4. DXA technology
4-1. What is DXA (Dual Energy X-ray Absorptiometry)?
4-2. DXA technologies
4-3. Pencil beam
4-4. Pencil beam’s advantage
4-5. Fan beam
4-6. Fan beam’s advantage
4-7. Pencil beam vs. Fan beam
4-8. DEXXUM T
4-9. DEXXUM T specification
4-10. DEXXUM T feature
4-11. DEXXUM vs. PRODIGY clinical evaluation

www.osteosys.com
4-1. What is DXA (Dual Energy X-ray Absorptiometry)?

DXA relies on the differential absorption of two distinct photon energies - a


high and low energy photon.
The high and low energy photons will be largely unaltered by soft tissue, but
the lower energy photon will be significantly attenuated by bone compared to
the high energy photon. This difference in attenuation can be used, with the
mass attenuation coefficient for each energy and tissue type (bone or soft
tissue) to determine the mass per unit area (because each data point is a fixed
size dependent on the detector size) in the path of the beam by solving
simultaneous equations for each tissue type point by point. Effectively, the soft
tissue component becomes the reference for determining the bone
component.

www.osteosys.com
4-1. What is DXA?

DXA: dual energy  high energy and low energy

Energy division:
1. Kedge filter (OsteoSys, GE lunar)
2. Energy Switching (Hologic)

www.osteosys.com
4-1. What is DXA?

www.osteosys.com
4-2. DXA technologies

Pencil beam Fan beam Cone beam


Scan Time Low Middle High
Accuracy High High Middle, Low
Image resolution Low Low High
Radiation Dose Low Middle High
Price Low High High

www.osteosys.com
4-3. Pencil beam
Single detector and pencil line of beam
Scan in X and Y directions

Detector

BED

Generator

www.osteosys.com
4-4. Pencil beam’s advantage

- Very low radiation dose

- Gold-standard for BMD measurement

- More than 30 years of technology existence

- Cost effective

www.osteosys.com
4-5. Fan beam
Multi detectors and linear beam

www.osteosys.com
4-6. Fan beam’s advantage

- Fast scan time

- Image resolution

- Availability of options (s/w functions)

www.osteosys.com
4-7. Pencil beam vs. Fan beam

Pencil beam Fan beam


Single detector (Cost effective) Multi detectors (Expensive)
Low radiation dose High radiation dose
Gold-standard for BMD measurement Image resolution
30 years of technology existence New technology
Cost effective Availability of options
(s/w functions costs)

Scan time: (AP spine: 85 sec.) Scan time: (AP spine: 30 sec.)

www.osteosys.com
4-8. DEXXUM T

Pencil beam
Single detector (Cost effective)
Low radiation dose
Gold-standard for BMD measurement
30 years of technology existence
Cost effective
Scan time: (AP spine: 85 sec.)

www.osteosys.com
4-8. DEXXUM T

DEXXUM T
The innovation of Axial bone densitometry

www.osteosys.com
4-9. DEXXUM T specification

DEXXUM T
The innovation of Axial bone densitometry

Scan method: Pencil beam

Scan site: AP spine, femur, dual femur, forearm

Mesured parameters: BMD, BMC, area, tissue thickness

Precision/ Accuracy: 1%

Calibration system: Automatic calibration, daily QC phantom

Patient positioning: Laser aid positioning (Plus shape type)

Image transmission: DICOM support

Dimension: 2000*800*1221mm

Weight: 130.5kg

www.osteosys.com
4-10. DEXXUM T feature

-Compact design
-Fast scan time in pencil beam: Spine 85 sec. Femur: 65 sec.
-Standard options: dual femur, forearm, DICOM system support, work-list,
-One printed report, Re-scan function, etc.
-Non-stop scan (Ap spine & dual femur)
-Wide scan area
-Easy to use
-Automatic ROI (Region Of Interest)
-Comprehensive report with full information
-Automatic data back up system
-Easy installation

www.osteosys.com