FR-D700 Series: Max Load Capacity Capacity
FR-D700 Series: Max Load Capacity Capacity
FR-D700 Series: Max Load Capacity Capacity
FR-D700 Series
Low cost micro VFD with Mitsubishi Electric quality.
• Simple to use: The FR-D700 is perfect for a wide • 150% torque at 1Hz and 200% torque at 3Hz using
range of applications General-purpose Magnetic Flux Vector Control
• Simple to set-up: The integrated digital setting dial • Optimum Excitation Control: For increased energy
with display makes configuration fast and easy savings when motor is not loaded
• Simple operation: Control remotely or with the • Frequency search function: Catch a spinning load
built-in digital control • Dancer control: Allows position signal to control
• Simple to choose: Low cost and with Mitsubishi roll tension
Electric quality ensuring long operation life • Password function: For parameter setting
• Capacity: From 1/8 to 20 HP protection
• Safety stop function: Meets EN954-1 Category 3 and • Internal diagnostics function: For monitoring
IEC60204-1 Stop Category 0 status of critical components
• Integrated brake chopper circuit • RoHS compliant
• MODBUS RTU: Included as standard via the • 10 year maintenance free design
RJ45 port
115
1 Phase 1/8 – 1 Hp
1 Max Load Capacity 2 Capacity 240
1 Phase 1/8 – 3 Hp
Symbol Voltage Class Symbol
D710W 1-phase 110V class Inverter capacity amperage / 10 240
1/8 – 10 Hp
3 Phase
D720S 1-phase 240V class (008 = 0.8A output)
D720 3-phase 240V class 480
3 Phase 1/2 – 10 Hp
D740 3-phase 480V class
Horsepower
FR-D700 Series
Rating (CT & VT) IP20 Open Chassis Dimensions in inches (mm)
Weight lbs (kg) Stocked Item
HP Rated Amps Model Number Height Width Depth
1-Phase 100~120VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-D710W-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D710W-014-NA 5.0 (128) 2.7 (68) 4.4 (110.5) 1.3 (0.6) S
1/2 2.5 FR-D710W-025-NA 5.0 (128) 2.7 (68) 5.6 (142.5) 2.0 (0.9) S
1 4.2 FR-D710W-042-NA 5.0 (128) 4.3 (108) 5.9 (149.5) 3.1 (1.4) S
1-Phase 200~240VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-D720S-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D720S-014-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.3 (0.6) S
1/2 2.5 FR-D720S-025-NA 5.0 (128) 2.7 (68) 5.6 (142.5) 2.0 (0.9) S
1 4.2 FR-D720S-042-NA 5.0 (128) 2.7 (68) 6.5 (162.5) 2.5 (1.1) S
2 7 FR-D720S-070-NA 5.0 (128) 4.3 (108) 6.2 (155.5) 3.3 (1.5) S
3 10 FR-D720S-100-NA 5.9 (150) 5.5 (140) 5.7 (145) 4.4 (2.0) S
3-Phase 200~240VAC Input & Output
1/8 0.8 FR-D720-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D720-014-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/2 2.5 FR-D720-025-NA 5.0 (128) 2.7 (68) 4.5 (112.5) 1.8 (0.8) S
1 4.2 FR-D720-042-NA 5.0 (128) 2.7 (68) 5.3 (132.5) 2.2 (1.0) S
2 7 FR-D720-070-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
3 10 FR-D720-100-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
5 16.5 FR-D720-165-NA 5.0 (128) 6.7 (170) 5.6 (142.5) 4.0 (1.8) S
7 1/2 23.8 FR-D720-238-NA 5.9 (150) 8.7 (220) 6.1 (155) 8.0 (3.6) S
10 31.8 FR-D720-318-NA 5.9 (150) 8.7 (220) 6.1 (155) 8.0 (3.6) S
3-Phase 380~480VAC Input & Output
1/2 1.2 FR-D740-012-NA 5.0 (128) 4.3 (108) 5.1 (129.5) 2.9 (1.3) S
1 2.2 FR-D740-022-NA 5.0 (128) 4.3 (108) 5.1 (129.5) 2.9 (1.3) S
2 3.6 FR-D740-036-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
3 5 FR-D740-050-NA 5.0 (128) 4.3 (108) 6.2 (155.5) 3.3 (1.5) S
5 8 FR-D740-080-NA 5.0 (128) 4.3 (108) 6.6 (165.5) 3.3 (1.5) S
7 1/2 12 FR-D740-120-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.3 (3.3) S
10 16 FR-D740-160-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.3 (3.3) S
Frequency
Accuracy Digital Input Within 0.01% of the set output frequency
Voltage/Frequency Characteristics Base frequency can be set from 0 to 400Hz. Constant torque/variable torque pattern can be selected
Starting Torque 150% or more (at 1Hz) when General-purpose magnetic flux vector control and slip compensation is set
Torque Boost Manual torque boost
Accel. /Decel. Time Setting 0.01 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected.
