Series PWS30/ PWS30-2: Pure Water
Series PWS30/ PWS30-2: Pure Water
Series PWS30/ PWS30-2: Pure Water
PURE WATER
Standards
Control Valve- WQA Certified to NSF/ANSI Std. 61 Ion Exchange Resin- NSF Certified to ANSI Std. 44 Mineral Tank- NSF Certified to ANSI Std. 44 or 61
Specifications
A Watts Pure Water PWS30 series water softening system shall be installed on the buildings main water line just after it enters the building. The installation point shall be after any back flow prevention or pressure regulating valves. Other installation options are to install a system just before the water heater or other types of equipment needing the protection of softened water. In installations where dedicated cold water make up to a water heater is the installation point a back flow preventer and a thermal expansion tank must be installed as well. The system shall be installed with a bypass valve to allow for the shut down and removal of the unit without interrupting the water supply to the building. The water softener shall be a down flow regenerated, metered demand, sodium cycle cation exchange type system with all components necessary for proper operation. Electrical requirements are 120 volt 60 hertz. A local drain is required to accept drain water from the system. The feed water pressure must not fall below 25psi or exceed 125psi. Water temperature must not fall below 34F or exceed 110F. The system shall provide softened water measuring less than one grain per gallon of hardness as Calcium Carbonate when operated within the manufacturers operational specifications.
Features
WQA Certified fully automatic metered demand control valve S ophisticated digital electronic controls that store operating history that can be accessed by the user Fully adjustable regeneration cycles Durable brass bodied control valve for years of service Dry contact lock out switch for remote interface is standard NSF Certified high capacity resin Highly corrosion resistant NSF Certified fiberglass tanks Durable polypropylene lower distribution system
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
* For all other guideline information please contact your Watts representative.
Dimensions - Weight
PWS30 Series
E E D D
PWS30-2 Series
E E D D
F F
FF
B B A A
C C B B
C C
A A
G G
G G
FRONT
FRONT
SIDE
SIDE
FRONT FRONT
SIDE SIDE
WEIGHTS kgs
PWS30151H11 PWS30151I11 PWS30151J11 PWS30151K11 PWS30151L11 PWS30151H21 PWS30151I21 PWS30151J21 PWS30151K21 PWS30151L21
2017 2068 2216 2419 2530 2017 2068 2216 2419 2530
2017 95 / 2068 96 / 2216 101 2419 108 2530 1123/8 2017 951/4 2068 963/4 2216 101 2419 108 2530 1123/8
2419 2457 2565 2743 2854 2419 2457 2565 2743 2854
622 765 917 1118 1280 622 765 917 1118 1280
622 765 917 1118 1280 2159 2540 2819 3200 3810
30 39 39 42 50 30 39 39 42 50
762 991 991 1067 1270 762 991 991 1067 1270
50 48 60 60 60 50 48 60 60 60
1270 1219 1524 1524 1524 1270 1219 1524 1524 1524
1070 1600 2015 3245 4295 2070 3000 4015 6245 8295
486 727 916 1475 941 941 1364 1325 2839 3770
Specifications
MODEL NUMBER TANK SIZE Mineral Tank RESIN GRAVEL Ft3 Brine Tank TANK SALT size fill Softening CAPACITY Max min Lbs. Salt Per REGENERATION max MIN Flow Rate & PressurE SERV DROP BKW GPM PSI GPM
10 15 20 30 35
200 lbs. 400 lbs. 500 lbs. 700 lbs. 900 lbs.
15 25 35 45 60
Ordering Information
MODEL NUMBER DESCRIPTION SPACE REQUIRED DXWXH WEIGHT
PWS30151H11 PWS30151I11 PWS30151J11 PWS30151K11 PWS30151L11 PWS30151H21 PWS30151I21 PWS30151J21 PWS30151K21 PWS30151L21
10 Cubic Foot 3" Simplex Softener with Flow Meter 15 Cubic Foot 3" Simplex Softener with Flow Meter 20 Cubic Foot 3" Simplex Softener with Flow Meter 30 Cubic Foot 3" Simplex Softener with Flow Meter 35 Cubic Foot 3" Simplex Softener with Flow Meter 10 Cubic Foot 3" Duplex Alternating Softener with Flow Meter 15 Cubic Foot 3" Duplex Alternating Softener with Flow Meter 20 Cubic Foot 3" Duplex Alternating Softener with Flow Meter 30 Cubic Foot 3" Duplex Alternating Softener with Flow Meter 35 Cubic Foot 3" Duplex Alternating Softener with Flow Meter
39 x 69 x 103 39 x 75 x 107 39 x 81 x 109 42 x 90 x 117 50 x 104 x 117 39 x 100 x 103 39 x 117x 107 39 x 129 x 109 42 x 144 x 117 50 x 164 x 117
1070 lbs. 1600 lbs. 2015 lbs. 3245 lbs. 4295 lbs. 2070 lbs. 3000 lbs. 4015 lbs. 6245 lbs. 8295 lbs.
Notes: Capacities are based on resin manufactures data and are dependent upon influent water TDS, temperature, bed depth, and flow rates. Feed water must be free of oil and color and. Pipe size, tank size, and space requirements are in inches. Capacities and flow rates expressed above are per tank. Flow rates listed at 25psi drops are for intermittent peak flow rates and are not to be used as continuous flows.
USA: North Andover, MA Tel. (800) 224-1299 www.watts.com Canada: Burlington, ON Tel. (888) 208-8927 www.wattscanada.ca
ES-WQ-PWS30 1105
2011 Watts