Small Engine Control Module: Applications
Small Engine Control Module: Applications
Small Engine Control Module: Applications
The SECM112 is part of the MotoHawk® Control Solutions family of products. These VR or digital cam position
products enable rapid development of control systems. The combination of off-the-shelf sensor
hardware and MotoHawk software allows developers to focus on the operational specifics Up to 33 analog inputs
of the application without worrying about the design details of the hardware. The result is
Up to 4 switching oxygen
that the same hardware used in development and prototyping efforts can be used for
sensors
ongoing production.
This unit provides 112 connector pins with inputs, outputs, and communications Up to 2 wide-range oxygen
interfaces that support a wide variety of applications. sensors
Each controller is available in ‘F’ (Flash) or ‘C’ (Calibratable) versions. Flash modules are 2 knock sensors
typically used for production purposes. Calibratable modules are typically for Up to 6 speed inputs
prototyping/development only; they can be calibrated in real time using MotoTune ®,
Up to 3 switch inputs
ToolKit, or other third-party calibration tools.
Outputs:
Physical Dimensions Up to 8 injector drivers
(6 peak/hold capable)
Approximate dimensions: 281 mm x 226 mm x 37 mm (including feet) Up to 8 ignition coil drivers or
spark timer outputs
Environmental Capabilities 1 tachometer driver
The following is a summary list of the environmental limits used for design validation. Up to 19 low-side drivers
Operating Voltage 8–32 Vdc (1 w/current sense)
Operating Temperature –40 to +105 °C / –40 to +221 °F 1 main power relay driver
Storage Temperature –40 to +105 °C / –40 to +221 °F
Mechanical Vibration RV3 (22.1 Grms) 3 H-bridge drivers w/current
Mechanical Shock 50 g, 11 ms, half-sine wave, 4 shocks in each direction sense
(24 total shocks) 3 sensor supplies
EMI/RFI Specification CISPR 25 (Radiated & Conducted Emissions) (2x 5 V, 1x 12 V)
ISO 7637-2 (Conducted Transient Testing)
ISO 10605 (ESD) Communications:
ISO 11452-4 (Conducted Immunity) 3 CAN 2.0b buses
ISO 11452-2 (Radiated Immunity)
Not all population options are
ISO 7637-3 (Transient Immunity)
available in one single hardware
To assure that the SECM112 will perform as required, Woodward needs to review and
approve the actual production environmental conditions to which it will be exposed.
Released
Woodward 36364 p.2