission and associated lines for problems such as
leakage. For more information refer to Systems OperationTesting
and Adjusting, M0102843 , "D9 Track-Type Tractor", "Load Piston
- Test and Adjust"
Probable Cause:
Access ladder lowered with transmission in gear.
Recommendation:
Access Ladder If equipped, raise the ladder to avoid damage and to clear the event.
E680 Lowered with Refer to the following manuals for additional information:
(2) Transmission in •Systems OperationTesting and Adjusting, M0102843 , "D9 Track-
Gear Type Tractor" Access Ladder System or Ladder System Pressure
- Test and Adjust
•Troubleshooting Ladder System in this manual
•Operation and Maintenance Manual, M0096785 or M0082951
, "D9 Track-Type Tractor" Access Ladder Operation
E706 Park Brake Immediate Safe Shut Down of Machine is Required.
(3) Disabled Due to
System Fault Probable Cause:
This code will activate if the Park Brake solenoid state and the
pressure do not correspond. The Park Brake pressure is high
(released), and the solenoid is de-energized (Park Brake engaged).
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 6/13
5/26/23, 8:37 AM SIS 2.0
Recommendation:
Inspect the park brake fluid connections for signs of damage or
leakage.
Check the Park Brake oil for contamination.
The ECM internal clock is also known as an electronic service hour
meter.
Probable Cause:
Event is active when the system voltage is less than 23 VDC for
more than 10 seconds.
Note: The engine must be running for more than 60 seconds for the
code to activate.
E875 Low System
(3) Voltage Recommended Action:
Move the machine to a safe location and shut down the machine.
Use Cat ET to identify diagnostic codes related to high voltage. Use
the appropriate troubleshooting procedure to correct the source of
the low voltage. [Or Troubleshoot using Troubleshooting Charging
System - Test in this manual.] The machine returns to normal
operation when the voltage exceeds 23.5 VDC for more than 3
seconds.
E876 High System Probable Cause:
(2) Voltage Event is active when the system voltage exceeds 30.5 VDC for
more than 10 seconds.
Recommended Action:
Move the machine to a safe location and shut down the machine.
Use Cat ET to identify diagnostic codes related to high voltage. Use
the appropriate troubleshooting procedure to correct the source of
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 7/13
5/26/23, 8:37 AM SIS 2.0
Probable Cause:
Event is active when the system voltage exceeds 32 VDC for more
than 5 seconds.
E876 High System
(3) Voltage Recommended Action:
Move the machine to a safe location and shut down the machine.
Use Cat ET to identify diagnostic codes related to high voltage. Use
the appropriate troubleshooting procedure to correct the source of
the excess voltage. The machine returns to normal operation when
the voltage is less than 31.5 VDC for more than 3 seconds.
The Transmission Inlet Oil Temperature is Higher than 119° C
(246° F) for 10 seconds.
Probable Cause:
There is an Issue with the Transmission Inlet Temp sensor/wiring
resistance.
E877 High Transmission
Transmission oil cooler issue
(2) Oil Temperature
Power train system leakage
Recommendation:
Check transmission oil cooler functionality.
Ensure that the engine fan is clear of debris.
Check system pressures for leakage
Probable Cause:
Access ladder lowered with the park brake disengaged.
Recommendation:
Access Ladder If equipped, raise the ladder to avoid damage and to clear the event.
E1336 Lowered with Park Refer to the following manuals for additional information:
(2) Brake •Systems OperationTesting and Adjusting, M0102843 , "D9 Track-
Disengaged Type Tractor" Access Ladder System or Ladder System Pressure
- Test and Adjust
•Troubleshooting Ladder System in this manual
•Operation and Maintenance Manual, M0096785 or M0082951
, "D9 Track-Type Tractor" Access Ladder Operation
Possible Cause:
Event is active when the system voltage exceeds 32 VDC for more
than 5 seconds.
E1378 High ECM Power
Recommended Response:
(2) Input Voltage
The machine returns to normal operation when the voltage exceeds
31.5 VDC for more than 5 seconds. Refer to the Troubleshooting
Electrical Power Supply - Test section within this manual to
correct the problem associated with this event code.
E1379 Low ECM Power Possible Cause:
(2) Input Voltage Event is active when the system voltage is less than 18 VDC for
more than 3 seconds.
Recommended Response:
The machine returns to normal operation when the voltage exceeds
18.5 VDC for more than 5 seconds. Refer to the Troubleshooting
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 8/13
5/26/23, 8:37 AM SIS 2.0
Table 3
EID
Description Possible Cause/Recommended Response
(Level)
Probable Cause:
The grease level within the Auto Lube attachment is low or has a
bad sensor
E234 Low Auto Lube
(1) Grease Level
Recommended Action:
Check for leaks, kinked, or plugged lines, fuse, or pump, refill
grease level then troubleshoot sensor.
Activated and logged after four of the E234 (1) events occur. Every
time four E234 (1) low-level events occur consecutively, the count
of this fault will continue to rise.