FR-D720-008 and 014, FR-D720S-008 and 014, FR-D710W-008 and 014 ... 150%, FR-D720-025 and 042, FR-D740-012 and 022,
Regeneration
FR-D720S-025 and 042, FR-D710W-025 and 042 ... 100%, FR-D720-070, FR-D740-036, FR-D720S-070 ... 50%, FR-D720-100 or
(*1)
Braking Torque more, FR-D740-050 or more, FR-D720S-100 ... 20%
DC Injection
Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Brake
Stall Prevention Operation Level Operation current level can be set (0 to 200% adjustable), whether to use the function or not can be selected
Two points
Frequency Setting Analog Input Terminal 2: 0 to 10V, 0 to 5V can be selected
Signal Terminal 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected
Digital Input Entered from operation panel and parameter unit. Frequency setting increments is selectable.
Start Signal Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Five points. You can select from among multi-speed selection, remote setting, second function selection, terminal 4 input selection,
JOG operation selection, PID control valid terminal, external thermal input, PU-external operation switchover, V/F switchover, output
Input Signal
stop, start self-holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, external-
NET operation switchover, command source switchover, inverter operation enable signal, and PU operation external interlock
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after
Operation Specifications
instantaneous power failure operation, forward/reverse rotation prevention, remote setting, second function, multi-speed operation,
Operational Functions
regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link
operation (RS-485), Optimum excitation control, power failure stop, speed smoothing control, MODBUS-RTU
Open Collector
Output Signal One point
Output
Points
Relay Output One point
You can select from among inverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative brake
prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID
Output Signal
Operating Status lower limit, PID upper limit, PID forward/reverse rotation output, fan alarm (*3), heatsink overheat pre-alarm, deceleration at an
instantaneous power failure, PID control activated, PID output interruption, during retry, life alarm, current average value monitor,
remote output, alarm output, fault output, fault output 3, and maintenance timer alarm
For Meter
Analog Output 0 to 10VDC: one point
Output Points
You can select from among output frequency, output current (steady), output voltage, frequency setting, converter output voltage,
regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value,
For Meter
reference voltage output, motor load factor, PID set point, PID measured value, output power, PID deviation, motor thermal load
factor, inverter thermal load factor 0 to 10VDC
You can select from among output frequency, output current (steady), output voltage, frequency setting, cumulative energization time,
actual operation time, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current
Operation Panel Operating Status
peak value, converter output voltage peak value, motor load factor, PID set point, PID measured value, PID deviation, inverter I/O
Parameter Unit terminal monitor, output power, cumulative power, motor thermal load factor, inverter thermal load factor, PTC thermistor resistance.
(FR-PU07)
Indication
Fault definition is displayed when the fault occurs and the past 8 fault definitions (output voltage/current/frequency/cumulative
Fault Definition
energization time right before the fault occurs) are stored
Additional Display Operating Status Not used
By The Parameter Fault Definition Output voltage/current/frequency/cumulative energization time immediately before the fault occurs
Unit (FR-PU07) Interactive
Only Function (help) for operation guide
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal
operation, heatsink overheat, input phase loss (*5, *6), output side earth (ground) fault overcurrent at start (*5), output phase loss,
Protective Functions
external thermal relay operation (*5), PTC thermistor operation (*5), parameter error, PU disconnection, retry count excess (*5), CPU
fault, brake transistor alarm, inrush resistance overheat, analog input error, stall prevention operation, output current detection value
exceeded (*5), safety circuit fault
Fan alarm (*3), overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake prealarm
Warning Functions (*5), electronic thermal relay function prealarm, maintenance output (*5), undervoltage, operation panel lock, password locked,
inverter reset, safety stop
Surrounding Air Temperature -10°C to +50°C (14°F to 122°F) (non-freezing) (*4)
Environment
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Inverters 2
n INVERTERS
FR-D700 Series Terminal Connection Diagram
*1. DC reactor (FR-HEL) *6 Terminal P1 is not available for single-
Sink logic When connecting a DC reactor, remove the phase 100V power input model.
jumper across P1-P/+
Main circuit terminal Single-phase 100V power input model is not *7 A brake transistor is not built-in to the
Control circuit terminal compatible with DC reactor. FR-D720-008, 014 and FR-D720S-008,
Single-phase power input Brake unit
014 and FR-D710W-008, 014.
MCCB MC (Option)
*8 Brake resistor (FR-ABR, MRS type, MYS
Single-phase *1 type)
R/L1 R
Install a thermal relay to prevent an
AC power Earth
S/L2 (Ground) *8 overheat and burnout of the brake resistor.
supply (The brake resistor can not be connected
Jumper PR N/- to the FR-D720-008, 014 and FR-D720S-
008, 014 and FR-D710W-008, 014.)
