Dr.

Fixit Prebond
H D P E P R E A P P L I E D F U L LY B O N D E D M E M B R A N E
WATERPROOFING

Description
Dr. Fixit Prebond membrane is a preformed HDPE fully bonded membrane that bonds to the wet concrete cast on
the membrane. After the membrane bonds with the concrete it forms an integral seal which prevents lateral water
migration and makes it unaffected by any substrate settlement below the slabs. Reinforcement can be directly laid
on top of the membrane and it does not require screed protection.
132 Dr. Fixit Prebond

Dr. Fixit Prebond is a unique HDPE membrane comprising of a virgin HDPE layer and a pressure sensitive adhesive
layer which is covered by a weather proof protective layer. The adhesive layer is activated when the concrete is
poured on the membrane and it enables the membrane bond to underside of the concrete which prevents the
ingress of water into the structure as well as prevents tracking of water between the membrane and the structure
and provide a positive side protection against ingress of sub soil water. Dr. Fixit Prebond can be used for horizontal
as well as vertical blind side application.

Typical Application
}}Basement.
}}Subway and UG metro project.
}}Cut and cover tunnels.
}}Caverns.
}}Other underground civil structures.

Features
}}Good bonding with concrete applied on membrane, to protect concrete effectively.
}}Low flatness requirement to substrate; reliable overlapping; fast and easy application.
}}Sound anti-puncture performance.
}}Adaptable to varying surface profile.
}}Resistant to high hydrostatic ground water-pressure.
}}Resistant to acid, alkali, chlorides and sulphate attack.
}}Eco-friendly material.

Packaging
2.0 m x 20 m/2.4 m x 20 m/3 m x 20 m @ the thickness of 1.2 mm/1.5 mm/2 mm

Method of Application
Dr. Fixit Prebond membranes are supplied in rolls of 2.0 m or 2.4 m wide, with a selvedge of 75 mm on one side
to provide self-adhered laps for continuity between rolls. The rolls of Prebond membrane and Prebond Tape are
inter-wound with a disposable plastic release liner which must be removed before placing reinforcement and
concrete.

1 . S U R FAC E P R E PA R AT I O N
All Surfaces – It is essential to create a sound and solid substrate to eliminate movement during the concrete pour.
Substrates must be regular and smooth with no gaps or voids greater than 12 mm. Grout around all penetrations
such as utility conduits, etc. for stability.
Horizontal Blinding – Monolithic concrete blinding or mud slab is preferred. The blinding must be free of loose
aggregate and sharp protrusions. An angular profiled blinding is recommended rather than a sloping or rounded
substrate. The surface does not need to be dry, but standing water must be removed.
Vertical confined surface – Use concrete, plywood, masonry or other approved facing to provide to level and even
support to the membrane. Board systems such as timber lagging must be close butted to provide support and not
more than 12 mm out of alignment.
Prebond 14/05/18
136
WATERPROOFING
2 M E M B R A N E I N S TA L L AT I O N
}}Prebond can be applied ambient at temperatures of –4ºC or above. During cold or damp conditions, the
selvedge and tape adhesive can be gently warmed using a hot air gun or similar to remove moisture or
condensation and improve initial adhesion.
3 H O R I ZO N TA L S U B S T R AT E S

132 Dr. Fixit Prebond


}}Place the membrane HDPE film side to the substrate with adhesive/coated side facing up towards the concrete
pour. End laps should be staggered to avoid a buildup of layers. Leave plastic release liner in position until
overlap procedure is completed. Accurately position succeeding sheets to overlap the previous sheet 75
mm along the marked selvedge. Ensure the underside of the succeeding sheet is clean, dry and free from
contamination before attempting to overlap. Peel back the plastic release liner from between the overlaps as
the two layers are bonded together. Ensure a continuous bond is achieved without creases and roll firmly with a
heavy roller.
4 V E R T I C A L S U B S T R AT E S
}}Mechanically fasten the membrane vertically using fixings (i.e. fasteners) appropriate to the substrate with the
adhesive/coated side facing towards the concrete pour. The membrane may be installed in any convenient
length. Secure the top of the membrane using a batten such as a termination bar or fixing 50 mm below the
top edge. Fixings can be made through the selvedge so that the membrane lays flat and allows firmly rolled
overlaps. Any additional fixings must be covered with a patch of Prebond Tape. Ensure the underside of the
succeeding sheet is clean, dry and free from contamination before attempting to overlap. Roll firmly to ensure a
watertight seal. Roll Ends and Cut Edges – Overlap all roll ends and cut edges by a minimum 75 mm and ensure
the area is clean and free from contamination, wiping with a damp cloth if necessary. Allow to dry and apply
Prebond Tape centered over the lap and roll firmly.
5 CO R N E R S
}}Internal and external corners should be formed as shown in the diagrams returning the membrane a minimum
of 100mm and sealing with Prebond Tape. Ensure that the apex of the corner is covered and sealed with tape
and roll firmly.

Technical Features
PROPERTIES TYPICAL VALUE TEST METHOD
Colour White –
Roll Size 2.0 m, 2.4, 3.0 m x 20 m –
2.4 mtr x 20 mtr.
Thickness Composite > 1.20mm ASTM D 3767
Tensile Strength of HDPE Without 25 Mpa ASTM D 412 Modified
Adhesive (Film)
Elongation > 500 ASTM D 412 Modified
Low Temperature Flexibility – 250C Pass ASTM D 1970
Resistance to Hydrostatic Head > 60 M ASTM D 5385 Modified
Crack Cycling Pass ASTM D 836/ASTM C 1305 Modified
Peel Adhesion to Concrete 880 N/m ASTM D 903 Modified
*Puncture Resistance 1000 N (± 5 to 10%) ASTM E 154
Heat Ageing Percent retention of tension % ≥ 92 Tensile Strength ≥ 90%
Percent retention of elongation % ≥ 85 Elongation ≥ 80%
Alkali Resistance Percent retention of tension % ≥ 95 Tensile Strength ≥ 90%
Percent retention of elongation % ≥ 85 Elongation ≥ 80%
**Dimensional Stability % 0.5 ASTM D 1204
UV Exposure 45 days pass
137
WATERPROOFING

*/** Shriram Laboratory test report

Note: Typical test values for sample tested.

Shelf Life
132 Dr. Fixit Prebond

The shelf life is 36 months if stored as per the recommendations. In a covered and secured storage space.

Other Products Categories available


Dr. Fixit brings you the widest range of Construction Chemicals

Pidilite Industries Limited DISCLAIMER The product information & application details given by the company
Construction Chemicals Division & its agents has been provided in good faith & meant to serve only as a general
Ramkrishna Mandir Road, Post Box No. 17411 guideline during usage. Users are advised to carry out tests & take trials to ensure on
the suitability of products meeting their requirement prior to full scale usage of our
Andheri (E) Mumbai 400059 INDIA
products. Since the correct identification of the problems, quality of other materials
Tel +91-22-2835 7000 • Fax +91-22-2835 7008
used and the on-site workmanship are factors beyond our control, there are no
www.drfixit.co.in • info@drfixit.co.in expressed or implied guarantee / warranty as to the results obtained. The company
Dr. Fixit Advice Centre (Toll Free No.) 1800 209 5504 does not assume any liability or consequential damage for unsatisfactory results,
138

arising from the use of our products.