One Powerful Vision

premier diagnostic ultrasound


Product Specifications

Network and Connectivity Hardware Features


• Six USB 2.0 ports for memory sticks and peripherals • Footswitch control (scan start, scan stop, scan save, etc.)
• Fully network and printer-ready (gigabit Ethernet) • Removable one-terabyte hard drive
• Purpose-built Windows embedded operating system • Wide screen, 1920 x 1200 high-resolution monitor
• Multilingual user interface

Data Management Electrical Requirements
• DICOM Connectivity: Power supply 100-240 VAC auto-ranging
• Verification of multiple concurrent DICOM connections to
other Application Entities (AEs) Frequency 50/60 Hz
• Query / retrieval of modality work list (patient data from Input power 220 VA
Electronic Medical Records - EMR)
• Storage of DICOM objects to EMR / Picture Archiving and System Size 15.5 x 17 x 6.5 inches (39 x 43 x 16.5 cm)
Communication Systems (PACS) Weight 26 lbs. (12kg)
• Data archiving and image / movie export capability
• Customized report capability

B-Scan Modes A-Scan Modes


Customized to best • Four sets of electronic distance measurement calipers with • IOL power calculations and analysis:
variable velocity
meet your needs. • Two sets of electronic angle measurement calipers (variable
- Holladay-I
- SRK-T
velocity) - Haigis (optional)
• Movie sequence - real-time viewing and editing capability - Hoffer-Q
With customized configuration of
10 MHz Posterior Segment • Movie sequence adjustable up to 5 seconds
A-Scan and B-Scan modes, Eye Cubed™ • 50 frames-per-second image acquisition rate
• 25 frames-per-second image acquisition rate
• 10-second movie loop capability Axial Length Biometry A-Scan
covers all of your diagnostic ultrasound • Sealed probe • Immersion or contact method
needs for both the posterior and anterior • Adjustable transmit gain (minimum to 0 dB) • Solid focused probe with internal fixation light
• Adjustable receive gain (27-90 dB) • Probe frequency: 10 MHz
segments. Featuring superior image • Adjustable dynamic range (Log, S1, S2, S3) • Image depth: 40 mm
• Axial resolution: 50 microns • Points on x-axis: 2048
clarity and flexible measurements, • Lateral resolution: 100 microns • 8 bit resolution
• Scanning angle: 52 degrees
Eye Cubed™ can be used for thorough • Measurement accuracy: 50 microns inherent, 100 microns clinical
• Image depth (displayed image): 48 mm
• Automatic or manual scan acquisition
• Focal depth: 25 mm
pre-operative and post-operative • Built-in pattern recognition with automatic scleral echo detection
• Image width at focal zone: 19-36 mm
• Statistics: average and standard deviation
assessment of ocular anatomy. • Focal range: 15-35 mm
40 MHz UBM Wide-Field Anterior Segment Standardized Diagnostic A-Scan
• 13 frames-per-second image acquisition rate • Two caliper measurements displayed in mm with variable velocities
• 20-second movie loop capability • Tissue sensitivity value stored in memory with reset function
• Probe frequency: 8 MHz parallel beam
• Adjustable transmit gain (minimum to 0 dB)
• Measurement accuracy: 50 microns inherent, 100 microns clinical
• Adjustable receive gain (27-90 dB)
• Adjustable dynamic range (Log, S1, S2, S3)
• Axial resolution: 23 microns
• Lateral resolution: 33 microns
• Scanning angle: 30 degrees
• Image depth (displayed image): 11.9 mm
• Focal depth: 12.5 mm
Specifications are subject to change without notice.
• Image width at focal zone: 15-18 mm
© 2013, Ellex Medical Pty Ltd. Ellex, Eye Cubed, Smart Talk and Sensitive Scan are trademarks
• Focal range: 10.5-14.5 mm of Ellex Medical Pty Ltd. E&OE. PB0012H
Considered to be the gold standard in ophthalmic diagnostic ultrasound,
®
Eye Cubed™ features advanced movie mode using the fastest sampling
Headquarters
82 Gilbert Street
USA
7138 Shady Oak Road
Australia
82 Gilbert Street
rate available, real-time image processing and a range of self-calibrating
Adelaide, SA, 5000 AUSTRALIA Minneapolis, MN, 55344 USA Adelaide, SA, 5000 AUSTRALIA 0805
+61 8 8104 5200 800 824 7444 +61 8 8104 5264
Smart Talk™ probes to deliver unparalleled image sensitivity and quality.
Japan Germany France
4-3-7 Miyahara 4F, Yodogawa-ku Edisonstraße 20 La Chaufferie - 555 chemin du bois
Osaka 532-0003 JAPAN 63512 Hainburg GERMANY 69140 Rillieux la Pape FRANCE
+81 6 6396 2250 +49 6182 829 6900 +33 4 8291 0460
One Powerful Vision

