Lift Connect™
Telematics Ready Connector
Introduction
Intro ductio n Intro ductio n
Introduction
Revision History
Revision Date Section Procedure / Page / Description
A 2/2019 Initial Release
B 12/2021 I\O Specifications Add legacy 8 pin TRC information
TRC Function Pin Out Add note for GS, GR, GRC and QS models
Safety Rules
Unavailable I/O
Some Genie models do not support all of the discrete outputs. If a particular circuit feature is not available,
it shall be left unconnected. There shall be no substitution or other optional wiring.
Refer to the appropriate TRC Function Pin Out for your model.
Unavailable I/O
Some Genie models do not support all of the discrete outputs. If a particular circuit feature is not available,
it shall be left unconnected. There shall be no substitution or other optional wiring.
Refer to the appropriate TRC Function Pin Out for your model.
5 - Model specific
(depending on model, this will connect to pin 6 - Boom \ Platform stowed status
6 or pin 10 of the 12 pin TRC)
8 - No Connection
9 - No Connection
10 - Foot switch / Function enable or GTH
(refer to pin 5)
parking brake
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 24 VDC DC Motor Controller Enable Monitor machine run hours
24V = enabled, 0V = disabled
5 Digital Output 2 24 VDC Key Switch Activation Monitor machine utilization
24V = key switch on
6 No Connection X X X
7 Digital Input 1 24 VDC (Z-60/37 Remote Machine Disable Active Remote disable motor
Models) Low Relay controller
8 No Connection X X X
9 No Connection X X X
10 Digital Output 4 24 VDC (Z-60/37 Foot Switch Activation Monitor machine utilization
Models)
11 Databus H CAN HIGH CAN/J1939 SAE J1939 Messages
12 Databus L CAN HIGH CAN/J1939 SAE J1939 Messages
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 12 VDC IC Engine Run Monitor engine run hours
12V = engine run, 0V = engine off
5 Digital Output 2 12 VDC Key Switch Activation Monitor machine utilization
12V = key switch on
6 Digital Output 3 12 VDC Platform Stowed Status Monitor platform stowed and
12V = stowed, 0V = out of stow out of stowed status
7 Digital Input 1 12 VDC Remote Machine Disable Active Remote disable engine start
Low Relay
8 No Connection X X X
9 No Connection X X X
10 No Connection X X X
11 Databus H CAN HIGH CAN/J1939 SAE J1939 Messages
12 Databus L CAN HIGH CAN/J1939 SAE J1939 Messages
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 24 VDC DC Motor Controller Enable Monitor machine run hours
24V = enabled, 0V = disabled
5 Digital Output 2 24 VDC Key Switch Activation Monitor machine utilization
24V = key switch on
6 Digital Output 3 24 VDC Boom Stowed Status Monitor platform stowed
24V = stowed, 0V = out of stow and out of stowed status
7 Digital Input 1 24 VDC Remote Machine Disable Active Remote disable motor
Low Relay controller
8 No Connection X X X
9 No Connection X X X
10 Digital Output 4 24 VDC Foot Switch Activation Monitor machine utilization
24V = foot switch pressed
11 No Connection X X X
12 No Connection X X X
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12, 24 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 12 VDC IC Engine Run Monitor engine run hours
12V = engine run, 0V = engine off
5 Digital Output 2 12, 24 VDC Key Switch Activation Monitor machine utilization
12/24V = key switch on
6 Digital Output 3 12, 24 VDC Boom Stowed Status Monitor platform stowed
12/24V = stowed, 0V = out of stow and out of stowed status
7 Digital Input 1 12, 24 VDC Remote Machine Disable Active Remote disable engine start
Low Relay
8 No Connection X X X
9 No Connection X X X
10 Digital Output 4 12, 24 VDC Foot Switch Activation Monitor machine utilization
12/24V = foot switch pressed
11 Databus H CAN HIGH CAN/J1939 Receive Proprietary Genie
Telematics Message
