YCC Training by Fives Pillard
YCC Training by Fives Pillard
YCC Training by Fives Pillard
EQUIPMENTS
YANBU
CEMENT PLANT
BY
SINOMA
Scope of supply
! ROTARY KILN FIRING EQUIPMENT
! 1 Expansion tank
! 2 HP pumps
! 1 control cabinet
NOVAFLAM KILN BURNER
Air circuits burner kiln
Air circuits and supply oil
PRIMARY
AIR
CENTRAL
AIR
COOLING SECONDARY
AIR OIL
OUTLET PRIMARY
OIL
Burner tip
Primary
air
Central
air
Tip Novaflam
Primary air channel
Central air
Supply secondary
heavy oil
Gun MY burner for kiln &
calciner
Jacket tube gun Tip pulverizing
Atomizer 2
Atomizer 1
Spray plate
Cap
Circuit Primary
Jacket tube
Set MY atomiser
Flow oil
Number set
Pressure oil
Atomizer MY
Ring inlet primary flow heavy oil Inlet secondary flow heavy oil
Atomizer : 1 Atomizer : 2
Set atomizer MY
Spray plate Spray plate Atomizer : 2
Injector gas
Ignition electrode
Igniter gas
Electrode ignition Electrode detection of flame Light flame OK
Detector flame
Light control
Train valve igniter gas
Filter gas
Injector gas
Electrode ignition
Adjustment : 3 ~ 4 mm
Transformer
Connector electric
Supply gas
Supply air
Cabinet igniter gas
Flame shape
Boolt of block
Ajustment flame burner kiln
MY valve train burner kiln
Circuit Secondary Regulation valve air
compressed
Circuit Primary
Purging valves
Manual valve
adjust secondary
Filter oil
Safety valves
Flow meter oil
Manual
valve close
Primary
Automatic valve
Stand-by air
emergency circuit
fan
air
Central air
Valve close
Valve open
Manuel valve
central air
Manuel valve
primary air
Circuit Central air
MY valve train burner calciner
Primary air fan burner calciner
valve train MY Calciner
Skid valve train MY Calciner
Safety valves
Secondary
adjusting valve
Secondary
Primary oil oil
Purging
valve
FUEL OIL LINE
Circulating pumps heavy oil
To boiler house
end loop
From HFO
thank
End loop heavy oil regulation set
Automatic valve
Pressure gauge
Return oil tank
Pressure transmitter
Pump stand by
return oil
HP Pump runing
to intlet
Supply oil
HP pump regulation manual
Valve regulation pressure Valve close Outlet oil to burner
Supply oil
Thermal oil line
Heating set : thermal oil line
Heater heavy oil
Automatic valve
regulation temperature oil
Intlet Heavy
oil
Cabinet boiler
HP pump
Boiler control panel
Pressure gauje inlet Pressure gauje outlet
Control flow thermal oil 1
Controler temperature
thermal oil Light safety fault boiler
Selector diesel
or heavy oil
Light operating boiler
Thermal oil circulation pump
Valve purging
Pump circulating 1
Pump circulating 2
Pressure gauge
Filter
Pump filling
Tank supply thermal oil
Tracing supply
Supply thermal oil in operating
Kiln return
Return thermal Manual valve supply thermal
Heater return oil to pump by pass close oil from boiler
Flamme Width 0 mm
Adjustment valves air before
ignition burner kiln
Manual valve primary 70 mbar
Manual valve central 50 mbar
Kiln is cold
Adjustment pressure air for
burner in product
Pressure gauge Primary >160 mbar
Pressure gauge Central >100 mbar
Central position
10 mm
Flamme Width + 15 mm
Adjustment valves air burner kiln
in product
Manual valve Primary 100% open
Kiln is hot