premier diagnostic ultrasound


Product Specifications

Network and Connectivity Hardware Features


• Six USB 2.0 ports for memory sticks and peripherals • Footswitch control (scan start, scan stop, scan save, etc.)
• Fully network and printer-ready (gigabit Ethernet) • Removable one-terabyte hard drive
• Purpose-built Windows embedded operating system • Wide screen, 1920 x 1200 high-resolution monitor
• Multilingual user interface

Data Management Electrical Requirements
• DICOM Connectivity: Power supply 100-240 VAC auto-ranging
• Verification of multiple concurrent DICOM connections to
other Application Entities (AEs) Frequency 50/60 Hz
• Query / retrieval of modality work list (patient data from Input power 220 VA
Electronic Medical Records - EMR)
• Storage of DICOM objects to EMR / Picture Archiving and System Size 15.5 x 17 x 6.5 inches (39 x 43 x 16.5 cm)
Communication Systems (PACS) Weight 26 lbs. (12kg)
• Data archiving and image / movie export capability
• Customized report capability

B-Scan Modes A-Scan Modes


Customized to best • Four sets of electronic distance measurement calipers with • IOL power calculations and analysis:
variable velocity
meet your needs. • Two sets of electronic angle measurement calipers (variable
- Holladay-I
- SRK-T
velocity) - Haigis (optional)
• Movie sequence - real-time viewing and editing capability - Hoffer-Q
With customized configuration of
10 MHz Posterior Segment • Movie sequence adjustable up to 5 seconds
A-Scan and B-Scan modes, Eye Cubed™ • 50 frames-per-second image acquisition rate
• 25 frames-per-second image acquisition rate
• 10-second movie loop capability Axial Length Biometry A-Scan
covers all of your diagnostic ultrasound • Sealed probe • Immersion or contact method
needs for both the posterior and anterior • Adjustable transmit gain (minimum to 0 dB) • Solid focused probe with internal fixation light
• Adjustable receive gain (27-90 dB) • Probe frequency: 10 MHz
segments. Featuring superior image • Adjustable dynamic range (Log, S1, S2, S3) • Image depth: 40 mm
• Axial resolution: 50 microns • Points on x-axis: 2048
clarity and flexible measurements, • Lateral resolution: 100 microns • 8 bit resolution
• Scanning angle: 52 degrees
Eye Cubed™ can be used for thorough • Measurement accuracy: 50 microns inherent, 100 microns clinical
• Image depth (displayed image): 48 mm
• Automatic or manual scan acquisition
• Focal depth: 25 mm
pre-operative and post-operative • Built-in pattern recognition with automatic scleral echo detection
• Image width at focal zone: 19-36 mm
• Statistics: average and standard deviation
assessment of ocular anatomy. • Focal range: 15-35 mm
40 MHz UBM Wide-Field Anterior Segment Standardized Diagnostic A-Scan
• 13 frames-per-second image acquisition rate • Two caliper measurements displayed in mm with variable velocities
• 20-second movie loop capability • Tissue sensitivity value stored in memory with reset function
• Probe frequency: 8 MHz parallel beam
• Adjustable transmit gain (minimum to 0 dB)
• Measurement accuracy: 50 microns inherent, 100 microns clinical
• Adjustable receive gain (27-90 dB)
• Adjustable dynamic range (Log, S1, S2, S3)
• Axial resolution: 23 microns
• Lateral resolution: 33 microns
• Scanning angle: 30 degrees
• Image depth (displayed image): 11.9 mm
• Focal depth: 12.5 mm
Specifications are subject to change without notice.
• Image width at focal zone: 15-18 mm
© 2013, Ellex Medical Pty Ltd. Ellex, Eye Cubed, Smart Talk and Sensitive Scan are trademarks
• Focal range: 10.5-14.5 mm of Ellex Medical Pty Ltd. E&OE. PB0012H
Considered to be the gold standard in ophthalmic diagnostic ultrasound,
®
Eye Cubed™ features advanced movie mode using the fastest sampling
Headquarters
82 Gilbert Street
USA
7138 Shady Oak Road
Australia
82 Gilbert Street
rate available, real-time image processing and a range of self-calibrating
Adelaide, SA, 5000 AUSTRALIA Minneapolis, MN, 55344 USA Adelaide, SA, 5000 AUSTRALIA 0805
+61 8 8104 5200 800 824 7444 +61 8 8104 5264
Smart Talk™ probes to deliver unparalleled image sensitivity and quality.
Japan Germany France
4-3-7 Miyahara 4F, Yodogawa-ku Edisonstraße 20 La Chaufferie - 555 chemin du bois
Osaka 532-0003 JAPAN 63512 Hainburg GERMANY 69140 Rillieux la Pape FRANCE
+81 6 6396 2250 +49 6182 829 6900 +33 4 8291 0460
PREMIER DIAGNOSTIC ULTRASOUND