12 Databus L CAN LOW CAN/J1939 Receive Proprietary Genie
Telematics Message
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 12 VDC IC Engine Run Monitor engine run hours
12V = engine run, 0V = engine off
5 Digital Output 2 12 VDC Key Switch Activation Monitor machine utilization
12V = key switch on
6 No Connection X X X
7 Digital Input 1 12 VDC Remote Machine Disable Active Remote disable engine start
Low Relay
8 No Connection X X X
9 No Connection X X X
10 Digital Output 4 Foot Switch Activation Monitor machine utilization
12V = foot switch pressed
11 Databus H CAN HIGH CAN/J1939 Receive Proprietary Genie
Telematics Message
12 Databus L CAN LOW CAN/J1939 Receive Proprietary Genie
Telematics Message
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 12 VDC IC Engine Run Monitor engine run hours
12V = engine run, 0V = engine off
5 Digital Output 2 12 VDC Key Switch Activation Monitor machine utilization
12V = key switch on
6 No Connection X X X
7 Digital Input 1 12 VDC Remote Machine Disable Active Remote disable engine start
Low Relay
8 No Connection X X X
9 No Connection X X X
10 Digital Output 4 12 VDC Foot Switch Activation Monitor machine utilization
12V = foot switch pressed
11 Databus H CAN HIGH CAN/J1939 Receive Proprietary Genie
Telematics Message
12 Databus L CAN LOW CAN/J1939 Receive Proprietary Genie
Telematics Message
GTH Models
This Legend Only Applies to the Following Genie Models
GTH-636 GTH-1256 GTH-3007
GTH-844 GTH-1544 GTH-5519
GTH-1056 GTH-2506
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 12 VDC IC Engine Run Monitor engine run hours
12V = engine run, 0V = engine off
5 Digital Output 2 12 VDC Key Switch Activation Monitor machine utilization
12V = key switch on
6* Digital Output 3 12 VDC Boom Angle Status Monitor boom angle status
12V = boom >55°, 0V = < 55°
7 Digital Input 1 12 VDC Remote Machine Disable Active Remote disable engine start
Low Relay
8 No Connection X X X
9 No Connection X X X
10 Digital Output 4 12 VDC Parking Brake Monitor machine utilization
12V = enabled, 0V = disabled
11 Databus H CAN HIGH CAN/J1939 Receive Proprietary Genie
Telematics Message
12 Databus L CAN LOW CAN/J1939 Receive Proprietary Genie
Telematics Message
* Not available on GTH-636
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 12 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 12 VDC IC Engine Run Monitor engine run hours
12V = engine run, 0V = engine off
5 Digital Output 2 12 VDC Key Switch Activation Monitor machine utilization
12V = key switch on
6 No Connection X X X
7 Digital Input 1 12 VDC Remote Machine Disable Active Remote disable engine start
Low Relay
8 No Connection X X X
9 No Connection X X X
10 No Connection X X X
11 No Connection X X X
12 No Connection X X X
TZ Models
This Legend Only Applies to the Following Genie Models
TZ-34/20 TZ-50
Pin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case
1 System Power 24 VDC Battery Positive – constant power Supply power to device
5 Amp Max. allowed draw
2 System Ground 0 VDC Battery Negative Device ground
3 BND Control 0 VDC Chassis Ground BND switch ground
(customer installed option)
4 Digital Output 1 24 VDC DC Motor Controller Enable Monitor machine run hours
24V = enabled, 0V = disabled
5 Digital Output 2 24 VDC Key Switch Activation Monitor machine utilization
24V = key switch on
6 Digital Output 3 24 VDC Boom Stowed Status Monitor platform stowed
24V = stowed, 0V = out of stow and out of stowed status
7 Digital Input 1 24 VDC Remote Machine Disable Active Remote disable motor
Low Relay controller
8 No Connection X X X
9 No Connection X X X
10 No Connection X X X
11 No Connection X X X
12 No Connection X X X
Lift Con nect™ Part No. 129 490 5GT Service Manu al Sup plem ent Decem ber 202 1