Procal 2000 IR Emissions Analyser
Procal 2000 IR Emissions Analyser
Procal 2000 IR Emissions Analyser
The Control Unit can support multiple analysers from the Procal range
190.5 85
4 x M16 Studs equispaced
(7.5”) (3.35”) on 152.4 (6”) PCD 135
(5.3”)
180
125 Mounting Flange 12.7 (7.1”)
(4.92”) (0.5”)
Spectral range: Specific application dependent wavelengths (up to 8) are selected between 2-12μm
Infra-red source: Enclosed nichrome filament.
Infra-red detector: Solid state pyroelectric element.
Sample path length: 1 metre
Sample temperature: Up to 350°C (660°F) (higher temperatures on application)
Cross-sensitivity: Minimal due to the wavelength selection and advanced algorithms in the processor software.
Accuracy: Typically ±2% of full scale concentration but dependent on application.
Response time: Application dependent but typically 120 seconds to T90.
Enclosure: Aluminium alloy casting with high protection finish, protected to IP65 (NEMA 4X)
Operating Environment: Operating temperature range -20°C to 55°C (-4°F to 130°F).
Optional Analyser Cooler/Heater for greater temperature range.
Materials-contact with gas: Calcium Fluoride, Glass, 316 Stainless Steel, Graphite.
Services required: Power for analyser 115V/230V 100W
Power for in situ heater (optional) 115V/230V 1kW
Instrument air for the analyser void purge, auto zero and sample cell protection, controlled by the
analyser, 2 barG; flow rate 0.5 litre/min constant and 6 litre/min intermittent during Auto-zero
(typically 8 minutes every 12 hours).
Interconnection cable: 2 twisted-pair cores with individual screen typically allows up to 1200m separation between Analyser
and Procal 1000 Analyser Control Unit.
Weight: 21 kg (46.3lb).
Physical Dimensions: Analyser 1360mm (53.5”) x 380mm (15”) x 315mm (12.4”)
Optional Components
Optional accessories are available to extend the analyser’s capability in cases of extreme process or ambient variations. Typical
examples would be a probe heater to ensure the in situ gas cell operates above process gas dew point, a gas flow bypass for
high thermal stress applications and a head cooler for operation in high ambient temperature conditions. Further details of these
and many other accessories are available at www.procal.com or on the accessories data sheet.
Approvals
Continuous Emissions Monitoring The Procal 2000 system is designed to meet the requirements of both customers and
CEM - US EPA 40 CFR part 60 & 75 environmental authorities worldwide. The system enables rapid upgrades with regard
AMS - Europe QAL 3 of EN 14181 to measuring range, presentation and reporting format, thus ensuring compliance
with reporting criteria such as US EPA 40 CFR part 60 & 75 legislation. The system
calculates errors due to drift in Zero & Span Calibration before correction as required
for QAL 3 of EN 14181.