Customized Configuration to Best Meet Your Needs 1 Highest Signal-to-Noise Ratio for Better Vision 7 NEW Real-Time Image Processing for a More Defined, Detail-Rich Image
7 Smart Talk™ Probes

Image processing algorithms and unique amplifiers allow you to enhance each scan in real-time – not after the fact.
Customized configuration of A-Scan and B-Scan modes ensures that Eye Cubed™ With a unique amplifier and probe design, combined with the industry’s highest 40 MHz UBM
These algorithms are optimized for use in ophthalmic echography and have been developed by Ellex’s in-house Wide-Field
meets all of your needs for both the posterior and anterior segments. signal-to-noise ratio, Eye Cubed™ delivers substantially more ultrasonic data per
second than any other ultrasound system on the market today. Because noise is software engineering team to deliver greater image control. Choose your preferred interpolation method from a Anterior Segment
number of options, including: B-Scan Probe
40 MHz UBM B-Scan mode delivers accurate measurement and evaluation of reduced to a minimum, details of even the finest ocular structures become visible
– including blood and inflammatory cells. Available with
the iris, lens, angle and cilliary body, including sulcus-to-sulcus (ICL sizing) and 1. Lowest neighbor 3. Bi-linear interpolation ClearScan®
IOL haptic placement. Immersion Bag
2. Linear interpolation 4. Cubic interpolation *ClearScan is a registered
2 Advanced Movie Technology for Greater Ease of Use trademark of ESI, Inc.
10 MHz Posterior B-Scan mode produces the subtlest vitreous echoes, offering
unparalleled distinction between the retina, choroid and sclera, as well as the
10 MHz Sealed
vitreo retinal junction. Eye Cubed’s advanced movie technology allows you to capture up to 20-second 8 NEW Sensitive Scan™ Transmit Energy Control for Greater Image Detail
movies, enhancing the diagnostic capability and speed of each exam. Review B-Scan Probe
these movies frame-by-frame for greater detail, or play them back in full movie- Featuring Sensitive Scan™ technology, Eye Cubed™ enables you to adjust the probe transmit energy to ensure optimal
Biometry A-Scan delivers ultra-precise axial length measurement with faster,
mode. tissue sensitivity. This gives you the ability to discern between the finest ocular structures, such as subtle vitreous
easier image acquisition in real-time movie mode.
opacities and subretinal fluids.
Standardized Diagnostic A-Scan enables precision tissue differentiation.
3 High Speed Imaging for Real-Time Display

9 NEW Self-Calibrating Smart Talk™ Probes 10 MHz


With an image acquisition and display rate of up to 25 frames-per second, Focused
B-Scan Modes Eye Cubed™ provides the fastest image-sampling rate available. This speed Each Smart Talk™ probe communicates with the Eye Cubed’s system electronics to deliver greater image detail, A-Scan Probe
creates a real-time view of detailed ocular activity, including blood cell movement sensitivity and resolution. Unlike conventional probes, which use average probe settings, this process of self- With internal
and membrane behavior. calibration ensures that each Smart Talk™ probe is assigned the optimal parameter settings based on its mechanical fixation light for
biometry A-Scan
and acoustic characteristics.

4 Custom Velocity Settings for Greater Precision


8 MHz
A-Scan Probe
In addition to pre-programmed velocities for phakic, aphakic and 4 types of
pseudo-phakic eyes, Eye Cubed™ enables you to adjust for all particular cases For standardized
diagnostic A-Scan
and program velocities accordingly.