A popup banner will occur with this level 2 fault.
Continued lube pumping is unavailable when this fault is active.
The pump will continue to check if the fault code can be cleared on
the pumps normal operation schedule (set by the user).
E234 Low Auto Lube
(2) Grease Level
Probable Cause:
The grease level within the Auto Lube attachment is low or has a
bad sensor.
Recommended Action:
Check for leaks, kinked, or plugged lines, fuse, or pump, refill
grease level then troubleshoot sensor.
E235 Low Hydraulic Oil Probable Cause:
(1) Level Low oil level, broken line, or bad sensor
Recommended Action:
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 9/13
5/26/23, 8:37 AM SIS 2.0
Check the hydraulic oil level on the liquid indicator gauge on the
side of the tank. Fill if the tank is low. If the gauge shows that the
tank is full, check the hydraulic lines for damage.
Immediate Safe Engine Shutdown is required
Probable Cause:
Low oil level, broken line, or bad sensor
E235 Low Hydraulic Oil
(3) Level
Recommended Action:
Check the hydraulic oil level on the liquid indicator gauge on the
side of the tank. Fill if the tank is low. If the gauge shows that the
tank is full, check the hydraulic lines for damage.
Probable Cause:
Low grease level, broken line, or bad sensor
E334 Low Auto Lube
(1) Pressure Recommended Action:
Check for leaks, kinked, or plugged lines, fuse, or pump, refill
grease level then troubleshoot sensor.
Possible Cause:
The hydraulic case drain filter is plugged so the oil is being
Hydraulic Case bypassed.
E454
Drain Filter
(2)
Plugged Recommended Action:
No immediate action required, however the system needs attention
soon. Clean or replace the hydraulic case drain filter.
Probable Cause:
Plugged injector, crushed line, or bad sensor.
Auto Lube Pressure Failed or stuck vent valve
E521
Not Decreasing
(1)
After Cycle Recommended Action:
Check lines, test injectors, test vent valve, and then troubleshoot
the sensor.
Probable Cause:
Plugged injector, crushed line, or bad sensor.
Auto Lube Pressure Failed or stuck vent valve
E521
Not Decreasing
(2)
After Cycle Recommended Action:
Check lines, test injectors, test vent valve, and then troubleshoot
the sensor.
The ECM internal clock is also known as an electronic service hour
meter.
Recommended Action:
Modify machine operation to reduce system load.
Check hydraulic oil level.
Check the hydraulic oil cooling system.
Check hydraulic oil quality.
Immediate Safe Shutdown Is Required
Probable Cause:
System hydraulic temperature exceeds 100° C (212° F).
E878 High Hydraulic Oil
(3) Temperature Recommended Action:
Modify machine operation to reduce system load.
Check hydraulic oil level.
Check the hydraulic oil cooling system.
Check hydraulic oil quality.
Probable Cause:
Activates when trip conditions for other codes occur and prevent
the system from operating.
E890 Auto Lube System
(2) Cannot Operate
Recommended Action:
Refer to System Operation Test and Adjust, M0124845 ,
Automatic Lubrication System for more information.
Probable Cause:
Filter is plugged.
E1257 Winch Filter
(2) Plugged Recommended Action:
No immediate action required, however the system needs attention
soon. Clean or replace the winch filter.
Possible Cause:
Event is active when the system voltage exceeds 32 VDC for more
than 5 seconds.
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%25… 11/13
5/26/23, 8:37 AM SIS 2.0
Probable Cause:
Machine or Onboard IMU is in an unacceptable position or bad
Unacceptable sensors.
E1394
Machine
(2)
Orientation Recommended Action:
Visually verify that the machine and IMU are correctly positioned.
Restart the system. Then if needed, troubleshoot sensors.
Immediate Safe Shutdown Is Required
Probable Cause:
Unacceptable Machine or Onboard IMU is in an unacceptable position or bad
E1394
Machine sensors.
(3)
Orientation
Recommended Action:
Visually verify that the machine and IMU are correctly positioned.
Restart the system. Then if needed, troubleshoot sensors.
Probable Cause:
Access ladder lowered with blade movement detected.
Recommendation:
If equipped, raise the ladder to avoid damage and to clear the
Access Ladder
event.
E1397 Lowered with Blade
Refer to the following manuals for additional information:
(2) Movement
•Systems OperationTesting and Adjusting, M0102843 , "D9
Detected
Track-Type Tractor" Access Ladder System or Ladder System
Pressure - Test and Adjust
•Troubleshooting Ladder System in this manual
•Operation and Maintenance Manual, M0096785 or M0082951
, "D9 Track-Type Tractor" Access Ladder Operation
Immediate Safe Shutdown Is Required
PSP-00022659
2023/05/26
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Event%2520Codes%2520(M0102837-00)%2522%252C%2… 12/13
5/26/23, 8:37 AM 3
01: /05/2 2659 SIS 2.0
01:37:33+07:00