ARTESYN

LPT40 Series
40 Watts

Advanced Energy's Artesyn LPT40 series of open-frame Data Sheet


AC-DC power supplies comprises seven triple output
models, covering a variety of standard voltages from -15 V
Total Power:
to 24 Vdc. Each model accepts a universal input of 85—264
44 - 55 Watts
Vac or 120—300 Vdc. These compact switch-mode power
supplies feature main output overvoltage protection and Input Voltage:

remote sense, with short-circuit protection on all outputs. 85 - 264 Vac


Depending on the model, they provide up to 40 watts of 120 - 300 Vdc

output power with free air convection cooling and up to 55 # of Outputs:


watts with 30 CFM of forced air. Less than 1U high, LPT40 Triple
series power supplies are suitable for a variety of uses
including test and measurement, single-board computers,
telecommunications and networking.

Special Features Safety

 Universal input  UL UL60950


 3” x 5” footprint E132002
 Less than 1U high  cUL 60950

 Remote sense on main output


Level 3 LR53982C
 NEMKO EN 60950/EMKO-TUE
 Built-in EMI filter
P95100411 (74-sec) 203
 Low output ripple
 CB Certificate and report
 Adjustable main output
1118, 1122, 1123, 1124
 Overvoltage protection
 CE Mark (LVD)
 Overload protection
 110 KHz switching frequency
 LPX40 enclosure kit available
 RoHS compliant

©2020 Advanced Energy Industries, Inc.


LPT40

ELECTRICAL SPECIFICATIONS

Input
Input range 85 - 264 Vac; 120 - 300 Vdc
Frequency 47 - 440 Hz
Inrush current < 18 A peak @ 115 Vac;
< 36 A peak @ 230 Vac, cold start @ 25 °C
Input current 1 A max. (RMS) @ 115 Vac
Efficiency 70% typical at full load (60% for LPT41)
EMI FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
Safety ground leakage current < 0.5 mA @ 50/60 Hz, 264 Vac input

Output
Maximum power 40 W for convection (LPT41, 25 W);
55 W with 30CFM forced air (LPT41, 41 W)
Cross regulation ±2% on output 1; ±5% on outputs 2, 3
Adjustment range -5, +10% minimum
Hold-up time 20 ms @ 40 W load, 115 Vac nominal line
Overload protection Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating
Overvoltage protection 5.7 to 6.7 Vdc on the main outputLPT41: 3.6 to 4.6 Vdc
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse
connection protected.

Environmental Specifications

Operating temperature 0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 °C to 70 °C, -20 °C start up.
Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity Operating; non-condensing 5% to 95%
Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz,
operational
Storage temperature -40 °C to 85 °C
Temperature coefficient ±.04% per °C
MTBF demonstrated > 550,000 hours at full load and 25 °C ambient conditions

2 advancedenergy.com
LPT40

Ordering Information

Maximum Load Maximum Load


Model Output Minimum Ripple
with Convection with 30CFM Peak Load Regulation2
1

Number Voltage Load P/P(PARD)


