N67 TE2F: 1/ General
N67 TE2F: 1/ General
N67 TE2F: 1/ General
1/3
N67 TE2F
170 kW (1500 rpm) - 210 kW (1800rpm)
Type liquid
Recommanded coolant see FPT specific document
Coolant capacity
engine only liter 10,5
radiator and hoses liter 15
Coolant pump flow l/min 141 169
Engine coolant outlet max temp. °C 90
Engine coolant inlet temp. °C 85
Thermostat: start to open °C 80
Thermostat: fully open °C 96
Pressure cap setting kPa (bar) 100 (1,0)
Shutdown switch setting °C 103
Maximum additional restriction Pa 196
Air To Boil Prime Power °C 58 58
Fan
diameter mm 685 685
number of blades 12 12
drive ratio 1,41:1 1,4:1
speed rpm 2115 2538
air flow m3/s 3,8 4,8
power consumption kWm 4,8 8,3
Air consumption at 100 % of load m3/h (Kg/h) 652 (782,5) 832 (998)
Air intake restriction, clean filter kPa (mbar) 2 (20) 2 (20)
Air intake restriction, dirty filter kPa (mbar) 4,5 (45) 4,5 (45)
Air filter type dry dry
2/3
N67 TE2F
170 kW (1500 rpm) - 210 kW (1800rpm)
Fuel consumption at
Stand-By gr/kWh [kg/h] (l/h) 217 [36,9] (43,4) 207 [44,1] (51,9)
Full load gr/kWh [kg/h] (l/h) 215 [33,3] (40) 214 [41] (48,2)
80% gr/kWh [kg/h] (l/h) 220 [27,5] (32,4) 222 [39] (46)
50% gr/kWh [kg/h] (l/h) 239 [20,4] (24,1) 227 [25] (29,4)
Fuel specifications see FPT specific document
Feed pump max suction head m ---
3/3