P1 P/+ *7
MCCB MC
*6 Motor
Three-phase R/L1 U
Inrush current
AC power S/L2 V
limit circuit IM
supply T/L3 W
Control circuit
Control input signals (No voltage input allowed) C Relay output
Forward STF
Terminal functions vary rotation start Terminal functions vary
B by Pr. 192 A,B,C terminal
with the input terminal Reverse STR Relay output
assignment (Pr. 178 to rotation start (Fault output) function selection
A
Pr. 182) RH
High
speed
RM Open collector output
Multi-speed selection Middle
speed
SOURCE
RUN Terminal functions vary by
RL
SINK
*2 When using terminals PC-
Low Running Pr. 190 RUN terminal function
SD as a 24VDC power
supply, take care not to
speed selection
SD
short across terminals 24V
PC-SD. Contact input common
PC *2 SE Open collector output common
24VDC power supply Sink/source common
(Common for external power supply transistor)
B1
Leakage Dimensions mm (in)
Drive Kit Model φd1
Current Stocked Item
Voltage Number L W D A2 A1
(mA)
5.3
208 - 230 FR-BIF 4 58 (2.3) 44 (1.8) 42 (1.7) S Glass-braided cable
B2
2.0mm2 white
460 FR-BIF-H 4 58 (2.3) 44 (1.8) 42 (1.7) - D
φd2
A2
H
Line Noise Filter
2.5
Provides a toroid for line noise reduction.
Dimensions (mm)
Brake Resistor Model
Kit Model Dimensions mm (in) W W1 W2 D H
Drive HP Stocked Item
Number L W D 200V Class
FR-ABR-0.4K 140 125 100 40 21
0.5 - 5 FR-BSF01 110 (4.33) 22.5 (0.89) 65 (2.56) S
FR-ABR-0.75K 215 200 175 40 21
0.5 - 75 FR-BLF 180 (7.07) 31.5 (1.24) 83 (3.27) S FR-ABR-2.2K 240 225 200 50 26
FR-ABR-3.7K 215 200 175 61 33
FR-ABR-5.5K 335 320 295 61 33
FR-D700 EMC Filters FR-ABR-7.5K 400 385 360 80 40
This attachment allows the VFD to be mounted onto the filter. FR-ABR-11K 400 385 360 100 50
Model Number Drive Model Stocked Item FR-ABR-15K (*1) 300 285 260 100 50
400V Class
FFR-CS-050-14A-SF1 D720S-008 to 042 -
FR-ABR-H0.4K 115 100 75 40 21
FFR-CS-080-20A-SF1 D720S-070 - FR-ABR-H0.75K 140 125 100 40 21
FFR-CS-110-26A-SF1 D720S-100 - FR-ABR-H1.5K 215 200 175 40 21
FFR-CSH-036-8A-SF1 D740-012 to 036 - FR-ABR-H2.2K 240 225 200 50 26
FFR-CSH-080-16ASF1 D740-050 to 080 - FR-ABR-H3.7K 215 200 175 61 33
FR-ABR-H5.5K 335 320 295 61 33
FFR-MSH-170-30ASF1 D740-120 to 160 -
FR-ABR-H7.5K 400 385 360 80 40
FR-ABR-H11K 400 385 360 100 50
FR-ABR-H15K (*2) 300 285 260 100 50
DIN Rail Mounting Attachment Notes:
This attachment allows the D700 Series inverter to mount on a 35mm DIN rail. 1. For the 15K, connect the two supplied resistors (18 ohms) in parallel
2. For the H15K, connect the two supplied resistors (18 ohms) in series.
Drive Model
Model Number Stocked Item
D710W D720S D720 D740
FR-UDA01 008-025 008-042 008-042 - S FR-D700 Conduit Kits
FR-UDA02 042 070 070-100 012-080 S Kit Model Stocked
Description
FR-UDA03 - - 165 - - Number Item
CK-5567 Conduit Kit for D720S-100 S
CK-27 Conduit Kit for D720S-042 S
CK-87 Conduit Kit for D720-238/318 S
CK-43-S Conduit Kit for D720-070/100 / D740-012/036 S
CK-43-T Conduit Kit for D710W-042 / D740-050/080 S
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Inverters 4
n INVERTERS
FR-D700 Dynamic Braking
All Mitsubishi Electric VFDs have some inherent braking capability. During controlled deceleration, motor regenerative losses are dissipated in the motor, wire,
and VFD circuitry. The built-in DC injection braking allows for low speed braking and stopping.
When the above capabilities are inadequate for an application, it is necessary to add a power transistor brake unit and resistor unit in series across the DC bus.
Motor regeneration causes the DC bus voltage to increase, and when the voltage exceeds a specified threshold, the transistor turns on to pass current through
the resistor. Motor kinetic energy is converted to heat energy. VFD overcurrent and overvoltage protective circuits are active at all times, and will fault-trip the
VFD if the brake size is inadequate.
Two main factors must be considered when sizing the brake, the effective duty cycle (%ED) and the short time duty rating. The effective duty cycle is increased
when an external resistor is added. It is preferable to profile the effective duty cycle of the units of time. With this information, the short time duty is known and
the %ED can be calculated, as shown in the below example.
%ED = Braking time / total time for complete operating cycle *100
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Inverters 6