40 MHz UBM Wide-Field Anterior 10 MHz Posterior
5 DICOM for Improved Connectivity

An optional DICOM license streamlines the examination process, from start to


A-Scan Modes Accessories
finish:

1. Load patient work list from the EMR system and select patient record
Scleral Shells
2. Perform examination for B-Scan
3. Store examination reports to the network (EMR system or Picture Archiving Available in:
and Communication System – PACS) 20mm Adult size
18mm Pediatric size

6 Intuitive User-Friendly Software Shells for


Immersion
Biometry
Eye Cubed™ incorporates a number of features designed to accelerate practice
Available in:
Standardized Diagnostic Axial Length Biometry workflow, including improved export and import functionality and expanded
17mm Adult size
measurement options. Intuitive and easy-to-use, it offers a multilingual user 15mm Pediatric size
interface, full-screen scan viewing and customized report capability.
PREMIER DIAGNOSTIC ULTRASOUND

Customized Configuration to Best Meet Your Needs 1 Highest Signal-to-Noise Ratio for Better Vision 7 NEW Real-Time Image Processing for a More Defined, Detail-Rich Image
7 Smart Talk™ Probes

Image processing algorithms and unique amplifiers allow you to enhance each scan in real-time – not after the fact.
Customized configuration of A-Scan and B-Scan modes ensures that Eye Cubed™ With a unique amplifier and probe design, combined with the industry’s highest 40 MHz UBM
These algorithms are optimized for use in ophthalmic echography and have been developed by Ellex’s in-house Wide-Field
meets all of your needs for both the posterior and anterior segments. signal-to-noise ratio, Eye Cubed™ delivers substantially more ultrasonic data per
second than any other ultrasound system on the market today. Because noise is software engineering team to deliver greater image control. Choose your preferred interpolation method from a Anterior Segment
number of options, including: B-Scan Probe
40 MHz UBM B-Scan mode delivers accurate measurement and evaluation of reduced to a minimum, details of even the finest ocular structures become visible
– including blood and inflammatory cells. Available with
the iris, lens, angle and cilliary body, including sulcus-to-sulcus (ICL sizing) and 1. Lowest neighbor 3. Bi-linear interpolation ClearScan®
IOL haptic placement. Immersion Bag
2. Linear interpolation 4. Cubic interpolation *ClearScan is a registered
2 Advanced Movie Technology for Greater Ease of Use trademark of ESI, Inc.
10 MHz Posterior B-Scan mode produces the subtlest vitreous echoes, offering
unparalleled distinction between the retina, choroid and sclera, as well as the
10 MHz Sealed
vitreo retinal junction. Eye Cubed’s advanced movie technology allows you to capture up to 20-second 8 NEW Sensitive Scan™ Transmit Energy Control for Greater Image Detail
movies, enhancing the diagnostic capability and speed of each exam. Review B-Scan Probe
these movies frame-by-frame for greater detail, or play them back in full movie- Featuring Sensitive Scan™ technology, Eye Cubed™ enables you to adjust the probe transmit energy to ensure optimal
Biometry A-Scan delivers ultra-precise axial length measurement with faster,
mode. tissue sensitivity. This gives you the ability to discern between the finest ocular structures, such as subtle vitreous
easier image acquisition in real-time movie mode.
opacities and subretinal fluids.
Standardized Diagnostic A-Scan enables precision tissue differentiation.
3 High Speed Imaging for Real-Time Display

9 NEW Self-Calibrating Smart Talk™ Probes 10 MHz


With an image acquisition and display rate of up to 25 frames-per second, Focused
B-Scan Modes Eye Cubed™ provides the fastest image-sampling rate available. This speed Each Smart Talk™ probe communicates with the Eye Cubed’s system electronics to deliver greater image detail, A-Scan Probe
creates a real-time view of detailed ocular activity, including blood cell movement sensitivity and resolution. Unlike conventional probes, which use average probe settings, this process of self- With internal
and membrane behavior. calibration ensures that each Smart Talk™ probe is assigned the optimal parameter settings based on its mechanical fixation light for
biometry A-Scan
and acoustic characteristics.

4 Custom Velocity Settings for Greater Precision


8 MHz
A-Scan Probe
In addition to pre-programmed velocities for phakic, aphakic and 4 types of
pseudo-phakic eyes, Eye Cubed™ enables you to adjust for all particular cases For standardized
diagnostic A-Scan
and program velocities accordingly.


40 MHz UBM Wide-Field Anterior 10 MHz Posterior
5 DICOM for Improved Connectivity

An optional DICOM license streamlines the examination process, from start to


A-Scan Modes Accessories
finish:

1. Load patient work list from the EMR system and select patient record
Scleral Shells
2. Perform examination for B-Scan
3. Store examination reports to the network (EMR system or Picture Archiving Available in:
and Communication System – PACS) 20mm Adult size
18mm Pediatric size

