N67 TE2F

170 kW (1500 rpm) - 210 kW (1800rpm)

Engine N67 TE2F


1/ GENERAL 1500 rpm 1800 rpm

Engine Model NEF67 TE2F


Basic engine 504388397XY
Engine Type F4HE0685F*J/F4HE0685B*J
Number of cylinders 6
Firing order (N° 1 nearest to fan) 1-5-3-6-2-4
Cylinder arrangement in line
Valves per cylinder 4
Cycle diesel 4 stroke
Injection system direct common rail
Electronic engine control unit BOSCH EDC7 UC31
Induction System turbocharged aftercooled air/air
Bore mm 104
Stroke mm 132
Total displacement lit 6,7
Mean piston speed m/s 6,6 7,9
Compression ratio 17,5 : 1
Flywheel rotation anti clockwise viewed on flywheel
Housing flywheel SAE 3
Flywheel 11''1/2
Moment of inertia
without flywheel kgm2 0,31
flywheel only kgm2 0,71
Degree of irregulariry at PRP 0,05 0,03
BMEP gross
Prime Power bar/kPa 18,5 / 1851 19/1900
Stand-by Power bar/kPa 20,3 / 2030 20,9/2089
Dry weight (including cooling package) kg ~ 630
Energy to coolant kcal/kWh 300 290
Energy to charge cooler kcal/kWh 150 171
Energy to radiation kcal/kWh 300 303
Dimensions L x W x H mm 1713 x 796 x 1230

2/ PERFORMANCES 1500 rpm 1800 rpm

Continuous Power (gross) kWm 125 155


Prime Power (gross) kWm 155 191
Stand-By Power (gross) kWm 170 210
Fan consumption kWm 4,8 8,3
Continuous Power (net) kWm 120 147
Prime Power (net) kWm 150 183
Stand-By Power (net) kWm 165 202
Performance condition
temperature °C ≤ 40
altitude a.s.l m ≤ 1000
Derating
temperature > T 40°C %/5°C 2%
altitude >1000 <3000 m %/500m 3%
altitude >3000 m %/500m 6%

1/3
N67 TE2F
170 kW (1500 rpm) - 210 kW (1800rpm)

Engine N67 TE2F


3/ COOLING SYSTEM 1500 rpm 1800 rpm

Type liquid
Recommanded coolant see FPT specific document
Coolant capacity
engine only liter 10,5
radiator and hoses liter 15
Coolant pump flow l/min 141 169
Engine coolant outlet max temp. °C 90
Engine coolant inlet temp. °C 85
Thermostat: start to open °C 80
Thermostat: fully open °C 96
Pressure cap setting kPa (bar) 100 (1,0)
Shutdown switch setting °C 103
Maximum additional restriction Pa 196
Air To Boil Prime Power °C 58 58
Fan
diameter mm 685 685
number of blades 12 12
drive ratio 1,41:1 1,4:1
speed rpm 2115 2538
air flow m3/s 3,8 4,8
power consumption kWm 4,8 8,3

4/ LUBRICATION SYSTEM 1500 rpm 1800 rpm

Oil sump capacity


max liter 15
min liter 8
Oil system capacity including filter liter 17
Oil pressure at rated speed kPa 300-500
Oil temperature
normal °C ---
max °C 120
Engine angularity
longitudinal degrees 35°
transverse degrees 35°
Servicing interval hours 600
Oil specification see FPT specific document
Oil consumption %fuel < 0,1

5/ INTAKE SYSTEM 1500 rpm 1800 rpm

Air consumption at 100 % of load m3/h (Kg/h) 652 (782,5) 832 (998)
Air intake restriction, clean filter kPa (mbar) 2 (20) 2 (20)
Air intake restriction, dirty filter kPa (mbar) 4,5 (45) 4,5 (45)
Air filter type dry dry

2/3
N67 TE2F
170 kW (1500 rpm) - 210 kW (1800rpm)

Engine N67 TE2F


6/ EXHAUST SYSTEM 1500 rpm 1800 rpm

Gas flow at stand-by Power kg/h 819,5 1040


Max temperature at PRP (25°C) °C 610 565
Max allowable back pressure kPa (mbar) 8 (80) 8 (80)
Energy to exhaust kcal/kWh 614 634

7/ FUEL SYSTEM 1500 rpm 1800 rpm

Fuel consumption at
Stand-By gr/kWh [kg/h] (l/h) 217 [36,9] (43,4) 207 [44,1] (51,9)
Full load gr/kWh [kg/h] (l/h) 215 [33,3] (40) 214 [41] (48,2)
80% gr/kWh [kg/h] (l/h) 220 [27,5] (32,4) 222 [39] (46)
50% gr/kWh [kg/h] (l/h) 239 [20,4] (24,1) 227 [25] (29,4)
Fuel specifications see FPT specific document
Feed pump max suction head m ---

8/ ELECTRIC SYSTEM 1500 rpm 1800 rpm

Voltage (negative to ground) V 12


Starter motor
make Bosch
power kW 3
pull current Amp 60
hold current Amp 12
break away current +20°C Amp 1900
cranking current +20°C Amp 0
Number of teeth on starter motor 10
Number of teeth on flywheel 125
Starting batteries
recommended capacity Ah 1x 180
discharge current Amp 800
(EN 50342)
Alternator
voltage V 14
charge Amp 90

9/ COLD STARTING 1500 rpm 1800 rpm

Without air preheating °C -10


With air preheating °C -25

10/ EMISSION GASEOUS AND PARTICLES 1500 rpm 1800 rpm

Nox Oxides of nitrogen gr/kWh 3,59 3,31


HC Hydrocarbons gr/kWh 0,15 0,19
Nox+HC gr/kWh 3,74 3,5
CO Carbon monoxide gr/kWh 0,79 0,71
PT Particles gr/kWh 0,09 0,124