3

Cooling Forced Air


+3.3 V 0.5 A 4A 7A 7A ±2% 50 mV
LPT41 +5 V 0A 1.5 A 2.0 A 2.5 A ±2% 50 mV
+12 V 0A 0.5 A 0.7 A 0.7 A ±5% 120 mV
+5 V 0.4 A 4A 5A 7A ±2% 50 mV
LPT42 +12 V 0.2 A 2A 2.5 A 4A ±5% 120 mV
-12 V 0A 0.5 A 0.7 A 1A ±5% 120 mV
+5 V 0.5 A 6A 8A 9A ±2% 50 mV
LPT43 +12 V 0A 0.5 A 0.7 A 1A ±5% 120 mV
-12 V 0A 0.5 A 0.7 A 1A ±5% 120 mV
+5 V 0.4 A 4A 5A 7A ±2% 50 mV
LPT44 +12 V 0.2 A 2A 2.5 A 4A ±5% 120 mV
-5 V 0A 0.5 A 0.7 A 1A ±5% 50 mV
+5 V 0.4 A 4A 5A 7A ±2% 50 mV
LPT45 +15 V 0.2 A 2A 2.5 A 3A ±5% 150 mV
-15 V 0A 0.5 A 0.7 A 1A ±5% 150 mV
+5 V 0.4 A 4A 5A 6A ±2% 50 mV
LPT46 +24 V 0.1 A 1.0 A 1.5 A 2A ±7% 240 mV
+12 V 0A 0.5 A 0.7 A 1A ±5% 120 mV
+5 V 0.4 A 4A 5A 6A ±2% 50 mV
LPT47 +24 V 0.2 A 1.0 A 1.5 A 2A ±7% 240 mV
-12 V 0A 0.5 A 0.7 A 1A ±5% 120 mV
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
5.  T his product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC
compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not
intended for sale to End Users.

Power Derating Curve


55W

30 CFM Forced Air Cooling


40W

30W
Output 27.5W
Natural
Power
Convection
(Watts) 20W
20W Cooling

10W

0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature-°C

advancedenergy.com 3
LPT40

Mechanical Drawing

5.00"
(127)
0.22" 4.55"
(5.6) (115.6)

M1 GND Remote Sense


M2
SK201 Connector
_+
Voltage
3.00" Adj. Pot
(76.2) SK 2
1
2
2.55" 3
(64.8) 4
SK 1 5
3 N 6
1 L

0.15" (4)
DIA (4 places)

1.14"
(29)

0.197"
(5)

4 advancedenergy.com
LPT40

Pin Assignments

Connector LPT41 LPT42 LPT43 LPT44 LPT45 LPT46 LPT47

SK1-1 Line Line Line Line Line Line Line

SK1-3 Neutral Neutral Neutral Neutral Neutral Neutral Neutral

SK2-1 5V +12V +12V +12V +15V +24V +24V

SK2-2 3.3V +5V +5V +5V +5V +5V +5V

SK2-3 3.3V +5V +5V +5V +5V +5V +5V

SK2-4 Common Common Common Common Common Common Common

SK2-5 Common Common Common Common Common Common Common

SK2-6 12V -12V -12V -5V -15V +12V -12V

SK201-1 +Sense +Sense +Sense +Sense +Sense +Sense +Sense

SK201-2 -Sense -Sense -Sense -Sense -Sense -Sense -Sense

Mating Connectors

AC Input Molex 09-50-8031 (USA)


09-93-0300 (UK)
PINS: 08-52-0113
DC Outputs Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Remote Sense Molex 22-01-2025
PINS: 08-52-0123
Artesyn Embedded Power Connector Kit #70-841-006, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”¬¬ (±0.5 mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC input, 25 °C unless otherwise stated.
6. Warranty: 2 year
7. Weight: 0.5 lbs/0.23 kg

advancedenergy.com 5
ABOUT ADVANCED ENERGY
Advanced Energy (AE) has devoted more than three
decades to perfecting power for its global customers. AE
designs and manufactures highly engineered, precision
power conversion, measurement and control solutions for
mission-critical applications and processes.

Our products enable customer innovation in complex


applications for a wide range of industries including
semiconductor equipment, industrial, manufacturing,
telecommunications, data center computing, and medical.
With deep applications know-how and responsive service
and support across the globe, we build collaborative
partnerships to meet rapid technological developments,
propel growth for our customers, and innovate the future
of power.

For international contact information,


visit advancedenergy.com.
Specifications are subject to change without notice. Not responsible
powersales@aei.com (Sales Support) for errors or omissions. ©2020 Advanced Energy Industries, Inc. All rights
productsupport.ep@aei.com (Technical Support) reserved. Advanced Energy®, AE® and Artesyn™ are U.S. trademarks
+1 888 412 7832 of Advanced Energy Industries, Inc.

ENG-LPT40-235-01 12.30