6 Intuitive User-Friendly Software Shells for


Immersion
Biometry
Eye Cubed™ incorporates a number of features designed to accelerate practice
Available in:
Standardized Diagnostic Axial Length Biometry workflow, including improved export and import functionality and expanded
17mm Adult size
measurement options. Intuitive and easy-to-use, it offers a multilingual user 15mm Pediatric size
interface, full-screen scan viewing and customized report capability.
One Powerful Vision

premier diagnostic ultrasound


Product Specifications

Network and Connectivity Hardware Features


• Six USB 2.0 ports for memory sticks and peripherals • Footswitch control (scan start, scan stop, scan save, etc.)
• Fully network and printer-ready (gigabit Ethernet) • Removable one-terabyte hard drive
• Purpose-built Windows embedded operating system • Wide screen, 1920 x 1200 high-resolution monitor
• Multilingual user interface

Data Management Electrical Requirements
• DICOM Connectivity: Power supply 100-240 VAC auto-ranging
• Verification of multiple concurrent DICOM connections to
other Application Entities (AEs) Frequency 50/60 Hz
• Query / retrieval of modality work list (patient data from Input power 220 VA
Electronic Medical Records - EMR)
• Storage of DICOM objects to EMR / Picture Archiving and System Size 15.5 x 17 x 6.5 inches (39 x 43 x 16.5 cm)
Communication Systems (PACS) Weight 26 lbs. (12kg)
• Data archiving and image / movie export capability
• Customized report capability

B-Scan Modes A-Scan Modes


Customized to best • Four sets of electronic distance measurement calipers with • IOL power calculations and analysis:
variable velocity
meet your needs. • Two sets of electronic angle measurement calipers (variable
- Holladay-I
- SRK-T
velocity) - Haigis (optional)
• Movie sequence - real-time viewing and editing capability - Hoffer-Q
With customized configuration of
10 MHz Posterior Segment • Movie sequence adjustable up to 5 seconds
A-Scan and B-Scan modes, Eye Cubed™ • 50 frames-per-second image acquisition rate
• 25 frames-per-second image acquisition rate
• 10-second movie loop capability Axial Length Biometry A-Scan
covers all of your diagnostic ultrasound • Sealed probe • Immersion or contact method
needs for both the posterior and anterior • Adjustable transmit gain (minimum to 0 dB) • Solid focused probe with internal fixation light
• Adjustable receive gain (27-90 dB) • Probe frequency: 10 MHz
segments. Featuring superior image • Adjustable dynamic range (Log, S1, S2, S3) • Image depth: 40 mm
• Axial resolution: 50 microns • Points on x-axis: 2048
clarity and flexible measurements, • Lateral resolution: 100 microns • 8 bit resolution
• Scanning angle: 52 degrees
Eye Cubed™ can be used for thorough • Measurement accuracy: 50 microns inherent, 100 microns clinical
• Image depth (displayed image): 48 mm
• Automatic or manual scan acquisition
• Focal depth: 25 mm
pre-operative and post-operative • Built-in pattern recognition with automatic scleral echo detection
• Image width at focal zone: 19-36 mm
• Statistics: average and standard deviation
assessment of ocular anatomy. • Focal range: 15-35 mm
40 MHz UBM Wide-Field Anterior Segment Standardized Diagnostic A-Scan
• 13 frames-per-second image acquisition rate • Two caliper measurements displayed in mm with variable velocities
• 20-second movie loop capability • Tissue sensitivity value stored in memory with reset function
• Probe frequency: 8 MHz parallel beam
• Adjustable transmit gain (minimum to 0 dB)
• Measurement accuracy: 50 microns inherent, 100 microns clinical
• Adjustable receive gain (27-90 dB)
• Adjustable dynamic range (Log, S1, S2, S3)
• Axial resolution: 23 microns
• Lateral resolution: 33 microns
• Scanning angle: 30 degrees
• Image depth (displayed image): 11.9 mm
• Focal depth: 12.5 mm
Specifications are subject to change without notice.
• Image width at focal zone: 15-18 mm
© 2013, Ellex Medical Pty Ltd. Ellex, Eye Cubed, Smart Talk and Sensitive Scan are trademarks
• Focal range: 10.5-14.5 mm of Ellex Medical Pty Ltd. E&OE. PB0012H
Considered to be the gold standard in ophthalmic diagnostic ultrasound,
®
Eye Cubed™ features advanced movie mode using the fastest sampling
Headquarters
82 Gilbert Street
USA
7138 Shady Oak Road
Australia
82 Gilbert Street
rate available, real-time image processing and a range of self-calibrating
Adelaide, SA, 5000 AUSTRALIA Minneapolis, MN, 55344 USA Adelaide, SA, 5000 AUSTRALIA 0805
+61 8 8104 5200 800 824 7444 +61 8 8104 5264
Smart Talk™ probes to deliver unparalleled image sensitivity and quality.